Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RC-15-903
ALC EXCAVATORS INC. 25525 S.W. 141Ave Homestead FI 930$2. PH O5 213 2803 cell INVOICE QC- --X10 BY. NOV 1 0 2015 STYLE HOMES CORR. STYLEHOMESCORPPHOT DATE JOBSITE ADDRESS S INSCRIPTION TERMS MAILCOM JOPin 1/11 "OSTS° CERTIFICATION 11/11/15 500 NE 92 ST Due upon receipt Work Completed DESCRIPTION AMOUNT * EXPOSE THE THE EXISTING SEPTIC TANK * * CLEAN SEPTIC AND DETERMINE APPROX LOCATION... * * PREPARE ALL REQUIRED PAPER WORK TO SUBMIT TO DEPT OF HEALTH * * OPTIONAL SUBMIT AND PROCESS AT DEPT OF HEALTH SHALL BE AN ADDITIONAL $$100.00 PLUS DEPT OF HEALTH FEES NOT INCLUDED HERE .. (N/A) $650.00 . . . . • .. ..• • • . .... "We at ALL State Diversified Engineering, Inc., appreciate your business!" TOTAL sii(0p . -- 1.0.0 Ph: 305-234-5222 Fax: 786-206-3076 Cell: 305-213-2803 • . .•. • ... .. • • • • . : . • • • ..• • ••• • . • • STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: [ 1 New System I ] Repair Existing System [ ] Abandonment APPLICANT: Porto Cabral 1.1.0 AGENT: Alfexcavators Inc [ 1 I 1 Holding Tank Temporary MAILING ADDRESS: 25525 Sw 1-41- AveNYnstd FI 33032 PERMIT NO. DATE PAID: FEE PAID: RECEIPT 0: I ] Innovative I 1 305-234-5222 TELEPHONE: TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT I3 THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (Mt/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LoT:4, fat SUBDIVISION. Miamishores sec Prior 72 PLATTED: PROPERTY ID 411-3206-014-1200 ZONING: N/A I/M OR EQUIVALENT: (Y / i ] PROPERTY SIZE: ACRES WATER SUPPLY: [ ] PRIVATE PUBLIC [X]<=12000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [Y / N] DISTANCE TO SEWER: N/A PROPERTY ADDRESS: 500 NE 92 St DIRECTIONS TO PROPERTY: I-95 exit Nw 95 St head east to Ne 5 Ave head south to property .. DOC1 RESIDENTIAL, [ 1 COMMERCIAL Unit Type of No. of Building Commercial/Institutional System Design No Establishment Bedrooms Area Sgft Table 1, Chapter 64E-6, FAC BUILDING INFORMATION 1 SER 2 3 4 [ ] Floor/Equipme SIGNATURE: DH 4015, 10/97 (Previous Edi 2 1634 .. • . • 0. • . • . WWWw . . 0000 . • Other (Specify) Sni890-861 . . .. . • . . • . • .0•. . . . .. . • . ons May Be Used) ONLINE VERSION . . . DATE: '19141/15....• Page 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH APPLICATION FOR ONSITE SEWAGE DISPOSAL SYSTEM CONSTRUCTION PERMIT Permit Application Number PART II - SITEPLAN Scale: Each block presents 10 feet and 1 inch = 40 feet. Votes: •••r:+ A;,07 �% ,Site Plan submitted by: GUILLERMO SUAREZ JR SM 89C Plan Approved Not Aigro 3y� • •. • u . • • • • ff•if•- •••• • Date ' : • • _ Counly Ne4lth Department • • • ALL CHANGES MUST BE APPROVED BY THE COUNTY HEALTH DEPARTMENT )H 4015,10/96 (Replaces MRS -H Form 4016 which may be wed) Stock Number: 5744.002.4015-0) Pegs 2of4 • • •f••• �• • • STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS APPLICANT: Porto Cabral PERMIT #. AGENT: ALC EXCAVATORS, INC LOT: 4 BLOCK: 58 SUBDIVISION: Miami shore sec PROPERTY ID 0: 114206-0144 200 [Section/Township/Parcel No. or Tax ID Number] TO BE COMPLETED BY ENGINEER, HEALTH DEPARTEMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINNEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. 0.14 PROPERTY SIZE CONFORMS TO SITE PLAN: [X] YES [ ] NO NET USABLE AREA AVAILABLE: TOTAL ESTIMATED SEWAGE FLOW: 200 GALLONS PER DAY [RESIDENCES -TABLE : " AUTHORIZED SEWAGE FLOW: SSO GALLONS PER DAY [1500 GPD/ACRE OR 2 00 GPD/ACRE] UNOBSTRUCTED AREA AVAILABLE: 450 SQFT UNOBSTRUCTED AREA REQUIRED: 300 SQFT BENCHMARK/REFERENCE POINT LOCATION: Top of tank ELEVATION OF PROPOSED SYSTEM SITE IS 6 [INCHES/FT] [ABOVE/BELOW] BENCMARX/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: N/A FT DITCHES/SWALES: N/A FT NORMALLY WET? [ ] YES [X] NO WELLS: PUBLIC: N/A FT ,LIMITED USE: N/A FT PRIVATE: 14/A FT NON -POTABLE: N/A FT BUILDING FOUNDATIONS: ,' FT PROPERTY LINES: 3' FT POTABLE WATER LINES: _90' FT ACRES SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [X] NO 10 YEAR FLOOD ELEVATION FOR SITE: N/A FT MSL/NGVD SITE ELEVATION: 10 YEAR FLOODING? [ ] YES [X] NO FT MSL/NGVD 4.00' per contour map sHWT• 4.00' per contour map sHWT• SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 MUNSELL 0/COLOR TEXTURE DEPTH 10yr 3/3 TO DARK DROWN FINE SAND 0 TO TO 4" TO TO 1 Oyr 8/3 POCKETS OF SAND IN TO VPD LIMESTONE • TO TO 72w TO USDA SOIL SERIES: MUNSELL #/COLOR TEXTURE 10yr 3/3 DARK DROWN 10yr 8/5 VPD FINE SAND DEPTH TO 0 TO TO 6" TO TO POCKETS OF SAND IN T° LIMESTONE 6" TO TO • To•72" USDA SOIL SERIES: • • ".• • • • OBSERVED WATER TABLE: N/A_ INCHES [ABOVE / BELOW] EXISTING GRADE. TYPE: / APPARENT] ESTIMATED WET SEASON WATER TABLE ELEVATION: t/' 72" INCHES [ABOVE / ffi ;•w4RXISTING.GRADE • HIGH WATER TABLE VEGETATION: [ ] YES [X] NO MOTTLING: [ ] YES [X] NO • DEPTH: N�'�: QHES • SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: EXISTING, • DRAINFIELD CONFIGURATION: I 1 TRENCHDEPTH OF EXC7►YAeION:'thSEg REMARKS/ADDITIONAL CRITERIA: LXX] BED [ ] OTHER (SPECIFY) •••••' ••• • • •••• • • SITE EVALUATED BY: GUILLERMO SUAREZ JR. DI 4015, 10/96 (Replaces RRS_g For* 4015 (page 31 which say be used) • • • • • • • • •• • • • 1 • STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM EXISTING SYSTEM AND SYSTEM REPAIR EVALUATION APPLICANT: Porto Carbral CONTRACTOR / AGENT: ALC EXCAVATORS, INC LOT: 4 BLOCK: 58 PERMIT a SUBDIV: Miami Shores sec me: 114206.0141200 TO BE COMPLETED BY FLORIDA REGISTERED ENGINEER, DEPARTMENT EMPLOYEE, SEPTIC TANK CONTRACTOR OR OTHER CERTIFIED PERSON. SIGN AND SEAL ALL SUBMITTED DOCUMENTS. COMPLETE ALL APPLICABLE ITEMS. COMPLETE TANK CERTIFICATION BELOW OR ATTACH LETTER FROM A PERMITTED SEPTAGE DISPOSAL SERVICE. EXIMNG UV ] GALLONSTANK IE T TION [IC TANK/GPD ATU LEGEND: UNKNOWN I ] GALLONS SEPTIC TANK/GPD ATU LEGEND: [ ] GALLONS GREASE INTERCEPTOR LEGEND: ] GALLONS DOSING TANK LEGEND: MATERIAL: CONCRETE_ BAFFLED:(Y / 11] MATERIAL: BAFFLED:(Y / N] MATERIAL: MATERIAL: r PUMPS:[ I CERTIFY THAT VOLUME 0 • ABOVE NOTED TANKS WERE PUMPED ON 11/9/15 , BY BUSY BEE SEPTIC HAVE THE , AS DETERMINED BY [ DIMENSION/ FILLING/LEGEND] ARE FREE OF OBSERVABLE DEFECT VE A [SOLIDS DEFLECTION DEVICE/ OUTLET FILTER DEVICE) INSTALLED. ALC EXCAVATORS, INC LICENSED CONTRACTOR E STING DRAINFIELD INFORMATION APPROX [ 175 BUSINESS NAME rox 10'x18' QUARE FEET PRIMARY DRAINFIELD SYSTEM I ] SQUARE FEET SYSTEM TYPE OF SYSTEM: [X] STANDARD [ ] FILLED ( J CONFIGURATION: [ ] TRENCH [X] BED [ J DESIGN: [X] HEADER [ ] D -BOX [X] GRAVITY SYSTEM 1 DOSED SYSTEM ELEVATION OF BOTTOM OF DRAINFIELD IN RELATION TO EXISTING GRADE 90 INCHES ( ABOVE / ] ] DATE NO. OF TRENCHES NO. OF TRENCHES MOUND ( ) APPROX DIMENSIONS: X DIMENSIONS: X SYSTEM FAILURE AND REPAIR INFORMATION [ 1959 200 ] SYSTEM INSTALLATION DATE TYPE OF WASTE [X] DOMESTIC [ ] COMMERCIAL ] GPD ESTIMATED SEWAGE FLOW BASED ON [ l METERED WATER [X] TABLE 1, 64E-6, FAC SITE [ ] DRAINAGE STRUCTURES CONDITIONS: [ ] SLOPING PROPERTY NATURE OF FAILURE: FAILURE SYMPTOM: [ HYDRAULIC OVERLOAD ] DRAINAGE / RUN OFF ] SEWAGE ON GROUND I ] PLUMBING BACKUP REMARKS/ADDITIONAL CRITERIA SUBMITTED BY: GUILLERMO t l (x1 [ l [ ] POOL ( ] PATIO / DECK GRASSY AREA SOILS ROOTS [ ] PARKING l MAINTENANCE ] WATER TABLE TANK [ ] D BOX/HEADER TANK NOT HOLDING WATER TITLE/LICENSE SM 890867 DH 4015, 10/96 (Previous Editions may be used) • I ) SYSTEM DAMAME I ]AmertimAcmg. 1 ] D :WIELD • • 0000 • • • • .w•-+.+0 ••0• • • .• •• • 0000 • • • • • • • • •• • • ••• DATE:L(11 15 Page 4 of 4 ••• • • • ••• • ••• • so • •• ••• • • • ••• • ••• • FOAM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 500 NE 92 ST (ENERGY FOR ADDITION ONLY) Builder Name: Street: 500 NE 92 ST Permit Office: City, State, Zip: MIAMI , FL , Permit Number: Owner: Jurisdiction: 231000 Design Location: FL, Miami 1. New construction or existing Addition 2. Single family or multiple family Single-family 3. Number of units, if multiple family 1 4. Number of Bedrooms(Bedrms In Addition) 1(0) 5. Is this a worst case? No 6. Conditioned floor area above grade (ft2) 310 Conditioned floor area below grade (ft2) 0 • 7. Windows 65.9 sqft.) Description Area a. U -Factor: Sgl, U=1.04 65.88 ft2 SHGC: SHGC=0.50 b. U -Factor: N/A ft2 SHGC: c. U -Factor: N/A ft2 SHGC: d. U -Factor: N/A ft2 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.500 8. Floor Types (310.0 sqft.) Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 310.00 ft2 b. N/A R= ft2 c. N/A R= ft2 9. Wall Types (570.0 sqft.) Insulation Area a. Concrete Block - Int Insul, Exterior R=3.0 570.00 ft2 b. N/A R= ft2 c. N/A R= ft2 d. N/A R= ft2 10. Ceiling Types (310.0 sqft.) Insulation Area a. Under Attic (Vented) R=19.0 310.00 ft2 b. N/A R= • ' ft2 • : 1 c. N/A • •. R• ft2 • • • •1 11. Ducts • • R• ft2 • a. Sup: Attic, Ret: Attic, AH: Attic • ..,S100 • • • ••••., •••• , 12. Cooling systems • • • • • • I•Btu/hr • 1`ficincy • a. Central Unit 40.0 S1tR'16.00 • • • • 1 • • • ••••I ••• .. • • • •.••I 13. Heating systems Jt Btu/hr Efficiency 4 a. Electric Strip Heat •• •• 34•.0 CO• P :1.00 •4 •SHGC: ••••i • • • • 14. Hot water systems - None required• • • • • • • • a. •• •cap N/A EF: -9.67141E024 b. Conservation features 15. Credits Pstat Glass/Floor Area: 0.213 Total Proposed Modified Loads: 20.27 PASS *errTotajl,Baseline Loads: 23.44 I hereby certify that the plans and sp ifis. cat�onp• 6y•°• `S `'. this calculation are in complian _� , `:; of.e., er. , S °. 4` Code. rt.3� o PREPARED BY: , . Review of the plans and S Specifications covered by this ©,+'� calculation indicates compliance 'r,i, �'�"t4�+. !pith the Florida Energy Code. - 'a,,, , - „ 0 a-Pefore construction is completed' c =n ?tti'is building will be inspected for _ A compliance with Section 553.908 ;' • Iorida Statutes. 1 ' •••• •S r' ".• 5 r CaD W1rItt ,,• DATF-: O , ,•S-(P� • (r ' '�•'' • I hereby certify that this building, as designed 'is in pmiatiR5e•• with the Florida Energy Code. '',, 0,c •' • • • • • • ' •�.,� �l'°�SS �DN�'`�� OWNER/AGENT: BUILDING OFFICIAL _ __ DATE DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 9/23/2015 6:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 PROJECT Title: 500 NE 92 ST (ENERGY FO Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 310 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 500 NE 92 ST Permit Office: Cross Ventilation: No County: Miami -Dade Jurisdiction: 231000 Whole House Fan: No City, State, Zip: MIAMI , Family Type: Single-family FL , New/Existing: Addition Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Miami FL_ MIAMI_INTL_AP 1 51 90 70 75 149.5 . 56 • Low BLOCKS •• • •••• • • • •••• ....1 Number Name Area Volume•11111••• • • • 1 Block1 310 3100 •••••• •'•••• . SPACES••• ••, Number Name Area Volume Kitchen Occupants Bedrooms Infil Ip• • Fjpyshed Cgoled Heated 'I • • • 1 AC 1 310 3100 Yes 5 1 1 • Yes ;.YeS. 's••1 • • FLOORS • • • • • • • • V# Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 144 ft 0 310 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Barrel tile 336 ft2 64 ft2 Dark 0.96 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 310 ft2 N N CEILING # Ceiling Type Space R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 19 310 ft2 0.11 Wood 9/23/2015 6:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 9/23/2015 6:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 WALLS / Adjacent V # Ornt Tn Wall Type Space Cavity Width Height R -Value Ft In Ft Sheathing Framing Solar In Area B_VahiP Fraction Ahsnr 0 230.0 ft2 0 0 0.3 0 130.0 ft2 0 0 0.3 0 210.0 ft2 0 0 0.3 Below Grade% 0 0 0 1 W Exterior Concrete Block - Int Insul AC 1 2 S Exterior Concrete Block - Int Insul AC 1 3 E Exterior Concrete Block - Int Insul AC 1 3 23 10 3 13 0 10 3 21 10 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall # Omt ID Frame Panes NFRC U -Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 W 1 Metal Single (Clear) Yes 1.04 0.5 1.04 0.5 1.04 0.5 13.5 ft2 1 ft 0 in 1 ft 0 in None 39.0 ft2 1 ft 0 in 1 ft 0 in None 13.5 ft2 1 ft 0 in 1 ft 0 in None None None None 2 S 2 Metal Single (Clear) Yes 3 E 3 Metal Single (Clear) Yes INFILTRATION • # Scope Method SLA • CFM 50 ELA EqLA ACH • •ACID 50 ."••• ••••__•_•___. /v.-. •... • i 1 Wholehouse Proposed CFM(50) .000098 80 4.39 8.26 .0679 •••:116684 . __ -- •rr•i . ••••i HEATING SYSTEM • • •••• ...• •... # System Type Subtype Efficiency Capacity .. • •. • • eft. • Duct sys#1 • 1 Electric Strip Heat None COP:1 34 kBtu/hr 1. • • • COOLING SYSTEM • • • • • • ....I V # System Type Subtype Efficiency Capacity Air Flow SHR •BlOck• Ducts 1 Central Unit Split SEER: 16 40 kBtu/hr 1200 cfm 0.75 1 sys#1 SOLAR HOT WATER SYSTEM V FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF ft2 DUCTS V --- Supply --- Return # Location R -Value Area Location Area Leakage Type Air CFM 25 CFM25 Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 100 ft2 Attic 15 ft2 Default Leakage Attic (Default) (Default) 1 1 9/23/2015 6:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [X Jan [X Feb `X Mar X Apr X May X Jun X Jul X Aug X Sep X Oct X Nov X Dec Heating lX Jan lX Feb lX Mar XX Apr X May X X Jun �Jun XX Jul X] Aug XX Sep Oct Nov Dec XX Oct X Nov XX Dec Venting X Jan X Feb X Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/23/2015 6:19 AM • • • • • •• • • •••• • •••• • • •• • • • • • • • • •• • • • •••• •••• •• • . • •••• • •••• • • . • • • • • •• • • • ••• • • • • EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 500 NE 92 ST (ENERGY FOR ADDITION ONLY) Builder Name: Street: 500 NE 92 ST Permit Office: City, State, Zip: MIAMI , FL , Permit Number: Owner: Jurisdiction: 231000 Design Location: FL, Miami COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned • attic spaces shall be sealed. • • ••••••• • •••• • • _ • • Walls Corners and headers shall be insulated and the junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall badged, Exterior thermal envelope insulation for framed walls shall be instglILd1n substantial contact and continuous alignment with the air barrier. • • Knee walls shall be sealed. • • • • •"' •' ' • • • • • • • • • • • • • • • • • 111 • • • • • • Windows, skylights and doors The space between window/door jambs and framing and skylights ar?d : framing shall be sealed.• •Rim • •• • • • • • • • • • joists Rim joists are insulated and include an air barrier. • Floors (including above -garage and cantilevered floors) Insulation shall be installed to maintain permanent contact with underside of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. •• • Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/23/2015 6:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 •••• • .• •••• • •••• • • • ••• •••• • •••• • • FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 86 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" a. U -Factor: SHGC: b. U -Factor: SHGC: c. U -Factor: SHGC: d. U -Factor: SHGC: Area Weighted Average Area Weighted Average 8. Floor Types a. Slab -On -Grade Edge b. N/A c. N/A Description Sgl, U=1.04 SHGC=0.50 N/A N/A N/A Overhang Depth: SHGC: Insulation 500 NE 92 ST, MIAMI, FL, Addition Single-family 1 1(0) No 310 Area 9. Wall Types Insulation Area a. Concrete Block - Int Insul, Exterior R=3.0 570.00 ft2 b. N/A R= c. N/A R= d. N/A R= 10. Ceiling Types Insulation Area a. Under Attic (Vented) R=19.0 • 310.00 ft2 b. N/A • R= • ft2 c. N/A ••••R•1 ft2 ft2 ft2 •••• ft2 65.88 ft2 11. Ducts ••�R• ft2 a. Sup: Attic, Ret: Attic, AH: Attic • • •• 100 • ft2 ••a• ••••• 12. Cooling systems • • • • •kBtu/hr Efficiency ft2 a. Central Unit 40.0 $EER j6.00 • • • • •• • ft2 1.000 ft. 0.500 Insulation Area R=0.0 310.00 ft2 R= R= ft2 ft2 13. Heating systems • , li' to/hr Efftiency a. Electric Strip Heat • • 34.00 COP:1.00 • ••• • •• • 14. Hot water systems - None required a. b. Conservation features 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: • ••• • • Cap!N/A EF: Pstat • • • • *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/23/2015 6:20 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 Wind s(46.7%), Residential System Sizing Calculation Summary Project Title: 500 NE 92 ST (MANUAL J FOR WHOLE HOUSE) 500 NE 92 ST MIAMI, FL 9/23/2015 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(7 ft.) Temp Range(L) Humidity data: Interior RH (50%) Outdoor wet bulb (77F) Humidity difference(56qr.) Winter design temperature(TMY3 99%) 49 Winter setpoint 70 Winter temperature difference 21 F F F Summer design temperature(TMY3 99%) 92 Summer setpoint 75 Summer temperature difference 17 F F F Total heating load calculation 23852 Btuh Total cooling load calculation 39868 Btuh Submitted heating capacity % of calc Total (Electric Strip Heat) 142.5 Btuh 34000 Submitted cooling capacity % of calc Sensible (SHR = 0.75) 86.4 Latent • .194.3 Total 6. • • '000.3 Btuh p000Q :0088• 41;DDD WINTER CALCULATIONS Winter Heatino Load (for 1645 soft Load component Load Load Window total 250 Window total 250 sqft 5809 Btuh Wall total 1859 sqft 6970 Btuh Door total 21 sqft 203 Btuh Ceiling total 1645 sqft 1693 Btuh Floor total 1645 sqft 5476 Btuh Infiltration 112 cfm 2596 Btuh Duct loss Sens. Ventilation 0 cfm 1104 Btuh Subtotal 0 23852 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS Btuh Latent gain(infiltration) 23852 Btuh Summer Coolino Load (for 1645 soft Ceilings(7.1%) Wallsl29.2% SUMMER CALCULATION Load component Load Window total 250 sqft 18605 Btuh Wall total 1859 sqft 5642 Btuh Door total 21 sqft 202 Btuh Ceiling total 1645 sqft 2903 Btuh Floor total 0 Btuh Infiltration 101 cfm 1897 Btuh Internal gain 4550 Btuh Duct gain 923 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 34722 Btuh Latent gain(ducts) 284 Btuh Latent gain(infiltration) 3862 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internal/occupants/other) 1000 Btuh Total latent gain 5146 Btuh TOTAL HEAT GAIN 39868 Btuh 8th Edition Ceilings(7.3%) • •••• • • •••• • • •••• • • • •••• • • • • •••• Infil.(10.9 `Doors(0:9* I Walls(14.2%) Doors(0.5%) Latent int(2.5%) Int.Ga n(11.4%) Ducts(3.0%) Infil.(14.4%) e EnergyGauge® System Sizing PREPARED BY: DATE: EnergyGauge® / USRFZB v4.0 • • • • • •