PW-17-2162Project Address
Miami Shores Village
10050 N.E. 2nd Avenue
Miami Shores, FL 33138-0000
Phone: (305)795-2204
465 GRAND CONCOURSE
Miami Shores, FL
Owner Information
JULIAN & DEBRA MONTERO
Permit
Address
Parcel Number
Permit NO. PW -8-17-2162
Permit Type: Public Works
Work Classification: Public Works
Permit Status: APPROVED
Issue Date: $/29/2017
1132060170320
Block: Lot:
465 GRAND CONCOURSE
MIAMI SHORES FL 33138-2462
Expiration: 11/27/2017
Applicant
JULIAN & DEBRA MONTERO
Contractor(s) Phone Cell Phone
TECO PEOPLES GAS SYSTEM (305)957-3857 (305)970-1783
Phone
305/685-0412
Cell
Valuation:
Total Sq Feet:
$ 1,000.00
0
Scanning: 1
Fees Due
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee
Scanning Fee
Technology Fee
Total:
Amount
$0.00
$0.00
$0.00
$0.20
$100.00
$3.00
$0.80
$104.00
Pay Date Pay Type
Invoice # PW -8-17-64998
08/29/2017 Credit Card
08/28/2017 Check #: 1592
Amt Paid Amt Due
$ 54.00 $ 50.00
$ 50.00 $ 0.00
Available Inspections:
Inspection Type:
Excavation
Review Public Works
Final Public Works
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing informa
construction and zoning. Futhermore, I authorize the above-
Authorized Signature: Owner / Applicant
Building Department Copy
• is
:m r.
ccurat
• ac
and that all work will be done in compliance with all applicable laws regulating
r to do the work stated.
/ Agent
August 29, 2017
Date
August 29, 2017 1
'IVliami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
RECEIVED
AUG 2 8 2017
sol
FBC 20N
BUILDING Master Permit No.RA-3I1—a 1 SOP
PERMIT APPLICATION Sub Permit No. pit) )2 - j !o - 3 4f2 9
❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
111 PLUMBING ❑ MECHANICAL (PUBLIC WORKS ❑ CHANGE OF n CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: %/ r� G �cJ G G u 2 S
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: Is the Building Historically Designated: Yes NO X
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): RIGHT OF WAY Phone#:
Address:
City: State:
Zip:
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: TECO PEOPLES GAS Phone#: 954-453-0806
Address: 5101 NW 21 AVE. STE. 460
City: FT. LAUDERDALE
Qualifier Name:
JESUS VEGA
State: FL Zip: 33309
Phone#: 954-453-0806
State Certification or Registration #: E1608 Certificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ 1000 Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ lace Re air Re
P / P n Demolition
Description of Work: PERMIT RE -NEW FOR A GAS SERVICE LINE
Specify color of color thru tile:
Submittal Fee $ O' 6D Permit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $ Bond $
TOTAL FEE NOW DUE $ 5y . 00
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City State
Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature Signature 3-Q2.sq
OWNER or AGENT
CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of , 20 , by 2.3 day of , 20 ) 7 , by
, who is personally known to , wh rsona y nown to)
me or who has produced as me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
.
!!
NOTAR IC:
O',,identificat'
nd who did take an oath.
Print:
Seal:
APPROVED BY Plans Examiner
(Revised02/24/2014)
as
HUB
MY COMMISSION # GG 104234
EXPIRES: September 11, 2021
Bonded Thru Notary Public Underwriters
*************************
Zoning
Structural Review Clerk
Arlenis Silvera
From: Arlenis Silvera
Sent: Monday, May 01, 2017 4:05 PM
To: 'alfinch@tecoenergy.com'
Subject: PW -12-16-3429
Good Day,
Please be advise that Permit#: PW -12-16-3429 does not have a final inspection. Please advise when you are
ready for inspections.
Best Regards,
Arlenis Silvera
Permit Clerk Supervisor
Miami Shores Village
10050 NE 2 AVE
Miami Shores, FI 33138
305-795-2204
www.miamishoresvillage.com
1
• • ••• • • • •••
•• -
•• •• • • • ••
• • • • •• • • - • ••
• • •• •••• •• • • •-
• •• •• • •• •
- •
J�
J L
•
• • ••• • • •
••-
• •
•
•
• •
••
200 200 400
•
•
•
T.J L 4i •.J ••Ito• ••
• •• • • - • •
• ••.0 • • •
(Less Than
r 200
/P//"//771.
Work Area ■
JJL J
b l 1 1
03
I r 400'I r sa ■ ■ I
SYMBOLS
MWork Area
/ Work Area /
■ Channelizing Device (See Index No. 600)
Qt Work Zone Sign
• Flagger
b Lane Identification + Direction of Traffic
200'
200
More Than
200'
GENERAL
1. Work operations shall be confined to one travel lane, leaving
the opposing travel lane open to traffic.
2. When vehicles in a parking zone block the line of sight to TCZ
signs or when TCZ signs encroach on a normal pedestrian
walkway. the signs shall be post mounted and located in
accordance with Index No. 17302.
3. If work area is confined to an outside auxiliary lane, the work
area shall be barricaded and the FLAGGER signs replaced by
ROAD WORK AHEAD signs. Flaggers are not required.
4. Flaggers shall be in sight of each other or in direct
communication at all times.
•
r .n• •r .•
L
JL
NOTES
5. The FLAGGER legend sign may be substituted for the symbol sign.
6. The maximum spacing between devices shall be no greater than 25.'
7. For general TCZ requirements and additional information, refer to
Index No. 600.
8. The two channelizing devices directly in front and directly at the
end of the work area may be omitted provided vehicles in the work
area have high-intensity rotating, flashing, oscillating, or strobe
lights operating.
9. Use Temporary Raised Rumble Strips in accordance with Index 603.
Placement of Rumble Strips and additional signs should begin at
FLAGGER sign location.
• ••
•• •
• ••
• • •
• • -
••••
•
CONDITIONS
•AIIERE AP VEHICLE, EQUIPMENT, WORKERS
O an THEI ACTIVITIES ENCROACH ON THE
:PAVEMENT SEOUIRING THE CLOSURE OF ONE
•TRAFFIC LADE, FOR WORK AREAS LESS THAN
.I D•A0VSTREAM FROM AN INTERSECTION
FOR A PERIOD OF MORE THAN 60 MINUTES.
CONDITIONS
WHERE ANY VEHICLE, EQUIPMENT, WORKERS
OR THEIR ACTIVITIES ENCROACH ON THE
PAVEMENT REQUIRING THE CLOSURE OF ONE
TRAFFIC LANE, FOR WORK AREAS 200' OR
MORE DOWNSTREAM FROM AN INTERSECTION
FOR A PERIOD OF MORE THAN 60 MINUTES.
DURATION NOTES
1. ROAD WORK AHEAD sign may be omitted if all of the following
conditions are met:
a. Work operations are 60 minutes or less.
b. Speed is 45 mph or less.
c. No sight obstructions to vehicles approaching the work area for
a distance of 600 feet.
d. Vehicles in the work area have high-intensity. rotating,
flashing, oscillating, or strobe lights operating.
e. Volume and complexity of the roadway has been considered.
LAST
REVISION
07/01/15
2
0
S
DESCRIPTION:
FDOT
•
2016
DESIGN STANDARDS
TWO-LANE, TWO-WAY, WORK NEAR )INTERSECTION
INDEX
NO.
605
SHEET
NO.
1of1
\
•
.
S.
• • .
• SCAL:'I•=30' • .••.
▪ . .
• •
• •
• l •
EX. 2" BSE. CS. GA
MAIN
•41E. 4N SVG •4-O A GM�4IN
�W 4 T/J'/ F.'ABS E. FIV••6 •
• ••••
• • • • .•••
•
•
••
.
••
• •
• •••
•••.
• •
.•.•
•
• •
4'
L
•
•
•
•
•
•
•
•
•
\
\
ALL EXISTING UTILITIES SHOWN ON
THESE PLANS ARE TO BE
CONSIDERED APPROXIMATE &
SHOULD BE VERIFIED BY THE
CONTRACTOR PRIOR TO THE
START OF WORK OPERATIONS.
5
95.5'
FULL LANE
SURFACE REPLACEMENT
SURFACE
SAW CUT ASPHALT
(TYPICAL)
PROP. 3/4" PLASTIC
GAS SVC. DIRECTIONAL
BORE
PROP. RISER WITH 3/4"
PLASTIC GAS SVC.
GENERAL NOTES
1. REPLACE BASE MATERIAL OVER DITCH SHALL BE TWICE THE
THICKNESS OF THE BASE. MIN. 8" AND MAX. 18"
2. BASE MATERIAL SHALL BE PLACE IN 6" MAX. (LOOSE MEASUREMENT)
LAYER AND EACH LAYER THOROUGHLY ROLLED OR TAMPED TO 98% OF
MAX. DENSITY PER AASHTO T-180
3. ASPHALT CONCRETE PAVEMENT JOINTS SHALL BE MECHANICALLY SAWED
4. SURFACE MATERIAL SHALL BE CONSISTENT WITH SURROUNDING SURFACE
MATERIAL
5. BASE MATERIAL SHALL HAVE A MIN. LBR. OF 100 AND A MIN. CARBONATE
CONTENT OF 70% (60% FOR LOCAL STREETS)
6. CONTRACTOR SHALL SOFT DIG TO VERIFY LOCATION OF EXISTING UTILITIES
7. ALL ROADWAY RESTORATION WITHIN F.D.O.T R/W SHALL COMPLY WITH INDEX
310.
12
LEGEND
CENTER LINE
MONUMENT UNE
RIGHT OF WAY
PROPERTY LINE
EDGE OF PAVEMENT
TAPPING TEE
EXCESS FLOW VALVE
SERVICE LINE
WATER MAIN
R/W
P/L
E.O.P.
T.T.
E.F.V.
SVC
WM.
RECIP!T VT:
JUL 1g 010
BY:
REPLACEMENT BASE
(NEW MATERIAL)
12'
RESTORATION OF ROAD CUT
FOR UTILITY CROSSING
8
15'
ROP.3/4" PLASTIC
8
EX. GRD
GAS SVC. TO BE
Ce
a
a
\ DIRECTIONAL BORED
rr
z,
0
w
0
W
N
4
36" MIN.
4
1
1
w
_ — _
— cAs
-As _
EX4"BSE. CS
O
GA9 MAIN
O
FROFILE CROSSING ALLEY WAY
: (V) 1:5 lr1) INIJ.
0
ate', ai
07-05-2018
z
RR
PROJECT ADDRESS:
CO
m
0 g
U
z
0
U
0
Eti
IV
N
w
J
a
0
w
a
0
rn
x
NO. OF SH1iars.1
sHEar NO.: 1
Drawing File: C: \Users\stbxj\Desktop\Marlen Cabrera\JOBS\465 GRAND CONCOURSE MIAMI SHORE FL 33138\465 GRAND CONCOURSE MIAMI SHORES 33138.dwg 07/06/2016