Loading...
MC-17-2143Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Parcel Number 2017 Expiration: 03/18/2018 Applicant 11300 NE 2 Avenue Number: Renne M. Hall 1121360000050-20 Miami Shores, FL 33138-0000 Block: Lot: BARRY UNIVERSITY INC Owner Information Address Phone CeII BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractor(s) AIR DUCT ASEPTICS Phone (954)979-4996 CeII Phone anMftmmMMMEMaft Valuation: Total Sq Feet: $ 5,043.00 0 Tons: Additional Info: FURNISH AND INSTALL 1 RHEEM 4- TON, Classification: Commercial Approved: In Review Comments: Date Denied: Scanning: 3 Date Approved:: In Review Type of Work: Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee Scanning Fee Technology Fee Total: Amount $3.60 $2.27 $2.27 $1.20 3151.29 39.00 $4.80 $174.43 Pay Date Pay Type Invoice # MC -8-17-64979 08/24/2017 Credit Card 09/19/2017 Credit Card Amt Paid Amt Due $ 50.00 $ 124.43 $ 124.43 $ 0.00 Available Inspections: Inspection Type: Final Review Mechanical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFI DA . T: I cerlify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction oping. F ermore, I authorize the above-named contractor to do the work stated. uthorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy September 19, 2017 Date September 19, 2017 1 &*-S ')) 0 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ PLUMBING [.MECHANICAL ❑ PUBLIC WORKS JOB ADDRESS: / / 300 NG 2 na A \er) U - City: Miami Shores County: � FBC 20 N5_ Master Permit No. I " lL I -2] -} Sub Permit No. ❑ REVISION ❑ CHANGE OF CONTRACTOR ®SNA ❑ EXTENSION ❑RENEWAL ❑ CANCELLATION ❑ SHOP DRAWINGS .1\4 , 1-1Wc11 I Miami Dade Zip: 3 31(.0 Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: OWNER: Name (Fee Simple Titleholder): T3 r Un 11I Address: ) i1 3 00 12r e V NO BFE: FFE: Phone#: ,305- 3 `5-(o gicC,, city: rn) o m i shore State: r(Gil G/ Zip: 3 3 ! (n / Tenant/Lessee Name: Phone#: 2'() J_ -31 b -co mo ch�llida�eIx rrL3-edtk Email: CONTRACTOR: Company Name: Ai r w c4 ill S C. 5 Address: C 6-7 n ta.3 315 P- V e n u -e., Phone#: q 51-1—g qq l[� city: pbVvpQnO 6c -con State: -F1QY 1 d G Zip: 33G409 Qualifier Name: Te-hri nrt Te -06 Y"' Phone#: q5 u--q%ct-ygq State Certification or Registration #: CACcs --) 5-5- 0 Certificate of Competency #: CAC 0 37550 DESIGNER: Architect/Engineer: Phone#: Address: City: i Value of Work for this Permit: $ 6/ vy 3 . 0 a; Square/Linear Footage of Work: State: Zip: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Jrnish and -Th S*Q// (i) Rl7ee1ri q-10-7 j /Se e r c i t handiev- Will avac/ 60ricie4 Se✓ Specify color r O u tile; Submittal Fee $ 5:(5,a ' , Permii-? y S' /2A CCF $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ 12-4 ` '43 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be .performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7j days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur � OWNER or AGENT The foregoing instrument was acknowledged before me this TMU sdAay' of AtA f 1 ,20 1-7 , by V b �,N U4Y1 , who is personally known to , m .or who has produced as identification and who did take an oath. NOTARY PUB IC: Sign: Print: Seal: Notary Publics State of Florida Jeffry J Yao ` My Commission FF 168481 res 11/12/2018 * * * *..i. *.*;`i`': * APPROVED BY (Revised02/24/2014) r txj fi �� i*ii *ii*iii Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of A/5U '> , 20 , by c(u , who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLI Sign: Print: Seal: 771) 4 Plans Examiner SANLI-k2 Julio Sanchez Jr. COMMISSION giSCORIOS EXPIRES: April 30, 2021 *APPAQ1104 RY0,i**iii**i*ii* Zoning Structural Review Clerk Property Search Application - Miami -Dade County Page 1 of 1 OFFICE OF THE PROPERTY APPRAISER Summary Report Property Information Folio: 11-2136-000-0050 Property Address: 11300 NE 2 AVE Miami Shores, FL 33161-6628 Owner BARRY COLLEGE Mailing Address 11300 NE 2 AVE MIAMI SHORES, FL 33161-6628 PA Primary Zone 8200 SCHOOLS & CHURCHES Primary Land Use 7241 EDUCATIONAL/SCIENTIFIC - EX : EDUCATIONAL - PRIVATE Beds / Baths / Half 0 /0 /0 Floors 2 Living Units 66 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 623,362 Sq.Ft Lot Size 1,740,400 Sq.Ft Year Built 1954 Assessment Information Year 2017 2016 2015 Land Value $6,961,600 $6,961,600 $6,961,600 Building Value $38,439,360 $36,913,434 $33,497,476 XF Value $2,607,248 $2,628,780 $2,554,483 Market Value $48,008,208 $46,503,814 $43,013,559 Assessed Value $48,008,208 $46,503,814 $43,013,559 Benefits Information Benefit Type 2017 2016 2015 Educational Exemption $48,008,208 $46,503,814 $43,013,559 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description 36 52 41 40 AC SE1/4 OF NE1/4 LESS E35FT & LESS W4OFT LOT SIZE 1740400 SQUARE FEET Generated On : 8/17/2017 12,T 1.1,441 Taxable Value Information 2017 2016 2015 County Exemption Value $48,008,208 $46,503,814 $43,013,559 Taxable Value $0 $0 $0 School Board Exemption Value $48,008,208 $46,503,814 $43,013,559 Taxable Value $0 $0 $0 City Exemption Value $48,008,208 $46,503,814 $43,013,559 Taxable Value $0 $0 $0 Regional Exemption Value $48,008,208 $46,503,814 $43,013,559 Taxable Value $0 $0 $0 Sales Information Previous Sale Price OR Book -Page Qualification Description The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: http://wvvw.miamidade.gov/propertysearch/ 8/17/2017 2017 FLORIDA NOT FOR PROFIT CORPORATION ANNUAL REPORT FILED DOCUMENT# 711458 Apr 27, 2017 Entity Name: BARRY UNIVERSITY, INC. Secretary of State CC2519040112 Current Principal Place of Business: 11300 N.E. SECOND AVENUE ROOM 105 FARRELL HALL MIAMI, FL 33161 Current Mailing Address: 11300 N.E. SECOND AVENUE ROOM 105, FARRELL HALL MIAMI, FL 33161 FEI Number: 59-0624364 Name and Address of Current Registered Agent: DUDGEON, DAVID 11300 NE SECOND AVE LAVOIE HALL #209 MIAMI, FL 33161 US Certificate of Status Desired: No The above named entity submits this statement for the purpose of changing its registered office or registered agent, or both, in the State of Florida. SIGNATURE: Electronic Signature of Registered Agent Officer/Director Detail : Title S Title T Name DUDGEON, DAVID Name ROSENTHAL, SUSAN Address 11300 NE SECOND AVE Address 11300 N.E. SECOND AVENUE City -State -Zip: MIAMI FL 33161 City -State -Zip: MIAMI FL 33161 Title D Title PD Name BUSSEL, JOHN Name BEVILACQUA, SISTER LINDA Address 11300 NE SECOND AVE Address 11300 NE SECOND AVE City -State -Zip: MIAMI FL 33161 City -State -Zip: MIAMI FL 33161 Title VP Name MURRAY, JOHN Address 11300 N.E. SECOND AVENUE City -State -Zip: MIAMI FL 33161 Date I hereby certify that the information indicated on this report or supplemental report is true and accurate and that my electronic signature shall have the same legal effect as if made under oath; that I am an officer or director of the corporation or the receiver or trustee empowered to execute this report as required by Chapter 617, Florida Statutes; and that my name appears above, or on an attachment with all other like empowered. SIGNATURE: DAVID DUDGEON GENERAL COUNSEL/SECRETARY 04/27/2017 Electronic Signature of Signing Officer/Director Detail Date AIR DUCT ASEPTICS SENSIBLE AIR SOLUTIONS BY InmeidlIMIBY CERTIFIED PROFESSIONALS PROPOSAL FOR HVAC EQUIPMENT REPLACMENT AND DUCTWORK CLEANING Barry University, 11300 NE 2°d Avenue, Miami Shores, Florida August 9, 2017 All equipment and material will be new, first quality, and installed according to accepted engineering practice. Any alteration or deviation from above proposal and bid documents involving extra costs will be executed only upon orders, and will become an extra charge. The warranties provided herein are expressly in lieu of all other warranties or obligations expressed or implied and it neither assumes nor authorizes, any other person to assume for it, any liability in connection with the sale of this equipment. All warranty calls will be made during normal working hours Monday through Saturday. Emergency calls made after normal hours will be charged at the rate of difference between straight time and overtime. Ownership of the above equipment and materials shall remain in sellers' name and title is hereby retained until fully paid. In the event payment is not made within the time and manner as set forth below, at its' option, may remove said equipment. It is agreed that the seller shall not be responsible for any loss, damage or delay caused by malfunctioning equipment, acts of Government, strikes, lockouts, fire, explosion, theft, floods, rain, water damage, riot, civil commotion, war, nuclear disaster, malicious mischief, acts of God or by any cause beyond it's control and in any event for consequential damages. Any hidden conditions not identified in this proposal and discovered during the course of permitting and inspections are additional to this proposal and not included. Seller may withdraw this proposal if not accepted within 30 days. Non-refundable costs for permitting and heat load calculations apply to this project if terminated prior to installation and will be deducted from deposit received. Any costs incurred as a result of nonpayment of billing including court costs and purchaser will sustain attorneys' fees. (888) 707-7763 Visit us online at www.ADAFlorida.com CAC057550 - MRSA1924 - MRSR802 FEII:q ASDUCT E SENSIBLE AIR SOLUTIONS BY Irminsi CERTIFIED PROFESSIONALS PROPOSAL FOR HVAC EQUIPMENT REPLACMENT AND DUCTWORK CLEANING Barry University, 11300 NE 2nd Avenue, Miami Shores, Florida August 9, 2017 HVAC Equipment Replacement Scope of Work: We propose to furnish and install the following: Furnish and install one (1) Rheem 4 -ton, 14 SEER air handler unit and condenser unit to replace existing Rheem units Includes 10kW heat Includes programmable thermostat Includes float switch Connected to existing refrigerant lines, drainage, electrical Connected to existing ductwork and drainage Connected to existing platform/stand Connected to existing exterior slab Labor warranty for 1 year during normal business hours (excluding holidays) Manufacturers' 10 year parts warranty with registration of unit. Permitting included TOTAL COST $5,043 Terms: No deposit 100% upon completion Limitations: This quotation is to replace the existing HVAC equipment with the same size and SEER unit. Any alterations to the HVAC configuration, including ductwork are not included with our proposal. Heat load calculations have not been performed; calculations are not included with this proposal and are available upon request. (888) 707-7763 Visit us online at www.ADAFIorida.com CAC057550 - MRSA1924 - MRSR802 DATE: 08.11.17 TRANSMITTAL TO: Air Duct Aseptics REF: Doss - AC Unit 937 NW 31st Ave Pompano Beach, FL 33069 ATTN: SENT VIA: Pick -Up Barry University Facilities Management 11600 NE 2nd Avenue Suite #15 Miami, Florida 33161 Telephone (305) 899-3785 Facsimile (305) 899-3794 www.barry.edu No. DATE No. COPIES DESCRIPTION 1 08.11.17 1 1 -Signed MDC - Mechanical Permit App - Doss AC Received by: Print Date COMMENTS: cc: SENT BY: Jeff Yao Construction Manager ACCORD® CERTIFICATE OF LIABILITY INSURANCE `� DATE(MMIDDIYYYY) 8/24/2017 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Silk Insurance Services�NNo, 1000 Germantown Pike Suite a-4 Plymouth Meeting PA 19462 CONTACT Amanda Moser NAME: ). (610) 994-8600 (J No): (610)994-8704 ADDRELSS:amoser@thesilkcompanies.com INSURER(S) AFFORDING COVERAGE NAIC INSURERAColony Insurance Company COMMERCIAL GENERAL LIABILITY INSURED Air Duct Aseptics 937 NW 31st Avenue Pompano Beach FL 33069 INSURER B : PACEP306548 INSURERC: 12/31/2017 INSURERD: $ 1,000,000 INSURER E : INSURERF: x COVERAGES CERTIFICATE NUMBER:CL16122300263 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL INSD SUBR WVLIMBS D POUCY NUMBER POLICY EFF (MMIDDIYYYY) POUCY EXP (MMIDDIYYYYI A x COMMERCIAL GENERAL LIABILITY PACEP306548 12/31/2016 12/31/2017 EACH OCCURRENCE $ 1,000,000 CLAIMS -MADE x OCCUR DAMAGE TO RENTED PREMISES occurrence) $ 50,000 MED EXP (Any one person) $ 5,000 PERSONAL BADV INJURY $ 1,000,000 GEM_ X AGGREGATE POUCY OTHER: LIMIT APPUES JET PER LOC GENERAL AGGREGATE $ 2,000,000 PRODUCTS-COMP/OPAGG $ 2,000,000 $ AUTOMOBILE LIABILITY ANY AUTO ALL OWNED AUTOS HIRED AUTOS SCHEDULED AUTOS NON -OWNED AUTOS COMBINED SINGLE UMIT (Ea accident) $ BODILY INJURY (Per person) $ BODILY INJURY (Per accident) $ PROPERTY DAMAGE (Per accident) $ $ UMBRELLA UAB EXCESS UAB OCCUR CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ DED RETENTION $ $ WORKERS COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? (Mandatory In NH) If yes, describe under DESCRIPTION OF OPERATIONS below Y / N N / A PER STATUTE OTH- ER E.L EACH ACCIDENT $ E.L DISEASE - EA EMPLOYEE $ E.L DISEASE - POUCY OMIT $ A A Pollution Liability Professional Liability PACEP306548 PACEP306548 12/31/2016 12/31/2016 12/31/2017 12/31/2017 $1,000,000 Each Occ $2,000,000 AGG $1,000,000 Each Occ $2,000,000 AGG DESCRIPTION OF OPERATIONS 1 LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached If more space Is required) Class A Air Conditioning Contractor License #: CAC057550 CERTIFICATE HOLDER CANCELLATION Miami Shores Village Bldg Dept 10050 NE 2nd Ave Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Ronald Wilk/AM ACORD 25 (2014/01) 1NS025 (9014011 © 1988-2014 ACORD CORPORATION. AH rights reserved. The ACORD name and logo are registered marks of ACORD AIR DUCT ASEPTICS SENSIBLE AIR SOLUTIONS BY CEFi11FIFG PRWSSIONAI S PROPOSAL FOR HVAC EQUIPMENT REPLACMENT AND DUCTWORK CLEANING Barry University, 11300 NE 2nd Avenue, Miami Shores, Florida August 9, 2017 HVAC Eauipment Replacement Scope of Work: We propose to furnish and install the following: Furnish and install one (1) Rheem 4 -ton, 14 SEER air handler unit and condenser unit to replace existing Rheem units Includes 10kW heat Includes programmable thermostat Includes float switch Connected to existing refrigerant lines, drainage, electrical Connected to existing ductwork and drainage Connected to existing platform/stand Connected to existing exterior slab Labor warranty for 1 year during normal business hours (excluding holidays) Manufacturers' 10 year parts warranty with registration of unit. Permitting included TOTAL COST $5,043 Terms: No deposit 100% upon completion Limitations: This quotation is to replace the existing HVAC equipment with the same size and SEER unit. Any alterations to the HVAC configuration, including ductwork are not included with our proposal. Heat load calculations have not been performed; calculations are not included with this proposal and are available upon request. (888) 707-7763 Visit us online at www.ADAFlorida.com CAC057550 - MRSA1924 - MRSR802 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax:(305) 756.8972 AIR CONDITIONING REPLACEMENT DATA PERMIT NUMBER: MC This form must accompany ALL air conditioning replacement permit applications. Each unit change -out must be on its own data sheet. Multiple units on single sheets are not acceptable. Job Address (where the work is being done): garb li n' ye61 y, 11,300 IVE 2nd ame, City: Miami Shores Village County: Miami Dade Zip Code: :3 31 to ( ALL CONDENSING UNITS MUST BE ON A 4 INCH SOLID CONCRETE SLAB ALL UNITS MUST COMPLY WITH F.E.M.A MINIMUM FLOOD ELEVATION A COPY OF THE CONTRACT IS REQUIRED WITH ALL SUBMITALS AHRI DATA SHEET REQUIRED Change disconnecting means: YES ❑ NO ❑ ARHI Sheet Attached: YES ❑ NO ❑ Contract Attached: YES ❑ UNIT BEING REPLACED DATA NEW UNIT _ g heel__, MANUFACTURER �,11p....--.--„ AHU or PKG. UNIT MODEL # gFh &M ? 1 I ; c -.NY _RA X/ __Oy c -s; COND.UNITMODEL# RiAjyglo ji®liegl KW HEAT NOM TONS IR)(CM-17G VC 103 4<' oS di f?S AHU CU PKG 1) M.C.A AHU CU PKG AHU CU PKG 2) M.O.P AHU CU PKG AHU CU PKG 3) VOLTS AHU CU PKG PKG UNIT / / PKG UNIT / / EER/SEER YES NO REPLACING DUCTS _ YES YES NO REPLACING THERMOSTAT YES NO YES NO NEW 4"CONCRETE SLAB YES NO YES NO NEW ROOF STAND YES NO YES NO NEW RETURN PLENUM BOX YES NO 1. Minimum Circuit Ampacity (Wire Size): 2. Maximum Overcurrent Protection (Fuse/Breaker Size): 3. Voltage of Circuit (208/240/480): 4. Size Disconnecting Means: ^� �y Contractor's Company Name: /41 l� DuCf /n� n� 7 LS Phone: State Certificate or egi ration No. n4(4)5755-0 Certificate of Competency No. 0 A C 0 57 5 t ) Signature (Qualifier's signature) (Revised02/24/2014) Date: g /1 ef / 7 Certificate of Product Ratings AHRI Certified Reference Number: 7600905 Date: 8/11/2017 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: RA1448AJ1 Indoor Unit Model Number: RH1P4821STAN Manufacturer: RHEEM SALES COMPANY, INC. Trade/Brand name: RHEEM; RUUD Region: All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015, are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016, central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. Series name: Manufacturer responsible for the rating of this system combination is RHEEM SALES COMPANY, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 45500 EER Rating (Cooling): 11.70 SEER Rating (Cooling): 14.00 IEER Rating (Cooling): Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all (lability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or In part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed at bottom right. ©2014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE pec mike lit:° b'ticr 131469285168907972