Loading...
EL-16-2321Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-267290 Permit Number: EL -8-16-2321 Scheduled Inspection Date: September 15, 2016 Permit Type: Electrical - Residential Inspection Type: Final Owner: LOURDES STEPHEN, MICHAEL Work Classification: Service Change DI IhLIAr1CQ Job Address:124 NE 96 Street Inspector: Devaney, Michael Miami Shores, FL 33138 - Project: <NONE> Contractor: LS CURTIS INC Phone Number Parcel Number 1132060132690 Phone: (305)892-6501 Building Department Comments INCREASE SERVICE TO 320 AMP AND ADD 125 AMP PANEL Infractio Passed Comments INSPECTOR COMMENTS False Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Inspector Comme //L - /5Y 5 September 14, 2016 For Inspections please call: (305)762-4949 Page 20 of 23 Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Parcel Number 21 Cha, APPROV Expiration: 02/26/2017 Applicant 124 NE 96 Street Miami Shores, FL 33138- 1132060132690 Block: Lot: MICHAEL PUCHADES LOURDES Owner Information Address Phone Cell MICHAEL PUCHADES LOURDES 124 NE 96 Street MIAMI SHORES FL 33138- 124 NE 96 Street MIAMI SHORES FL 33138- Contractor(s) LS CURTIS INC Phone (305)892-6501 CeII Phone Valuation: Total Sq Feet: $ 2,400.00 0 Type of Work: INCREASE SERVICE TO 320 AMP AND ADD Additional Info: INCREASE SERVICE TO 320 AMP AND ADD Classification: Residential Scanning: 3 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - Additions/Alterations Scanning Fee Technology Fee Amount $1.80 $3.38 $3.38 $0.60 $225.00 $9.00 $2.40 Total: $245.56 Pay Date Pay Type Invoice # EL -8-16-61027 08/30/2016 Credit Card 08/18/2016 Credit Card Amt Paid Amt Due $ 195.56 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Review Electrical In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermothorize the above-named contractor to do the work stated. C� r Authorized Signature: Owner / Applicant / Contractor / Agent Building Department Copy August 30, 2016 Date August 30, 2016 1 BUILDING PERMIT APPLICATION BUILDING M ELECTRIC Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑ ROOFING PLUMBING ❑ MECHANICAL PUBLIC WORKS JOB ADDRESS: 124 NE 96 Street AUG )8 2016 FBC 20t 4` Master Permit No. £L (6"l6`2320 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes Occupancy Type: Load: Construction Type: Flood Zone: BFE: OWNER: Name (Fee Simple Titleholder): / !G ��,/!Q¢�//ijj Address: / 2 C/ /V re ,f •M City: NO FFE: X Phone#: ye ) O% S -n1 Tenant/Lessee Name: //� // Email: M(I# e P lhApoein,-!! 4v„ • (n State:FI Zip: 2`1( ,t'l CONTRACTOR: Company Name: L S Curtis Address: 20341 NE 30 Ave 108 Phone#: Phone#: 305-933-0683 City: AventuraState: FI Qualifier Name: Lewis Curtis Zip: 33180 Phone#: 305-933-0683 State Certification or Registration #: EC0003175 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 2400.00 Square/Linear Footage of Work: Type of Work: ❑ Addition n Alteration ❑ New Repair/Replace Description of Work: Increase service to 320 Amp and add 125 amp panel ❑ Demolition Specify color of color thru tile: Submittal Fee $ ' yO Scanning Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Permit Fee $ AO CCF $ i ` ED CO/CC $ Radon Fee $ eJ DBPR $ a . 3 U Notary $ Training/Education Fee $ 0 Q. e.)0 Double Fee $ Bond $ TOTAL FEE NOW DUE $ 1 95. 5 t 1 Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. '/ Sign. •- �— ---"- — - _ _ Signature OWNER or AGENT The foregoing instrument was acknowledged before me this �q `C, day of . OUCJUS , 20 L(J , by 0 day of ( , 20 ' , by ICVA _ 1 f LuCi'IC, ` g , who is personally known to , who is rsanall I . • , to me or who has produced as me or who has produced as CONTRACTOR The foregoing instrument was acknowledged before me this identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: :(,)C c;(1;i.to 3 (uervu identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: CASSANDRA NEBBIA Nola!► Pvblic - State of Florida Ike N FF 979238 i Bonded through Wont Notary Assn *****************************__********************************,********************************************* APPROVED BY (Revised02/24/2014) fe /14*'6. Plans Examiner Zoning Structural Review Clerk Property Search Application - Miami -Dade County OFFICE OF THE PROPERTY Summary Report Property Information Folio: 11-3206-013-2690 Property Address: 124 NE 96 ST Miami Shores, FL 33138-2726 Owner MICHAEL PUCHADES LOURDES STEPHEN Mailing Address 124 NE 96 ST MIAMI SHORES, FL 33138 USA Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY : 1 UNIT Beds / Baths / Half 3/2 / 0 Floors 1 Living Units 1 Actual Area 3,920 Sq.Ft Living Area 3,920 Sq.Ft Adjusted Area 3,722 Sq.Ft Lot Size 14,300 Sq.Ft Year Built 1938 Assessment Information Year 2016 2015 2014 Land Value $357,269 $271,858 $271,858 Building Value $259,585 $259,638 $252,975 XF Value $24,146 $18,719 $18,843 Market Value $641,000 $550,215 $543,676 Assessed Value $471,248 $467,973 $464,259 Benefits Information Benefit Type 2016 2015 2014 Save Our Homes Assessment Cap Reduction $169,752 $82,242 $79,417 Homestead Exemption $25,000t $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 LOT 12& 13BLK20 LOT SIZE 100.000 X 143 OR 21131-3611 03 2003 1 COC 22869-1258 08 2004 4 Page 1 of 1 Generated On : 8/18/2016 Tax ; 'County Exemption ?'a' je Taxable Value. School ora , Exemption Value . Taxabie 'Value aril, Exemption Value Taxable Value Regionai Exemption Wue Taxable Value $50,000 '54'14,259 S4.39,259 w 417,'=7 $50,000 $414,259 $3.(X i $50,000 $421,24,8' Saes t.r.re:aVon Previous 'Sale 11/15/2011 5632,000 Price 06/06/2011 $100 A 08/01/2004 1 08/01/2004 OR Book - Page 27906- 3494 r..2ualif;cat "! dixaro :. on 27833- . C . tax or OCC : 0312 i consideration 22553- JSiCc 'iiClk div Lua _ � a Iesult $0 0435 ofexaniration r)t' 22669- Sales Which are ais . ,.. :;s a result 1258 of exa n natior of t $0 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on reco!a. The Property Appra and Miami -Dade County assumes no liability, see full disclaimer and User Agreement ait hitp://www.miamidade.gov/info/disciaimer.asp Version: http://www.miamidade.gov/propertysearch/ ser 18/2016 001467 Local Business Tax Receipt Miami—Dade County, State of Florida -THIS IS NOT A BILL - DO NOT PAY 5108006 BUSINESS NAME/LOCATION L S CURTIS INC 20341 NE 30 AVE 108 AVENTURA FL 33180 OWNER L S CURTIS INC Worker(s) 1 RECEIPT NO. RENEWAL 2427060 LBT EXPIRES SEPTEMBER 30, 2017 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 SEC. TYPE OF BUSINESS 196 ELECTRICAL CONTRACTOR E00003175 PAYMENT RECEIVED BY TAX COLLECTOR $45.00 07/12/2016 CRED1TCARD-16-039366 This Local Business Tax Receipt only confirms payment of the Local Business Tax. Tho Receipt is not a license, ponni6 or a certification of the holder's qualifications, to do business. Holder must comply with any govammental or nongovernmental regulatory lows and requirements which apply to the business The RECEIPT NO. above must be displayed on all commercial vehicles Mienti-Dada Code Sec 8a-276. For more inlormation. visit yyww.miamidade.gav/taxcellecter STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD (850) 487-1395 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 CURTIS, LEWIS STEVEN L.S. CURTIS INC 20341 NE 30TH AVE APT 108 AVENTURA FL 33180 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridaticense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Departments initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! RICK SCOTT, GOVERNOR STATE•OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION Ec0003175 ISSUED 06/23/2016 CERTIFIED ELECTRICAL CONTRACTOR CURTIS, LEWIS STEVEN ` L.S. CURTIS INC IS CERTIFIED under the provisions or Ch. 469 FS. Expiration date ; AUG 31, MS L16O5230301113 DETACH HERE KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD LICENSE NUMBER EC0003175 The ELECTRICAL CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 CURTIS, LEWIS STEVEN L.S. CURTIS INC 20341 NE 30TH AVE #108 AVENTURA FL 33180 ISSUED: 06/23/2016 DISPLAY AS REQUIRED BY LAW SEQ # L1606230001113 Ow 320 AMP 10 Meter Can 2.c0,nfl a -c-2- '2 124 NE 96 Miami Shores, FI Riser Diagram 3 7 2/0 CO 200 AMP Rated 200 AJelv 1 ZS'amp Panel 24 circuit «1399 5/8 X 8' Galvanized(Z) Cold Water Pipe ami Shcrss Vill?cie J".JECT i.® CCMPIJ, NCE WTfri All FEDERAL T_ AH-;,) C I)N i "f HUL S AND R -G SLA TY !S EL I6-232) .... • • • •• •••• • • •• • ••• •• • • • • • • • •. • . •••• • • • • • • •••• • • • • •••• •• • • •• ••• • • • • • • • • •••• • • • • • •. • L S Curtis 20341 NE 30 Ave #108 Aventura, FL 33180 EO0003175 LOAD CALCULATION & RISER DIAGRAM (320 AMP SERVICE) L S Curtis Electrical Contractor 305-933-0683 786-486-1961 For the Property: 124 NE 96 Street Miami Shores, FL Load calculation for panel 'A" 4124 sq. ft. at 3 VA 12372 2 s/a circuits • 3000 Laundry (1) 1500 Clothes washer 1,500 Refrigerator 1200 Cook top 5,000 Oven 5000 Water Heater 4500 Dishwasher 1,200 Dryer 5,000 Microwave 1300 Range hood 200 Pool equipment 1500 Total 43272 1St 10,000 @ 100% Remainder @ .40 x 33272.00 Heat Strip 20 kw @ 65% 36309/240 = 189 amps Panel A Panel B (please see sheet 2) Total 200 AMP SERVICE is ADEQUATE L� uvis Stevefr'Curtis EC # 0003175 151 27 178 10,000 VA 13309 VA 13000 VA Total 36309 •• •.• • • • . . •• • l \. •• • • ▪ • • •• ••• •• • • • • • ••• • ••• • •• • • •• • • • • • • • • •• • • • • • • • •• • • •• • • •• • • • • ••• • • • • • • • • • • • • ••• • • • • • •• • • • • • CASSANDRA NEBBI Notary Public - State of Floc •s Commission i FF 97923e My Comm. Expires Jul 25, 2c Bonded tinou9b National Notary A • • • • • • • • • • •• •• • • • LOAD CALCULATION & RISER DIAGRAM (320) AMP SERVICE) Pane B L S Curtis Electrical Contractor 305-933-0683 786-486-1961 For the Property: 124 NE 96 Street Miami Shores, FL Load calculation for panel `B" Exterior Illumination .2000 LED Lighting circuits (4) 500 (4) GFI exterior receptacles 4000 Total 6500 1st 10,000 @ 100% Remainder @ .40 x 00 6500/240 = 27 amps Lewis Steven Curtis EC # 0003175 6500 VA 0000 VA Total 6500 VA •• ••• • • • • • •• • •• • • • • • • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • • • • • • • •"• • • •• • • • • • • • • • •• • • •• • • • • •• • • • • • ••• • • • • ••• • • • • • • • • • • • • • ••• • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • ,• 1 h 18, CASSANDRA NEBBIA IFYAl fir - —= t public- State of Florida Com r ; . mission 9 FF 979238 ?���••: My Comm. Expires Jul 25, 2020 ,,,°; ,°,t,,`' Bonded through National Notary Assn. 11.1"1.1.1110 For The Property Know as: 124 NE 96 Street L S Curtis Electrical Contractor 305-933-0683 EC# 0003175 Panel "A" Description CKT# Poles Trip Description spare CKT# 21 Poles 20 Trip 1 Oven 1 30 2 Oven 2 30 2 spare 22 20 1 Living rm lights 3 15 1 Dryer 23 30 2 Outside lights 4 15 1 Dryer 24 30 2 Pool light 5 15 1 spare 25 20 1 lights 6 20 1 spare 26 20 1 lights 7 20 1 spare 27 20 1 Cook Top 8 30 2 spare 28 20 1 Cook Top 9 30 2 Kitchen S/A 29 20 1 spare 10 20 1 Kitchen S/A 30 20 1 spare 11 20 1 Dish washer 31 20 1 spare 12 20 1 Kitchen GFI 32 20 1 Refrig 13 20 1 Bathrooms & Receptacles 33 15 1 Dinning room lite 14 15 1 bedroom Lights 34 15 1 Kitchen S/A 15 20 1 spare 35 100 2 Washing machine 16 20 1 spare 36 100 2 Kitchen Light 17 20 1 Bedroom Lights 37 15 1 microwave 18 20 1 Bathroom Lights 38 15 1 General lighting 19 15 1 Family Room Lights, Receptacles 39 15 1 Living room lites 20 15 1 Kitchen & Breakfast lite 40 15 1 Range hood 21 20 1 Spare 42 20 1 L S Curtis Notary •• ••• • • • • • •• • • • • • • • • • •• •• • •• • • • •• • ••• • ••• • 1 `�� un ,��, CASSANIZRA ItEIefA • • • • • Notary Pubfe - Stab of Florida • Commission • FF 979238 ♦ •,,x,1111,,' My Comm. Expires Jul 25, 2Q20, ••. Bonded throes N& al tSWary keens ► • • • •• •• • • • ••• • • • ••• • • • • • • •••• • • • • • • • • • • • • • • • 1 • • •• •• • • L S Curtis Electrical Contractor 305-933-0683 EC# 0003175 For The Property Know as: 124 NE 96 Street Description CKT# Trip Poles LED landscape 1 20 1 LED Landscape 2 20 1 GFI Rec 3 20 1 GFI Rec 4 20 1 Spare 5 15 1 Spare 6 20 1 Spare 7 20 2 Space 8 20 1 Space 9 20 1 space 10 20 1 space 11 20 1 space 12 20 1 L S Curtis 111E0 - Notary I r0"!"',,,,„. CASSANDRA NEBBIA 1,1 Notary Public - State o1 Florida • a Commission • FF 979238 My Comm. Expires Jul 25, 2020 Bonded through National Notary Assn Panel "B” 125 AMP Rated Description CKT# Trip Poles GFI Rec 13 20 1 GFI Rec 14 20 1 Spare 15 15 1 Spare 16 15 1 Spare 17 20 1 Spare 18 20 1 Spare 19 20 1 Space 20 20 1 space 21 20 1 space 22 20 1 space Z3 20 1 space 24 20 1 •• ••• • • • • • •• • • • • • • • • • •• ••• •• • • • •• • ••• • ••• • • • • • 1 • • • • • • • • • • • • • • • •• • • • • • • • • • •• • • •• • • • • • •• • • •• • ••• • • • • 111 • • • • • • • • • • • • • ••• • • • • • • • • • • ••'• • • •• •• • • • •• •• ••• • • • ••• • •