RF-16-11421
ENGINEQIING
4225 SW 71 Ave Miami. FI 33155
Tel: 786-398-9179 Fax: 786-800-2627
al roofinspection angmail.com
LAB CERTIFICATION #16-0510.15
SITE SPECIFIC INFORMATION
UPLIFT TEST - TAS #106
05/15/2017
Roofing Contractor ADONAI ROOFING INC.
Job Address 1208 NE 95 ST MIAMI SHORES 33138
Owner's Name
Type of Tile MONIER BANGAR DOUBLE ROLL
Approximate Roof Height 12' feet
Approximate Square Footage of Roof 14
Date Tested 05/15/2017
Contact Name MANUEL JARA
Roof Pitch 3/12
ft2
Number of Tests 22
Permit # RF4161142
Date Installed
Type of Access to Roof LADDER
Required Testing Force 35 Lbs
Testing Equipment F.G.E.100
Phone # 786-299-2807
LOCATION
# OF TEST
PASS
# OF TEST
FAIL
Corner
4
Tests
4
Pass
Test
Fail
Perimeter
4
Tests
4
Pass
Test
Fail
Field
14
Tests
14
Pass
Test
Fail
Ridge
0
Tests
0
Pass
Test
Fail
TOTAL
22
Tests
22
Pass
o
Test
0
Fail
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE
REQUIREMENTS OF DADE COUNTRY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS. THIS REPORT IT IS NOT VALID FOR INSURANCE CLAIMS.
YENAN T. LEYVA
PE. 67416
e
Job Address 1208 NE 95 ST MIAMI SHORES 33138
Project Address
Miami Shores Village
10050 N.E. 2nd Avenue NE
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Parcel Number
PROVE
Expiration: 10/3102016
Applicant
Owner Information
Address
Phone
CeII
PEDRO DE MELLO
1208 NE 95 Street
MIAMI SHORES FL 33138-
(305)753-5504
1208 NE 95 Street
MIAMI SHORES FL 33138-
Contractor(s)
ADONAI ROOFING INC
Phone CeII Phone
(305)441-1365
Valuation:
Total Sq Feet:
$ 2,000.00
144
Type of Work: Re Roof
Additional Info:
Classification: Residential
Scanning: 4
Fees Due
CCF
DBPR Fee
DCA Fee
Education Surcharge
Permit Fee - New Roof
Scanning Fee
Technology Fee
Total:
Amount
$1.20
$3.75
$3.75
$0.40
$250.00
$12.00
$1.60
$272.70
Pay Date Pay Type
Invoice # RF -4-16-59570
05/04/2016 Credit Card
04/28/2016 Credit Card
Amt Paid Amt Due
$ 222.70 $ 50.00
$ 50.00 $ 0.00
Available Inspections:
Inspection Type:
Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Cap Sheet
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Futhe is • - .. • - above-named contractor to do the work stated.
ignature: Owner / Applicant / Contractor / Agent
Building Department Copy
May 04, 2016
Date
May 04, 2016
1
BUILDING
PERMIT APPLICATION
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
FBC 20 N
Master Permit No. Re -15
Sub Permit No. RP Ro — 1 1 y 2-
❑ BUILDING ELECTRIC ► 4 ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION D SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: /208 NE cift
City: Miami Shores
County:
Miami Dade Zip:
Folio/Parcel#: 1/3204,01'1Y/00 Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type:
Flood Zone:
BFE: FFE:
OWNER: Name (Fee Simple Titleholder): Pdb Alen rif2c arr' de MG%� Phone#: 305- 7s3 SSo Y
Address:
i2.0e AIc ,S /
City: MI F I7)i,J/)O!'eS State: Ft-
Tenant/Lessee Name: Phone#:
cAtu
Email:
Phone#: 7 B (o 390 0 /39
zip: 33/.38
CONTRACTOR: Company Natne: ! 'CIO 44 / /20 a 'Ai, ! h c_
Address: .230`7 So041.1 t7t»j1 % 4d s0I
City: pa a State: (cc Zip: 33/ 4/C
Qualifier Name: (/tri. T Gat 4t ' , . Phone#:
State Certification or Registration #: OCC-' 13ZS8qCertificate of Competency #:
DESIGNER: Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit: $ Zi CC0 Square/Linear Footage of Work: Ir 4
y
Type of Work: D Addition ❑ Alteration
Description of Work: ZQ .
)1/41e1200F`.1, L�
New
❑ Repair/Replace ❑ Demolition
Specify color of color thru tile:
Submittal Fee $ - Permit Fee $ (3 - 03 CCF $ ) CO/CC $ pS
Scanning Fee $ " 00 Radon Fee $ 3 7T-7 DBPR $ �' �S Notary $
Technology Fee $ \ . ' 0 Training/Education Fee $ c `fid Double Fee $ °
Structural Reviews $ cp Bond $ V ---Q i S / e q
TOTAL FEE NOW DUE $ c aD ,--i0
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning. • .
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR. NOTICE OF .COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith;thata copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a cerfiied copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
`'
Signatp �/ Signature.
OWNER or AGENT
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
V day of (t0 , 20 t V , by eN day of / , 20 / G , by
AciW ike..U. , who is personally known to C kJ— °kre.-i , who is Personally known to
•
me or who has produced as me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
CIA O
###############
APPROVED BY
(Revised02/24/2014)
#
identification and who did take an oath.
NOTARY PUBLIC:
Sign: �'�--
Print 1&.vi. 9.44±s5--"*- •
Seal:
ve.°-`°vim. CLARA E RODRIGUEZ
,ft "= MY COMMISSION #FF138588
........ EXPIRES July 5, 2018
(4W 3 i=4* Flplivai ** ###
Plans Examiner Zoning
Structural Review Clerk
003019
Local Business Tax Receipt
Miami—Dade County, State of Florida
-THIS IS NOTA BILL - DO NOT PAY
5222591
BUSINESS NAME/LOCATION
ADONAI ROOFING INC
2307 5 DOUGLAS RD STE 501
MIAMI FL 33145
OWNER
ADONAI ROOFING INC
Worker(s)
RECEIPT NO.
RENEWAL
6458195
LBT
EXPIRES
SEPTEMBER 30, 2016
Must be displayed at place of business
Pursuant to County Code
Chapter 8A - Art. 9 & 10
SEC. TYPE OF BUSINESS PAYMENT RECEIVED
196 SPECIALTY BUILDING CONTRACTOR BY TAX COLLECTOR
CCC1325896
$75.00 09/28/2015
CREDITCARD-1 5-050582
Thie Local Business Tax Receipt only confirms payment of the Local Business Ter:. The Receipt is not a license,
permit, or a certification of the holder's qualifications, to do bestows. Holder must comply with any governmental
or nongovernmental regulatory laws end requirements which apply to the business.
The RECEIPT NO. above must be displayed an all commercial vehicles - Miami -Bede Code See 8a -V13.
For more itdormadon, visit warw.miamldade.eovhturcofactot
• CERTIFICATE OF LIABILITY INSURANCE
5/4 2016
Producer: Plymouth Insurance Agency
2739 U.S. Highway 19 N.
Holiday, FL 34691
(727) 938-5562
This Certificate is issued as a matter of information only and confers no
rights upon the Certificate Holder. This Certificate does not amend, extend
or alter the coverage afforded by the policies below.
Insurers Affording Coverage
NAIC #
Insured: South East Personnel Leasing, Inc. & Subsidiaries
2739 U.S. Highway 19 N.
Holiday, FL 34691
Insurer A: Lion Insurance Company
11075
Insurers:
Insurers:
Insurer D:
Insurer E:
Coverages
The policies of insurance listed below have been issued to the Insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document
with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate
limits shown may have been reduced by paid claims.
INSR
LTR
ADDL
INSRD
Type of Insurance
Policy Number
Policy Effective
Date
(MM/DD/YY)
Policy Expiration
Date
(MM/DD/YY)
Limits
GENERAL
LIABILITY
Commercial General Liability
Each Occurrence
$
Damage to rented premises (EA
occurrence)
$
Claims Made Occur
Med Exp
$
Personal Adv Injury
$
General aggregate limit applies per:
D Policy ❑ Project ❑ LOC
General Aggregate
$
Products - Comp/Op Agg
$
AUTOMOBILE
LIABILITY
Any Auto
All Owned Autos
Scheduled Autos
Hired Autos
Non-Owned Autos
Combined Single Limit
(EA Accident)
$
Bodily Injury
(Per Person)
$
Bodily Injury
(Per Accident)
$
Property Damage
(Per Accident)
$
EXCESS/UMBRELLA LIABILITY
ROccur ❑ Claims Made
Deductible
Each Occurrence
Aggregate
A
Workers Compensation and
Employers' Liability
Any proprietor/partner/executive officer/member
excluded? NO
If Yes, describe under special provisions below.
WC 71949
01/01/2016
01/01/2017
X
I WC Statu- I
tory Limits
1OTH-
ER
E.L. Each Accident
$1,000,000
E.L. Disease - Ea Employee
$1,000,000
E.L. Disease - Policy Limits
$1,000,000
Other
Lion Insurance Company is A.M. Best Company rated A- (Excellent). AMB # 12616
Descriptions of Operations/LocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 84-65-672
Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company":
Adonal Roofing, Inc.
Coverage only applies to Injuries Incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL.
Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity.
A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562.
Project Name:
ISSUE 05-04-16 (TD)
Begin Date 12/7/2015
CERTIFICATE HOLDER CANCELLATION
VILLAGE OF MIAMI SHORES
BUILDING DEPARTMENT
10050 NE 2ND AVENUE
MIAMI SHORES, FL 33138
Should any of the above described policies be cancelled before the expiration date thereof, the issuing
insurer will endeavor to mall 30 days written notice to the certificate holder named to the left, but failure to
do so shall impose no obligation or liability of any kind upon the insurer, Its agents or representatives.
R*
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Seed n A Montreal Onf # atlen1
p ®. 1)---C a3- M 'S— Rump, No.
Job
ROOF CATEGO x �f
Mechanically Fastened Tile r nor/ t z&solve ± rib
'Retei tl anei/$hingles ® Wood Shin >lealShaaes
11;
Asphalt&
Shingles
frilew Rooff
Lei
Prescriptive BUR -RAS 150
RO F TYPE
Are there
Gas Vent Stacks?
Yes Nozr•'
Type: Nature:a LPGX
Recovering (l Repair li Maintenance
. RIOfF SYSTEM !INFORMis g
oogArea (SF) Steep Sloes! Roof
L t -t4 sq
(SF) Total (SF)
1,464 5,9'4 -
Section (Roof Plan)
••••
Sketch Roof Plan: iiiussrata all levels �.; melons, roof drains, e�ul
•
acuppero end ov +i.,� d- no. Maks :t d nsloras of sections as i�1
identify dimensions of elevated pressure zones and location of para T« • •
•••
••.• •
•
•••• •
t •
'e'/J] H ALL FEDERAL
ROOF ASSEMBUES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section D (Steep Sloped Roof System)
Roof System Manufacturer: 5 /4-.e ark \ Le- 4' ar_
Notice of Acceptance Number: 9 1 p 2,_ 09
Minimum Design Wind Pressures, If Applicable
licable (From RAS 127 or Calculations): aro
PL P1: P1: — 100
\DeckTYPe: I-- SIt TIN 0004 )(S'
Roof Slope:
: 12
Ridge Ventilation?
1.4 to -
Type Underlayment I s¶e 1 - 1
Insulation:
tar
Fire Barrier: L
Mean Roof Height: \'4' f+ -
Fastener Type & Spacing: 0, ( P
Adhesive Type:
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
`?6L.( tris �}���;rt� i t!s:. I
•. • p'
Roof Covering: •bvt • • - • 1
•• •• .• • 1
Type Cap Sheet:
...
Se. �' 1�.8. dt _ •
. .
.• •
Type & Size Drip
Edge:
89� %6A I Wt -4(
1
• 1'
. •
• . .
.• •
•• •
FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
INTERNATIONAL CODE COUNCIL'
.•
•
.
.
•
•
•
.
•
1
1
1
11
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014)
High -Velocity Hurricane Zone uniform Permit Application Form.
1
Section E (Tile Calculations)
1 For Moment based the systems, choose either Method 1 or 2. Compare the values for M with the values from M,. If the M, values
are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable.
1
1
1
1
1
Method 1 "Moment Based Tile Calculations Per RAS 127"
0= M„ Product Approval M, Z6 . tx
0= M,) Z fQ Product Approval IA GI. 1
0= Ma ( Product Approval M, Z-.1
(Pfr34.I x O-67=JJ. 30 ) - Mg
(P2-. 68-1 xx0-;:gy /q.69) - Mg
(P3:)OO. x .Q =Z l.l) ) - Mg:
Method 2 "Simplified Tile Calculations Per Table Below"
1 Required Moment of Resistance (Mr) From Table Below
1 Product Approval M,2. _ 1
0
1
1
1
1
1
1
1
1
1
1
1
*Must be u
Appeals.
Mr required Moment Resistance*
• . • •
: •
Mean Roof Height
Roof Slope
15'
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
.••.
Cunt lB oard of REI9S and
•• • ••••
•
F'U9IG$S tire greStbf Phan or
1 Method 3 "Uplift Based Tile Calculations Per RAS 127" •• •
1
(P1: x L = x w: )_W: xcos 0=Fr, Product Approval F' •••••••
(P2:xL=xw:= ) - W: xcos6 = F
_ Product Approval F' .. • • • •
1 (P3: xL_=xw:= )-W xcos0 =
Fa Product Approval F'
0
111
1
1
1
1
1
1
1
1
1
1
1
• • •
•• •
• • •
• ••
•• •
• • •
•. •
•
Where to Obtain Information
• . • •
: •
Description
Symbol
Where t3 find' .- 7, - •
Design Pressure
P1 or P2 or P3
RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
a.
Product Approval
Restoring Moment due to Gravity
M8
Product Approval
Attachment Resistance
M,
Product Approval
Required Moment Resistance
MB
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
15.40
INTERNATIONAL CODE COUNCIL
•
•
•
•
FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014)
Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 201510:32:12 AM pursuant to License
Agreement. No further reproductions authorized.
MIAM WADE '
ail
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
Forterra Roof Tile, Inc.
1340 SW 34th Ave
Deerfield Beach, FL 33442
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.2ov/pera
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Hanson Hacienda Double Roll Roof Tile
. • ••
•
. .•••
•• • ••••
•
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, Al/ :Me and fdlydving
•
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
• • •
••••• •• •
•
•
RENEWAL of this NOA shall be considered after a renewal application has been filed and thWe'lfas been'ho Mange
in the applicable building code negatively affecting the performance of this product. • . • •' •' •
•• ••• •• .
TERMINATION of this NOA will occur after the expiration date or if there has been a revi a$ pt' change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement'of anprod 1st,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to with an%section
of this NOA shall be cause for termination and removal of NOA. • • •
••• •
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 12-0917.07 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI DADE COUNTY
APPROVED
NOA No.: 15-1102.04
Expiration Date: 12/16/17
Approval Date: 12/10/15
Page 1 of 6
•
•
•
•
•
•
ROOFING ASSEMBLY APPROVAL
Category: Roofmg
Sub Category: Roofmg Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Hanson Hacienda Roof Tile, as manufactured by Forterra Roof Tile in
Deerfield Beach, Florida and as described in Section 2 of this Notice of Acceptance. For the locations where
the pressure requirements, do not exceed the values listed in section 4 herein. The attachment calculations shall
be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured byTest Product
Applicant Dimensions Specifications Description
Hanson "Hacienda"
Trim Pieces
••.•
• •
Length: 17/" Low profile, interlocking, extruded concrete roof
Width: 13" TAS 112 tile equipped with two nail hole and double roll
'/2' thick ribs. For direct deck or battened nail -on, mortar or
adhesive set applications.
TAS 112 Accessory trim, concrete roof pieces for use at hips,
rakes, ridges and valley terminations.
Manufactured for each tile profile.
1= varies
w = varies
varying thickness
2.1 MVPANUFACTURft' G LOCATION
•••• • ••
2.1.1.:Deerfie1dJ k, FL
• ••
• • 2.2 1+ V1D NCE$IIB'NjITTED:
•• • ••••
• • . .Test Agency...
Redland Technologies • • •
• •
• • •
• • .•..
• .•
• ••
. . •
• •
•. •
••
..
Professional Service Industries,
Inc.
The Center for Applied
Engineering, Inc.
MIAMI•DADE COUNTY
APPROVED
Test Identifier
7161-03
7161-03
7161-03
P0402
P0631-01
Letter Dated Aug. 1, 1994
224-47099
94-060B
94-084
25-7094-1
25-7094-7
25-7094-4
Project No. 307025
Test #MDC -76
Test Name/Report
PA 102
PA 102(A)
PA 108
Withdrawal Resistance Testing of
screw vs. smooth shank nails
PA 108
PA 108
PA 112
PA 101
PA 101
PA 102
PA 102
PA 102
PA 100
Date
Dec. 1991
Dec. 1991
Dec. 1991
Sept. 1993
July 1994
Aug. 1994
Sept. 1994
March, 1994
May 1994
Oct. 1994
Oct. 1994
Oct. 1994
Oct. 1994
NOA No.: 15-1102.04
Expiration Date: 12/16/17
Approval Date: 12/10/15
Page 2 of 6
N.
2.2 EVIDENCE SUBNIITTED:
Test Agency
Celotex Corporation Testing
Services
Walker Engineering, Inc.
IBA Consultants, Inc.
American Test Lab of South
Florida
Test Identifier
25-7183-1
25-7183-2
25-7214-2
25-7214-6
528454-2-1
520109-2
Calculations
2381-249
RT1024.01- 11
Test Name/Report
PA 102
PA 102
PA 102
PA 102
PA 101
Aerodynamic Multiplier
TAS 112
TAS 112
Date
Feb. 1995
Feb. 1995
March, 1995
March, 1995
Sep. 1998
Dec. 1998
March 1999
09/20/07
10/28/11
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofmg Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope uni 'srstated
•otherwise by the underlayment material manufacturers published literature. • • •
..• . ....
3.6 This acceptance is for wood deck applications. Minimum deck requirements shali ilia compliance with
applicable building code. •
MIAMI•DADE COUNTY
APPROVED
. .
....
. . .
• •
• • .
.. .
.
• . •
• •.
.. •
• •
• •
..•
•
•
• .
.
NOA No.: 15-1102.04
Expiration Date: 12/16/17
Approval Date: 12/10/15
Page 3 of 6
4. INSTALLATION
4.1 Hanson `Hacienda' Roof Tile and its components shall be installed in strict compliance with Roofmg
Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight -W (Ibf)
Length -I (ft)
Width -w (ft)
Hanson Hacienda Tile
10.0
1.4375
1.08
Table 3 Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
Table 2: Aerodynamic Multipliers - A. (ft3)
4": 12"
Tile
6": 12"
A. (ft3)
X (ft3)
Battens
Profile
Battens
Batten Application
Direct Deck Application
Hanson Hacienda Tile
Battens
Direct
Deck
0.267
0.289
Table 3 Restoring Moments due to Gravity - Mg (ft-Ibf)
Tile
Profile
3": 12"
4": 12"
6": 12"
6": 12"
7": 12" or
greater
Hanson
Hacienda Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
"" Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf)
•
• • • For Nail -On Systems
.ti�e• •
Profile
• ••
•. • X stener Type
••••
Direct Deck
(Min 16/32" plywood)
Direct Deck
(Min. 19/32" plywood)
Battens
Hansgrl • ;
Haciecda•Tile
'•�•••
•
• •
•
•' •• •' .
• •'
2-6141d Ring Shank Nails
27.8
37.4
28.8
1.1AdSmooth or Screw
�••�•Shank Nail
8.8
11.8
4.1
tfmooth or Screw
• Shank Nails
16.4
21.9
7.1
j #8 Screw
25.8
25.8
22.9
• "2 #8 Screw
47.1
47.1
49.1
1-10d Smooth or Screw
Shank Nail (Field Clip)
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail (Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails (Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails (Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails' 43.0 67.5
50.9
1 Installation with a 4" tile headlap and fasteners are located a min. of 2W from head of tile.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 15-1102.04
Expiration Date: 12/16/17
Approval Date: 12/10/15
Page 4 of 6
Table 6: Attachment Resistance Expressed as a Moment Mt (ft-ibf)
for Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Hanson Hacienda Tile
Adhesive'
26.13
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty
3MT1" 2 -Component Foam Roof Tile Adhesive AH -160. Average
11.4 grams.
weight per patty 8 grams.
Table 7: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf)
for Single Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Hanson Hacienda Tile
3MTM 2 -Component Foam Roof Tile Adhesive AH -160
86.614
3MTM 2 -Component Foam Roof Tile Adhesive AH -160
45.55
4 Large paddy placement of 54 grams
5 Medium paddy placement of 24 grams
Table 8: Attachment Resistance Expressed as a Moment - Mr(ft-Ibf)
for Mortar or Adhesive Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Hanson Hacienda Tile
Mortar Set
• 20.6 e....•
5. LABELING
• .•
•• •
••••
• •
••••
All tiles shall bear the imprint or identifiable marking of the manufacturer's ndhie M' logo, or fallowing • •
statement: "Miami -Dade County Product Control Approved". •••••• •• •
•• • •
•••• •• ••
• •
•• ••
Hansom.._�..:
HANSON HACIENDA ROOF TILE
TILE IDENTIFICATION MARK (LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
MANMADE COUNTY
APPROVED
NOA No.: 15-1102.04
Expiration Date: 12/16/17
Approval Date: 12/10/15
Page 5 of 6
• •
•
•
•
• •
• •
FASTENER HOLES
PROFILE DRAWINGS
OVERLOCK
...
. .
•...
UNDERLOCK 13
.
....
• .
. ..
• • •
•
• • •
• ..
•
• • • .• ••••
.
•• • •
..• ••••
• •
•
•
•
• ..
•
• ..
•
• •
.
•
• • •
•. •
• • •••• • ..
.. •
MIAMI•DADE COUNTY
APPROVED
HANSON HACIENDA CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 15-1102.04
Expiration Date: 12/16/17
Approval Date: 12/10/15
Page 6 of 6
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.Eov/economy
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
. • ••
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, cit j state add following • •
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.• • •
•
RENEWAL of this NOA shall be considered after a renewal application has been filed and.tbese has been iao change• • •
• • • •
in the applicable building code negatively affecting the performance of this product. •••• • • •
•• •
• • • • •
TERMINATION of this NOA will occur after the expiration date or if there has been a reVisibh or chat ge in the
•
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product • •
for sales, advertising or any other purposes shall automatically terminate this NOA. Failurato comply ldth'811y section •
of this NOA shall be cause for termination and removal of NOA. • • • •• • • •• • •
.•
•• •
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #12-0713.02 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 1 of 9
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Polystick MTS
Manufacturing Location
#2
Polystick MTS Plus
Manufacturing Location
#2
Polystick IR -Xe
Manufacturing Location
#1 & #2
Polystick TU Plus
(Surface Printing)
Manufacturing Location
#1 & #2
Polystick TU P
Manufacturing Location
#2
Polystick Tile Pro
Manufacturing Location
#2
Polystick Dual Pro
Manufacturing Location
#2
Dimensions
Roll:
65'8" x 3'33/8"
60 mils thick
Roll:
65'8" x 3'3-3/8"
60 mils thick
Roll:
65' x 3'3-3/8"
Or 65' x 3'
60 mils thick
Roll:
65' x 3'33/8"
80 mils thick
Roll:
32'10" x 3'3-3/8"
130 mils thick
Roll:
61' x 3'33/8"
60 mils thick
Roll:
61' x 3'33/8"
60 mils thick
Test
Specification
TAS 103
TAS 103
Product
Description
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic
film on the upper surface for use as an
underlayment for metal roofing, roof tile, slate
tiles and shingle underlayment.
A homogeneous, rubberized asphalt waterproofing
membrane, glass fiber reinforced with polyolefinic
film on the upper surface for use as an
underlayment for metal roofing, roof tile, slate
tiles and shingle underlayment.
ASTM D 1970 A fine granular/sand top surface self -adhering,
APP polymer modified, fiberglass reinforced,
bituminous sheet material for use as an
underlayment in sloped roof assemblies.
Designed as an ice & rain shield. ••••••
TAS 103 and ASTM A rubberized asphalt s81T adhering, M-
D 1970 fiber/polyester reinfo;i; waterproong• •
membrane. Designed aim, metal r44fing and r¢ef • •
file underlayment. ' • • • • • • •..'
••
.
•. •
• . • • •
•
TAS 103 and ASTM A rubberized asphalt ygi• tproofing r embrane, • •
D 1970 glass-fiber/polyester b"einioi ced, with a granulas..:.
surface designed for Ise gs p tile roof.
underlayment. • • • .•' •
TAS 103 and ASTM A rubberized asphalt self -adhering, glass -
D 1970 fiber/polyester reinforced waterproofing
membrane. Designed as a metal roofing and roof
tile underlayment.
•
.
TAS 103 and ASTM A rubberized asphalt self -adhering, glass -
D 1970 fiber/polyester reinforced waterproofing
membrane. Designed as a metal roofing and roof
tile underlayment.
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 2 of 9
PRODUCTS DESCRIPTION:
Product
Polystick TU Max
Manufacturing Location
#2
Elastoflex S6 G
Dimensions
Roll:
65'8" x 3'3-3/8"
60 mils thick
Test Product
Specification Description
TAS 103 and ASTM A rubberized asphalt self -adhering, polyester
D 1970 reinforced waterproofing membrane. Designed as
a a roof tile underlayment.
Roll: TAS 103 and ASTM Polyester reinforced, SBS modified bitumen
32' 10" x 3' 3-3/8" D6164 membrane with a burn off polyethylene or sanded
back face and a granule top surface. For use in
roof tile underlayment systems.
MANUFACTURING PLANTS:
1.Hazelton, PA
2. W inter Haven, FL
EVIDENCE SUBMITTED:
Test Agency
Trinity I ERD
PRI Asphalt Technologies
Momentum Technologies, Inc.
Test Identifier
P10870.09.08 -R1
P10870.04.09
P33360.06.10
P33370.03.11
P33370.04.11
P36900.09.11
P37300.10.11
P40390. 08.12-1
P40390.08.12-2
P40390.10.12
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PUSA-035-02-01
PUSA-055-02-02
PUSA-089-02-01
JX20H7A
RX14E8A
DX23D8B
DX23D8A
Test Name/Report
TAS 103
TAS 103/ASTM D4798 & G155
ASTM D1970
TAS 103
ASTM D 1623
TAS 103/ASTM D4798 & G155
TAS 110/ASTM D4798 & P 1 NVQ
TAS 103 & TAS 110 •• •
ASTM D 1623 •
ASTM D 1970
ASTM D6164
TAS 103, TAS 110 & AS•
D 1623
••••
. •
•• ••
ASTM D1623 • . •
TAS 103 & TAS 110 •
ASTM D 1970 & TAS •1.10
•
TAS 103
TAS 103
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
TAS 103/ASTM D4798 & G155
Date
12/04/08
04/13/09
07/01/10
03/02/11
04/26/11
•i09101/11
• • 4Ew19/11
:7871®6/12
• il8/07/12
•• 1003/12;
11.7262/13
..05/12/14
•
•
•
• •
•
• •
••• •
•
m/03/14 ••
•• •14/07/14 • •
.•1.0/17/14•
• • •
•
• • 09/29/06
12/10/07
07/06/09
04/01/08
11/09/09
02/18/10
02/18/10
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 3 of 9
•
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1) Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2) Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3) Base sheet mechanically fastened deck, subsequent cap membrane self+�he�ed.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. • • : •
•
••:•
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at aplum 4" head lap. 4for .
base sheet only) • • • • • • • • •
• •• • •
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal lis: cl mininwm:6" vert]
(Optional) laps.•••••` ••••••
•
Membrane: Polystick TU Plus, self -adhered. . .. • '•
• • • •
Surfacing: See General Limitations Below. ••
• • •
•• • •••• • •
• • •
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 4 of 9
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and
sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-%2" and end laps
shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of
the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building
code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention
to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, Polystick MTS Plus, Polystick TU Plus, Polystick Tile Pro and Polystick Dual Pro may be used
in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate
roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR -Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be
used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
• •
• .•
•• •
• •
••••
••••
•
••••
1
•
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface..Tke.deck shall be free of .
irregularities.•""• ••
•• •. •
•
5. Polyglass Polystick membranes and underlayments shall not be adhered directly ove,r.a pie -existing rpof • ••
• • • • •
membrane as a recover system. • • • • • • •
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for for ;ertrign the amok nt of days': •
listed in the table below after application. Polyglass reserves the right to revise or alter productrkpti5we tires; .
• • •
not to exceed the preceeding maximum time limitations. • • • • • • •
• • •
Exposure Limitations (days)
• • •
MTS
IR -Xe
Elastoflex
S6 G
TU Plus
TU P
Tile Pro
Dual Pro
TU Max
MTS Plus
Winter Haven,
FL.
180
90
180
180
180
180
180
90
180
Hazelton, PA.
N/A
90
N/A
180
N/A
N/A
N/A
N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 5 of 9
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU Plus, Polystick Tile Pro, Polystick TU Max or Elastoflex S6
G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is
limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to
mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically
fastened roof tile applications with the exception of mortar set tile applications.
9a. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Elastoflex S6 G
Polystick TU Plus,
TU P, Tile Pro,
Dual Pro
Polystick TU
Max
Polystick MTS
Plus'
Flat Tile
Prohibited
without battens
4:12
No limitation
No limitation
5:12
Profiled Tile
Prohibited
without battens
4:12
No limitation
No limitation
4:12
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are
required for both loading and installation of tiles at all times.
'The following limitations shall be apply when using Polystick MTS Plus:
• Slopes up to those shown in the table above will require stagging of tiles — two tiles laid perpendicular to
slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles. (See Figure 1
below)
• Battens shall be used for stagging of lugged tiles above 4:12
• Battens shall be used for stagging of flat tiles above 5:12
J/ Slope
Figure 1: Stagging Method
••••
• •
• • ••••
•
• •
•• • ••••
•
••••
•
•
•
••
• •
•••• •• • • •
• • • • ••
•
•••• • •• P
• •
•• ••
• • •
•• •
• • •
•••
•
•
• •
•
• • •
•• • •••• • •
9b. There shall be no roof slope limitation for the Polystick MTS Plus / Polystick TU Plus two-ply underlayment
system when a applied using the stagging method outlined above.
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 6 of 9
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
Roof Deck prepared wilt
POLSSIICKlU Plus
•
Roofing Tiles
(6 Max Per Stack)
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick MTS, Polystick MTS Plus, Polystick IR -Xe, Polystick TU Plus,
Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G may be used with
any approved roof covering Notice of Acceptance listing Polystick MTS, Polystick MTS Plus, Polystick IR -Xe,
Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G
as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, Polystick MTS Plus,
Polystick IR -Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro
or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami -Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products, wind uplift resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's napx pr logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product C&atroVApprcwad:':.
or the Miami -Dade County Product Control Seal as shown below. • • • •• • • • •••
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
.••.
.
. • .
.... .. . • •
•• •
• .
•••• • •
•.
. •
.. .
. •
.. •• ..•
•
.
. .
••. •
.
1. This Notice of Acceptance. • •
. . .
.
• .
2. Any other documents required by the Building Official or applicable building code in ord'et to'property giraluate•the
installation of this materials.
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 7 of 9
•
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required
in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c.
Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of
membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -
nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 V."/12", precautions should
be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified
Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such dtAf. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should bernsl alultd in su h a way so . •
that water will run parallel to or over the top of all laps of the patch. ••••
•
•
10. All self -adhered membranes must be rolled to ensure full contact with approved subgtlifeY Polygla.s requires a..:
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Handl X011 ass are acoeptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prgllijit,s.rolling.. • •
11. All approved substrates should be dry, clean and properly prepared, before any appli'c'atl'oh of Pol;Iti k
membranes commences. An approved substrate technical bulletin can be furnished !pore request It Is.
recommended to refer to applicable building codes prior to installation to verify accgptabje subslrtteS. •
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick mem1*an8s carilte litrished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
.'•
. .
MIAMI•DADE COUNTY
APPROVED
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 8 of 9
•
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
• •
• • ••••
• • •
..• ••••
•
••••
•
• • •. •
••••• ..
.. •
• • • ..
...... •
...
• • • •
• •
•
• •
• •
•
• • • • •
• ..
• ..
NOA No.: 14-0717.08
Expiration Date: 09/13/16
Approval Date: 01/22/15
Page 9 of 9
MIAMI DE'
F'I
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.mia midade.gov/economy
The Dow Chemical Company
1605 Joseph Drive
200 Larkin Center
Midland, MI 48674
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: TILE BONDTM Roof Tile Adhesive
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
... •
RENEWAL of this NOA shall be considered after a renewal application has been filed and tl;ere bass been no change
in the applicable building code negatively affecting the performance of this product. • • • ••••
•
•
TERMINATION of this NOA will occur after the expiration date or if there has been a revisitlfee'hange in die
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsafeht of any Pl'gdtfc4, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to com Vith any%ectt&n of
this NOA shall be cause for termination and removal of NOA. "•• ••
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Ial'ori$ai and followed by
the expiration date may be displayed in advertising literature. If any portion of the NC)A i$ displaye0in it
shall be done in its entirety. •• •
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.14-0820.08 and consists of pages 1 through 8.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI•DADE COUNTY
APPROVED
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category:
Sub Category:
Material:
Roofing
Roof Tile Adhesive
Polyurethane
SCOPE:
This approves TILE BOND Roof Tile Adhesive as manufactured by The Dow Chemical Company as described in
this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building
code, do not exceed the design pressure values; as obtained by calculations in compliance with Roofing Application
Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using TILE BONDTM Roof Tile
Adhesive.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
TILE BONDTM Roof Tile N/A TAS 101 Single component polyurethane foam roof tile
Adhesive adhesive
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of TILE BOND roof tile adhesive.
MANUFACTURING LOCATION:
1. Wilmington, IL
PHYSICAL PROPERTIES:
•••• Property
r •
Density • • • • •
Comperes dive Strength • •
Tensile Strength
•
•
•'
• Wate; AbseQ,tion • • • • • •
Moistute Vapor Tradshlitsion
Dimeptip?i 1, Stabil • : • •
. •. •• .•
•
• •
• • • •
Close4Cull Conten' •
• •
. . •
Test
ASTM D 1622
ASTM D 1621
ASTM D 1623
ASTM D 2842
ASTM E 96
ASTM D 2126
ASTM D 2856
Note:: •t» .physical properties listed above are presented
by accepted ASTM test methods and are subject to
MIAMI.DADE COUNTY
APPROVED
Results
1.83 lbs./f1.3
14.31 psi
31.21bf @ 180°F, 65% RH for 120 days, concrete
to concrete
2.21% absorbed by Volume
3.00 Perm / Inch
-0.47% Volume Change @ -40°C., 2 weeks
-4.05% Volume Change @70°C., 100% Humidity,
2 weeks
86.3%
as typical average values as determined
normal manufacturing variation
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 2 of 8
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
IBA Consultants Inc. 4848-8 TAS 101 05/19/08
4848-7 TAS 101 05/19/08
4848-6 TAS 101 05/19/08
4848-5 TAS 101 05/19/08
4848-4 TAS 101 05/19/08
4848-3 TAS 101 05/19/08
4848-2 TAS 101 05/19/08
4848-1 TAS 101 05/19/08
Trinity ERD D9840.09.09 TAS 110 09/17/09
INSTALLATION:
1. TILE BONDTM Roof Tile Adhesive may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of TILE BONDTM Roof Tile Adhesive.
2. TILE BONDTM Roof Tile Adhesive shall be applied in compliance with the Component Application section and
the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of
TILE BONDTM Roof Tile Adhesive shall provide sufficient attachment resistance to meet or exceed the resistance
value determined in compliance with Miami -Dade County Roofmg Application Standards RAS 127. The
adhesive attachment data is noted in the roof tile assembly NOA.
3. TILE BONDTM Roof Tile Adhesive and its components shall be installed in accordance with Roofmg Application
Standard RAS 120, and The Dow Chemical Company TILE BONDTM Roof Tile Adhesive Operating Instruction
and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by The Dow Chemical
Company.
5. Pressure treated wood filler block shall be required on all eave course of all tile profiles .excett on two Woc••e•
barrel tile • • • •
6. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after•T .BOND1�$ Roof •
Tile Adhesive has been dispensed. • • • •
7. TILE BONDTM Roof Tile Adhesive placement and minimum patty weight shall be in actor carie with t1e • •
'Placement Details' herein. Each generic tile profile requires the specific placement noted•lierein. • • •
MIAMI•DADE COUNTY
APPROVED
•• •
• • • • •
•••
•• •• •
• • •
•
•
• •
•
••
• • • •
•
• •
•• • •••• • •
•
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 3 of 8
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. TILE BONDTM Roof Tile Adhesive can be used with flat, low, medium and high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of TILE BONDTM Roof Tile Adhesive roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F
F' MS
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
X21
—W
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
140_A1MS1 DADE CC -LINTY
APPROVED
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
. • •.
.
. .
••
. .
• •
.•
' TAIr t: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE
• •• ..••
' .. • a ile ' .••••
. •. Profile
•Flat
Placement
Detail
Minimum patty Weight
per tile (grams)
Contact Area
(Square inches)
/ to v•Profile • '
#1
11.1
19.5
Medium Profile • • •
#2
11.0
19.5
High lisoffili (Head •
High Profile (Nosa� • _ •
#3
22.0
11.0
39
19.5
Twoliege,Barrel
#4
11.6
20
MIAMI•DADE COUNTY
APPROVED
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 4 of 8
ADHESIVE PLACEMNT DETAIL
LOW (FLAT) PROFILE
DETAIL #1
MIAMI-DADE COUNTY
APPROVED
.. •
. • •
•.•• • ••
•• •
• • • • •
•• •• •• •
•
•
•
. .
• •
•
• •
• • • •
• • •
• • • • •
• • •
•• • •••• • •
• • •
•• •
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 5 of 8
MEDIUM PROFILE
DETAIL #2
.•..
• .
.... . .
• ••
• •
• •••• • • ••
• •
•
• • •
• • • •• ••••
•
•• • • • •
•• • ••.•
• •
• ••
•• • • . •
• •• •• ••
•
• •
• • • •
• • • •
• • • • •
• • •
• • •••• • ••
• • •
MIAMI•DADE COUNTY
APPROVED
NOA No.: 16-0222.01
Expiration Date: 0823/21
Approval Date: 04/14/16
Page 6 of 8
HIGH PROFILE
DETAIL #3
MIAMI•DADE COUNTY
APPROVED
• • ••••
• • • •
•• • •••• •
• •
••••
•••• •• •
• a • • •
•••• • ••
•• •
• • • • •
•• •• •• 0
• •
•
• 0
• • • •
• • • •
• • •
• • •
•• • ••••
• • •
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 7 of 8
•
BARREL PROFILE
DETAIL #4
• •
•••• • •
• • • •
• •••• • ••
• •
••••
•
• • •
• • • •
•.
• • .••••
•• • .••.
• •
••
•
• • • • •
• •• •• ••
••
• .••
• ••
• • • • •
• • •
• • •••• • ••
• • •
• ••
END OF THIS ACCEPTANCE
NOA No.: 16-0222.01
Expiration Date: 08/23/21
Approval Date: 04/14/16
Page 8 of 8
SECTION 1524
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402
govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor. The owner's
initial in the designated space indicates that the item has been explained.
2. 7/4 Renailing wood decks: When replacing roofing, the existing wood roof deck may have to
be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually
concealed prior to removing the existing roof system).
4. fn Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance; therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overfroyT• •
scuppers in accordance with the requirements of Sections R4402, R4403 and R41.3 : •••••
Owner/Agent's ignature Date
Property Address
Revised on 7/9/2009 LD;07/01/2015;
nat e ....'
• •
•• ••
AG /5- ®P• . •
Permit Number ••
• •
• • •
•• •
•
• •
gate• •
•.
• • •
•• •
•
•
••••
• • •
•• •
• •
•
••
• •
• •