Loading...
RF-16-11421 ENGINEQIING 4225 SW 71 Ave Miami. FI 33155 Tel: 786-398-9179 Fax: 786-800-2627 al roofinspection angmail.com LAB CERTIFICATION #16-0510.15 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 05/15/2017 Roofing Contractor ADONAI ROOFING INC. Job Address 1208 NE 95 ST MIAMI SHORES 33138 Owner's Name Type of Tile MONIER BANGAR DOUBLE ROLL Approximate Roof Height 12' feet Approximate Square Footage of Roof 14 Date Tested 05/15/2017 Contact Name MANUEL JARA Roof Pitch 3/12 ft2 Number of Tests 22 Permit # RF4161142 Date Installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 786-299-2807 LOCATION # OF TEST PASS # OF TEST FAIL Corner 4 Tests 4 Pass Test Fail Perimeter 4 Tests 4 Pass Test Fail Field 14 Tests 14 Pass Test Fail Ridge 0 Tests 0 Pass Test Fail TOTAL 22 Tests 22 Pass o Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. THIS TAS 106 TEST HAS BEEN PERFORMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADE COUNTRY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS. THIS REPORT IT IS NOT VALID FOR INSURANCE CLAIMS. YENAN T. LEYVA PE. 67416 e Job Address 1208 NE 95 ST MIAMI SHORES 33138 Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Parcel Number PROVE Expiration: 10/3102016 Applicant Owner Information Address Phone CeII PEDRO DE MELLO 1208 NE 95 Street MIAMI SHORES FL 33138- (305)753-5504 1208 NE 95 Street MIAMI SHORES FL 33138- Contractor(s) ADONAI ROOFING INC Phone CeII Phone (305)441-1365 Valuation: Total Sq Feet: $ 2,000.00 144 Type of Work: Re Roof Additional Info: Classification: Residential Scanning: 4 Fees Due CCF DBPR Fee DCA Fee Education Surcharge Permit Fee - New Roof Scanning Fee Technology Fee Total: Amount $1.20 $3.75 $3.75 $0.40 $250.00 $12.00 $1.60 $272.70 Pay Date Pay Type Invoice # RF -4-16-59570 05/04/2016 Credit Card 04/28/2016 Credit Card Amt Paid Amt Due $ 222.70 $ 50.00 $ 50.00 $ 0.00 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhe is • - .. • - above-named contractor to do the work stated. ignature: Owner / Applicant / Contractor / Agent Building Department Copy May 04, 2016 Date May 04, 2016 1 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 N Master Permit No. Re -15 Sub Permit No. RP Ro — 1 1 y 2- ❑ BUILDING ELECTRIC ► 4 ROOFING ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION D SHOP CONTRACTOR DRAWINGS JOB ADDRESS: /208 NE cift City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 1/3204,01'1Y/00 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Pdb Alen rif2c arr' de MG%� Phone#: 305- 7s3 SSo Y Address: i2.0e AIc ,S / City: MI F I7)i,J/)O!'eS State: Ft- Tenant/Lessee Name: Phone#: cAtu Email: Phone#: 7 B (o 390 0 /39 zip: 33/.38 CONTRACTOR: Company Natne: ! 'CIO 44 / /20 a 'Ai, ! h c_ Address: .230`7 So041.1 t7t»j1 % 4d s0I City: pa a State: (cc Zip: 33/ 4/C Qualifier Name: (/tri. T Gat 4t ' , . Phone#: State Certification or Registration #: OCC-' 13ZS8qCertificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Zi CC0 Square/Linear Footage of Work: Ir 4 y Type of Work: D Addition ❑ Alteration Description of Work: ZQ . )1/41e1200F`.1, L� New ❑ Repair/Replace ❑ Demolition Specify color of color thru tile: Submittal Fee $ - Permit Fee $ (3 - 03 CCF $ ) CO/CC $ pS Scanning Fee $ " 00 Radon Fee $ 3 7T-7 DBPR $ �' �S Notary $ Technology Fee $ \ . ' 0 Training/Education Fee $ c `fid Double Fee $ ° Structural Reviews $ cp Bond $ V ---Q i S / e q TOTAL FEE NOW DUE $ c aD ,--i0 (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. • . "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR. NOTICE OF .COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith;thata copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a cerfiied copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. `' Signatp �/ Signature. OWNER or AGENT The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this V day of (t0 , 20 t V , by eN day of / , 20 / G , by AciW ike..U. , who is personally known to C kJ— °kre.-i , who is Personally known to • me or who has produced as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: CIA O ############### APPROVED BY (Revised02/24/2014) # identification and who did take an oath. NOTARY PUBLIC: Sign: �'�-- Print 1&.vi. 9.44±s5--"*- • Seal: ve.°-`°vim. CLARA E RODRIGUEZ ,ft "= MY COMMISSION #FF138588 ........ EXPIRES July 5, 2018 (4W 3 i=4* Flplivai ** ### Plans Examiner Zoning Structural Review Clerk 003019 Local Business Tax Receipt Miami—Dade County, State of Florida -THIS IS NOTA BILL - DO NOT PAY 5222591 BUSINESS NAME/LOCATION ADONAI ROOFING INC 2307 5 DOUGLAS RD STE 501 MIAMI FL 33145 OWNER ADONAI ROOFING INC Worker(s) RECEIPT NO. RENEWAL 6458195 LBT EXPIRES SEPTEMBER 30, 2016 Must be displayed at place of business Pursuant to County Code Chapter 8A - Art. 9 & 10 SEC. TYPE OF BUSINESS PAYMENT RECEIVED 196 SPECIALTY BUILDING CONTRACTOR BY TAX COLLECTOR CCC1325896 $75.00 09/28/2015 CREDITCARD-1 5-050582 Thie Local Business Tax Receipt only confirms payment of the Local Business Ter:. The Receipt is not a license, permit, or a certification of the holder's qualifications, to do bestows. Holder must comply with any governmental or nongovernmental regulatory laws end requirements which apply to the business. The RECEIPT NO. above must be displayed an all commercial vehicles - Miami -Bede Code See 8a -V13. For more itdormadon, visit warw.miamldade.eovhturcofactot • CERTIFICATE OF LIABILITY INSURANCE 5/4 2016 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N. Holiday, FL 34691 (727) 938-5562 This Certificate is issued as a matter of information only and confers no rights upon the Certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. Insurers Affording Coverage NAIC # Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Holiday, FL 34691 Insurer A: Lion Insurance Company 11075 Insurers: Insurers: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the Insured named above for the policy period indicated. Notwithstanding any requirement, term or condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD Type of Insurance Policy Number Policy Effective Date (MM/DD/YY) Policy Expiration Date (MM/DD/YY) Limits GENERAL LIABILITY Commercial General Liability Each Occurrence $ Damage to rented premises (EA occurrence) $ Claims Made Occur Med Exp $ Personal Adv Injury $ General aggregate limit applies per: D Policy ❑ Project ❑ LOC General Aggregate $ Products - Comp/Op Agg $ AUTOMOBILE LIABILITY Any Auto All Owned Autos Scheduled Autos Hired Autos Non-Owned Autos Combined Single Limit (EA Accident) $ Bodily Injury (Per Person) $ Bodily Injury (Per Accident) $ Property Damage (Per Accident) $ EXCESS/UMBRELLA LIABILITY ROccur ❑ Claims Made Deductible Each Occurrence Aggregate A Workers Compensation and Employers' Liability Any proprietor/partner/executive officer/member excluded? NO If Yes, describe under special provisions below. WC 71949 01/01/2016 01/01/2017 X I WC Statu- I tory Limits 1OTH- ER E.L. Each Accident $1,000,000 E.L. Disease - Ea Employee $1,000,000 E.L. Disease - Policy Limits $1,000,000 Other Lion Insurance Company is A.M. Best Company rated A- (Excellent). AMB # 12616 Descriptions of Operations/LocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 84-65-672 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": Adonal Roofing, Inc. Coverage only applies to Injuries Incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s), while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 05-04-16 (TD) Begin Date 12/7/2015 CERTIFICATE HOLDER CANCELLATION VILLAGE OF MIAMI SHORES BUILDING DEPARTMENT 10050 NE 2ND AVENUE MIAMI SHORES, FL 33138 Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mall 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the insurer, Its agents or representatives. R* Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Seed n A Montreal Onf # atlen1 p ®. 1)---C a3- M 'S— Rump, No. Job ROOF CATEGO x �f Mechanically Fastened Tile r nor/ t z&solve ± rib 'Retei tl anei/$hingles ® Wood Shin >lealShaaes 11; Asphalt& Shingles frilew Rooff Lei Prescriptive BUR -RAS 150 RO F TYPE Are there Gas Vent Stacks? Yes Nozr•' Type: Nature:a LPGX Recovering (l Repair li Maintenance . RIOfF SYSTEM !INFORMis g oogArea (SF) Steep Sloes! Roof L t -t4 sq (SF) Total (SF) 1,464 5,9'4 - Section (Roof Plan) •••• Sketch Roof Plan: iiiussrata all levels �.; melons, roof drains, e�ul • acuppero end ov +i.,� d- no. Maks :t d nsloras of sections as i�1 identify dimensions of elevated pressure zones and location of para T« • • ••• ••.• • • •••• • t • 'e'/J] H ALL FEDERAL ROOF ASSEMBUES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: 5 /4-.e ark \ Le- 4' ar_ Notice of Acceptance Number: 9 1 p 2,_ 09 Minimum Design Wind Pressures, If Applicable licable (From RAS 127 or Calculations): aro PL P1: P1: — 100 \DeckTYPe: I-- SIt TIN 0004 )(S' Roof Slope: : 12 Ridge Ventilation? 1.4 to - Type Underlayment I s¶e 1 - 1 Insulation: tar Fire Barrier: L Mean Roof Height: \'4' f+ - Fastener Type & Spacing: 0, ( P Adhesive Type: 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 `?6L.( tris �}���;rt� i t!s:. I •. • p' Roof Covering: •bvt • • - • 1 •• •• .• • 1 Type Cap Sheet: ... Se. �' 1�.8. dt _ • . . .• • Type & Size Drip Edge: 89� %6A I Wt -4( 1 • 1' . • • . . .• • •• • FLORIDA BUILDING CODE — BUILDING, 5th EDITION (2014) 15.39 Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 2015 10:32:12 AM pursuant to License Agreement. No further reproductions authorized. INTERNATIONAL CODE COUNCIL' .• • . . • • • . • 1 1 1 11 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 5th Edition (2014) High -Velocity Hurricane Zone uniform Permit Application Form. 1 Section E (Tile Calculations) 1 For Moment based the systems, choose either Method 1 or 2. Compare the values for M with the values from M,. If the M, values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method is acceptable. 1 1 1 1 1 Method 1 "Moment Based Tile Calculations Per RAS 127" 0= M„ Product Approval M, Z6 . tx 0= M,) Z fQ Product Approval IA GI. 1 0= Ma ( Product Approval M, Z-.1 (Pfr34.I x O-67=JJ. 30 ) - Mg (P2-. 68-1 xx0-;:gy /q.69) - Mg (P3:)OO. x .Q =Z l.l) ) - Mg: Method 2 "Simplified Tile Calculations Per Table Below" 1 Required Moment of Resistance (Mr) From Table Below 1 Product Approval M,2. _ 1 0 1 1 1 1 1 1 1 1 1 1 1 *Must be u Appeals. Mr required Moment Resistance* • . • • : • Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 For Uplift based tile systems use Method 3. Compared the values for F' with the values for Fr. If the equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. .••. Cunt lB oard of REI9S and •• • •••• • F'U9IG$S tire greStbf Phan or 1 Method 3 "Uplift Based Tile Calculations Per RAS 127" •• • 1 (P1: x L = x w: )_W: xcos 0=Fr, Product Approval F' ••••••• (P2:xL=xw:= ) - W: xcos6 = F _ Product Approval F' .. • • • • 1 (P3: xL_=xw:= )-W xcos0 = Fa Product Approval F' 0 111 1 1 1 1 1 1 1 1 1 1 1 • • • •• • • • • • •• •• • • • • •. • • Where to Obtain Information • . • • : • Description Symbol Where t3 find' .- 7, - • Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre- pared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier a. Product Approval Restoring Moment due to Gravity M8 Product Approval Attachment Resistance M, Product Approval Required Moment Resistance MB Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. 15.40 INTERNATIONAL CODE COUNCIL • • • • FLORIDA BUILDING CODE - BUILDING, 5th EDITION (2014) Copyright to, or licensed by, ICC (ALL RIGHTS RESERVED); accessed by Eliezer Palacio on Jun 8, 201510:32:12 AM pursuant to License Agreement. No further reproductions authorized. MIAM WADE ' ail DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) Forterra Roof Tile, Inc. 1340 SW 34th Ave Deerfield Beach, FL 33442 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.2ov/pera SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile . • •• • . .••• •• • •••• • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, Al/ :Me and fdlydving • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. • • • ••••• •• • • • RENEWAL of this NOA shall be considered after a renewal application has been filed and thWe'lfas been'ho Mange in the applicable building code negatively affecting the performance of this product. • . • •' •' • •• ••• •• . TERMINATION of this NOA will occur after the expiration date or if there has been a revi a$ pt' change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement'of anprod 1st, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to with an%section of this NOA shall be cause for termination and removal of NOA. • • • ••• • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 12-0917.07 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMI DADE COUNTY APPROVED NOA No.: 15-1102.04 Expiration Date: 12/16/17 Approval Date: 12/10/15 Page 1 of 6 • • • • • • ROOFING ASSEMBLY APPROVAL Category: Roofmg Sub Category: Roofmg Tiles Material: Concrete 1. SCOPE This approves a roofing system using Hanson Hacienda Roof Tile, as manufactured by Forterra Roof Tile in Deerfield Beach, Florida and as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, do not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured byTest Product Applicant Dimensions Specifications Description Hanson "Hacienda" Trim Pieces ••.• • • Length: 17/" Low profile, interlocking, extruded concrete roof Width: 13" TAS 112 tile equipped with two nail hole and double roll '/2' thick ribs. For direct deck or battened nail -on, mortar or adhesive set applications. TAS 112 Accessory trim, concrete roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 1= varies w = varies varying thickness 2.1 MVPANUFACTURft' G LOCATION •••• • •• 2.1.1.:Deerfie1dJ k, FL • •• • • 2.2 1+ V1D NCE$IIB'NjITTED: •• • •••• • • . .Test Agency... Redland Technologies • • • • • • • • • • .•.. • .• • •• . . • • • •. • •• .. Professional Service Industries, Inc. The Center for Applied Engineering, Inc. MIAMI•DADE COUNTY APPROVED Test Identifier 7161-03 7161-03 7161-03 P0402 P0631-01 Letter Dated Aug. 1, 1994 224-47099 94-060B 94-084 25-7094-1 25-7094-7 25-7094-4 Project No. 307025 Test #MDC -76 Test Name/Report PA 102 PA 102(A) PA 108 Withdrawal Resistance Testing of screw vs. smooth shank nails PA 108 PA 108 PA 112 PA 101 PA 101 PA 102 PA 102 PA 102 PA 100 Date Dec. 1991 Dec. 1991 Dec. 1991 Sept. 1993 July 1994 Aug. 1994 Sept. 1994 March, 1994 May 1994 Oct. 1994 Oct. 1994 Oct. 1994 Oct. 1994 NOA No.: 15-1102.04 Expiration Date: 12/16/17 Approval Date: 12/10/15 Page 2 of 6 N. 2.2 EVIDENCE SUBNIITTED: Test Agency Celotex Corporation Testing Services Walker Engineering, Inc. IBA Consultants, Inc. American Test Lab of South Florida Test Identifier 25-7183-1 25-7183-2 25-7214-2 25-7214-6 528454-2-1 520109-2 Calculations 2381-249 RT1024.01- 11 Test Name/Report PA 102 PA 102 PA 102 PA 102 PA 101 Aerodynamic Multiplier TAS 112 TAS 112 Date Feb. 1995 Feb. 1995 March, 1995 March, 1995 Sep. 1998 Dec. 1998 March 1999 09/20/07 10/28/11 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix 'A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofmg Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope uni 'srstated •otherwise by the underlayment material manufacturers published literature. • • • ..• . .... 3.6 This acceptance is for wood deck applications. Minimum deck requirements shali ilia compliance with applicable building code. • MIAMI•DADE COUNTY APPROVED . . .... . . . • • • • . .. . . • . • • •. .. • • • • • ..• • • • . . NOA No.: 15-1102.04 Expiration Date: 12/16/17 Approval Date: 12/10/15 Page 3 of 6 4. INSTALLATION 4.1 Hanson `Hacienda' Roof Tile and its components shall be installed in strict compliance with Roofmg Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Hanson Hacienda Tile 10.0 1.4375 1.08 Table 3 Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile Table 2: Aerodynamic Multipliers - A. (ft3) 4": 12" Tile 6": 12" A. (ft3) X (ft3) Battens Profile Battens Batten Application Direct Deck Application Hanson Hacienda Tile Battens Direct Deck 0.267 0.289 Table 3 Restoring Moments due to Gravity - Mg (ft-Ibf) Tile Profile 3": 12" 4": 12" 6": 12" 6": 12" 7": 12" or greater Hanson Hacienda Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 "" Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) • • • • For Nail -On Systems .ti�e• • Profile • •• •. • X stener Type •••• Direct Deck (Min 16/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Hansgrl • ; Haciecda•Tile '•�••• • • • • •' •• •' . • •' 2-6141d Ring Shank Nails 27.8 37.4 28.8 1.1AdSmooth or Screw �••�•Shank Nail 8.8 11.8 4.1 tfmooth or Screw • Shank Nails 16.4 21.9 7.1 j #8 Screw 25.8 25.8 22.9 • "2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail (Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail (Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails (Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails (Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 43.0 67.5 50.9 1 Installation with a 4" tile headlap and fasteners are located a min. of 2W from head of tile. MIAMI•DADE COUNTY APPROVED NOA No.: 15-1102.04 Expiration Date: 12/16/17 Approval Date: 12/10/15 Page 4 of 6 Table 6: Attachment Resistance Expressed as a Moment Mt (ft-ibf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Hanson Hacienda Tile Adhesive' 26.13 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 3MT1" 2 -Component Foam Roof Tile Adhesive AH -160. Average 11.4 grams. weight per patty 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mr (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Hanson Hacienda Tile 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 86.614 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 45.55 4 Large paddy placement of 54 grams 5 Medium paddy placement of 24 grams Table 8: Attachment Resistance Expressed as a Moment - Mr(ft-Ibf) for Mortar or Adhesive Set Systems Tile Profile Tile Application Attachment Resistance Hanson Hacienda Tile Mortar Set • 20.6 e....• 5. LABELING • .• •• • •••• • • •••• All tiles shall bear the imprint or identifiable marking of the manufacturer's ndhie M' logo, or fallowing • • statement: "Miami -Dade County Product Control Approved". •••••• •• • •• • • •••• •• •• • • •• •• Hansom.._�..: HANSON HACIENDA ROOF TILE TILE IDENTIFICATION MARK (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. MANMADE COUNTY APPROVED NOA No.: 15-1102.04 Expiration Date: 12/16/17 Approval Date: 12/10/15 Page 5 of 6 • • • • • • • • • FASTENER HOLES PROFILE DRAWINGS OVERLOCK ... . . •... UNDERLOCK 13 . .... • . . .. • • • • • • • • .. • • • • .• •••• . •• • • ..• •••• • • • • • • .. • • .. • • • . • • • • •. • • • •••• • .. .. • MIAMI•DADE COUNTY APPROVED HANSON HACIENDA CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 15-1102.04 Expiration Date: 12/16/17 Approval Date: 12/10/15 Page 6 of 6 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.miamidade.Eov/economy Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments . • •• LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, cit j state add following • • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.• • • • RENEWAL of this NOA shall be considered after a renewal application has been filed and.tbese has been iao change• • • • • • • in the applicable building code negatively affecting the performance of this product. •••• • • • •• • • • • • • TERMINATION of this NOA will occur after the expiration date or if there has been a reVisibh or chat ge in the • materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product • • for sales, advertising or any other purposes shall automatically terminate this NOA. Failurato comply ldth'811y section • of this NOA shall be cause for termination and removal of NOA. • • • •• • • •• • • .• •• • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #12-0713.02 and consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY APPROVED NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Product Polystick MTS Manufacturing Location #2 Polystick MTS Plus Manufacturing Location #2 Polystick IR -Xe Manufacturing Location #1 & #2 Polystick TU Plus (Surface Printing) Manufacturing Location #1 & #2 Polystick TU P Manufacturing Location #2 Polystick Tile Pro Manufacturing Location #2 Polystick Dual Pro Manufacturing Location #2 Dimensions Roll: 65'8" x 3'33/8" 60 mils thick Roll: 65'8" x 3'3-3/8" 60 mils thick Roll: 65' x 3'3-3/8" Or 65' x 3' 60 mils thick Roll: 65' x 3'33/8" 80 mils thick Roll: 32'10" x 3'3-3/8" 130 mils thick Roll: 61' x 3'33/8" 60 mils thick Roll: 61' x 3'33/8" 60 mils thick Test Specification TAS 103 TAS 103 Product Description A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. A homogeneous, rubberized asphalt waterproofing membrane, glass fiber reinforced with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. ASTM D 1970 A fine granular/sand top surface self -adhering, APP polymer modified, fiberglass reinforced, bituminous sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice & rain shield. •••••• TAS 103 and ASTM A rubberized asphalt s81T adhering, M- D 1970 fiber/polyester reinfo;i; waterproong• • membrane. Designed aim, metal r44fing and r¢ef • • file underlayment. ' • • • • • • •..' •• . •. • • . • • • • TAS 103 and ASTM A rubberized asphalt ygi• tproofing r embrane, • • D 1970 glass-fiber/polyester b"einioi ced, with a granulas..:. surface designed for Ise gs p tile roof. underlayment. • • • .•' • TAS 103 and ASTM A rubberized asphalt self -adhering, glass - D 1970 fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. • . TAS 103 and ASTM A rubberized asphalt self -adhering, glass - D 1970 fiber/polyester reinforced waterproofing membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 2 of 9 PRODUCTS DESCRIPTION: Product Polystick TU Max Manufacturing Location #2 Elastoflex S6 G Dimensions Roll: 65'8" x 3'3-3/8" 60 mils thick Test Product Specification Description TAS 103 and ASTM A rubberized asphalt self -adhering, polyester D 1970 reinforced waterproofing membrane. Designed as a a roof tile underlayment. Roll: TAS 103 and ASTM Polyester reinforced, SBS modified bitumen 32' 10" x 3' 3-3/8" D6164 membrane with a burn off polyethylene or sanded back face and a granule top surface. For use in roof tile underlayment systems. MANUFACTURING PLANTS: 1.Hazelton, PA 2. W inter Haven, FL EVIDENCE SUBMITTED: Test Agency Trinity I ERD PRI Asphalt Technologies Momentum Technologies, Inc. Test Identifier P10870.09.08 -R1 P10870.04.09 P33360.06.10 P33370.03.11 P33370.04.11 P36900.09.11 P37300.10.11 P40390. 08.12-1 P40390.08.12-2 P40390.10.12 P37590.07.13-1 P45270.05.14 P46520.10.14 P44360.10.14 P43290.10.14 PUSA-035-02-01 PUSA-055-02-02 PUSA-089-02-01 JX20H7A RX14E8A DX23D8B DX23D8A Test Name/Report TAS 103 TAS 103/ASTM D4798 & G155 ASTM D1970 TAS 103 ASTM D 1623 TAS 103/ASTM D4798 & G155 TAS 110/ASTM D4798 & P 1 NVQ TAS 103 & TAS 110 •• • ASTM D 1623 • ASTM D 1970 ASTM D6164 TAS 103, TAS 110 & AS• D 1623 •••• . • •• •• ASTM D1623 • . • TAS 103 & TAS 110 • ASTM D 1970 & TAS •1.10 • TAS 103 TAS 103 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 TAS 103/ASTM D4798 & G155 Date 12/04/08 04/13/09 07/01/10 03/02/11 04/26/11 •i09101/11 • • 4Ew19/11 :7871®6/12 • il8/07/12 •• 1003/12; 11.7262/13 ..05/12/14 • • • • • • • • ••• • • m/03/14 •• •• •14/07/14 • • .•1.0/17/14• • • • • • • 09/29/06 12/10/07 07/06/09 04/01/08 11/09/09 02/18/10 02/18/10 NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 3 of 9 • INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(1) Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self -adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(2) Anchor sheet mechanically fastened to deck, membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Elastoflex S6 G, hot asphalt applied. Surfacing: See General Limitations Below. Deck Type 1: Wood, non -insulated Deck Description: Min. 19/32" plywood or wood plank System Type E(3) Base sheet mechanically fastened deck, subsequent cap membrane self+�he�ed. Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626. • • : • • ••:• Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at aplum 4" head lap. 4for . base sheet only) • • • • • • • • • • •• • • Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal lis: cl mininwm:6" vert] (Optional) laps.•••••` •••••• • Membrane: Polystick TU Plus, self -adhered. . .. • '• • • • • Surfacing: See General Limitations Below. •• • • • •• • •••• • • • • • NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 4 of 9 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-%2" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, Polystick MTS Plus, Polystick TU Plus, Polystick Tile Pro and Polystick Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR -Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. • • • .• •• • • • •••• •••• • •••• 1 • 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface..Tke.deck shall be free of . irregularities.•""• •• •• •. • • 5. Polyglass Polystick membranes and underlayments shall not be adhered directly ove,r.a pie -existing rpof • •• • • • • • membrane as a recover system. • • • • • • • 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for for ;ertrign the amok nt of days': • listed in the table below after application. Polyglass reserves the right to revise or alter productrkpti5we tires; . • • • not to exceed the preceeding maximum time limitations. • • • • • • • • • • Exposure Limitations (days) • • • MTS IR -Xe Elastoflex S6 G TU Plus TU P Tile Pro Dual Pro TU Max MTS Plus Winter Haven, FL. 180 90 180 180 180 180 180 90 180 Hazelton, PA. N/A 90 N/A 180 N/A N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. MIAMI•DADE COUNTY APPROVED NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 5 of 9 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU Plus, Polystick Tile Pro, Polystick TU Max or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9a. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Elastoflex S6 G Polystick TU Plus, TU P, Tile Pro, Dual Pro Polystick TU Max Polystick MTS Plus' Flat Tile Prohibited without battens 4:12 No limitation No limitation 5:12 Profiled Tile Prohibited without battens 4:12 No limitation No limitation 4:12 The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. 'The following limitations shall be apply when using Polystick MTS Plus: • Slopes up to those shown in the table above will require stagging of tiles — two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles. (See Figure 1 below) • Battens shall be used for stagging of lugged tiles above 4:12 • Battens shall be used for stagging of flat tiles above 5:12 J/ Slope Figure 1: Stagging Method •••• • • • • •••• • • • •• • •••• • •••• • • • •• • • •••• •• • • • • • • • •• • •••• • •• P • • •• •• • • • •• • • • • ••• • • • • • • • • •• • •••• • • 9b. There shall be no roof slope limitation for the Polystick MTS Plus / Polystick TU Plus two-ply underlayment system when a applied using the stagging method outlined above. NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 6 of 9 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. Roof Deck prepared wilt POLSSIICKlU Plus • Roofing Tiles (6 Max Per Stack) 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, Polystick MTS Plus, Polystick IR -Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, Polystick MTS Plus, Polystick IR -Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, Polystick MTS Plus, Polystick IR -Xe, Polystick TU Plus, Polystick TU P, Polystick TU Max, Polystick Dual Pro, Polystick Tile Pro or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's napx pr logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product C&atroVApprcwad:':. or the Miami -Dade County Product Control Seal as shown below. • • • •• • • • ••• BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: .••. . . • . .... .. . • • •• • • . •••• • • •. . • .. . . • .. •• ..• • . . . ••. • . 1. This Notice of Acceptance. • • . . . . • . 2. Any other documents required by the Building Official or applicable building code in ord'et to'property giraluate•the installation of this materials. NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 7 of 9 • POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back - nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 V."/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such dtAf. Patching membrane shall be a minimum of 6 inches in either direction. The repair should bernsl alultd in su h a way so . • that water will run parallel to or over the top of all laps of the patch. •••• • • 10. All self -adhered membranes must be rolled to ensure full contact with approved subgtlifeY Polygla.s requires a..: minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Handl X011 ass are acoeptable for rolling of patches or small areas of the roof. Brooming may be used where slope prgllijit,s.rolling.. • • 11. All approved substrates should be dry, clean and properly prepared, before any appli'c'atl'oh of Pol;Iti k membranes commences. An approved substrate technical bulletin can be furnished !pore request It Is. recommended to refer to applicable building codes prior to installation to verify accgptabje subslrtteS. • 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick mem1*an8s carilte litrished upon request by our Technical Services Department by calling 1 (800) 894-4563. .'• . . MIAMI•DADE COUNTY APPROVED NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 8 of 9 • 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE • • • • •••• • • • ..• •••• • •••• • • • •. • ••••• .. .. • • • • .. ...... • ... • • • • • • • • • • • • • • • • • • .. • .. NOA No.: 14-0717.08 Expiration Date: 09/13/16 Approval Date: 01/22/15 Page 9 of 9 MIAMI DE' F'I DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 www.mia midade.gov/economy The Dow Chemical Company 1605 Joseph Drive 200 Larkin Center Midland, MI 48674 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TILE BONDTM Roof Tile Adhesive LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. ... • RENEWAL of this NOA shall be considered after a renewal application has been filed and tl;ere bass been no change in the applicable building code negatively affecting the performance of this product. • • • •••• • • TERMINATION of this NOA will occur after the expiration date or if there has been a revisitlfee'hange in die materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsafeht of any Pl'gdtfc4, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to com Vith any%ectt&n of this NOA shall be cause for termination and removal of NOA. "•• •• ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Ial'ori$ai and followed by the expiration date may be displayed in advertising literature. If any portion of the NC)A i$ displaye0in it shall be done in its entirety. •• • INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.14-0820.08 and consists of pages 1 through 8. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMI•DADE COUNTY APPROVED NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 1 of 8 ROOFING COMPONENT APPROVAL Category: Sub Category: Material: Roofing Roof Tile Adhesive Polyurethane SCOPE: This approves TILE BOND Roof Tile Adhesive as manufactured by The Dow Chemical Company as described in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values; as obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using TILE BONDTM Roof Tile Adhesive. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications TILE BONDTM Roof Tile N/A TAS 101 Single component polyurethane foam roof tile Adhesive adhesive PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of TILE BOND roof tile adhesive. MANUFACTURING LOCATION: 1. Wilmington, IL PHYSICAL PROPERTIES: •••• Property r • Density • • • • • Comperes dive Strength • • Tensile Strength • • •' • Wate; AbseQ,tion • • • • • • Moistute Vapor Tradshlitsion Dimeptip?i 1, Stabil • : • • . •. •• .• • • • • • • • Close4Cull Conten' • • • . . • Test ASTM D 1622 ASTM D 1621 ASTM D 1623 ASTM D 2842 ASTM E 96 ASTM D 2126 ASTM D 2856 Note:: •t» .physical properties listed above are presented by accepted ASTM test methods and are subject to MIAMI.DADE COUNTY APPROVED Results 1.83 lbs./f1.3 14.31 psi 31.21bf @ 180°F, 65% RH for 120 days, concrete to concrete 2.21% absorbed by Volume 3.00 Perm / Inch -0.47% Volume Change @ -40°C., 2 weeks -4.05% Volume Change @70°C., 100% Humidity, 2 weeks 86.3% as typical average values as determined normal manufacturing variation NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 2 of 8 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date IBA Consultants Inc. 4848-8 TAS 101 05/19/08 4848-7 TAS 101 05/19/08 4848-6 TAS 101 05/19/08 4848-5 TAS 101 05/19/08 4848-4 TAS 101 05/19/08 4848-3 TAS 101 05/19/08 4848-2 TAS 101 05/19/08 4848-1 TAS 101 05/19/08 Trinity ERD D9840.09.09 TAS 110 09/17/09 INSTALLATION: 1. TILE BONDTM Roof Tile Adhesive may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of TILE BONDTM Roof Tile Adhesive. 2. TILE BONDTM Roof Tile Adhesive shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of TILE BONDTM Roof Tile Adhesive shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofmg Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. TILE BONDTM Roof Tile Adhesive and its components shall be installed in accordance with Roofmg Application Standard RAS 120, and The Dow Chemical Company TILE BONDTM Roof Tile Adhesive Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by The Dow Chemical Company. 5. Pressure treated wood filler block shall be required on all eave course of all tile profiles .excett on two Woc••e• barrel tile • • • • 6. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after•T .BOND1�$ Roof • Tile Adhesive has been dispensed. • • • • 7. TILE BONDTM Roof Tile Adhesive placement and minimum patty weight shall be in actor carie with t1e • • 'Placement Details' herein. Each generic tile profile requires the specific placement noted•lierein. • • • MIAMI•DADE COUNTY APPROVED •• • • • • • • ••• •• •• • • • • • • • • • •• • • • • • • • •• • •••• • • • NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 3 of 8 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. TILE BONDTM Roof Tile Adhesive can be used with flat, low, medium and high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of TILE BONDTM Roof Tile Adhesive roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F F' MS 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. X21 —W LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. 140_A1MS1 DADE CC -LINTY APPROVED BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. . • •. . . . •• . . • • .• ' TAIr t: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE • •• ..•• ' .. • a ile ' .•••• . •. Profile •Flat Placement Detail Minimum patty Weight per tile (grams) Contact Area (Square inches) / to v•Profile • ' #1 11.1 19.5 Medium Profile • • • #2 11.0 19.5 High lisoffili (Head • High Profile (Nosa� • _ • #3 22.0 11.0 39 19.5 Twoliege,Barrel #4 11.6 20 MIAMI•DADE COUNTY APPROVED NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 4 of 8 ADHESIVE PLACEMNT DETAIL LOW (FLAT) PROFILE DETAIL #1 MIAMI-DADE COUNTY APPROVED .. • . • • •.•• • •• •• • • • • • • •• •• •• • • • • . . • • • • • • • • • • • • • • • • • • • • •• • •••• • • • • • •• • NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 5 of 8 MEDIUM PROFILE DETAIL #2 .•.. • . .... . . • •• • • • •••• • • •• • • • • • • • • • •• •••• • •• • • • • •• • ••.• • • • •• •• • • . • • •• •• •• • • • • • • • • • • • • • • • • • • • • • •••• • •• • • • MIAMI•DADE COUNTY APPROVED NOA No.: 16-0222.01 Expiration Date: 0823/21 Approval Date: 04/14/16 Page 6 of 8 HIGH PROFILE DETAIL #3 MIAMI•DADE COUNTY APPROVED • • •••• • • • • •• • •••• • • • •••• •••• •• • • a • • • •••• • •• •• • • • • • • •• •• •• 0 • • • • 0 • • • • • • • • • • • • • • •• • •••• • • • NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 7 of 8 • BARREL PROFILE DETAIL #4 • • •••• • • • • • • • •••• • •• • • •••• • • • • • • • • •. • • .•••• •• • .••. • • •• • • • • • • • •• •• •• •• • .•• • •• • • • • • • • • • • •••• • •• • • • • •• END OF THIS ACCEPTANCE NOA No.: 16-0222.01 Expiration Date: 08/23/21 Approval Date: 04/14/16 Page 8 of 8 SECTION 1524 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 2. 7/4 Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 4. fn Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overfroyT• • scuppers in accordance with the requirements of Sections R4402, R4403 and R41.3 : ••••• Owner/Agent's ignature Date Property Address Revised on 7/9/2009 LD;07/01/2015; nat e ....' • • •• •• AG /5- ®P• . • Permit Number •• • • • • • •• • • • • gate• • •. • • • •• • • • •••• • • • •• • • • • •• • • • •