Loading...
RF-17-1689 �rmrt arc 7- 1�9 Miami Shores Village _ 7-yB= 00 S.� 10050 N.E.2nd Avenue NE Caj#' T Miami Shores,FL 33138-0000 ;rMt 'PR VED a � Phone: (305)795-2204 Expiration: 12/26/2017 ue cam iss :6129126 p� Project Address Parcel Number Applicant 1098 NE 96 Street 1132060143460 PAUL AND SUZY MOSHEIM Miami Shores, FL 33138- Block: Lot: Owner Information Address Phone Cell PAUL AND SUZY MOSHEIM 1098 NE 96 ST (305)757-8233 MIAMI SHORES FL 33138-2552 Contractor(s) Phone Cell Phone Valuation: $ 28,550.00 CHERRY ROOFING ENTERPRISES INI (954)963-2741 (954)658-9878 _. __._. _ Total Sq Feet: 3800 Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF TILE Inspection Type: Classification:Residential Up Lift Report Scanning:3 Tin Cap Final Roof Tile In Progress Review Roof Renailing Affidavit Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-6-17-64439 CCF $17.40 06/29/2017 Check* 1376 $50.00 $840.16 DBPR Fee $4.88 DCA Fee $4.88 06/29/2017 Check#:1375 $840.16 $0.00 Education Surcharge $5.80 Bond#:3444 Permit Fee-New Roof $325.00 Scanning Fee $9.00 Technology Fee $23.20 Total: $890.16 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futh rzn ,I authorize the above-named contractor to do the work stated. j- a ZBi^'�� June 29,2017 Authorized Signature:Owner / Applicant / Contractor / Agent Date Building Department Copy June 29,2017 1 Miami Shores Village RECEIVED Building Department JUN 2 9 2017 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 Q" INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 201`1 BUILDING Master Permit No. 1 —4 Sol PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC EZ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: %OR% 111t- IA6- !�)r City: Miami Shores County Miami Dade Zia: Folio/Parcel#: kk - �`l.®�.-��19 — & U12 Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder):�t7.'j M-041 '\rn Phone#: 05 -}HCl. Address:0Q)(DL6 SLA- SV City: 4axyxk S\11Vz)M1b1 State: �� Zip: Tenant/Lessee Name: Phone#: '�"S%st Email: n CONTRACTOR:Company Name: Phone#:R'54 Address: City: "Qt-,V State: V- . Zip: Qualifier Name: c Phone#: State Certification or Registration Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State Zip: Value of Work for this Permit:$ VG- . 5Q-cv ✓ Square/Linear Footage of Work: ,two Type of Work: ❑ Addit ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: k Specify color of color thru tile: Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 'WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first insp ection which ac rs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will ni it be approved at a reinspection fee will be charged. b� — Signature Signature OWNER or AGENT ONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of TWVZ1 .20 1. •by Z'I— day of 3CA N(:;;7 .20 IT by ,?AtAL- mos"&"A ,who is personally known to mQ,�-$ S ck�c RI-q ,who is personally known to me or who has produced D L— as me or who has produced 0 (-- as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print:45'rAnixrit7 . Print: g�/rir s;r C�oie Seal: Seal: ;;•�"" ;; JENNIFER D COLE , : JENNIFER D COLE 'i MY COMMISSION#G 49278 MY COMMISSION#GG049278 MIN" r APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Miami shores Village ... p.,M Building Department ~ ` 10050 N.E.2nd Avenue oRi Miami Shares, Florida 33138 Tel. (305) 795,2204 Fut: (305) 756.8972 WLNE S'S AFFIDAVIT OF UEMPTION ROOF TO WALL CONNECTION HURRICANE"MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY,RESIDENTIAL STRUCTURES PER ANT TO SECTION$9.844 F.S. To. Miami Shores Village Building Department Date. --23-'ZOl`�— 10050 NE 2nd Ave Miami.Shores, FI 33138 Re; Owners Name: ?C�� rk�s'lacn Property Address.�b�-i� ►°�L� a � Roofing Permit Number: Dear Building Official: I pw."�A mncz�m cerft'fy that l:am not required-to retrofit the roof to wail connections of my building because: gThe just valuation for the structure for purpose of ad valorem taxation is less than$300.,000.00. Please attach proof of ad valorem taxation. J0 The building was constructed in compllance...with the provisiotns of the Florida Building Code(FBC)orwith tho provisions of 994 edition i if the A FloridaBuilding Cede{1994 SFBC) Signature Print Dame State of Florida County of Dade The undersigned, being the first duly sworn,deposes and says that he/she is the-owner for the above property mentioned, Sworn to and subscribed before me this -day of :S iW ,.,00'Y� JENNIFER D COLE Notary Public, Sate of Florida at large . . EXPIRES November 21,2020 • When the justvstuation offhe shucriue for 'utp IM, Is-equal fo ormorethan 0. �andthe buftrg was not const ctod wM F.BC nora 1994 S>BC.The you.must Rrovide a beUtl3ng app>sa a nerf contractor for tha Rwf to Wall connection Hurricane tkk 6n Revised on 50)2009 Prope Search Application-Miami-Dade County Page 1 of 1 011FICE OF Summary Report Generated On:6/29/2017 l HU Property Information Folio: 11-3206-014-3460 �T� 511 t F Property Address: 1098 NE 96 ST Miami Shores,FL 33138-2552 Owner PAUL MOSHELM&W SUZY 1098 NE 96 ST Mailing Address , = 42 MIAMI SHORES,FL 33138-255241x PA Primary Zone 1400 SGL FAMILY-3001-3250 SQ $ f 0101 RESIDENTIAL-SINGLE Primary Land Use e FAMILY:1 UNIT Beds/Baths!Half 4/3/0 r} .F-�•, � '4 j r Floors 2 Living Units 1 y Actual Area Sq.Ft El .. .._ y. Living Area Sq.Ft Adjusted Area 3,607 Sq.Ft Taxable Value Information Lot Size 18,961.8 Sq.Ft 2017 2016 2015 Year Built 1925 County Assessment Information Exemption Value $50,000 $50,000 $50,000 Year 2017 2016 2015 Taxable Value 1 $363,619 $355,112 $352,296 Land Value $682,294 $701,630 $578,707 School Board Building Value $258,803 $260,735 $262,6671Exemption Value $25,000 $25,000 $25,000 XF Value $41,389 $41,756 $29,394 Taxable Value $388,619 $380,112 $377,296 Market Value $982,486 $1,004,121 $87 0 7681 City Assessed Value $413,619 $405,112 $402,296 Exemption Value $50,000 $50,000 $50,000 Taxable Value $363,619 $355,112 $352,296 Benefits Information Regional Benefit Type 2017 2016 2015 Exemption Value $50,000 $50,000 $50,000 Save Our Homes Assessment Taxable Value $363,619 $355,112 $352,296 Cap Reduction $568,867 $599,009 $468,472 Homestead Exemption $25,000 $25,000 $25,000 Sales Information Second Exemption $25,000 $25,000 $25,000 Previous Sale Price OR Book-Page Qualification Description Homestead 06/01/1996 $300,000 17248-1353 Sales which are qualified Note:Not all benefits are applicable to all Taxable Values(i.e.County, 05/01/1984 $240,000 12135-1327 Sales which are qualified School Board,City,Regional). 04/01/1978 $125,000 09998-1667 1 Sales which are qualified Short Legal Description MIAMI SHORES SEC 3 PB 10-37 LOT 1 BLK 81 LOT SIZE IRREGULAR OR 17248-1353 0696 1 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp Version: http://www.miamidade.gov/propertysearch/ 6/29/2017 Ty SECTION 1024 U PY mGH vELOCITY`HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOk ROOFING CO}NSIDERATiONS 1524.1 Scope,As:'it pertains to the section,it is the responsibility of roofing contractor to provide the owner with the required roofing permits and to explain to the owner the content of the section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system Installations.Additionally;the following items should be addressed as .part of"ttte.agreement between the owner ant the contractor.The owner's initial in the designated space indleates that the item has been explained. 2. Renailing decks:When replacing roofing,the existing wood roof deck.may have to be renailed in accordance with the current provisions of Section 84403.(The-roof dear is usually concealed`prior to removing the existing roof system). 4 f t_4 !Exposed Ceiling.Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to.maintain;#tie architectural appearance;therefore, roofing nail penetration of the underside of the decking ruby not:be acceptable.This provides the option of maintaining the appearance. 6. U Ovat#low scuppers(wall outlets);It It required that rainwater flows off so that the roof is not overloaded from.a buildup of water.Pedmetertedge wail or other roof extension may block this discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accordance:with the requirements of Sections 84402,84403 and 114413. . �L d I �0 wn nts Signature, Date: Contractor S' tore Dafe 1®q% NC 'Diu_ G - _ Properly:Address Permit Number Revised on 7/9/2009 LD;07/01/2015; Florida Building Code Edition 2014 , High Velocity Hurricane Zone- Uniform Roofing Application For AM 9 r I ■■■■■■■■■■■■■■■■■■■ ■_��■� ���■■■■■■■■■■■■■soon■■ ■■nNNNNN■NNW■■■■f �NNn■■■n�■nNn �Nn■■■INNN■■■■■■■■ I ■■■■■■■■■■■■■■�■■■■■NSI■■■■■■■■■■■■■■■■■�■■■NINE ■■■■■■■■■Nn■'■N■►NnnNnnss■■■■■■■■■■■■I■r■o■gin■■■ ■■s■■■N■■■■■��■■■� sno■■■■■o■■■■s■■■■nlnn■■�s■■n ■■■■■■■■■■■ors■■■■s�■■■■soEi�rss■��■�■■■■■■ :.:. .7 s■■■■■■■■■■■■■■■■ns■jn�■N■■■fn_o n--_-WAN. .s ..,..rrs��•t1iCEaiW31-'L��..�� n������N■N��nNNNn■N■aNn■■n■n����sQ■�����en_nN��_iN■�-WWII■ t Florida Building Code Edition 2014 High Velocity Hurricane Zone• Uniform Roofing Application Form Section D,(Steep Sloped Roof System) Roof System Manufacturer: '%A Q--kov'�z Product Approval Number: Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): 131:-VO, 132• •-b%' � P3: -►OO•�- Maximum Design Pressure Product Approval Specific System: Method of Tile Attachment: V� ►Q-^ C��CIx! ��� c�-��arn Steep Sloped System Descri tp ion Deck Type: Roof Slope: Type Underlayment: 12 Insulation: Fire Barrier Fastener Type&Spacing: 119Pf-0%4C- cA-P IV Q a5 �- Ridge Ventilation? M � 2 o A (7-UW6 , Af. Adhesive Type: f�f �C Type Cap Sheet: Roof Covering: _, r► L . Mean Roof Height: 1;� Type&Size Drips Edge: Florida Building Code 5th Edition 2014 HIGH VELOCITY HURRICANE ZONE UNIFORM ROOFING PERMIT APPLICATION SECTION E (Tile Calculations) For moment based tile systems,chose either Method for 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" PI:3,31°t x X ®•--7XDA = 11.1691 ) -Mg:` -20 =Mrl: 0 1 NOA Mf: 7 Pz: x.% �,Q% =7Q•4CK 1 )-Mg: =Mr1:1 . 1 NOA M f: P3: 100 `� x� ®�� 1 ='30.310 -)-Mg: :a.d a =Mrl: 23.31 aV NOA Mf: 3� •"�- Method 2"Simplified Tile Calculation Per Table Below" 3& Required Moment of Resistance(M,)From Table Below: 7s 7- NOA Mf: Mr Required Moment Resistance* Mean Roof Height Roof Slope 15 20' 25' 30' 40' 2:12 .4 36.5 38.2 39.7 42.2 :12. 34.4 36.0 37.4 39.8 :12 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 1 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *This table must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For uplift based tile systems use Method 3. Compare the values for F'with the values for Fr.If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. Method 3"Uplift Based Tile Calculations Per RAS 127" (Pl: x 1: = x w: -w: x cos 0: =Fri: NOA F': (PZ: x 1: = x w: -w: x Cos 0: =Frz NOA F': (P3: x 1: =-xw: -w: x cos 0: =Fr3 NOA F': Where to Obtain Information Description Symbol Where to Find Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by a P.E.based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier x NOA Restoring Moment due to Gravity M NOA Attachment Resistance Mf NOA Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' NOA Required Uplift Resistance Fr Calculated Average Tile Weight W NOA Tile Dimensions 1=length NOA w=width All calculations must be submitted to the Building Official at the time of permit application. A � RECEIVE® I I JUN 2 91017 MIAMI-DARE COUNTY RODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Willot 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) adade.eov/economy Boral Roofing,LLC 7575 Irvine Center Drive,Suite 100 Irvine,CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.12-0222.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 16-0711.01 ruar�lnaoeeolnvrr Expiration Date: 04/26/22 -1 PPROVEDI Approval Date: 10/27/16 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Barcelona 900 Concrete Roof Tile,as manufactured Boral Roofing LLC in Lake Wales,FL and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barcelona 900 Length= 17" TAS 112 High profile,interlocking,one-piece,'S'shaped, Width= 13" Type—1 a high-pressure extruded concrete roof tile 1/Z"thick equipped with three nail holes. For direct deck or battened nail-on,mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length:varies TAS-112 Accessory trim,boosted Barcelona,concrete Width:varies roof pieces for use at hips,rakes,ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales,FL 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102&TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix H TAS 108(Nail-On) Redland Technologies P0402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108(Nail-On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108(Mortar Set) NOA No.: 16-0711.01 IAMFDADE COUNTY Expiration Date: 04/26/22 �� ...� Approval Date: 10/27/16 Page 2 of 7 i k Professional Service Industries,Inc. IC-1320-94 Physical Properties Feb. 1995 TAS 112 The Center for Applied Engineering,Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied Engineering,Inc. 25-7688-5 Static Uplift Testing June 1996 TAS 102 (3"Headlap,Nails,Direct Deck,New Construction) The Center for Applied Engineering,Inc. 25-7688-4 Static Uplift Testing June 1996 TAS 102 (4"Headlap,Nails,Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering,Inc. Calculations Aerodynamic Multiplier 09/01/16 Walker Engineering,Inc. Evaluation Restoring Moments Due to 09/01/16 Calculations Gravity American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may required,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix `A'. Such testing shall be submitted to the Department of Regulatory and Economic Development —Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 16-1711.01 tinnuecounerY Expiration Date: 04/26/22 _I_APPROVEDI Approval Date: 10/27/16 Page 3 of 7 e 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119,and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight W(Ibf) Length-I (ft) Width-w(ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -A(ft) Tile Profile k(ft) A (ft3) Batten Application Direct Deck Application Barcelona 900 0.286 0.301 Table 3: Restoring Moments due to Gravity-M9 (ft-lbf) Tile 2"•12" 3"•12" 4"•12" 51'•12" 6"•12" 7"•12" or Profile greater Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 900 Deck Deck Deck Deck Deck Deck 6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 6.60 5.76 6.42 Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank 5.1 6.8 2.8 Nail 2-10d Smooth or Screw Shank 6.9 9.2 7.3 Nails 1 #8 Screw 20.7 20.7 18.1 2#8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw Shank 23.1 23.1 19.0 Nail Field Clip) 1-10d Smooth or Screw Shank 29.3 29.3 24.0 Nail Eave Clip) 2-10d Smooth or Screw Shank 27.6 27.6 38.6 Nails Field Clip) 2-10d Smooth or Screw Shank 38.1 38.1 41.8 Nails Eave Clip) NOA No.: 16-0711.01 htu MMADe eouNTY Expiration Date: 04/26/22 ,.. Approval Date: 10/27/16 Page 4 of 7 Table 5: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2 1 Installation with a 4"tile headlap and fasteners are located a min.of 2'/z"from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Adhesive' 29.32 1 See manufactures component approval for installation requirements. 2 TILE BONDTm Roof Tile Adhesive;Average weight per paddy 10.7 grams. ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160;Average weight per paddy 8 grams. Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 ICP Adhesives Pol set AH-160 66.53 ICP Adhesives Pol set AH-160 38.74 3 Large paddy placement of 63 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160. 4 Medium paddy placement of 24 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Pol et AH-160. Table 8: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Barcelona 900 Mortar Sets 24.5 6 Seespecific mortar manufacturers Notice of Acceptance NOA No.: 16-0711.01 Caaane coufvnr Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 5 of 7 a 1 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 16-0711.01 Mu►Mi Wane cotmnr Expiration Date: 04/26/22 J A P P ROVEDi Approval Date: 10/27/16 Page 6 of 7 PROFILE DRAWING NAIL' S t3VEFYl.. Awi, �i7 A 3 UNQEIROCK ' 'J BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 16-0711.01 rE coutvrir Expiration Date: 04/26/22 Approval Date: 10/27/16 Page 7 of 7 MIAMI-DADS COUNTY M PRODUCT CONTROL SECTION in 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy ICP Adhesives and Sealants,Inc. 12505 NW 441 Street Coral Springs,FL.33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polysee AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 raar�aw4uE ccwr�ertr Expiration Date: 05/10/22 Approval Date:04/27/17 Page 1 of 11 IL ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP Adhesives Polyset'AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive Polyset'AH-160 ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPacV N/A Dispensing Equipment 30& 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset'AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.61bs./fft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft' Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 ruarLtine 9)*NCO Expiration Date: 05/10/22 ' Approval Date:04/27/17 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset'AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 M1,4Mt�apeCou�rrr Expiration Date: 05/10/22 _]APPROVED Approval Date:04/27/17 Page 3 of 11 A S INSTALLATION: 1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset, AH-160. 2. ICP Adhesives Polyset,AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants,Inc. ICP Adhesives and Sealants,Inc.shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A"component and the"B"component shall be maintained between 1.0-1.15 (A): 1.0(B). 6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPack®30& 100 dispensing equipment only. 7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset®AH-160 has been dispensed. 9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 t+�AMti�d1DECOUMY Expiration Date: 05/10/22 JAPPROVED Approval Date:04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65 Profiles Flat,Low,High Profiles #1 17-23 sq.inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq.inches at 12 grams per paddy head of tile 9-11 sq.inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq.inches each bead Two Piece Barrel(Pan Tile) Two Piece j 65-70 sq.inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. BUILDING PERMIT REQummENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 NIIAMhQADECOUNrIY Expiration Date: 05/10/22 APPROVED Approval Date:04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL# 1 1 Flat/Low Profile Tile p ." 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown, � under the strengthening rib closest to the overlock Ilam of the tile being set. 2. Continue in same manner.Insure approximately 17 f R (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. To Medium Profile/ Double Pan Tile �t 1. Starting at the eave course,apply a minimum 2" _.; (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the " overlock of the tile being set. 84 s 2. Continue in same manner.Insure approximately 17 (109.7 cm)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. Is High Profile/Single Pan Tile ® 1. Starting at the eave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown sit under the pan portion of the tile closest to the overlock of the tile being set. e F 2. Continue in same manner.Insure approximately 17 (109.7 cm)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. Weaubde dom NOA No.: 17-0322.03 raa�aan�oEcoutvtY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 6 of 11 ADHESIVE PLACEMENT DETAIL#2 Rawfamb) Flat/Low Profile Tile 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlook of the file being set.Insure approximately 17(109.7 cm2) 23 (148.4 cm2)square inch adhesive contact with the R.Kank Gran" underside of the tile. EM ° 2. At the second course,apply a minimum 2"(50.8mm) air x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the file being set. 3. Continue in same manner.Insure approximately 10" (64.5 cm2)- 12(77.4 cm)square inch adhesive contact with the underside of the rile. Medium Profile/Double Pan Tile a 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 nun)foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set.Insure approximately 17(109.7 cm)— 7 23 (148.4 cm2)square inch adhesive contact with the w underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) tom. x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner.Insure approximately 12" (77.4 cm2)- 14(90.3 cm2)square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 MIAMtiQADE COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 7 of 11 ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) High Profile/Single Pan Tile 1. Starting at the eave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set.Insure approximately 17(109.7 cm2)— "" "�� 23 (148.4 cm)square inch adhesive contact with the underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) 1 x 7"(177.8 mm)x 1"(25.4 nun)foam paddy onto the ' underlayment positioned as shown under the pan t � '2b dwom portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner.Insure approximately 17" (109.7 cm2)- 19(122.6 cm)square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 MIAMFW►DECOUMY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 8 of 11 r - � ADHESIVE PLACEMENT DETAIL#3 1. On the eave course only,apply a minimum 2" (50.8 mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy p onto the underlayment positioned as shown,under the strengthening rib for flat tile or under the pan portion of the the for low or high profile the closest to the overlock of the tile being set.Leave =4 approximately 4"(10 1.6 mm)up from the eave edge free of foam to prevent the expanded adhesive � �- from blocking the weep holes. Insure a ,:z approximately 17-23 int(109.7-148.4 cm2)of adhesive contact with the underside of the tile 2. Apply a 4"(101.6 mm)x 4" (101.6 mm)x 1" (25.4 mm)foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile,or under the pan portion of the tile,closest to the underlock for t the second course file to be installed. Insure approximately 8-9 int(51.6-58.1 cm2)of adhesive contact with the underside of the tile. (Instructions continued on next page) •�"' `$a4hL .. o ate. , R%KftMPWftTft NOA No.: 17-0322.03 WDAUEcoExpiration Date: 05/10/22 Approval Date:04/27/17 Page 9 of 11 ADHESIVE PLACEMENT DETAIL#3 (CONTINUED) Iert0e tohm3. Also apply a 2"(50.8 mm)x 4"(101.6 mm)x3/4" Alftouftemfto (19 mm)paddy on top of the eave course tile enma� surface as shown,on top of the strengthening rib ° for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9(58.1 cmZ)- 11 (71cm2)square inch adhesive contact with the underside of the tile at the overlap 294 and 7(45.2 cm)-9(58.1 cmZ)square inch adhesive contact with the underside of the tile at the head of the tile.Continue in same manner. r hL r�e•s�: Ddpedp Hlopnmm NOA No.: 17-0322.03 MuuraaouaoE COUNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 10 of 11 Y ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan)Tile 1. Starting at the eave course,apply a minimum 2" ll""OonouoadhesWetoaddt%vOSW70sq.1a, SweppWhappIcaSm (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam �► a� ►tea z1 ,► :aaan��wa.; paddy onto the underlayment positioned as � ,;tna.tstda••teotc •re0e. shown under two adjacent pan tiles. Support eave ns�u•.emto. tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2)—70(451.6 cm2) square inch adhesive contact with the underside of the pan tile. t t: 3. Turn covers upside down exposing the underside w of the tile.Apply a minimum 1"(25.4 mm)x 10" cad (254 mm)bead of adhesive directly on the inner ttt�ii ,atereawtt�.xeae.iosem»d edge of each side of the cover tile.Leave approximately 3/4"(19 mm)to 1"(25.4 mm) .wo.Ple Barrel-High PmfileTflo from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course.Insure a minimum of 20(129 cm2)-25 (161.3 cm2)square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required,2"(50.8 mm)x 4"(101.6 mm)nailers or the tie wire system using galvanized,stainless steel,or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 17-1322.03 Mwe� ►uE counmr Expiration Date: 05/10/22 JAPPROVED Approval Date:04/27/17 Page 11 of 11 MIAMM MIAMI-DARE COUNTY MEW PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www•ndamidade.gov/economy Polyglass USA Inc. 1111 W.Newport Center Drive Deerfield Beach,FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 1 of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Material: SBS ,APP Self-Adhering Modified Bitumen PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick IR-Xe 65'x 313-3/8,, ASTM D 1970 A fine granular/sand top surface self-adhering,APP Manufacturing Or 65'x 3' polymer modified,fiberglass reinforced,bituminous Location#1 &#2 60 mils thick sheet material for use as an underlayment in sloped roof assemblies. Designed as an ice&rain shield. Polystick Dual Pro 61'x 3'3 3/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a Location#2 metal roofing and roof tile underlayment. Polystick Tile Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal Location#2 roofing and roof tile underlayment. Polystick TU Max 65'8"x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhering,polyester reinforced Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile Location#1 &#2 underlayment. Polystick TU P 32'10"x 313/8' TAS 103 and A rubberized asphalt waterproofing membrane,glass- Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced,with a granular surface Location#2 designed for use as a tile roof underlayment. Polystick TU Plus 65'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester (Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal Manufacturing roofing and roof tile underlayment. Location#I &#2 Polystick MTS 65'8"x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film Location#2 on the upper surface for use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Polystick MTS Plus 65'8"x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film Location#2 on the upper surface for use as an underlayment for metal roofing,roof tile,slate tiles and shingle underlayment. Elastoflex S6 G 32'10"x 313/8' TAS 103 and Polyester reinforced,SBS modified bitumen membrane Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For Location#2 use in roof tile underlayment systems. NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 2 of 8 q 1 � MANUFACTURING PLANTS: 1. Hazelton,PA 2. Winter Haven, FL EVIDENCE SUBMITTED Test Atzency Test Identifier Test Name/Report Date Trinity ERD P10870.09.08-RI TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11 P40390.08.12-2 ASTM D 1623 08/07/12 P37590.07.13-1 ASTM D6164 07/02/13 P45270.05.14 TAS 103,TAS 110&ASTM D1623 05/12/14 P46520.10.14 ASTM D1623 10/03/14 P44360.10.14 TAS 103 &TAS 110 10/07/14 P43290.10.14 ASTM D 1970&TAS 110 10/17/14 PLYG-SC10130.06.16-3 TAS 103 &TAS 110 06/27/16 PLYG-10130.06.16-1 ASTM D1970&TAS 110 06/27/16 PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09 Momentum Technologies,Inc. JX20H7A TAS 103/ASTM D4798&G155 04/01/08 RX14E8A TAS 103/ASTM D4798&G155 11/09/09 DX23D8B TAS 103/ASTM D4798&G155 02/18/10 DX23D8A TAS 103/ASTM D4798&G155 02/18/10 LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. JAPPRMIAMI•DADE COUNPTY • BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1.This Notice of Acceptance. 2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 15-0410.04 a+f Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood,non-insulated Deck Description: Min. 19/32"plywood or wood plank System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6"o.c.at a minimum 4"head lap.(for base sheet only) Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus,self-adhered. Surfacing: See General Limitations Below. Deck Type 1: Wood,non-insulated Deck Description: Min. 19/32"plywood or wood plank System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6" o.c.at a minimum 4"head lap.(for base sheet only) Membrane: Elastoflex S6 G,hot asphalt applied Surfacing: See General Limitations Below. Deck Type 1: Wood,non-insulated Deck Description: Min. 19/32"plywood or wood plank System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-adhered. Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6"o.c.at a minimum 4"head lap. (for base sheet only) Ply Sheet: Polystick MTS Plus,self-adhered with minimum 3"horizontal laps and minimum 6"vertical laps. Membrane: Polystick TU Plus,self-adhered. Surfacing: See General Limitations Below. NOA No.: 15-0410.04 ���'t Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 4 of 8 INSTALLATION REQUIREMENTS: 1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-'/Z" and end laps shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the membrane from the center outward in both directions. 5. For ridge applications,center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention to lap areas. 7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a right fit. A second layer of Polystick shall be applied over the underlayment. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry slate roof assemblies. Polystick TU P may be used in all the previous assemblies listed except metal roofing. Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof file systems. Polystick TU Max may be used in non-structural metal roofing and roof tile systems. Elastoflex S6 G may be used in roof file systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck shall be free of irregularities. 5. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times;not to exceed the preceeding maximum time limitations. Exposure Limitations a s MTS IR-Xe Elastoflez TU TU P Tile Pro Dual Pro TU Max MTS Plus S6 G Plus Winter Haven,FL 180 90 180 180 180 180 180 180 180 Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A NOA No.: 15-0410.04 WMI 1 a Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 5 of 8 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically fastened roof tile applications. Polystick Dual Pro is limited to mechanically fastened roof tile applications. Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in Section 9. Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope shall be as follows: (See Table Below) Tile Profile Polystick MTS Elastoflex Polystick TU Plus,TU P, Polystick Polystick S6 G Tile Pro,Dual Pro TU Max MTS Plus Flat Tile Prohibited 4:12 6:12 6:12 5:12 without battens Profiled Tile Prohibited 4:12 6:12 6:12 4:12 without battens The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. When battens are required,they shall be utilized during loading and installation of tiles. 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure—two tiles laid perpendicular to slope followed by a maximum four tile stack parallel to the slope,for a total of 6 tiles—for all underlayments except Polystick MTS which shall be loaded onto battens. ria Roofing Tiles wy , (6 Max Per Stack) ® 12 CL 6 o h t�'�wt Uis pret�r asn�t, 7�Cy1 vS1iOK NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 6 of 8 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe,Polystick Dual Pro, Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance. If Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed,a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1 %"metal disk as required in Miami-Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on the face of membrane,with the above stated nails and/or disks. The head lap membrane is to cover the area being back-nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement, XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between the application of the lap.The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments.Refer to the Polyglass Tile Loading Guidelines. See General Limitations#9 and#10. 6. Battens and/or Counter-battens,as required by the tile manufacturers NOA,must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 61/4'/12",precautions should be taken,such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours. 8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair,followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. II NOA No.: 15-0410.04 Expiration Date: 09/13/21 INEMW Approval Date: 08/11/16 Page 7 of 8 10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request.It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes can be furnished upon request by our Technical Services Department by calling 1 (800)894-4563. 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800)894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association(NBCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 15-0410.04 Expiration Date: 09/13/21 Approval Date: 08/11/16 Page 8 of 8 Office(954)963-2741 �i`O`B rss� 3901 SW 4&Avenue RRYas Wast-Park,,FL 33023 Email: cherrvroofins@att.net FINGw ww.cherryroofs.com State Certified _ _ CCC 1.325485 _...— _.._._.... ...... .... r PROPOSAL SUBMITTED TO: DATE: T PHONE: _ ^EMAIL: paul@alliedmetalslic.com 305 794 6218 I NAME: Paul Moshein I JOB NAME: SAME STREET: 1098 NE 96th St i STREET: 1098 NE 96th St CITY: STATE: ZIP: CITY: j STATE: ZIP: Miami Shores FL 33138 Miami Shores I FL 33138 PROPOSAL FOR TILE RE-ROOF We hereby submit specifications and estimate for: • Remove all present roofing to a smooth workable concrete surface. Remove all debris from premises. • Replace any rotten wood up to 200 linear feet,any excess of 200 linear feet,to be charged at a rate of$4.50 per linear foot and$65 per sheet for plywood. Flea mat- er � r nd d rud adcifEtat woad stsmay"',0"�s�i�� ,�tof rc�t�s�ood°It�ir� il�+e-i amine hiaen � r # 0 tl crrrelr>Et rt�a ciaei €1*s ctved Slope roof only: • Nail and tin cap one layer of 30#felt over entire slope roof. • Install new 3 x 3 inch galvanized eave drip. • Install 26 gauge galvanized metal in all valleys if needed. • Install new caps on chimney • Install galvanized L-flashing where necessary • Install peel and stick tile underlayment over entire slope roof, back nailing all laps with 1%inch R/S roofing nails. • Install tile in a rich bed mortar of foam. • Cherry Roofing is not responsible for reinstallation of gutters. • Owner is responsible to protect interior and exterior furnishings from dust and debris during roofing process. • This roof will be guaranteed for a period of ten(10)years against faulty workmanship and materials. • Down payments or periodical draws will be discussed upon signing of contract. • This contract price includes all taxes and permits. ***All work will,be done as per industry standards*** Amount: $28,550 _ No carpentry work,woodwork,or painting is included in this contract unless mentioned in the specifications.Cherry Roofing shall not be responsible for the damages whether before commencement of or during the sa d work,or after said work,caused by strikes,war,acts of God,sudden rains,storms,wind storms,material shortage,or any event beyond our control.All work to be done or guaranteed shall be set forth in specifications.No promises,verbal or otherwise,will be valid.In the event payment Is not made as stated in specification,all fees incurred in collection,such as attorney fees,court cost,coilections agencies,are to be paid by signer or owner. Any interruption in the work agreed upon in this contract which is not the fault of Cherry Roofing or beyond the control of the same will be billed according to the time and material,lost work done,or attempted to be done, on this roof other than Cherry Roofing,or their agents,relieves the warrantor from any further obligation hereunder.Should any leak occur,within the period of our guarantee,due to defective materials or workmanship supplied and furnished by us,we hereby agree to repair same without charge,upon receipt of the proper notice in writing,by certified mail,providing that the job complained of has been promptly paid in full.This guarantee shall apply to labor and materials only and does not cover damage to personal property which occurs as a result of leakage after roof is installed.We do not guarantee against leakage due to:footwear,improper building or roof deck construction,fire,hall,tempest or hurricanes not to punctures made by fastening or wire fixtures,nor the erection of any hatchway,penthouse,flagpole,pipe or other structure,support or brace,subsequent to completion of our work on your property.We cannot be responsible for sidewalks,lawns,awnings and fences for access to the building.We cannot be responsible for ceiling damage during the process of roofing,condition of solars,gutters,and motor matching with the color tile.This contract coven only that work which is specifically designated herein and does not cover any additional repairs which are found necessaryofter commencement of work This is not transferable unless mentioned in the above specifications Not responsible for screen enclosures. BUYERS RIGHT TO CANCEL You may cancel this agreement by mailing a notice to Cherry Roofing.This notice must be postmarked before midnight on the third business day after signs this agreement.If you cancel this agreement Cherry Roofing may keep all or part of any cash down payment,not to exceed the lessor of 25(Twenty Five)percent of the total contract. Due to the nature of roofing work,we strongly recommend that the following be completed by the.customer prior to our commencing work: 1. Cover furniture with a drop cloth. 2. Remove any lamps,art objects or other breakable items from room. 3. Remove any debris that may have fallen in swimming pool after each phase of roof work. Although we take all due care,CHERRY ROOFING,U.C.cannot be responsible for any dirt or small debris that might fall through sheathing on exposed ceiling type roofs,therefo there may be some clean up(vacuuming, dusting,etc)required of the customer after completion of job. Date Of Acceptance Make All Checks Payable to: Le� re. .. ...-_.__..___-_._-n u Trnvcs W�Ul Olvu,s Cherry Roofing