RF-17-1689 �rmrt arc 7- 1�9
Miami Shores Village _ 7-yB= 00
S.� 10050 N.E.2nd Avenue NE Caj#' T
Miami Shores,FL 33138-0000 ;rMt
'PR VED
a � Phone: (305)795-2204
Expiration: 12/26/2017
ue cam
iss :6129126 p�
Project Address Parcel Number Applicant
1098 NE 96 Street 1132060143460
PAUL AND SUZY MOSHEIM
Miami Shores, FL 33138- Block: Lot:
Owner Information Address Phone Cell
PAUL AND SUZY MOSHEIM 1098 NE 96 ST (305)757-8233
MIAMI SHORES FL 33138-2552
Contractor(s) Phone Cell Phone Valuation: $ 28,550.00
CHERRY ROOFING ENTERPRISES INI (954)963-2741 (954)658-9878
_. __._. _ Total Sq Feet: 3800
Type of Work:Re Roof Available Inspections:
Additional Info:RE-ROOF TILE Inspection Type:
Classification:Residential
Up Lift Report
Scanning:3 Tin Cap
Final Roof
Tile In Progress
Review Roof
Renailing Affidavit
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
Bond Type-Contractors Bond $500.00 Invoice# RF-6-17-64439
CCF $17.40 06/29/2017 Check* 1376 $50.00 $840.16
DBPR Fee $4.88
DCA Fee $4.88 06/29/2017 Check#:1375 $840.16 $0.00
Education Surcharge $5.80 Bond#:3444
Permit Fee-New Roof $325.00
Scanning Fee $9.00
Technology Fee $23.20
Total: $890.16
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zoning. Futh rzn ,I authorize the above-named contractor to do the work stated.
j- a ZBi^'�� June 29,2017
Authorized Signature:Owner / Applicant / Contractor / Agent Date
Building Department Copy
June 29,2017 1
Miami Shores Village RECEIVED
Building Department JUN 2 9 2017
10050 N.E.2nd Avenue,Miami Shores,Florida 33138
Tel:(305)795-2204 Fax:(305)756-8972 Q"
INSPECTION LINE PHONE NUMBER:(305)762-4949
FBC 201`1
BUILDING Master Permit No. 1 —4 Sol
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC EZ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: %OR% 111t- IA6- !�)r
City: Miami Shores County Miami Dade Zia:
Folio/Parcel#: kk - �`l.®�.-��19 — & U12 Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder):�t7.'j M-041 '\rn Phone#: 05 -}HCl.
Address:0Q)(DL6 SLA- SV
City: 4axyxk S\11Vz)M1b1 State: �� Zip:
Tenant/Lessee Name: Phone#: '�"S%st
Email: n
CONTRACTOR:Company Name: Phone#:R'54
Address:
City: "Qt-,V State: V- . Zip:
Qualifier Name: c Phone#:
State Certification or Registration Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State Zip:
Value of Work for this Permit:$ VG- . 5Q-cv ✓ Square/Linear Footage of Work: ,two
Type of Work: ❑ Addit ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work: k
Specify color of color thru tile:
Submittal Fee$ Permit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$
(Revised02/24/2014)
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
'WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first insp ection which ac rs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will ni it be approved at a reinspection fee will be charged.
b� —
Signature Signature
OWNER or AGENT ONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of TWVZ1 .20 1. •by Z'I— day of 3CA N(:;;7 .20 IT by
,?AtAL- mos"&"A ,who is personally known to mQ,�-$ S ck�c RI-q ,who is personally known to
me or who has produced D L— as me or who has produced 0 (-- as
identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign:
Print:45'rAnixrit7 . Print: g�/rir
s;r C�oie
Seal: Seal:
;;•�"" ;; JENNIFER D COLE , : JENNIFER D COLE
'i MY COMMISSION#G 49278 MY COMMISSION#GG049278
MIN" r
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
Miami shores Village
... p.,M
Building Department
~ ` 10050 N.E.2nd Avenue
oRi Miami Shares, Florida 33138
Tel. (305) 795,2204
Fut: (305) 756.8972
WLNE S'S AFFIDAVIT OF UEMPTION
ROOF TO WALL CONNECTION HURRICANE"MITIGATION RETROFIT FOR EXISTING SITE.
BUILT SINGLE FAMILY,RESIDENTIAL STRUCTURES
PER ANT TO SECTION$9.844 F.S.
To. Miami Shores Village Building Department Date. --23-'ZOl`�—
10050 NE 2nd Ave
Miami.Shores, FI 33138
Re; Owners Name: ?C�� rk�s'lacn
Property Address.�b�-i� ►°�L� a �
Roofing Permit Number:
Dear Building Official:
I pw."�A mncz�m cerft'fy that l:am not required-to retrofit the roof to wail connections of my
building because:
gThe just valuation for the structure for purpose of ad valorem taxation is less than$300.,000.00. Please attach proof of ad
valorem taxation.
J0 The building was constructed in compllance...with the provisiotns of the Florida Building Code(FBC)orwith tho provisions
of 994 edition i if the A FloridaBuilding Cede{1994 SFBC)
Signature Print Dame
State of Florida
County of Dade
The undersigned, being the first duly sworn,deposes and says that he/she is the-owner for the above property mentioned,
Sworn to and subscribed before me this -day of :S iW
,.,00'Y� JENNIFER D COLE
Notary Public, Sate of Florida at large . .
EXPIRES November 21,2020
• When the justvstuation offhe shucriue for 'utp IM, Is-equal fo ormorethan 0. �andthe buftrg was not const ctod wM F.BC nora 1994
S>BC.The you.must Rrovide a beUtl3ng app>sa a nerf contractor for tha Rwf to Wall connection Hurricane tkk 6n
Revised on 50)2009
Prope Search Application-Miami-Dade County Page 1 of 1
011FICE
OF
Summary Report
Generated On:6/29/2017
l HU
Property Information
Folio: 11-3206-014-3460 �T� 511
t F
Property Address: 1098 NE 96 ST
Miami Shores,FL 33138-2552
Owner PAUL MOSHELM&W SUZY
1098 NE 96 ST
Mailing Address , = 42
MIAMI SHORES,FL 33138-255241x
PA Primary Zone 1400 SGL FAMILY-3001-3250 SQ $ f
0101 RESIDENTIAL-SINGLE
Primary Land Use e
FAMILY:1 UNIT
Beds/Baths!Half 4/3/0
r} .F-�•, � '4
j r
Floors 2
Living Units 1 y
Actual Area Sq.Ft El
.. .._ y.
Living Area Sq.Ft
Adjusted Area 3,607 Sq.Ft
Taxable Value Information
Lot Size 18,961.8 Sq.Ft
2017 2016 2015
Year Built 1925
County
Assessment Information Exemption Value $50,000 $50,000 $50,000
Year 2017 2016 2015 Taxable Value 1 $363,619 $355,112 $352,296
Land Value $682,294 $701,630 $578,707 School Board
Building Value $258,803 $260,735 $262,6671Exemption Value $25,000 $25,000 $25,000
XF Value $41,389 $41,756 $29,394 Taxable Value $388,619 $380,112 $377,296
Market Value $982,486 $1,004,121 $87 0 7681 City
Assessed Value $413,619 $405,112 $402,296 Exemption Value $50,000 $50,000 $50,000
Taxable Value $363,619 $355,112 $352,296
Benefits Information Regional
Benefit Type 2017 2016 2015 Exemption Value $50,000 $50,000 $50,000
Save Our Homes Assessment Taxable Value $363,619 $355,112 $352,296
Cap Reduction $568,867 $599,009 $468,472
Homestead Exemption $25,000 $25,000 $25,000 Sales Information
Second Exemption $25,000 $25,000 $25,000 Previous Sale Price OR Book-Page Qualification Description
Homestead 06/01/1996 $300,000 17248-1353 Sales which are qualified
Note:Not all benefits are applicable to all Taxable Values(i.e.County, 05/01/1984 $240,000 12135-1327 Sales which are qualified
School Board,City,Regional). 04/01/1978 $125,000 09998-1667 1 Sales which are qualified
Short Legal Description
MIAMI SHORES SEC 3 PB 10-37
LOT 1 BLK 81
LOT SIZE IRREGULAR
OR 17248-1353 0696 1
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser
and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at hftp://www.miamidade.gov/info/disclaimer.asp
Version:
http://www.miamidade.gov/propertysearch/ 6/29/2017
Ty
SECTION 1024 U PY
mGH vELOCITY`HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOk ROOFING
CO}NSIDERATiONS
1524.1 Scope,As:'it pertains to the section,it is the responsibility of roofing contractor to provide the owner with
the required roofing permits and to explain to the owner the content of the section.The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system Installations.Additionally;the
following items should be addressed as .part of"ttte.agreement between the owner ant the contractor.The owner's
initial in the designated space indleates that the item has been explained.
2. Renailing decks:When replacing roofing,the existing wood roof deck.may have to
be renailed in accordance with the current provisions of Section 84403.(The-roof dear is usually
concealed`prior to removing the existing roof system).
4 f t_4 !Exposed Ceiling.Exposed,open beam ceilings are where the underside of the roof decking
can be viewed from below.The owner may wish to.maintain;#tie architectural appearance;therefore,
roofing nail penetration of the underside of the decking ruby not:be acceptable.This provides the option of
maintaining the appearance.
6. U Ovat#low scuppers(wall outlets);It It required that rainwater flows off so that the roof is
not overloaded from.a buildup of water.Pedmetertedge wail or other roof extension may block this
discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow
scuppers in accordance:with the requirements of Sections 84402,84403 and 114413.
.
�L d I �0
wn nts Signature, Date: Contractor S' tore Dafe
1®q% NC 'Diu_ G - _
Properly:Address Permit Number
Revised on 7/9/2009 LD;07/01/2015;
Florida Building Code Edition 2014 ,
High Velocity Hurricane Zone- Uniform Roofing Application For
AM
9
r I
■■■■■■■■■■■■■■■■■■■ ■_��■� ���■■■■■■■■■■■■■soon■■
■■nNNNNN■NNW■■■■f �NNn■■■n�■nNn �Nn■■■INNN■■■■■■■■
I
■■■■■■■■■■■■■■�■■■■■NSI■■■■■■■■■■■■■■■■■�■■■NINE
■■■■■■■■■Nn■'■N■►NnnNnnss■■■■■■■■■■■■I■r■o■gin■■■
■■s■■■N■■■■■��■■■� sno■■■■■o■■■■s■■■■nlnn■■�s■■n
■■■■■■■■■■■ors■■■■s�■■■■soEi�rss■��■�■■■■■■ :.:. .7
s■■■■■■■■■■■■■■■■ns■jn�■N■■■fn_o n--_-WAN. .s
..,..rrs��•t1iCEaiW31-'L��..��
n������N■N��nNNNn■N■aNn■■n■n����sQ■�����en_nN��_iN■�-WWII■
t Florida Building Code Edition 2014
High Velocity Hurricane Zone• Uniform Roofing Application Form
Section D,(Steep Sloped Roof System)
Roof System Manufacturer: '%A Q--kov'�z
Product Approval Number:
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
131:-VO, 132• •-b%' � P3: -►OO•�-
Maximum Design Pressure
Product Approval Specific System:
Method of Tile Attachment: V� ►Q-^ C��CIx! ��� c�-��arn
Steep Sloped System Descri tp ion
Deck Type:
Roof Slope: Type Underlayment:
12
Insulation:
Fire Barrier
Fastener Type&Spacing: 119Pf-0%4C- cA-P IV Q a5 �-
Ridge Ventilation? M � 2 o A (7-UW6 , Af.
Adhesive Type:
f�f �C
Type Cap Sheet:
Roof Covering: _,
r► L .
Mean Roof Height: 1;�
Type&Size Drips
Edge:
Florida Building Code 5th Edition 2014
HIGH VELOCITY HURRICANE ZONE UNIFORM ROOFING PERMIT APPLICATION
SECTION E (Tile Calculations)
For moment based tile systems,chose either Method for 2. Compare the values for Mr with the values from Mf. If
the Mf values are greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is
acceptable.
Method 1 "Moment Based Tile Calculations Per RAS 127"
PI:3,31°t x X ®•--7XDA = 11.1691 ) -Mg:` -20 =Mrl: 0 1 NOA Mf: 7
Pz: x.%
�,Q% =7Q•4CK 1 )-Mg: =Mr1:1 . 1 NOA M f:
P3: 100 `� x� ®�� 1 ='30.310 -)-Mg: :a.d a =Mrl: 23.31 aV NOA Mf: 3� •"�-
Method 2"Simplified Tile Calculation Per Table Below" 3&
Required Moment of Resistance(M,)From Table Below: 7s 7- NOA Mf:
Mr Required Moment Resistance*
Mean Roof Height
Roof Slope 15 20' 25' 30' 40'
2:12 .4 36.5 38.2 39.7 42.2
:12. 34.4 36.0 37.4 39.8
:12 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 26.4 28.0 29.4 1 30.5 32.4
7:12 24.4 25.9 27.1 28.2 30.0
*This table must be used in conjunction with a list of moment based tile systems endorsed by the Broward County
Board of Rules and Appeals.
For uplift based tile systems use Method 3. Compare the values for F'with the values for Fr.If the F'values are
greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable.
Method 3"Uplift Based Tile Calculations Per RAS 127"
(Pl: x 1: = x w: -w: x cos 0: =Fri: NOA F':
(PZ: x 1: = x w: -w: x Cos 0: =Frz NOA F':
(P3: x 1: =-xw: -w: x cos 0: =Fr3 NOA F':
Where to Obtain Information
Description Symbol Where to Find
Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineering analysis
prepared by a P.E.based on ASCE 7
Mean Roof Height H Job Site
Roof Slope 0 Job Site
Aerodynamic Multiplier x NOA
Restoring Moment due to Gravity M NOA
Attachment Resistance Mf NOA
Required Moment Resistance Mr Calculated
Minimum Attachment Resistance F' NOA
Required Uplift Resistance Fr Calculated
Average Tile Weight W NOA
Tile Dimensions 1=length NOA
w=width
All calculations must be submitted to the Building Official at the time of permit application.
A �
RECEIVE®
I
I JUN 2 91017
MIAMI-DARE COUNTY
RODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Willot 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) adade.eov/economy
Boral Roofing,LLC
7575 Irvine Center Drive,Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barcelona 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No.12-0222.02 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0711.01
ruar�lnaoeeolnvrr Expiration Date: 04/26/22
-1 PPROVEDI Approval Date: 10/27/16
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Barcelona 900 Concrete Roof Tile,as manufactured Boral Roofing LLC
in Lake Wales,FL and described this Notice of Acceptance. For locations where the pressure requirements, as
determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations
shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Barcelona 900 Length= 17" TAS 112 High profile,interlocking,one-piece,'S'shaped,
Width= 13" Type—1 a high-pressure extruded concrete roof tile
1/Z"thick equipped with three nail holes. For direct deck
or battened nail-on,mechanically fastened,
mortar set or adhesive set applications.
Trim Pieces Length:varies TAS-112 Accessory trim,boosted Barcelona,concrete
Width:varies roof pieces for use at hips,rakes,ridges and
varying thickness valley terminations manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
2.1.1. Lake Wales,FL
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102&TAS 102(A)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix H TAS 108(Nail-On)
Redland Technologies P0402 Withdrawal Resistance Sept. 1993
Testing of screw vs. smooth
shank nails
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108(Nail-On)
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108(Mortar Set)
NOA No.: 16-0711.01
IAMFDADE COUNTY Expiration Date: 04/26/22
�� ...�
Approval Date: 10/27/16
Page 2 of 7
i k
Professional Service Industries,Inc. IC-1320-94 Physical Properties Feb. 1995
TAS 112
The Center for Applied Engineering,Inc. 25-7688-3 TAS 101 (Adhesive Set) June 1996
25-7688-10 TAS 101 (Mortar Set) July 1996
The Center for Applied Engineering,Inc. 25-7688-5 Static Uplift Testing June 1996
TAS 102
(3"Headlap,Nails,Direct
Deck,New Construction)
The Center for Applied Engineering,Inc. 25-7688-4 Static Uplift Testing June 1996
TAS 102
(4"Headlap,Nails,Clips)
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services 520191-2-1 TAS 101 March 1999
Walker Engineering,Inc. Calculations Aerodynamic Multiplier 09/01/16
Walker Engineering,Inc. Evaluation Restoring Moments Due to 09/01/16
Calculations Gravity
American Test Lab of South Florida RT0617.03-16 TAS 112 06/29/16
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may
required,refer to applicable building code.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112,appendix `A'. Such testing shall be submitted to the Department of Regulatory
and Economic Development —Product Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
NOA No.: 16-1711.01
tinnuecounerY Expiration Date: 04/26/22
_I_APPROVEDI
Approval Date: 10/27/16
Page 3 of 7
e
4. INSTALLATION
4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing
Application Standard RAS 118,RAS 119,and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight W(Ibf) Length-I (ft) Width-w(ft)
Barcelona 900 11.5 1.417 1.08
Table 2: Aerodynamic Multipliers -A(ft)
Tile Profile k(ft) A (ft3)
Batten Application Direct Deck Application
Barcelona 900 0.286 0.301
Table 3: Restoring Moments due to Gravity-M9 (ft-lbf)
Tile 2"•12" 3"•12" 4"•12" 51'•12" 6"•12" 7"•12" or
Profile greater
Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
900 Deck Deck Deck Deck Deck Deck
6.19 7.07 6.19 7.00 6.19 6.90 6.06 6.76 5.92 6.60 5.76 6.42
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Mechanically Attached Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4
1-10d Smooth or Screw Shank 5.1 6.8 2.8
Nail
2-10d Smooth or Screw Shank 6.9 9.2 7.3
Nails
1 #8 Screw 20.7 20.7 18.1
2#8 Screw 43.2 43.2 29.8
1-10d Smooth or Screw Shank 23.1 23.1 19.0
Nail Field Clip)
1-10d Smooth or Screw Shank 29.3 29.3 24.0
Nail Eave Clip)
2-10d Smooth or Screw Shank 27.6 27.6 38.6
Nails Field Clip)
2-10d Smooth or Screw Shank 38.1 38.1 41.8
Nails Eave Clip)
NOA No.: 16-0711.01
htu MMADe eouNTY Expiration Date: 04/26/22
,..
Approval Date: 10/27/16
Page 4 of 7
Table 5: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mechanically Attached Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Barcelona 900 2-10d Ring Shank Nails' 33.1 48.1 45.2
1 Installation with a 4"tile headlap and fasteners are located a min.of 2'/z"from head of tile.
Table 6: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Paddy Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Adhesive' 29.32
1 See manufactures component approval for installation requirements.
2 TILE BONDTm Roof Tile Adhesive;Average weight per paddy 10.7 grams.
ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160;Average weight per paddy 8 grams.
Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Single Paddy Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 ICP Adhesives Pol set AH-160 66.53
ICP Adhesives Pol set AH-160 38.74
3 Large paddy placement of 63 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Polyset AH-160.
4 Medium paddy placement of 24 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Pol et AH-160.
Table 8: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Mortar Set Systems
Tile Tile Attachment
Profile Application Resistance
Barcelona 900 Mortar Sets 24.5
6 Seespecific mortar manufacturers Notice of Acceptance
NOA No.: 16-0711.01
Caaane coufvnr Expiration Date: 04/26/22
Approval Date: 10/27/16
Page 5 of 7
a 1
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed
below,or following statement: "Miami-Dade County Product Control Approved".
LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
NOA No.: 16-0711.01
Mu►Mi Wane cotmnr Expiration Date: 04/26/22
J A P P ROVEDi Approval Date: 10/27/16
Page 6 of 7
PROFILE DRAWING
NAIL' S
t3VEFYl..
Awi,
�i7 A
3
UNQEIROCK ' 'J
BARCELONA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 16-0711.01
rE coutvrir Expiration Date: 04/26/22
Approval Date: 10/27/16
Page 7 of 7
MIAMI-DADS COUNTY
M PRODUCT CONTROL SECTION
in 11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy
ICP Adhesives and Sealants,Inc.
12505 NW 441 Street
Coral Springs,FL.33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polysee AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
raar�aw4uE ccwr�ertr Expiration Date: 05/10/22
Approval Date:04/27/17
Page 1 of 11
IL
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described
in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable
building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP
Adhesives Polyset'AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive
Polyset'AH-160
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPacV N/A Dispensing Equipment
30& 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset'AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.61bs./fft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft'
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
+6.0%Volume Change @158°F., 100%Humidity,2
weeks
Closed Cell Content ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
ruarLtine 9)*NCO Expiration Date: 05/10/22
' Approval Date:04/27/17
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[1] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp.Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset'AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
M1,4Mt�apeCou�rrr Expiration Date: 05/10/22
_]APPROVED Approval Date:04/27/17
Page 3 of 11
A S
INSTALLATION:
1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset, AH-160.
2. ICP Adhesives Polyset,AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset®AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and
Sealants,Inc. ICP Adhesives and Sealants,Inc.shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the"A"component and the"B"component shall be maintained between
1.0-1.15 (A): 1.0(B).
6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP
Adhesives ProPack®30& 100 dispensing equipment only.
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset®AH-160 has been dispensed.
9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details'herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
t+�AMti�d1DECOUMY Expiration Date: 05/10/22
JAPPROVED
Approval Date:04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq.inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq.inches at 12 grams per paddy
head of tile 9-11 sq.inches at
overlap
Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq.inches each
bead
Two Piece Barrel(Pan Tile) Two Piece j 65-70 sq.inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
BUILDING PERMIT REQummENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
NIIAMhQADECOUNrIY Expiration Date: 05/10/22
APPROVED
Approval Date:04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL# 1
1 Flat/Low Profile Tile
p ." 1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown,
� under the strengthening rib closest to the overlock
Ilam of the tile being set.
2. Continue in same manner.Insure approximately 17
f R (109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
To
Medium Profile/ Double Pan Tile
�t 1. Starting at the eave course,apply a minimum 2"
_.; (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
" overlock of the tile being set.
84
s 2. Continue in same manner.Insure approximately 17
(109.7 cm)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
Is
High Profile/Single Pan Tile
® 1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
sit under the pan portion of the tile closest to the
overlock of the tile being set.
e
F 2. Continue in same manner.Insure approximately 17
(109.7 cm)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
Weaubde
dom
NOA No.: 17-0322.03
raa�aan�oEcoutvtY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL#2
Rawfamb) Flat/Low Profile Tile
1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlook of
the file being set.Insure approximately 17(109.7 cm2)
23 (148.4 cm2)square inch adhesive contact with the
R.Kank Gran"
underside of the tile.
EM
° 2. At the second course,apply a minimum 2"(50.8mm)
air x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the file
being set.
3. Continue in same manner.Insure approximately 10"
(64.5 cm2)- 12(77.4 cm)square inch adhesive
contact with the underside of the rile.
Medium Profile/Double Pan Tile
a 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 nun)foam paddy
onto the underlayment positioned as shown under the
pan portion of the file closest to the overlock of the
tile being set.Insure approximately 17(109.7 cm)—
7 23 (148.4 cm2)square inch adhesive contact with the
w
underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
tom. x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner.Insure approximately 12"
(77.4 cm2)- 14(90.3 cm2)square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
MIAMtiQADE COUNTY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
High Profile/Single Pan Tile
1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
the being set.Insure approximately 17(109.7 cm2)—
"" "�� 23 (148.4 cm)square inch adhesive contact with the
underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
1 x 7"(177.8 mm)x 1"(25.4 nun)foam paddy onto the
' underlayment positioned as shown under the pan
t � '2b dwom portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner.Insure approximately 17"
(109.7 cm2)- 19(122.6 cm)square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
MIAMFW►DECOUMY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 8 of 11
r - �
ADHESIVE PLACEMENT DETAIL#3
1. On the eave course only,apply a minimum 2" (50.8
mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy
p onto the underlayment positioned as shown,under
the strengthening rib for flat tile or under the pan
portion of the the for low or high profile the closest
to the overlock of the tile being set.Leave
=4 approximately 4"(10 1.6 mm)up from the eave
edge free of foam to prevent the expanded adhesive
� �- from blocking the weep holes. Insure
a ,:z approximately 17-23 int(109.7-148.4 cm2)of
adhesive contact with the underside of the tile
2. Apply a 4"(101.6 mm)x 4" (101.6 mm)x 1" (25.4
mm)foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile,or under the
pan portion of the tile,closest to the underlock for
t the second course file to be installed. Insure
approximately 8-9 int(51.6-58.1 cm2)of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
•�"' `$a4hL ..
o ate. ,
R%KftMPWftTft
NOA No.: 17-0322.03
WDAUEcoExpiration Date: 05/10/22
Approval Date:04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL#3 (CONTINUED)
Iert0e
tohm3. Also apply a 2"(50.8 mm)x 4"(101.6 mm)x3/4"
Alftouftemfto (19 mm)paddy on top of the eave course tile
enma� surface as shown,on top of the strengthening rib
° for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9(58.1 cmZ)- 11 (71cm2)square inch adhesive
contact with the underside of the tile at the overlap
294 and 7(45.2 cm)-9(58.1 cmZ)square inch
adhesive contact with the underside of the tile at
the head of the tile.Continue in same manner.
r
hL r�e•s�:
Ddpedp
Hlopnmm
NOA No.: 17-0322.03
MuuraaouaoE COUNTY Expiration Date: 05/10/22
Approval Date:04/27/17
Page 10 of 11
Y
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel(Cap and Pan)Tile
1. Starting at the eave course,apply a minimum 2"
ll""OonouoadhesWetoaddt%vOSW70sq.1a, SweppWhappIcaSm (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
�► a� ►tea
z1 ,► :aaan��wa.; paddy onto the underlayment positioned as
� ,;tna.tstda••teotc •re0e. shown under two adjacent pan tiles. Support eave
ns�u•.emto.
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2)—70(451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
t t: 3. Turn covers upside down exposing the underside
w of the tile.Apply a minimum 1"(25.4 mm)x 10"
cad
(254 mm)bead of adhesive directly on the inner
ttt�ii ,atereawtt�.xeae.iosem»d edge of each side of the cover tile.Leave
approximately 3/4"(19 mm)to 1"(25.4 mm)
.wo.Ple Barrel-High PmfileTflo from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course.Insure a minimum of
20(129 cm2)-25 (161.3 cm2)square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive.Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required,2"(50.8
mm)x 4"(101.6 mm)nailers or the tie wire
system using galvanized,stainless steel,or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-1322.03
Mwe� ►uE counmr Expiration Date: 05/10/22
JAPPROVED Approval Date:04/27/17
Page 11 of 11
MIAMM
MIAMI-DARE COUNTY
MEW PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www•ndamidade.gov/economy
Polyglass USA Inc.
1111 W.Newport Center Drive
Deerfield Beach,FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.14-0717.08 and consists of pages 1 through 8.
The submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category Roofing
Sub-Category: Underlayment
Material: SBS ,APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick IR-Xe 65'x 313-3/8,, ASTM D 1970 A fine granular/sand top surface self-adhering,APP
Manufacturing Or 65'x 3' polymer modified,fiberglass reinforced,bituminous
Location#1  60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice&rain shield.
Polystick Dual Pro 61'x 3'3 3/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location#2 metal roofing and roof tile underlayment.
Polystick Tile Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Location#2 roofing and roof tile underlayment.
Polystick TU Max 65'8"x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhering,polyester reinforced
Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location#1  underlayment.
Polystick TU P 32'10"x 313/8' TAS 103 and A rubberized asphalt waterproofing membrane,glass-
Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced,with a granular surface
Location#2 designed for use as a tile roof underlayment.
Polystick TU Plus 65'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
(Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Manufacturing roofing and roof tile underlayment.
Location#I 
Polystick MTS 65'8"x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Polystick MTS Plus 65'8"x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Elastoflex S6 G 32'10"x 313/8' TAS 103 and Polyester reinforced,SBS modified bitumen membrane
Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For
Location#2 use in roof tile underlayment systems.
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 2 of 8
q 1 �
MANUFACTURING PLANTS:
1. Hazelton,PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Atzency Test Identifier Test Name/Report Date
Trinity ERD P10870.09.08-RI TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11
P40390.08.12-2 ASTM D 1623 08/07/12
P37590.07.13-1 ASTM D6164 07/02/13
P45270.05.14 TAS 103,TAS 110&ASTM D1623 05/12/14
P46520.10.14 ASTM D1623 10/03/14
P44360.10.14 TAS 103 &TAS 110 10/07/14
P43290.10.14 ASTM D 1970&TAS 110 10/17/14
PLYG-SC10130.06.16-3 TAS 103 &TAS 110 06/27/16
PLYG-10130.06.16-1 ASTM D1970&TAS 110 06/27/16
PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09
Momentum Technologies,Inc. JX20H7A TAS 103/ASTM D4798&G155 04/01/08
RX14E8A TAS 103/ASTM D4798&G155 11/09/09
DX23D8B TAS 103/ASTM D4798&G155 02/18/10
DX23D8A TAS 103/ASTM D4798&G155 02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city
and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
JAPPRMIAMI•DADE COUNPTY
•
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1.This Notice of Acceptance.
2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 15-0410.04
a+f Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6"o.c.at a minimum 4"head lap.(for
base sheet only)
Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick
TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus,self-adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12"grid,6" o.c.at a minimum 4"head lap.(for
base sheet only)
Membrane: Elastoflex S6 G,hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6"o.c.at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus,self-adhered with minimum 3"horizontal laps and minimum 6"vertical
laps.
Membrane: Polystick TU Plus,self-adhered.
Surfacing: See General Limitations Below.
NOA No.: 15-0410.04
���'t Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and
sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-'/Z" and end laps
shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of
the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building
code.
4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications,center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention
to lap areas.
7. Flash vent pipes,stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a right fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof file systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof file systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times;not to exceed the preceeding maximum time limitations.
Exposure Limitations a s
MTS IR-Xe Elastoflez TU TU P Tile Pro Dual Pro TU Max MTS Plus
S6 G Plus
Winter Haven,FL 180 90 180 180 180 180 180 180 180
Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A
NOA No.: 15-0410.04
WMI
1 a Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 5 of 8
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope
shall be as follows: (See Table Below)
Tile Profile Polystick MTS Elastoflex Polystick TU Plus,TU P, Polystick Polystick
S6 G Tile Pro,Dual Pro TU Max MTS Plus
Flat Tile Prohibited 4:12 6:12 6:12 5:12
without battens
Profiled Tile Prohibited 4:12 6:12 6:12 4:12
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required,they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment.Refer to Polyglass' Tile loading detail below for loading procedure—two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope,for a total of 6 tiles—for
all underlayments except Polystick MTS which shall be loaded onto battens.
ria
Roofing Tiles
wy ,
(6 Max Per Stack)
®
12
CL 6
o
h t�'�wt Uis pret�r asn�t,
7�Cy1 vS1iOK
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 6 of 8
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU
Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe,Polystick Dual Pro,
Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick
TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed,a request may be made to the
Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1 %"metal disk as
required in Miami-Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on
the face of membrane,with the above stated nails and/or disks. The head lap membrane is to cover the area being
back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps,shall have a 6"wide,uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between
the application of the lap.The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments.Refer to the Polyglass Tile
Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens,as required by the tile manufacturers NOA,must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 61/4'/12",precautions should be
taken,such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,XtraFlex 50 Premium Modified
Wet/Dry Cement,Polyglass PG500 MB Flashing Cement to the area in need of repair,followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair.Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so
that water will run parallel to or over the top of all laps of the patch.
II NOA No.: 15-0410.04
Expiration Date: 09/13/21
INEMW Approval Date: 08/11/16
Page 7 of 8
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request.It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800)894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800)894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association(NBCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
Page 8 of 8
Office(954)963-2741 �i`O`B rss�
3901 SW 4&Avenue
RRYas
Wast-Park,,FL 33023
Email: cherrvroofins@att.net
FINGw
ww.cherryroofs.com
State Certified
_ _ CCC 1.325485
_...— _.._._.... ...... ....
r PROPOSAL SUBMITTED TO: DATE: T PHONE: _
^EMAIL: paul@alliedmetalslic.com 305 794 6218
I
NAME: Paul Moshein I JOB NAME: SAME
STREET: 1098 NE 96th St i STREET: 1098 NE 96th St
CITY: STATE: ZIP: CITY: j STATE: ZIP:
Miami Shores FL 33138 Miami Shores I FL 33138
PROPOSAL FOR TILE RE-ROOF
We hereby submit specifications and estimate for:
• Remove all present roofing to a smooth workable concrete surface. Remove all debris from premises.
• Replace any rotten wood up to 200 linear feet,any excess of 200 linear feet,to be charged at a rate of$4.50 per
linear foot and$65 per sheet for plywood.
Flea mat- er � r nd d rud adcifEtat woad stsmay"',0"�s�i�� ,�tof rc�t�s�ood°It�ir� il�+e-i
amine hiaen � r # 0 tl crrrelr>Et rt�a ciaei €1*s ctved
Slope roof only:
• Nail and tin cap one layer of 30#felt over entire slope roof.
• Install new 3 x 3 inch galvanized eave drip.
• Install 26 gauge galvanized metal in all valleys if needed.
• Install new caps on chimney
• Install galvanized L-flashing where necessary
• Install peel and stick tile underlayment over entire slope roof, back nailing all laps with 1%inch R/S roofing nails.
• Install tile in a rich bed mortar of foam.
• Cherry Roofing is not responsible for reinstallation of gutters.
• Owner is responsible to protect interior and exterior furnishings from dust and debris during roofing process.
• This roof will be guaranteed for a period of ten(10)years against faulty workmanship and materials.
• Down payments or periodical draws will be discussed upon signing of contract.
• This contract price includes all taxes and permits.
***All work will,be done as per industry standards***
Amount:
$28,550 _
No carpentry work,woodwork,or painting is included in this contract unless mentioned in the specifications.Cherry Roofing shall not be responsible for the damages whether before commencement of or during the sa d
work,or after said work,caused by strikes,war,acts of God,sudden rains,storms,wind storms,material shortage,or any event beyond our control.All work to be done or guaranteed shall be set forth in specifications.No
promises,verbal or otherwise,will be valid.In the event payment Is not made as stated in specification,all fees incurred in collection,such as attorney fees,court cost,coilections agencies,are to be paid by signer or owner.
Any interruption in the work agreed upon in this contract which is not the fault of Cherry Roofing or beyond the control of the same will be billed according to the time and material,lost work done,or attempted to be done,
on this roof other than Cherry Roofing,or their agents,relieves the warrantor from any further obligation hereunder.Should any leak occur,within the period of our guarantee,due to defective materials or workmanship
supplied and furnished by us,we hereby agree to repair same without charge,upon receipt of the proper notice in writing,by certified mail,providing that the job complained of has been promptly paid in full.This guarantee
shall apply to labor and materials only and does not cover damage to personal property which occurs as a result of leakage after roof is installed.We do not guarantee against leakage due to:footwear,improper building or
roof deck construction,fire,hall,tempest or hurricanes not to punctures made by fastening or wire fixtures,nor the erection of any hatchway,penthouse,flagpole,pipe or other structure,support or brace,subsequent to
completion of our work on your property.We cannot be responsible for sidewalks,lawns,awnings and fences for access to the building.We cannot be responsible for ceiling damage during the process of roofing,condition
of solars,gutters,and motor matching with the color tile.This contract coven only that work which is specifically designated herein and does not cover any additional repairs which are found necessaryofter commencement
of work This is not transferable unless mentioned in the above specifications Not responsible for screen enclosures.
BUYERS RIGHT TO CANCEL
You may cancel this agreement by mailing a notice to Cherry Roofing.This notice must be postmarked before midnight on the third business day after signs this agreement.If you cancel this agreement Cherry Roofing may
keep all or part of any cash down payment,not to exceed the lessor of 25(Twenty Five)percent of the total contract.
Due to the nature of roofing work,we strongly recommend that the following be completed by the.customer prior to our commencing work:
1. Cover furniture with a drop cloth.
2. Remove any lamps,art objects or other breakable items from room.
3. Remove any debris that may have fallen in swimming pool after each phase of roof work.
Although we take all due care,CHERRY ROOFING,U.C.cannot be responsible for any dirt or small debris that might fall through sheathing on exposed ceiling type roofs,therefo there may be some clean up(vacuuming,
dusting,etc)required of the customer after completion of job.
Date Of Acceptance Make All Checks Payable to: Le� re. .. ...-_.__..___-_._-n u
Trnvcs W�Ul Olvu,s Cherry Roofing