Loading...
FW-17-1130 7-'I 130 ' 4 4" ° Miami Shores Village relit ��>��nNa��! 10050 N.E.2nd Avenue NE *{J i.N2a�/ i.1�Ti lr [# a tCl• Miami Shores,FL 33138-0000 hreN �O Phone: (305)795-2204 °"Petmit�':Status: �tonwA ate: ( /'11t?'!? Expiration: 11/07/2017 Issue tp. Project Address Parcel Number Applicant 10401 NE 4 Avenue 1122310150100 Miami Shores, FL 33138-2012 Block: Lot: JACK&KATHLEEN SITES Owner Information Address Phone Cell JACK&KATHLEEN SITES 10401 NE 4 Avenue MIAMI SHORES FL 33138-2012 10401 NE 4 Avenue MIAMI SHORES FL 33138-2012 Contractor(s) Phone Cell Phone Valuation: $ 4,500.00 ALL FENCING AND REPAIR (954)306-3477 Total Sq Feet: 102 Approved: Available Inspections: Comments: Inspection Type: Date Approved: Final Date Denied: Foundation Type of Construction:Other Additional Info:INSTALLATION OF ALUMINUM FEN( Review Planning Classification:Residential Scanning:3 Review Building Review Structural Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $3.00 Invoice# FW-4-17-63797 DBPR Fee $2.00 DCA Fee $2.00 04/25/2017 Check#:5898 $50.00 $153.00 Education Surcharge $1.00 05/11/2017 Check#:5948 $ 153.00 $0.00 Permit Fee-Wire&Wood $102.00 Plan Review Fee(Engineer) $80.00 Scanning Fee $9.00 Technology Fee $4.00 Total: $203.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: Ice ata the forego/ formation is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. hermor auth a above-named contractor to do the work stated. May 11, 2017 Autho zed S' ure:Owner / Applicant / Contractor / Agent Date Building Department Copy May 11,2017 1 yam, s � 3<r�7 v� Miami Shores Village Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 ���✓" -`_ Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 BUILDING Master Permit No. � PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS CHANGE OF ❑CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 10�® t)� & y c%„ City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: —., 3 f ®�SA—(���. Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFFE: p�/Q OWNER:Name(Fee Simple Titleholder): C. � Phone#:� — 02-z /(� Address: 'j i City: lH 1 s` A bcrt-� State: Zip: � u Tenant/Lessee Name: nn Phone#: Email: Lif`C�9 C( l/ C0 e CONTRACTOR:Company Name: i��l ( vtGf 1 Q vL� �� r Phone#:J�36 Y1? Address: /®®cicf City: C-::'�-e-(.A-rlde— State: �� Zip: Qualifier Name: Cc)r� �// Phone#: State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$_ Square/Linear Footage of Work: Type of Work: ❑ Addition � E-1 Alteration ❑ New E:1Repair/Replace ❑ Demolition _ Description of Work:�,l��l`��t 1' �� �_ a e�/4��c Q-k Specify color of color thru tile: I Submittal Fee$�,-, C� Permit Fee$ ! CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$�� ` CQ1 Bond$ TOTAL FEE NOW DUE$ !SS a (RevisedO2/24/2014) A Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS, HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Q Signature �� OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 07 �� day of 20 by rday of by who is personally known to is personally know' to me or who has produced (if�e't'—Se 6 as me or who has produced as id l o identificatiw-- Nary Public State of Florida { Notary Public State of Florida N LlQeanette C Siegel NOTARY P BLIC: Jeanette C Siegel MY miseion FFldy Commission 09997 1L r6$03/0/201 4 + Expires 031 0 8 Sign: — Sig Print: Pr' t• Seal: eal: **�w****x��***�***�x*��**�*�*�e**� *�* �** *******�**x�****�*�*�***�►wry****r�****x����*�***�**x�***�x*s*****x�x���x**�x* APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) � STATE OF FLORIDA ' °'° DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION F oil CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 2601 BLAIR STONE ROAD TALLAHASSEE FL 32399-0783 CORACI, MARY ELIZABETH ALL FENCING AND REPAIR 10681 NW 17TH PLACE PLANTATION FL 33322 Congratulations! With this license you become one of the nearly T -- - - - - one million Floridians licensed by the Department of Business and i , STATE OF FLORIDA Professional Regulation. Our professionals and businesses range i DEPARTME T OF BUSINESS AND from architects to yacht brokers,from boxers to barbeque NN,� restaurants,and they keep Florida's economy strong. i ? PROFE S� tAL REGULATION CGC1517256 �^ `% 08/17/2016 Every day we work to improve the way we do business in order ,�= " to serve you better. For information about our services,please ' to onto www.myfloridalicense.com. There you can find more ,': CERTIFIED GN17FT� information about our divisions and the regulations that impact J: CORACI,MANY 'j , you,subscribe to department newsletters and learn more about ALL FENCING��h }R T , the Departments initiatives. Our mission at the Department is: License Efficiently, Regulate " {• Fairly.We constantly strive to serve you better so that you can is- eliriFiEo u-rtde[ the provisions of Ch.489 FS. serve your customers. Thank you for doing business in Florida, :EViation date,-:AUG 31,_2018 L1608170002569 and congratulations on your new license! DETACH HERE RICK SCOTT, GOVERNOR KEN LAWSON, SECRETARY STATE OF FLORIDA S DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION p CONSTRUCTION INDUSTRY LICENSING BOARD }! ` PGC1517256 'the GENERAL CONTRACTOR Named below IS CERTIFIED s Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2018 CORACI, MARY ELIZABETH ALL FENCING AND REP.P� 10042 NW 50 ST y -SUNRISE —F �2 ` Y _ :" `' • I • "� > ���' +, �`.�; `� {,fix y ISSUED: 08/17/2016 DISPLAYAS REQUIRED BY LAW SEQ# L1608170002569 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT • 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895—954-831-4000 VALID OCTOBER 1,2016 THROUGH SEPTEMBER 30,2017 DBA:ALL FENCING & REPAIR Receipt#: 5GENERLCONTRACTOR Business Name:GOLD COAST INDUSTRIES INC Business Type: Owner Name:MARY ELIZABETH CORACI--QUAL Business Opened:o8/09/2010 Business Location:10042 NW 50 STREET State/County/Cert/Reg:CGC1517256 r SUNRISE Exemption Code: Business Phone:954-605-6236 Rooms Seats Employees Machines Professionals 2 R � For Vending Business Only Number of Machines: Vending Type: I i Tax Amount Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 27.00 i IlTHIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non-regulatory in nature. You must meet all County and/or Municipality planning ..A �nninn ra iiramantc This Rosiness Tax Receipt must be transferred when ,I Will LOCATION SKETCH »W -C' SCALE: ANTS 0'a'a �_ S PROJECT SITE i Y=W CIll ' M Z —> G Z rl m -sees /� • •••••• 0004} ` -/ G . . - o � 4 4444 .: 4444 ••••i .. C%j 000000, 4444 , ......... . N z� Sit0640 •• . • 0. .'.-.t s•°1Qa --� �� - rs t •400•• 0040• ••.1 1 t LOT 9 �1 •.0••0 •• �.� .•.: $ $ 4444 10.00' (M)(R) S89'58'30"E b - ;- 00 - - 4444.. 4:':'::444. . .. .. GLF ....... ... '......... °G : CONC. • 000000 W ONG • •.. • 1. .•0 • LOT f0 •••97.45' •• .0 LOCATMMAP .:.. fl CBS Q , T •• aI r h .. ........ z /a\ $ \ 10.T/ co O a p 3 3 .. ''PORCH-- n >v SSQ��' , �r1 4444.. IRIS®R £ �' TW"TORY _ LAKE o �4444¢.. � .. Z`•ddjj..'.':•.:: •Q N 1w+�IG11�C 11wV1 Q. -..�4444:.04'4'4' • 4444...4444 .. • . ......4444. .. _ �� V 1-1�� 110. 0' (M){R) S89 58'30"E � oa b mW 206.20' {M){R) N68-06"25"E 1::' ::' : LOT 11 `� a 1a � ABBREVIATIONS• swx��DEvlWucCBS=CONCRETE BLOCK STRUCTURE,CLF=ChwNUNKFENCE•PL PROPERT LINE,DUE=DwuNAGEUnl EASE E TIP=1RONPIPE- PROPERTY ADDRESS: 10401 NE 4 AVE., MIAMI SHORES,FC:33138 - F=FOUND,AIC=4IR CONDmONER PAD,PIC--PROPERTY CORNER.Dhi=DRILLED HOLE,VWF VvOODEN FENCE RES=RESIDENCE CL-CLEAR RB=REBAP, UE=LliLITY EASEMENT, CONC--CONCRETE SLAB. RIV1f=R1GHT OF WAY, DE=DRAINAGE EASEMENT CIL=CENTER UNE, O=oWA7ER,TTP=TrPIcAL LEGAL DESCRIPTION: LOT 10,OF MIRROR LAKE SUBDIVISION,ACCORDING TO THE PLAT THEREOF, M=MEJISUF{ED.R=RECORDED,ENCR=ENCROACHMENT COMP.=COMPLIER ASH-ASPHALT,N/D=Ng1L&Disc,steer,FEE=FINISH FLOOR ELEVATION. RECORDED IN PLAT BOOK 56,AT PAGE 15,OF THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA. OIS=OFFSET,P/P=POVER POLE,OHP=OVERHEAD POV ERLINE,NM=M7ER METER r..-MPD FENCE= MASONRYVAU= ELEVATION BASED ON LOC.# NOT VAUDUNLESS EMBOSSED WITH CONCRETE .::,r-,;•,i•,:..•::.:••i,:••� •:••i,:.•:.•:. CBM# " MAINTENANCE&'DRAINAGEEASEMENT=M&D.E DLV. TYPE OFSURVEY. SINCE - _ -''Sl�RVEY4R'SSEA1; SURVEYOR'S NOTES: 1)' OWNERSHIP SUBJECT TO OPINION OFTITLE. 2 NOT VALID WITHOUT THE SIGNATURE Fen CERTIFY That the survey represented eets the minimum technical requirements BLANGO SURVEYORS ING. AND RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 3) THE SURVEY DEPICTED HERE 15 NOT the STATE OF FLORIDA Board of Land' - - COVERED IBY PROFESSIONAL LIABILITY INSURANCE. 4)' LEGAL DESCRIPTION PROVIDED BY CLIENT. . 3). pursuant to Section472.027 Florida Engineers•Land Surveyots•planners•LB#0007059 ONS ARE BASED ON NATIONAL GEODETIC E UNKNOWN8) THERE•MAY BE ADDITIONAL no encroachments, overlaps, easements55 NORTH SHORE DRI�E NDINTHEPU13UCRECORDSOFTH)SCOUNTY. 9) on the plat or visible easementsotherthan MIAMI BEACH,FL 33941 CONTACT THE APPROPRIATE AUTHORITY PRIOR TU ANY DESIGN WORK FOR BUILDING AND ZONING as shown hereon. (30S) 865-1200 Email:blancosurveyorslnc@yohoo.com INFORMATION. 10)EXAM1NATlONOFTHEA85TRACTOFTITLEVVItt}{AVETOBEMADETOD1rTEf�M1NERECOR[3ED Fax: (305)865-7810 REVISED: � - INSTRUMENTS,lFANY,AFFECTINGTHiSPROPERTY. z FIX: ' Additiohs or deletions to survey maps or reports by other than.the signing Party o�'parties is roh>"bited L DATE: 9/11/09 BASE- N/A ��"�JII FLOOD ZONE: X SUF vtcithou#v¢rifi en consent of the sigamgparty orparties. pgDISN.NUNEZ. '. PANEL: 0302 COMMUNITY# 1:20652 BEAR191GS WHEN SHOWN ARE REFERRED TO AN ASSUMED VALU -OF•SAlD PbREGISTERED LAND SURVEYOR DATE: SCALE: DVUN.BY: JOB No PAGE STATE OF FLORIDA#5924 4/3/17- 1•=20' F.Mama 17_369, • Two Rail Style LP Three Rail Stade Three Rail Style Optional Post to Wall Connection " PI 6'Maximum Center to with Bottom " 4 Maximum Center Post S actn �Picket 4 Maximum ,D D ort SEE T-MICKNIM REMARKS —7 CF Concrete Footing 10'clam.x 24' WA Wdrivam 25M PS, CP Concrete Post Mount FILL TD pOST WA Alternate installation to Concrete Deck DR Drop Rod 3W diam.x 2e WA Standard Drop Bolt m GF Geta Frame 2-1/2'x2412° 0.100' Ail comers fully welded • •• • C_ J9 til Hinge WA WA standard 4'HMgew Cto HR Horizontal Rao 1_&8'x1 /8' 0.082' e s•• •• a. ` KS Knox Box TBD WA Coordiruate wHh Local FUA ant • s e• •i r 1-9C = o !A Latch WA WA Standard W4,oddgn4Wi, • • • • ��'y- s ee•' ••• •• C) e 4 CO V LP Lina Past 2-1&x2-11P 0.010 •e•• s•i e Q se• GP Gate Post 2-1/25u2-X 0.100' •• •• • •• •e o Poe PC Post cap 2-1PY5r21/Y WA Do PI Picket 1'x'1' 0.082' � e ; • e •• s•• WC Wd Clip 1318'x1-Ur WA o • • s s e•e " r se •• • s Grade r 4 Maximum CP See Post Connections i 2 Maximum CP See Post Connections Grad i' HR 24" _ /-D ' /ArmCF 10" General Notes for Desian:PC KB LA G 1. This design is for at grade railing Installation ONLY. Installations above grade shall be designed fc conditions for the location. PC 2. Design complies with the requirements of the Florida Building Code 2014 Section 1616.2 and ASCE 7-10,V ultimate=122 MPH for Category 1 —Leaf Varies hurricane with 3 second gust,Exposure D. 6"MaAmuln 3. Installation may be either mechanically connected(screw)or fully welded. 4. Gate leaf,singe or double,widths can be installed up to the allowable size as shown in the Gate Detail. Should a double leaf gate be installed,the PI Latch and Drop Bolt shall be installed per the local requirements. 5. All openings shall be less than 3-11/16"and shall be able to reject a 4"sphere. Hl 6. All exposed visible ends shall be provided with caps or covers. 7. All hardware used for pool fencing enclosures shall be automatic,self-closing and self-latching. Magna Latch and Lokk bolt shall be used in a pool GF E fencing application with latch location a minimum of 54"above grade. 40 8. NO CHANGES are allowed without written authorization from the Engineer of Record. IF E c � 9. All fencing designs have been designed with a minimum of a top and bottom horizontal rail. Additional intermediate rails may be added without GP =0 E affecting the engineering design. The bottom rail is typically located 2"above grade buy may also be located up to a maximum of 6"above grade. All �0 picket thru rail conditions shall be fully welded or mechanically fastened(screw)to top or bottom rails. 10.Fencing line shall meet the maximum height from grade as measured 3'from either side of the fence centerline. Lo pt z o CO HI c General Notes for Materials: 1. All aluminum extrusions shall be made of alloy 6005-T-5 Alloy with a minimum of 35000 PSI yield strength unless otherwise noted. 2. All hardware used for pool fencing enclosures shall be automatic,self-closing and self-latching. Magna Latch and Lokk bolt shall be used in a pool fencing application. Latch Detail 3. Component/Manufacturer List: All components are D&D Technologies items. Hinges(Part#:TCA1 WTL2-MK2),Lokk Latch(Part#: MGHDD1019), Magna Latch(Part#:MLTPS2BGA),24"Metal Drop Bolt(Part# NW38305N-24SSW),24"Lokk Bolt(Part# MGHDR1061 WT) t 4"Maximum Grade _ a Connection Notes for Installation: 4"-I-ypi� 2"Maximum 1. Post Connections: NLokkLatch _ 1.1 Post at Grade: Anchored in 10"x24"concrete with a minimum 2500 PSI concrete. i = ® 1.2 Post Attached to Concrete Deck: Pre-manufactured Aluminum Post Shoe anchored with two(2)1/4"diameter x 3-1/2"Tapcons with a minimum : - 3"embedment. Hinge Detail Drop Rod Detail 1.3 Post Embedded in Concrete Deck: Core drill concrete 4"diameter x minimum of 3"deep and set into deck with high-strength grout with a 3/8"diameter Drop Rod minimum of 10000 PSI strength. &Guide with four(4) Automatic latch whit 2. Wall Clip Connection:Pre-manufactured or 2"x4"x1/8"aluminum bent plate. Aluminum to concrete connections shall be 1/4"diameter x 2-1/4" Adjustable self-closing #12aN Tekscrews Ta cons with a minimum of 1-3/4"embedment. Aluminum to Aluminum connections shall be made using one 1 #8x1"Tek s ew per receiver. A hinge with 4 #12 Tek #12x3/8"Tek Screws m m per manufacturer p 9 O g O requirements single connection is required and additional connections are acceptable and allowed. x screws per manufacturer Lokk Bolt C� t� a 3. Rail/Post Connection: One(1)#8x1"Tek screw. Tru Close W requirements 4. Rail/Picket Connection: One(1)#8x1"Tek screw. HI DR Miayna latch •�i'1® P ® (9Embed frt IM Scale: 0.4" W 1 .0' All Fencing & Repair Designed By: Phillip W. Stevens, PE 10052 SW 50th Street, Sunrise, FL 33351 Aluminum Fence Design Florida PE 54089, Date: 02/16/2015