RF-17-1398 (2) NQ Miami Shores Village �• �, 7Y 10050 N.E.2nd Avenue NE qa rk Iss r W11 Flat Miami Shores,FL 33138-0000 l;Petaw APPROVED h�eN � Phone: (305)795-2204 FioRmA11/ 2017 Date:ateti 6l l21�1 Expiration: Project Address Parcel Number Applicant 361 NE 102 Street 1132060135090 CONNIE BENSON Miami Shores, FL Block: Lot: Owner Information Address Phone Cell CONNIE BENSON 361 NE 102 ST MIAMI SHROES FL 33138-2428 Contractor(s) Phone Cell Phone Valuation: $ 28,600.00 PAUL BANGE ROOFING, INC. (954)981-7663 Total Sq Feet: 2737 Type of Work:Re Roof Available Inspections: Additional Info:REROOF-TILE AND FLAT ROOF Inspection Type: Classification:Residential Up Lift Report Scanning:3 Tin Cap Final Roof Tile In Progress Roof in Progress Renailing Affidavit Review Roof Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-5-17-64098 CCF $17.40 05/26/2017 Check#:4434 $814.40 $50.00 DBPR Fee $4.50 DCA Fee $4.50 05/24/2017 Check*4420 $50.00 $0.00 Education Surcharge $5.80 Bond#:3411 Permit Fee-New Roof $300.00 Scanning Fee $9.00 Technology Fee $23.20 Total: $864.40 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is qcurate and that all 6rk will be done in compliance with all applicable laws regulating construction and zoning. Futhermore,I authorize the above-na ractor to 3�LMay 26,2017 Authorized Signature:Owner / Applicant /, C ractor / Age-617 Date Building Department Copy May 26,2017 1 5�o�s Miami shores Village logo V Building Department -� 10050 N.E.2nd Avenue `-,ree �� Miami Shores, Florida 33138 lOR1UA Tel: (305)795.2204 Fax: (305)756.8972 RE: Permit# � /7— `5�5 DATE: 4�5 /`' INSPECTION AFFIDAVIT Ivl I o licensed as a (n) Contractor JEngineer/Architect, (Print name and circle Ucense Type) FS 468 Building Inspector License#: 6��F-611 On or about Z/ '-6'-;�l ' ! —� I I did personally inspect the roof deck nailing fe work at Pt ) (Complete Job site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly swom,deposes and says that he/she is the contractor for the above property mentioned. `'NELE M,4,T ,���/ •.•Gpct,M""0 Sworn to and subscribed before me this of IV AAY2 PeRu 2,��oA r Notary Public, Sate of Florida at Large %o' G 012 *= �����A�l.'�an ltlsuca;�• Q��r� ////C' 'General,Building,Residential,or Roofing Contractors or any individual c artified under 968 F.S.to make n inspection.I phobgraphs of a co t�e ref writh permit#and address#dearly shown marked on the deck for each inspection 0-40A t—17NnP)niA1nf91 Mnno Job Address S l Permit# F - I `i 1 ; C .Complete the re-nailing affidavit and provide two copies signed and notarized. Post in the permit package at first inspection Re-Nailing Affidavit I am a Florida Professional Engineer, Registered Architect, Licensed General Contractor, Building Contractor, Residential Contractor,_X_Roofing Contractor or Person certified in the structural discipline under FS468. I hereby certify that the existing or supplemental fasteners have satisfied the requirement of table 201.1 (8d round he hank a 6"o. 30- / °'- er 's Signature Date 19 / L1 /L S7 Tint Certifier's Name rerso bscribed before me this -,':0day of Yom- -'�%� 20nally know to me or or produced ID Notary Public State of Florida Seal +° Yvette Borrom to a Ay t Commission FF 974520 Nt ary Publiqt—ate of Florida{signature '�,, L I os►2a►2o2o Complete Secondary Water barrier affidavit and provide two copies signed and notarized. Post in the permit package at first inspection Secondary Water Barrier Affidavit lam a Florida Professional Engineer, Registered Architect, Licensed General Contractor, Building Contractor, Residential Contractor, Roofing Contractor or Person certified in the structural discipline under FS468. I hereby certify that the secondary water barrier has been installed and inspected by me personally it complies with all requirements of FBC 2004 and the Hurricane Mitigation requirements. Certifier's Signature Date Print Certifier's Name Sworn to and subscribed before me this day of 20 Personally known to me or or produced ID Seal Notary Public, State of Florida(signature) �j Miami Shoves Village RECEIV ,0\1\ E Building Department MAY 4 7017 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 rJ Tel:(305)795-2204 Fax:(305)756-8972 �( INSPECTION LINE PHONE NUMBER:(305)762-4949 sh FOC 20 1 --( BUILDING Diaster Permit N®. PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC XROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP � ' I CONTRACTOR DRAWINGS .JOB ADDRESS: 'SCD I we I d 2 JA-e_e_.� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: i I ` 3ay Lo-0f 3, --J DCf D Is the Building Historically Designated:Yes NO Occupancy Type: SF _Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): rn n &e. Re:)w n Phone#:�1:1�s --g1 y Address:s��10 1 6 IDZ �L&-e ef- City: M k 1 Yyli ve—<1 State: (Cs` Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: 2v L Phone#: Address: City: State: Zip: Qualifier Name: , n C -R__ Phone#:Q)Cig j u u, State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ Square/Linear Footage of Work: Type of Work: EJAddition n Alteration 1:1 New 1 El Repair/ eplace ❑ Demolition Description of Work:�l�2 V120 ' Specify color®f color thru file: WI e_ 0(1 l�L�� f• Submittal Fee$ �� -6� Permit Fee$ . 0�S CCF$ ��L- 40 CO/CC$ Scanning Fee 0 1 Radon Fee$ q- E O DBPR$ `7 • 9 Notary$ Technology Fee$ Lam✓ ` 2`J(� Training/Education Fee$ Double Fe--e$�� Structural Reviews$ Bond$ ROO . TOTAL FEE NOW DUE$ � 6 (Revised02/24/2014) 9 4 Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Si natur � E OWNER or AGENT CONTR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this _day of Ar 20 1 by ay of AWLAA 20 by (' a ote �� w o is personally known to wh personally k!10 to CJ me or who has produced as a or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: Print: _ Print: Seal: Notary Publtc State of Florida Seal: NOUN pub Smote of fWda Yvette BWOMW , YV�e BOPfOmeO • r My Commission FF 974520 `• Q my ommgmon FF 974620 0,wd' Expires 03123*020 �°0+4►� ExPires 03x23=0 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) d Miami hores Village sees Building Department 10050 N.E.2nd Avenue 04- Miami Shores, Florida 33138 $ Tel: 305 795.2204 Fax: (305) 756.8972 RE: Permit# DATE: INSPECTION AFFIDAVIT I licensed as a (n)Contractor/Engineer/Architect, (Print name and circle License Type) FS 468 Building Inspector License#: On or about , I did personally inspect the roof deck nailing and (Date&time) Secondary water barrier work at (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned,being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of Notary Public, Sate of Florida at Large *General,Building,Residential,or Roofing Contractors or any individual certified under 468 F.S.to make such an inspection.Include photographs of each plane of the roof with permit#and address#clearly shown marked on the deck for each inspection Revised on 5/2112009 ®�9 � Miami IQOh®reS Village coal n ®a¢m®t" Building Department L�` obi 10050 N.E.2nd Avenue �0 Miami Shores, Florida 33138 Tel: (305) 795.2204 Fac: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE= BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES FERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 23 /7 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: Don P1 r (i &17sp o Property Address: 3Co I E 7 W 0 Roofing Permit Number: Dear Building Official: I 1i6+� /� ���` sa r1 certify that I am not required to retrofit the roof to wall connections of my building because: Ae just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad valorem taxation. ❑The building was constructed in compliance with the provisions of the Florida Building Code(FBC) or with the provisions of 1994 edition of the South Florida Building Code(1994 SFBC) x�Tn - �L Signature Print Name State of Florida County of Dade The undersigned,being the first duly sworn,deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this �2 day of CAW J? Notary Pubft State Of Florida Yvette sorromeo Notary Public, Sate of Florida at Large MYcom 03m"an FF0974620 expimsON When the just valuation of the structure for purpose on is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/2112009 5/12//201177 Property Search Application-Mi am i-Dade County FFICE APPRAISER Summary Report Generated On:5/12/2017 Property Information Folio: 11-3206-013-5090 932 Property Address: 361 NE 102 ST Miami Shores, FL 33138-2428 Owner ERIC BENSON&W CONNIE : -1 Mailing Address 361 NE 102 ST MIAMI SHORES,FL 33138-2428 R -- PA Primary Zone 1000 SGL FAMILY-2101-2300 SQ 0101 RESIDENTIAL-SINGLE Primary Land Use a FAMILY: 1UNIT Beds/Baths/Half 3/1 /0 Floors 1 - Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft og ., Adjusted Area 2,225 Sq.Ft Lot Size 14,625 Sq.Ft Taxable Value Information Year Built 1936 2016 2015 2014 County Assessment Information Exemption Value $50,000 $50,000 $50,000 Year 2016 2015 2014 Taxable Value $144,688 $143,335 $141,801 Land Value $328,606 $315,719 $275,986 School Board Building Value $149,251 $149,251 $145,383 Exemption Value $25,000 $25,000 $25,000 XF Value $41,148 $26,192 $26,480 Taxable Value 1 $169,688 $168,335 $166,801 Market Value $519,005 $491,162 $447,849 City Assessed Value $194,688 $193,335 $191,801 Exemption Value 1 $50,000 $50,000 $50,000 Taxable Value 1 $144,688 $143,335 $141,801 Benefits Information Regional Benefit Type 2016 2015 2014 Exemption Value $50,000 $50,000 $50,000 Save Our Homes Assessment Cap Reduction $324,317 $297,827 $256,048 Taxable Value $144,688 $143,335 $141,801 Homestead Exemption $25,000 $25,000 $25,000 Sales Information Second Homestead Exemption $25,000 $25,000 $25,000 Previous OR Book- Note:Not all benefits area applicable to all Taxable Values i.e.Count School Price Qualification Description pp �� Y, Sale Page Board,City, Regional). 08/01/1997 $0 17776- Sales which are disqualified as a result of 3765 examination of the deed Short Legal Description MIAMI SHORES SEC 1 AMD PB 10-70 E1/2 LOT 19&LOTS 20&21 BLK 37 LOT SIZE 125.000 X 117 OR 17776-3765 0897 4 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: n DAVIE:954-792-ROOF(7663) e STATE CERT CC 0033691 N.BROW:954-566-ROOF(7663) LICENSE®AND INSUREDS.BROW:954-981-ROOF(7663) RUN DADE:305-981-ROOF(7663) 7000 S.W.21 ST PLACE FABS:954-964-ROOF(7663) DAVIE,FLORIDA 33317 1-877-981-ROOF(7663) ® Member of ropoor Better Business Bureau PROPOSAL SUBMITTED TO DATE PHONE —a6 - 7 3os• 3.3•.3 NAME o 6 JOBNAME STREET p �O so SGI ;?Mid STREET CITY t f _I ar STATE ZIP EMAIL � 3 3 CITY �( STATE IZIP We hereby submit specification and estimate for 7P P WORK SHINGLES Remove existing roof to a clean Workable surface and ❑ Install# dispose of debris. base sheet. ,� ❑ InstallV.'i n.save drip metal. Z Replace rotten sheathing at$_Y=00_per foot. ® Installassfungus resistant shingles. _/(Plywood replaced by square ft.) /00 r.�odd i�install new lead flashing to all plumbing vent stacks. Color ® �fg Color Install new 26 gauge 16"galvanized metal to all METAL Reys and tie-ins. All averk 9 ah s ® Install v Zunder layment. posed ®ftiot Exposed ® Install# fire barrier. Type of roof to be removed -77/G _,. ❑ Install save drip metal. PFS'ROOF/LOW SLOPE Ll Install metal roof. a� stall# base sheet as per code. ��Y1�nstall A'O plys of ply IV figerglass felt. Tin.-Stall 3�G07 Install �l t 3 g 3 n.save drip metal. #.� base sheet. /� r/ �Il stall mineral surface ca sheet. stall fel% 3 3�In.save drip metal '®] Install tappered insulation:Yes No� 'fdt stall _5, d I,i�yA the derlayment. ease Initial_ Fk Install tin Repair S+t1CCo (,�f-k tAltiJ�c(os o�� o s, s : a s I`V1 v mp 'a t?eG `a sAdd 33 •� y es o a�rravl w C,Give, Ovetr ke-ga CgYi b M y-s�,`> a�• 4 Ifo . We herby ropose to furnish labor and materials compl to in accordance with the above specifications forthe sum of e a S S' �V� err A7 dollars($ 028(2w.Oo Payment to be made as follows ry f7 ®�r W O 5 ®�O /) C q d —LO r / METRO®OF PAYMENT: ® ® ct G�lar�G- n�I I' HYD' -A C���� ,J � Crcrc� Pat �Ar7 s WMRENW TO 01 CUMER:Paul Barge Rudng Inc.wafrefds workinansliip for a period of CUSTOMER IS URGED TO COVER FURNITURE AND OTHERNIISE PROTECT THEIR PROPERTY years. THIS CONTRACT IS SUBJECT TO OFFICE APPROVAL Authorized Signature Roofing Specialist o ACCEPTANCE OF PROPOSAL ACCEPTED t;lgrrature prhw +i i��e_n s d7 Data d 7 vowjF- 1� 'a Florida Building Code Sth Edition(2014) High-Velocity Hurricane zone Uniform Permit Application Far INST'RUCT'ION. PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: LLow Required Sections of the Attachments Required Permit A lication Form See List Below Slope Appilcatio A,B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 Asphaltic Shin les A,B,D 1,2,4,5,61,7 •.• . . ... 0WI .. ... Concrete or Clay Tile A,B,D,E 1.2.3.4.5,6,7' .' : : 000.00 .. . .. ... Metal Roofs A,B,D 1,2,3,4,5,5,7.... .. :• ••: 0000 . . 0000 Wood Shingles and A,B,D 1,2,4,5,6,7 0000.. .. . 0000 Shakes •• •• •••• .. ••• Other As Applicable 1,2,3,4,5,6 0• 000:0 .0.. . . . ..4 .0. ATTACHMENTS REQUIRED: 1. Fire Directory Llstlng Page 2. From Notice of Acceptance: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detall Drawings S. Design Calculations per Chapter 16,or If Applicable, RAS 127 or RAS 128 4. Other Component Notice of Acceptances 5. Municl al PennitAp licatton 6. Owners Notification for Roofing Considerations Re•Ro6M Onw- 7.1 Any Required RoofTestin tCalculatlon Documentation MI�►W�8 E_. "Delivering Exc-/crew Emery Shay" t ------ I-DADE COUNTY -- REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS It is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this form. The owner's initials in the designated space indicates that the item has been explained. E. 1.Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zo ) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion perforinance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance,that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be re 'led in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida T Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation betweerufitig$boring . ..... townhouses, condominiums, etc.). In buildings with common roofs,the roofl�gcQntractpr•Ekd/or •• . . owner ould notify the occupants of adjacent units of roofing work to be performed. •••••• •• • Soso:* 4.Exposed ceilings: Exposed, open beam ceilings are where the underside of the ro de�kiJJg cart e • vi ed from below. The owner may wish to maintain the architectural appearance; tbjje q�e,roU&mail penetrations of the un rside of the decking may not be acceptable. The owner providesW option of ...... m 'nta'ning this appe ance. • . . . . ...... ...... 5.Ponding water: The current roof system and/or deck of the building may-n at ain well and mEc, ... cau e water to pond(accumulate) in low-lying areas of the roof. Ponding can be an indication of strtiiural dr ress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing ystem is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not ov r oaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance w't e requirements A. Chapter 15 and 16 herein and the Florida.Building Code, Plumbing. 7.Ventilatio : Most roof structures should have some ability to vent natural airflow through the int rior of the structural assembly(the building itself). The existing amount of attic ventilation shall not be re uced. Owner's/Agent's Signature: Date: Contractor's Signature: 7 Permit Number: Property Address: (�_ N _ l�off. .a5 a !t = ' � ;al • � 1': I k1: t 1 777, r,77j -XjQ(��Yi#R1 !■�1■Elf M! ! Ril■ilMliRM■ililllFllR#!l■1##■#■iM■##l7�R 7fi!!� RIE[ M !i'sRlR Ring a H RM1�I M►.�t1M! Cf 11#1{ wG�YM MWil1M MARK t.a >ERl ■ ,kk .! V#i## i#1l l of 41 U( RICH x#MM R�%� RiRI M�lilXR �R1i li�I1li[1p"till Y X�s 'if lilililMif :Ci1��1 AZII 1E F#iI�MiZIXR!�[■li RR■■ ■anl I#1 it' 41,41 1nt,Va n ■i!Ya ■ 1##! i R# � Mei iiYstt= !!% � w 't■ll t ll�l CEL # 11>if■ !■■ll>1�M�w#11M� R ■ i�il ■iliMii ■ E ! Ii c Rin 01�i�R M!I•''�M�K #i`#•1l!#!. � �1!R 11lR N M�■■R## M � Ii Mi R #■f�# �! ■ p, �. X11 ■ lii ■ M 1Rl��! iMlllJlllil. M!#■##■ 1 ! 1Mll 1 I! ■ #■ ii 1 # 1 E �1Rk 11 �-11i�f1 1 MM R 11 �K°M,L ■i_ #■i ■■R■11MR ■■ ■ii■ 1ylf �f If i� �■ iiR #�1 i1iIM■MI #RR� r E fMfM lMrllwtRza 1M llf�MGM�i 1 11�Hiil�l FCL L■�If 11 ■ fill €i .Mail M ## R M'i ■1!# ■#1 ■ ■ ii ■�I rililiR ■M R .4 �IiJI. �3c ► # R# 1 1�+ !1# Ml#1 on ��■ %ilion Mi! �AaRia1::1 11 # ■ 1 3 I ■R� � ■fl Pt'1! _■,� R!l R1lR ■■ ■ # ■ ■ Ril # 1111 i i�j � 1a R �R�ii/ 1 E fRiaE %R�RII#r a # Mof� R■�� #� �R (� W! RR■ ■ � � i!j ■■ f 1!� � 111 � R I �■ ■ R ■ � ! 117;i�T llriRl� # fli I■■ # R1 R■�■ i �■ ■R # 1Ml RII R■ ! ■ ■ R got, x X ki Mi#1 1M1 IN rl[IRVINE i K l � 1 Mill ■i■i i ii!! 1111 llM Mli j! l I iil■■i Mlfiif lil 1l 11! [I!YI##ia �M 1�1■■ #lil� 1 ■ >r.#�iCl!MRi ■M Crl1 ■� lli it i■ !MM#f iM■Ri# I# MM MM ■ i'i #!#■ 1�1 i::i 1111! 1 !■ ■ Mi i i a�1#MMI #i�C�TJr^_i 1I�# #i 1!i1# 11�j# �J'�R 181 1 MR # liM MMI as ■� ■i# !� {r �^ liil111■lilt J G'il I■ Ml�#�i i/ M11i �i'i,�■ MM■R■■//�� R■ M #MiMliM no in � all �n ! !i■ 11 i #I 110 1111 f ti MVART Al�0ll1 111 ff!1�■� R 1■[i logIng l5 �iM 1 # R !!1 I #w ■ i� ■ ■i l ■I l ifllM t� ■��"i'` ! ■1#�'rl ■ IR 1 11lM l l■■■ 1 it UP; a�G� ���C1l16M11! l�lRl�■ on No i ■■R IJIII�/� IM�: I�Mi1 i ■ • Go## .ait1ik � .�A ■R I# ! i li R ■! rl L, '3l i !1 11PA I#11Pi' M ■�" C�R �M �fi�1� 11 I MiIM 111 !II C��r:•i�i ■ #■ � �I ij■ ►f(�' j M�j ■ I z ? �9 10 ■ i■ �l #■tliimin 11 ■ VI y ■�Ri�� �Ml A i 'G{f�i 1 Ml[ i IRllr� �! ■1 M# ►►��I■ �! RIIMy�j 1 ■# i1R 1�i1R# v R 11 RR ■ # Iris # ■MK ! rrr� u rra rr �rarrrG�rrGrSrr�r r�rrr�G�rrrris� !R■!s l " 'i■ii sai�MY1 M�il1■� ■islk�s ■�■�M 111111111011169 ■M■■■■■■■I■��iM #iM■■ M ■ii iI M M■ R 1 ■� 1 �M Mi I R �ti iiE�M a mr!■■*i � )1lii i rii � �� SIR 11i ; %INMR M*0 11 1■ RI# #ll � CCi i�` xi�lM ■ MElMII■o-P%ill1 1R .�% M■ � ■ # ■■ R lfli !■ 1#� lL ■ # R M#1 1 C.■ M ■r'1� l gas \ .,>r- min 1 # ■ �R�r Ri ■� ■ � � MI R l# ■ owa awl IN � ! M 1l 00101191111100 as E Lrit #Afi �1 R C 1 Y : R YR ■ lii R■ Mr■ fji�l■ Ili■SMR l i��IM�Mr�>i�����l .�iRl1l A#■i ■R■ I1 ■ ■ ■ ■ISR■ ■■■ ■ R ■RR .r�r►r�ir�_rri�re:rr ri.+�. .■ ■ # l� ArirllRiE MMl ■ 1r ■;■ >lNMI �MMMiiMMl1!<>tx■�Y[�liY • Fill In Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used Idents as"NA') system Manufacturer.Cal ��t�- Field: °oc @ Lap,#Rows @ °oc NOA No.: q r Perimeter:--!L-oc @ Lap,#Rows AL@ °oc Pages&07cate applicable NOA pages): Comer:� oc @ Lap,#Rows A@ °oc Design Wind Pressures,From RAS 128 or Calculations: Pmax1:�Pmax2: f A 4 Pmex33: Number of Fasteners Per Insulation Board Max.Design Pressure,From the Specific NOA Field: Perimeter Comer System: Deck: �o� Illustrate Components Noted and Details as Type' Applicable: / Gaugelfhtckness: Wood blocking, Gutter, Edge Termination,Stopping Flashing, VContinuous Cleat,Cant Strip,Base Flashing,Counter-FLVDWg, Slope: !/ d`'' / Coping,Etc. •....• ...... Indicate• Mean Roof Height, Parapet 61ght, hielglit.of s Anchor/Base Sheet&No.of Py(sy Base Flashing, Component Materls4.164010d8l Tl1igllh8$s, ...... char/Base She F' 01a toner/Bon in Ma n : Fastener Type , Fastener Spacing or,J*pjt ManufacUirer's • Details that Comply with RAS 111 and%rigor 16. •••••• 611 • • • • • Insulation Base Layer Al ••'•' •••• ••••• Base Insulation Size and Thickness: • Bull v- op4spet ....:. Base Insulation Fastener/Bonding Material: �� ' F;• Fjeight ;... •• • •••••• 0 ••• 0 • • Top Insulation Layer •• Top Insulation Size and Thickness:WJ14 X e DT Ar To •Insulation Fasten r/Bpndin fieri I: F p o? �fJ/1��" � 1�iA Base Sheet(s)&No.of Ply(s): N D _J FT Mean Base Sheet FasteneriBonding Material: ,l//� C• Roof Height Ply Sheet(s)&No.of PIy(s): Ply Sheet Fastener ponding Ma ria`) TOP Ply.00t'Y dvyfit��t ii�l�/1t+C/ '/ GM' S Top Ply FastenerlBondingtv�// t' Surfacing: 6A,14 i i MIAMI- MIAMI-DARE COUNTY ® PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.mianddade.uoy/econorny CertainTeed Corporation 1400 Union Meeting Road,P.O.Box 1100 Blue Bell,PA 19422-0761 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Mianu--Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Mian-ii-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within •••. . 6666 6666.4 their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by lauuZade *0 County Product Control Section that this product or material fails to meet the requiremen0:00ts of the • • applicable building code. 696964 f 6666.. This product is approved as described herein,and has been designed to comply with the Flositl6666 .. 6666. wilding . •. Code including the High Velocity Hurricane Zone of the Florida Building Code. 0 00000 :0 00 0 6:.0• 6 6 • •• 90 9000 6690.• ? DESCRIPTION: CertainTeed Conventional Built-Up-Roof Systems over Wood Deck;0 0 6 0 0 0 0• 0 0 0 0 LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo�city,�date an8...:. """ following statement:"Miami-Dade County Product Control Approved",unless otherwise notgi Kevin. 6 :•6••0 RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been • no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure j to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No.08-0410.07 and consists of pages 1 through 16. The submitted documentation was reviewed by Jorge L.Acebo. f NOA No.: 13-0204.14 [AMI- Expiration Date: 06/19/18 C ECOUNTY� Approval Date: 05/30/13 Page 1 of 16 i i j t ROOFING SYSTEM APPROVAL !9 ory• Roofing Sub-Category: Built-Up Roofing Material: Fiberglass Deck Type: Wood Maximum Design Pressure: -60 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE e Test Product Product Dimensions Specification Description All Weather/Empire 36"x 65'10", ASTM D 4601 Asphalt coated,fiberglass reinforced base Base Sheet Roll weight: 86 lbs. Type II sheet. (2 squares) UL Type 15 Flintglas®Mineral 36"X 32'10"; ASTM D 3909 Asphalt impregnated and coated inorganic Surfaced Cap Sheet Roll Weight:78 lbs. glass fiber surfaced with nuneraj granules0 0.0• 0 0 0•• (1 square) used as the top ply in convtsv4Sn4 built-tip ... •• roof membranes. 0.0.0. sees : ....:. Flintglas®Mineral 36"X 32'10"; ASTM D 3909 Asphalt impregnated and coa1cd s.inorgagii %••• Surfaced Cap CoolStar Roll Weight:78 lbs. glass fiber surfaced with ntiggW granulp•..• 66066 (1 square) used as the top ply in convestioval built up... Osseo• roofinembranes. Covered0wlikAflectimm:. 0..... CoolStar Coating. •••••• • *see:. Flintglas®Ply Sheet 36"x 164'7"; ASTM D 2178 Fiberglass,asphalt impregyated,ply sheer.•••• • i....i Type IV or VI Roll weight:40/55 Type IV or VI sees ••• • • lbs. UL Type G1 • (5 squares) Flex-l-Glas Base Sheet 36"x 98'9"; ASTM D 4601 SBS Modified,fiberglass reinforced base Roll weight:90 lbs. Type Il sheet. (3 squares) UL Type G2 Flex-I-Glas FR Base 36"x 98'9'; ASTM D 6163 SBS Modified,fiberglass reinforced base Sheet Roll weight:90 lbs. Grade S sheet. (3 squares) Type I GlasBaseP'Base 36"x 98'9"; ASTM D 4601 Asphalt coated,fiberglass base sheet. Sheet Roll weight:69 lbs. UL Type G2 (3 squares) Black Diamond"' 36"x 68'7';Roll ASTIVI D 1970 Self-adhering fiberglass reinforced Base Sheet weight: 78 lbs. modified bitumen base sheet (2 squares) NOA No.:13-0204.14 MIAMt•DADEGOUNTif Expiration Date: 06/19/18 �mv.. , Approval Date: 05/30/13 Page 2 of 16 i E I APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) FlintBoard ISO Polyisocyanurate foam insulation CertainTeed Corp. ; i ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corporation High Density Wood Fiberboard Wood fiber insulation board Generic Perlite Insulation Perlite insulation board Generic H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC DensDeck,DensDeck Prime Water resistant gypsum board Georgia Pacific Gypsum LLC ENRGY 3,ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp. Multi-Max-3,Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating,LLC. APPROVED FASTENERS: TABLE 3 • •• Ir • a Fastener Product Product Matuf otyrer •• • •••••• • Number Name Description Dimensions (With COtrci t NO0 :•: •• ...... .. . ...... 1. Dekfast Fasteners#14& Insulation fastener SFS;iatea,.Inc. • #15 HS "" 2. Dekfast Galvalume Steel Galvalume AZ50 steel plate 2 7/8"x 3'/" SFS tff to Inc. `••` .••.. `o` . Hex Plate .••••• • "`•` . 3. Dekfast Dekflat Round Polypropylene plate 3"x 3'/4" SFS 1nfet,Inc. "•••;• Plastic Lock Plate • . . ...... 4. #12 Standard Roofgrip& Insulation fastener for wood 4MG,I n.c. ••••. #14 Roofgrip and steel. S. AccuTrac Hextra Insulation fastener for wood OMG,Inc. •• and steel 6. 3 in.Ribbed Galvalume Galvalume stress plate. 3"round OMG,Inc. Plate j 7. AccuTrac Plate Galvalume stress plate. 3"square OMG,Inc. 8. 3 in.Round Metal Plate Galvalume AZ50 steel plate 3"round OMG,Inc. 9. Trufast#12 DPH& Insulation fastener for wood Altenloh,Brinek&Co. Trufast#14 HD Fastener and steel decks U.S.,Inc. 10. Trufast 3"Metal Galvalume AZ50 steel plate 3"round Altenloh,Brinck&Co. Insulation Plate U.S.,Inc. f i } NOA No.: 13-0204.14 raartFnaoecornvrir Expiration Date: 06/19/18 Approval Date: 05/30/13 Page 3 of 16 { I i a a EVIDENCE SUBMITTED: Test Agencv/Identifier Name Rep Date TrinitylERD TAS 117(B) 3503.10.06 10/10/06 TAS 117(B) 06490.04.07 R 1 06/27/07 TAS 117(B)/ASTM D6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C10080.09.08-R4 03/25/10 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D3909 C44200.03.13 03/22/13 ASTM D1970 C40050.09.12-2 09/28/12 Momentum Technologies,Inc. ASTlbI D 4601 AX31 G8D 09/05/08 ASTM D 3909/D 4897 AX31 G8C 09/05/08 Factory Mutual Research Corp. FMRC 4470 J.I.#3Y8A1.AM 03/23/96 FMRC 4454 J.I.OD3A3.AM 04/04/97 FMRC 4470 J.I.2DOAO.AM 12/23/98 FMRC 4470 J.I. 1D7A4.AM 11/09/98 Underwiters Laboratories,Inc. UL 790 RI 1656 01/11/13 �•�� United States Testing Company ASTM D 5147 97457-4 O6V/88 •00 00• *Go*:* ASTM D 5147 97-457-2R `12/02/87 . 606.96 PRI Construction Materials ASTM D2178 CTC-122-02-01 ••63/18/12 • 0• I Technologies LLC ASTM D2178 CTC-123-02-01 .'63/93/12 ;• •• • ASTM D6163 CTC-066-02-01 008109/11 ' 06 •0;00 6 ASTM D4601 CTC-127-02-01 ..••§M/12 :•so 0 00 0 .. 6666 6666.. 966699 699900 0 0 e 6666.. i t i NOA No.:13-0204.14 j Mugu-DADeeamnr Expiration Date: 06/19/18 Approval Date: 05130/13 Page 4 of 16 7 APPROVED ASSEMBLIES: Deck Type 1I: Wood,Insulated Deck Description: 19132'or greater plywood or wood plank System Type A(1):Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor sheet: All Weather/Ennpire Base Sheet,Flex-I-Glas,Flex-l-Glas FR or GlasBase base sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be lapped 4"and fastened with approved roofing nails and tin caps 9"o.c.in the lap and two rows staggered in the center of the sheet 12"o.c. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ENRGY 3,Multi-Max-3,H-Shield Minimum 1"thick N/A N/A Approved Perlite Minimum 3/"thick N/A N/A .••• . . 0000 0000.. Approved High Density Wood Fiberboard • N/A }�/A • :0: •• • Minimum%z"thick i i 0000 .. . 0000.. DensDeck,Dens-Deck Prime 000. Minimum'/"thick N/A "'NJA 0 . 0000 . .. 00000.. Note: All insulation shall be adhered to the anchor sheet in full mopping of approvedGhgt.Whalt 0... 06:060 within the EVT range and at a rate of 20A0 lbs./100 fe. Please refer to Roofing Applin W11 •.••:• Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall belled 00 only as base layers with a second layer of approved top layer insulation installed as the final• :.00:. 0.6 6.6 membrane substrate. Composite insulation panels may be used as a top layer placed ivitit i to • polyisocyanurate side facing down. •• •••6 0 Base Sheet: (Optional)Install one ply of All Weather/Empire Base Sheet,Flex-I-Glas,Flex-I- 00 Glas FR or GlasBase base sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 20-35 lbs./sq. Ply Sheet: Two or more plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)or ASTM D226,Type I sheet adhered in a fill mopping of approved asphalt at an application rate of 20-35 lbs./sq. Cap Sheet: (Optional)One ply of Flintglas Mineral Surface cap sheet or Flintglas Mineral Surfaced Cap CoolStar adhered in a full mopping of approved asphalt at an application rate of 20-35 lbs./sq. Surfacing: (Required if no cap sheet is used)Any coating,listed below,used as a surfacing, must be listed within a current NOA.Install one of the following: I. Gravel or slag applied at 400 lb./sq.and 300 lb./sq.respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC#300 Asphalt Fibered Emulsion at rate of 3 gal./sq.;surfaced with 1 gat./sq.APOC#212 Fibered Aluminum Roof Coating. Maximum Design f Pressure: -45 psf(See General Limitation#9) NOA No.: 13-0204.14 MuiogoEeouNnr Expiration Date: 06/19/18 AM, ...� Approval Date: 05/30/13 Page 5 of 16 i s Deck Type 1I: Wood,Insulated Deck Description: 19/321'or greater plywood or wood plank System Type A(2):Anchor sheet mechanically fastened;all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Anchor Sheet: All Weather/Elnpire Base Sheet,G1asBase base sheet or Flintglas Premum Ply Sheet mechanically attached as detailed below. a Fastening: Anchor sheet shall be lapped 4"and fastened with 11 ga.annular ring shank nails and approved tin caps 8"o.c.in the lap and three rows staggered in the center of the sheet 8"o.c. One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe ENRGY 3,Multi-Max FA-3,ACFoam-II,F1intBoard ISO,H-Shield Minimum 1.5"thick N/A N/A Approved Perlite 1%lininmm 314"thick N/A NIA 0 0 0 0 Approved High Density Wood Fiberboard •••• •••••• Minimum%z"thickN/A •' N/A :•: '• .00.00 DensDeek,DensDeck Prime •••••• ' 0000.. 1Vlhdmum%11 thick N/A •••?1/A •• • d 0000 0 00 0000. Note: All Insulation shall be adhered to the anchor sheet in full mopping of approved hot.ssphalt ••;••• within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Applicptijop' ••;. �. Standard RAS 117 for insulation attachment. Insulation listed as base layer only shau bewd only as base layers with a second layer of approved top layer insulation installed as tt&fidac 000000 membrane substrate. Composite insulation panels may be used as a top layer placed witl:llie 0• •0.0 polyisocyanurate side facing down. •••. • Base Sheet: (Optional)Install one ply of All Weather/Empire Base Sheet,Flex-I-Glas,Flex-I- •' Glas FR or GlasBase base sheet directly over the top layer of insulation. Adhere with any approved mopping asphalt at an application rate of 2040 lbs./sq. Ply Sheet: Two oriuo,plies of Flintglas Ply Sheet(Type IV)or Flintglas Premium Ply Sheet(Type VI)or ASTM D226,Type I sheet adhered in a full mopping of approved asphalt at an application rate of 2040 lbs./sq. Cap Sheet: (Optional)Only of Flintglas Mineral Surface cap she or Flintglas Mineral Surfaced Cap CoolStar adhered in a full mopping of approved asphalt at an application rate of 2040 lbs./sq. Surfacing: (Required if no cap sheet is used)Any coating,listed below,used as a surfacing, must be listed within a cuiTent NOA.Install one of the following: 1. Gravel or slag applied at 400 lb./sq.and 300 lb./sq.respectively in a flood coat of approved asphalt at 60 lb./sq. 2. A two part coating consisting of a base coat of APOC#300 Asphalt Fibered Emulsion at rate of 3 gal./sq.;surfaced with 1 gal./sq.APOC#212 Fibered Aluminum Roof Coating. R Maximum Design Pressure: -52.5 psf(See General Limitation#7) NOA No.:13-0204.14 MIAMI•DADECOUtJTY Expiration Date: 06/14/18 Approval Date: 05/30/13 II Page 6 of 16 { I I MOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with ° Product Control Approval guidelines. All other layers shall be adhered in a frill mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq.,or mechanically I attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied inapproved asphalt,panel size shall be T x T maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8"ribbons in three rows,one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either system shall°... be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a ivaxim �n u ....° see*:* design pressure of-45 pst °°° ° 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force Wtealue of•• goose* 2751bf.,as tested in compliance with Testing Application Standard TAS 105. If the famt?Oalue, ;....: as field-tested,are below 2751bf.insulation attachment shall not be acceptable. ."". :°. °• • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based • . .... Goose on a minimum fastener resistance value in conjunction with the maximum design value* 0..sd +vithin0000 eeeese a specific system. Should the fastener resistance be less than that required,as determigeAhote e Building Official,a revised fastener spacing,prepared,signed and sealed by a Florida*gidte*d . 000000 Professional Engineer,Registered Architect,or Registered Roof Consultant may be suhmitted. Said: °'°° s e revised fastener spacing shall utilize the withdrawal resistance value taken from Testinj4plication.G Go %G •**o Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. •• 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed i by a Florida registered Professional Engineer, Registered Architect,or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation#9 will not � be applicable.) j 8. Ali attachment and sizing of perimeter naileis,metal profile,and/or flashing termination designs shall conforin to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE I NOA No.:13-0204.14 MIAMFDADECOUNTY Expiration Date: 06/19/18 Approval Date: 05/30/13 Page 16 of 16 I 2/13/2017 YGFU.R11656-Roofing Systems )i i .ili �i Roofing Systems Page Bottom Roofing Systems i See General Information for Rooflna Systems R11656 CERTAINTEED CORP ROOFING PRODUCTS GROUP 20 MOORES RD MALVERN, PA 19355 USA "1/2-in.thick(minimum)gypsum board or 1/4-in. thick(minimum)Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard" or"DensDeck@ Prime Roofboard"or"DensDeck@ DuraGuardn'.Roofboard"or 1/4-In. thick(minimum)United States Gypsum Co. "SECUROCKO Roof Board" (Type FRX-G) or"SECUROCKO Glass-Mat Roof Board"(Type SGMRX) may be used in any existing noncombustible deck Classification.When this is done,the resulting roofing system is acceptable for use over combustible(15/32-1n. thick minimum) roof decks. However,the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC"DensDeck@ Roofboard"or"DensDeckO Prime Roofboard"or"DensDeck@ DuraGuard*" Roofboard" are to offset a minimum of 6-in.with the butt joints in the roof deck. If polystyrene is part of the roof system,it must be placed below the overlayment board. 1/4-in. thick(minimum) United Sates Gypsum Co. "SECUROCKO Roof Board" (Type FRX-G) and"SECUROCKO Glass-Mat Roof Board" (Type SGMRX) are limited to a maximum 3:12 slope when used over a combustible roo1jink in a system with any UL Classified insulation except polystyrene." 0 0 e 0 0*0• e 0 09:0 Any UL Classified Insulation may be used underneath 1/2-in. thick(minimum)gypsum board or 1/4-In, thick(minWorn�Georgla-gyp 6196 e Gypsum LLC"DensDeck@ Roofboard"or"DensDeck@ Prime Roofboard"or"DensDeck@ DuraGuardm Roofboard"gra 1/4-In. thidk Qfin1Cnum) 0 so 0:0 United States Gypsum Co. "SECUROCKO Roof Board" (Type FRX-G) or"SECUROCK@ Glass-Mat Roof Board" (TA;SG�2X) In any existin000000 g noncombustible deck Classification. •""' Mineral Wool Felt,is a suitable alternate for perforated Type 15 asphalt organic felt in the Class A,B or C roof cdh§Uglbns Indicateq p@low. 0 Type GI"Flintglas Ply Sheet"Type 4 or"Fllntglas Premium Ply Sheet"Type 6 are suitable alternates for Type IS%tVhMfelt;Typeb2 or ••••• "Glasbase Base Sheet"is a suitable alternate for Type 15 and Type 30 base sheets;Type G3"Fllntglas MS Cap" Is a suitable altate for Types.•• • 30 Cap Sheets. "Flex-I-Glas","Premium Flex-I-Glas"or'Flintlastic Base 20 Sheet"is a suitable alternate for thesT�vVi; glass baseeand the Type 15"All-Weather/Empire base sheet". •e •e• Unless otherwise Indicated, base sheets are mechanically fastened or spot mopped in place; ply and cap sheets axe hot mopped h pace. Two plies Type G1 may be utilized in place of one ply Type G2. 'e; "Flintlastic Ultra Glass SA"is a suitable alternate for Type G2 base sheet or"Glasbase Base Sheet". "Black Diamond Base Sheet"is a suitable alternate for Type G2 base sheet or"Glassbase Sheet". "Flintlastic SA Nailbase"or"Flintlastic SA Plybase" are suitable alternates for Type G2 base sheets In Roofing Systems(TGFU)that limit cover applications to self-adhering ply/base sheets or membranes. EPS insulation followed by 1/2-in.thick cover board may be utilized In any of the following roof covering systems. The"YOSEMITE Venting Base Sheet" may be used in any of the following noncombustible deck roof systems and,where indicated, in combustible roof deck systems. I! "Torch APP"may be utilized in any of the following systems that contain"Flintlastic STA". "Flintlastic APP Base T" is a suitable alternate for any Type G2 base sheet. "Flintlastic Ultra Poly SMS" may be used in lieu of"Poly SMS Base"In all application Classifications. References to Type G2 base sheets includes"Channel-Vent GB". "FlintBoard Iso", "FlintBoard Iso Cold", "FlintBoard Iso-T"or"FlintBoard Iso Plus", may be used wherever polylsocyanurate insulation is specified. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated Incline or thickness. "FlintBoardH ISO","FlintBoardH ISO Cold', "FlintBoardH ISO WF', "FlintBoardH ISO F","FlintBoardH ISO NB"and"FlintBoardH ISO DD" may be used wherever polylsocyanurate insulation is specified. "FlintBoardH ISO T","FlintBoardH ISO T Cold" and"FlintBoardH ISO T WF" are acceptable alternatives to"FIIntBoardH ISO", "FlintBoardH ISO WF"and"FlintBoardH ISO Cold",respectively, provided they do not exceed the indicated incline or thickness of the system. Any UL Classified EPS,any thickness,may be used below"FlintBoardH ISO","FlintBoardH ISO T', "FlintBoardH ISO Cold","FlintBoardH ISO T Cold","FlintBoardH ISO WF","FlintBoardH ISO T WF","FlintBoardH ISO F", "FlintBoardH ISO NB"or"FlintBoardH ISO DD"insulation on non- combustible decks provided a minimum 1-in.thick layer of"FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold","FlintBoardH ISO i T Cold","FIIntBoardH ISO WF", FlintBoardH ISO T WF","FlintBoardH ISO F","FlintBoardH ISO NB"or"FlintBoardH ISO DD" polyisocyanurate 1/22 httpi/datebase.ul.cofn/Cgi-bin✓XYVAemplateJUSEXT/1FRAME/shovr pap htmi?name=TGFU.RI1656&omhortUge=Rooting+Systems&oblid=1074351981&cfg... i i 2/13/2017 TGFU.1111656-Roofing Systems Insulation is used. Max Incline shall be in accordance with Classification established for the insulation/membrane roofing system, but cannot exceed 1:12. I-or Combuptible Roof Decks-Class A: 1. A minimum 3-in. layer or a minimum two layers of 1.5-In. of"FlintBoardH ISO Cold"or"FlintBoardH ISO T Cold" is placed directly over a combustible roof deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification.As an alternative,any UL Classified Insulation(except expanded or extruded polystyrene), any combination,any thickness, may be used below the 3-in. minimum total thickness of"FlintBoardH ISO Cold" or"FlintBoardH ISO T Cold".The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive.A vapor barrier(non-UL classified) may also be used below the insulation.All insulation joints must be staggered a minimum of 6-in. from the butt joints of the roof deck or from the insulation joints directly below.The maximum incline shall be In accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 112:12, 2.A minimum 1.9-in. layer of"FlintBoardH ISO Cold" or"FlintBoardH ISO T Cold" is placed over a minimum 1 layer of Carlisle "FR Base Sheet IS" or GAF"VersaShield FB-1S"over a combustible roof deck.The insulation is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation(except expanded or extruded polystyrene),any combination,any thickness, may be used below the 1.9- in.minimum total thickness of"FlintBoardH ISO Cold"or"FlintBoardH ISO T Cold".The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier(non-UL classified) may also be used below the insulation.All insulation joints must be staggered a minimum of 6-in.from the butt joints of the roof deck or from the insulation joints directly below.The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly,however the incline cannot exceed 1/2:12. For Combustible Roof Decks-Class B: 1. A minimum 1.9-in. layer of"FlintBoardH ISO Cold"or"FlintBoardH ISO T Cold",or a minimum 2-in.thick layer of Atlas "AC Foam III"is placed directly over a combustible roof deck and Is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification.As an alternative,any UL Classified insulation(except expanded or extruded polystyrene), any combination,any thickness,may be used below the 1.9-in. minimum thickness layer of"FlintBoardH ISO Cold"or"FlintBoardH ISO T Cold".The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive.A vapor barrier(non-UL classified) may also be used below the insulation. All Insulation joints must be staggered a minimum of 6-in.from the deck joints or from the Insulation joints directly below.T40000 maximum Incline shall be in accordance with the Classification established for the membrane/insulation roofing Issemblys,•0 0 0• 000000 however the incline cannot exceed 1/2:12. • 0 ' 0 000 0 Unless otherwise indicated"Glasbase"Is an acceptable alternate for Type G2 base sheet in all applicable CertlficaFianGO 0 0 6.6 : •••• • Unless otherwise Indicated the following membranes are acceptable alternates for the following membranes tabulaNc?6418w,limited to 1/2-in. ;...•: incline: 0 sees •es •• go 0 0 0000• Membrane Acceptable Alternate 000090 ••• b "•" • • • 0.• 0000•• • Flintglas MS Cap Flintglas MS Cap CoolStar •0 0 0 0 0 0 • 0 Flintlastic GMS Premium Flintlastic Premium GMS CoolStar • :•••: • 00000• • . • .0000• Flintlastic GTS Flintlastic GTS CoolStar •• • 000 • • i Flintlastic Premium FR-P Flintlastic FR-Dual Cap,Flintlastic Premium FR-P CoolStar or Flintlastic FR-Dual Cap CoalStar Flintlastic FR Cap 30 T Flintlastic FR Cap 30 T CoolStar Flintlastic GTA Flintlastic GTA CoolStar Flintlastic GMS Flintlastic GMS CoolStar i Flintlastic SA P-Cap FR Flintlastic SA Cap FR CoolStar Flintlastic GTA-FR Flintlastic GTA-FR CoolStar Flintlastic FR-P Flintlastic FR-Dual Cap or Flintlastic FR-P CoolStar Flintlastic FR-Cap 30 Flintlastic FR Cap 30 CoolStar ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A 1. Deck: NC Incline:3 Base Sheet:—Type G2 Glasbase. Ply Sheet:—Type G1"Flintglas" or Type G2 or"Glasbase". Surfacing:—Gravel or slag. 2. Deck:C-15/16` Incline: 1/2 *All joints blocked. Base Sheet:—Two layers Type G2 or"Glasbase Base Sheet"or two layers Type G1"Flintglas Ply Sheet". Surfacing:—Type G3"Flintglas MS Cap". f httpJ/database.ul.com/co-blrffWitemplate/LISEXT/1FRAME(shovipaohtml7name=TGFU.R11656&ccnehortlige=Roping+Systems&objid=1074351881&cfg.. 2122 E i 2/13/2017 TGFU.R 11656-Roofing Systems j 3. Dack:NC Incline: 3 f Base Sheet.s-Two layers Type 15"All Weather/Empire". Surfacing:—Gravel or slag. l 4. Deck: NC Incline:3 insulation:—Polyisocyanurate, mechanically fastened or hot mopped,any thickness. Base Sheet:—Two to five plies Type 15 asphalt organic or Type G2 asphalt glass hot mopped. Surfacing:—Gravel. 5, Deck:C 15/32 Incline: 3 Insulation:—Polyisocyanurate i-in. minimum,mechanically fastened or hot mopped. Base Sheet:—Three plies Type 15 asphalt saturated organic felt(perforated)hot mopped with hot roofing asphalt. ! Surfacing:—Gravel. I! 6. Deck:C-15/32 Incline:3 j Vapor Retarder(Optional):—Type G2 or"Glasbase"or UL Classified vapor retarder. Insulation(Optional):—One or more layers or combination of the following: Polyisocyanurate,perlite, glass fiber or wood fiber, any thickness. Base Sheet:—Type G2 or"Glasbase"base sheet. Ply Sheets:—Two to three layers of Type GI "Flintglas"ply sheet or Type G2 or"Glasbase"base sheet. Surfacing:—Gravel or slag. 7. Deck:C-15/32 Incline:3 Vapor Retarder(Optional):—Type G2 or"Glasbase"or UL Classified vapor retarder. Insulation(Optional):—One or more layers or combination of the following: Polyisocyanurate,perlite, glass fiber or wood fiber,any thickness. Membrane:—Three or four layers of Type GI"Flintglas" ply sheet. •••• • Surfacing:—Gravel or slag. 000000 • • •••• •••••• Incline: 1 •� � • •�• � 8. Deck:C-15/32 • ' ' ' Vapor Retarder(Optional):—Type G2 or"Glasbase" or UL Classified vapor retarder. •••:•• • • • Insulation(Optional):—One or more layers or combination of the following: Polyisocyanurate,perlite,qfts$fiber or%%qpd fLber. • Base Sheet:—One layer Type G2 or"Glasbase Base Sheet". • • ' ' ' Ply Sheets:—Two layers Type GI"Flintglas Ply Sheet". • • Ca Sheet:—One layer Type G3"Flintglas MS Cap.". "'••• •••• ••••• Cap Y YP 9 • • • • 9. Deck:NC Incline: 1/2 •••••• • • • • • • Insulation(Optional):--One or more layers or combination of the following: Johns Manville"ENRGY 3� polyisocyanu&%,ps0te, • ��•• glass fiber or wood fiber,any thickness. • • • • Base Sheet:—Two layers Type G2 or"Glasbase Base Sheet" or two layers Type G1"Flintglas Ply Sheet,•• : •••• • • Surfacing:—Type G3"Flintglas MS Cap". •• 10. Deck:C-15/16* Incline: 1/2 i *All joints blocked. Insulation(Optional):—One or more layers polylsocyanurate, 2-in. minimum,wood fiber, 1-in. minimum, perlite,3/4-in. minimum, glass fiber, 15/16-1n. minimum. Base Sheet:—Two layers Type G2 or"Glasbase Base Sheet"or two layers Type G1"Flintglas Ply Sheet". Surfacing:—Type G3"Flintglas MS Cap". 11. Deck:C-15/32 Incline: 3 Insulation(Optional):—Any thickness,one or more layers or combinations(optional of"Hy-Therm AP", "Hy-Therm TAPERED","Hy- Therm COMPOSITE", "Celo-Therm""HY-Tec(Energy-LOk)","TRI-Star",wood fiber or glass fiber, mechanically fastened or hot mopped. Base Sheet:—Type 15 asphalt organic felt, or"Glasbase Base Sheet",nailed or hot mopped. Ply Sheets:—Min three plies Type 15 perforated asphalt organic felt,"Flintglas Premium Ply Sheet Type 6","Flintglas Ply Sheet Type 4",hot mopped. Surfacing:'—Gravel or slag. 12. Deck:NC Incline: 2 Insulation(Optional):—Any thickness,one or more layers or combinations(optional)of"Hy-Therm AP", "Hy-Therm TAPERED", "Hy-Therm COMPOSITE","Celo-Therm","HY-Tec(Energy-LOK)",wood fiber or glass fiber, mechanically fastened or hot mopped. Base Sheet:—Type G2 or"Glasbase Base Sheet",Type G1"Flintglas Premium Ply Sheet Type 6"or"Flintglas Ply Sheet Type 4". Ply Sheet:—Minimum one ply Type GI,"Flintglas Premium Ply Sheet Type 6" or"Flintglas Ply Sheet Type 4",hot mopped. Surfacing:—Type G3 cap sheet,"Flintglas MS Cap",hot mopped. 13. Deleted. 14. Deck: NC Incline: 1 Insulation:—Polyisocyanurate, polyisocyanurate/perlite,phenolic or urethane, any thickness,hot mopped or mechanically fastened to place. httpl/database.ul.com/Cgi-bin/XYVAemplateJLISEX r/1 FRAMEtshmipage.html?name=TGFU.Rll656&ccnshortHUe=Roofing+Systems&objld=10743519818�cfg... 3/22 • Florida Building Code 5th Edition (2014) High-Velocity Hurricane Zone Uniform Permit Application Form $ ctlon ® (112m Sloped,Roof ftsLern Roof-System Manufacturer:_ Notice of Acceptance Number: N (-o 03 19 • ®� Minimum Design Wind Pressures,if Applicable(From RAS 127 or Calculations): P1: P2: ) .,.. P3: — Maximum Design Pressure From the NOA Specific S Stam : II + I Method of the attachment I l� � 1 LOO foes 000000 0 :00 S#eep Slotted Roof System Description;:::• :.. .� . . 0.000. :000 000 . .. .. .... ... .. *a Pee YYY �w b ype Underlayment• •• •• Roof Slope: nsulatibn: :12 Aire Bomar: Ridge Ventilation? astener Type iii Spacing: dhesive Type ype Cap heat: oof Covering: �AM�-� Mean Roof Height: Type&Size Opip Edge: 4e Florida Building Code 5th Edition (2014) High-Velocity Hurricane Zone Uniform Permit Application Farm Section E jTlle Calculatlonssl For Moment based the systems,choose either Method i or 2.Compared the values for Mrwlth the value's from Mf*.if the Mt values are greater than or equal to the Mr values,for each area of the roof,thea the 610 attachment method is acceptable. Method1"Moment Based Tile Calculations Per RAS 127" 2, , C� —Mgt Mrx q i�� NOA All —,Mg: A NOA lyk NOA A* Method 2"Simpllfled Tile Calculation Per Table Below" Required Moment of Resistance QQ From Table Below 321-2 NOA 1►t Mr Required Moment Resistance* Rco 81ope Roof 8 ght 15' :t0' q29A 30' 44`. 2 363 • • 3.12 A6:12- 28A 303 311 2!376 211, •� ,�• �•• •� 12 24 .9 • • ... • 000.00 0000 •.• . *Must be used in coni unetton with a list of moment based tate systems endoreed•by the •• . 0001:0 • Braward County Board of Rules and Appeals. :00:0: • For Uplift.based We systems use Method 3.Compared the values for F'with fhe �••••• • 0000. values for Fr.N the F'values are greater than or equal to the Fr values,forAci •••• � • area-of the roof,then the the attachment method is acceptable. •• Method 3"Uplift Based Tile Calculations Per RAS 127" (PIs x l: a x w:¢___._3--W: x cos 8:—- Fj: NOA Fr wt a _ J—W: x cos 6: Frz`e, NOA F' (Ps= xis _ x w:=_)—w: x cas 8: = Frg: NOA F' Where to Obtain Information Description Symbol Where to find DQSMWsmre710203 RAS 127 Table I orbyaa en&ectft afl*. prgwcdby WGRonASCE 7 Meas RoefHel t H Job Site Roof g ob Site A NOA R anent due tOCiOft ML NOA AftachmedReAftm Mr OA ?Aft=MomratResiftt Mr Calailated dmum F' 907A R 11 F. Cal Aveaa emle c NOA Tile DIMMAOM 1= IZ w=wldtitmm ckul Allaoumustbo m to the Butt atdw time of Mina 1%Wd 1I-DARE COUNTY MIAMI, PRODUCT CONTROL SECTION 0 . 11805 SW 26 Street,Room 208 DEPART>IENT Or,REGULATORY AND ECONODIIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamldade.aov/econoEiiy Eagle Roofing Products LLC 1575 East C.R.470 Sumterville,FL 33585 SCOPE: This NOA is being issued under the applicable miles and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modiJyrgr suspend the use of such product or material within their jurisdiction. RER reserves the right tp revQke this%GQqAthnce, ...Y . if it is determined by Miami-Dade County Product Control Section that this product or materihL01s.'to meet the.. requirements of the applicable building code. •••••• •• see*** This product is approved as described herein,and has been designed to comply with the Florida lr3Wding Code* •�; including the High Velocity Hurricane Zone of the Florida Building Code. 009800 •• • ' DESCRIPTION.Capistrano Concrete Tileas so . LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,cW,,Iffile and folldwing . . . ...... statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. •....•• • RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been xio®lange ' in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miatrri--Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No.15-0223.20 and consists of pages 1 through 7. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.:16-0314.08 MIAMI-DADE COUNTY= ENpiration Date: 10/05/21 Approval Date: 06/16/16 Page 1 of 7 ROOFING ASSEMBLY APPROVAL CatesRoofing Sub Category: Roofing Tiles Material: Concrete 1.SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in SuintervIlle,FL and described in Section 2 of this Notice of Acceptance. For use in locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2.PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description Capistrano Concrete Tile Lenght= 17" TAS 112 High profile concrete roof tile. For direc$4eak or Width=12'/4" Type 1 a battened nail-on applications.••• •-•• •••••• Thickness=%x" Class HI •• 0000.• •. • .00.00 Trim Pieces Lenght=varies TAS 112 Accessory trim,clay roof Zipg%for use at lips, • Width=varies rakes,ridges and valley tenVi��ions. •""• varying thickness Manufactured for each tile•RaO. •.• ••,•. •....• . • ••�• 0000• • 00 of 0000 0000.• • ••••r, • • • • • • 0,000: 0000•• • • . 4000 • • w • 06 NOA No.:16-0314.08 Expiration Date: 10/05/21 MIAMMADH COUNTYM Approval Date: 06/16/16 Page 2 of 7 f 2.1 EVIDENCE SUBI'IITTED: Test A e� Test Identifier Test Name/Report Date PRI Asphalt Technologies ERPF-001-02-02 TAS-112 Aug.2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102& 102(A) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108(Nail-On) Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108(Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs.smooth shank nails The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering,Inc. TAS 101(Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering,Inc. TAS 101 (Mortar Set) The Center for Applied 25-7094-(3,6& 9) Static Uplift Testing w Oct. I• see*:* • Engineering,Inc. TAS 102 •• • ••• • The Center for Applied 25-7120-(1 &2) Static Uplift Testing •••;••Nov.1994 ••••'• Engineering,Inc. TAS 102 """ ' wwww w• • • • The Center for Applied 25-7183-(3&4) Static Uplift Testing •....'Feb. j99�.' **:owe Engineering,Inc. TAS 102 w w&w w e V•• *000* The Center for Applied 25-7214-(3,4,&7) Static Uplift Testing •:*O:March,'f 995 '"'0 • : Engineering,Inc. TAS 102 • • • s • •wwww• The Center for Applied 25-7804-4 Static Uplift Testing j •••Sep• ••• Engineering,Inc. TAS 102 •• ••• ' Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998'* Testing Services TAS 101 Celotex Corporation 520191-2-1 Static Uplift Testing March 1999 Testing Services TAS 101 Walker Engineering,Inc. Calculations Aerodynamic Multiplier Sep.2006 ATL of South Florida RT 1211.02-15 TAS-112 12/17/15 NOA No.:16-0314.08 Expiration Date:10/05/21 MIAMFM couNrr Approval Date: 06/16/16 Page 3 of 7 Y 1 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 shall be required,refer to applicable Building Code. 3.3 Applicant shall retain the set-vices of a Miami-Dade County Certified Laboratory to performs quarterly test in accordance with TAS 112,appendix W.Such testing shall be submitted to the Miami-Dade County Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable Building Code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. sees 4.2 Data For Attachment Calculations • • • 0000 0000•• •• 0 e •s• • • Table 1: Average Weight(W)and Dimensions(I x w) 669:60 •• •••••• 0000.. .0000. Tile Profile Weight-W(lbf) Length-1(ft) ••••JlVidthll6�ft1 • see* • es 00000 Capistrano Concrete Tile 10 1.417 1.04:@G* ""' .. .. 0000 sees:* Table 2: Aerodynamic Multipliers-A ft3 •• 0000.. Tile A(ft3) A ift3) ••••• . Profile Batten Application DlreLN2ek fppllS&on ;•••• Capistrano Concrete Tile 0.300 0.277 • Table 3: Restoring Moments due to Gravity-M ft-Ib Tile 3":12" 4":12" 5":12" 6":12" Greater than Profile 7":12" Capistrano Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Concrete Tile Deck Deck Deck Deck Deck 6.68 6.99 6.57 6.88 6.44 1 6.73 6.28 1 6.56 6.10 1 6.38 NOA No.:16-0314.08 MIAM6DADECOUNTY Expiration Date:10/05/21 Approval Date: 06/16/16 Page 4 of 7 t Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132"plywood) (min.19132"plywood) Capistrano 2-10d Ring Shank Nails 28.6 41.2 19.4 Concrete Tile 1-10d Smooth or Screw 5.1 6.8 2.8 Shank Nail 2-10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1#8 Screw 20.7 20.7 18.1 2 418 Screw 43.2 43.2 29.8 1-10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1-10d Smooth or Screw 29.3 29.3 24.0 Shank Nail Eave Clip) 2-10d Smooth or Screw 27.6 27.6 36.6 Shank Nails Field Clip) 2-10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) . . 9999 9999.. 2-10d Ring Shank Nails' 33.1 48.1 1. Installation with a 4"file headla and fasteners are located a min.of 2'/"from head of tile.•9.6 9 6 9999.. 9999.. Table 5: Attachment Resistance Expressed as a Moment Mf(ft-i • 9 .. 9 for Two Patty Adhesive Set Systems Tile Tile Application MiYt"Attacjognt Profile ..JWWstance . Capistrano Concrete Tile Adhesive 29.32 . 9999:. .9096. 1 See manufactures component approval for installation requirements. .. ... 9999.. 2 The Dow Chemical Company TlleBond Average weight per patty 10.7 grams. ICP Adhesives Polyset AH-160.Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment-Mr(ft-lbf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Capistrano Concrete Tile ICP Adhesives Poiyset®AH-160 66.53 ICP Adhesives PolysetO AH-160 38.74 3 Large paddy placement of 63grams of Polyset&AH-160. 4 Medium paddy placement of 24grams of Polyset®AH-160. Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-ibf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Capistrano Concrete Tile Mortar Sets 24.5 5 Tile-Tito Roof Tile Mortar. NOA No.:16-0314.08 MIAMMADEC-09NTYW Expiration Date: 10105/21 Approval Date: 06/16116 Page 5 of 7 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below),or following statement:"Miami-Dade County Product Control Approved". L7EI, EA GL 0 �9 FL0[IDA (LOCATED ON UNDERSIDE OF TILE) •••• • • 00.00• 00.00•0 •. • • 0000• • OR ' ' .... ...... .. . .. ....•. • . . .... • .. •0.0• EAGLE FL : : ••::" • • •••• • . . . (LOCATED ON FRONTSIDE OT TILE) . ...... .. . 0000 00 CAPIsTRANO CONC FTE ROOF TILE LABEL,SUNiTERVILLE PLANT 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by AHJ or applicable Building Code in order to properly evaluate the installation of this system. NOA No.:16-0314.08 MAMI•DAUECOUNTY Expiration Date: 10/05/21 FAVV.O , Approval Date: 06/16116 Page 6 of 7 PROFILE DRAWING NAIL ROLE o. '7,fin .+.y. .S BR'S- ��'y. ''�S"S° m • a $yam ?row • *•A•• •••1•• • • • • i • 17 as 'y,0. •••••• • • � • • •••••• d.L til. d� � • • ^ •• • • • 'sa • • • • 'sem ��. a •i'•• • ••• ••••• N, l �$}���7t/'';{ • • by ar �ri • e"' y • • • • 0000 ••••• • • • • • 00 CAPISTRANO CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.:16-0314.08 MIAMhDADECOUNTY Expiration Date: 10/05/21 �Fj...,xjlu� Approval Date: 06/16/16 Page 7 of 7 MIAMI, .y, t1IIAD9I-DADE COUNTS PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULA'T'ORY AFFAIRS(PERA) 11805 SW 26 Street,Rown 208 BOARD AND CODE ADIMISTRATION DIVISION Mianti,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) iiv.miamidade.eoy/I,)cra Owens Corning One Owens CorningParkway Toledo,OR 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.Tile documentation submitted has been reviewed and accepted by Mianii-Dade County PERA-Product Control Section to be used in Miami Dade County and other areas inhere allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade Count),)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify or suspend the use of such product or material within their jurisdiction. PERA reserves the right to rgvoke d1i;...• ...... acceptance, if it is determined by Miami-Dade County Product Control Section that this prodNA&blaterial,fv*L%to .' meet the requirements of the applicable building code. •••••• •• •••••• This product is approved as described herein,and has been designed to comply with the Floridt9130ding Code ;....: including the High Velocity Hurricane Zone of the Florida Building Code. ." 0000 . .. 0000. DESCRIPTION: Weatherlock*Specialty Tile& Metal Underlaymen# • .. .. 0000. 0000.. . 0.000. . . LABELING: Each unit shall bear a permanent label with the Tnanufacturer's name or logo,dity,•state and following ....:. 0000.. statement: "Miami-Dade County Product Control Approved",unless othemrise noted herein.: .• •••• RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no Lunge in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes sliall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in.advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOAH!09-0908.06 and consists of pages I through 3. Tile submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0309.03 MIAMIDADECOUNTY Expiration Date: 07/31/17 Approval Date: 07/05/12 Page I of 3 Y ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Weatherlock® 36"x 33.3'rolls TAS 103 SBS self-adhering asphalt sheet material with a Specialty Tile& 36"x 66.7'rolls white or green glass re-enforced polyester Metal Underlayment surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brenwood,NH ..•b EVIDENCE SUBMITTED: ':060 0 00•' .•..•• Test Agency Test Identifier Test Naurc/Report aste ...... . . ...... Underwriters Laboratories, Inc. R .0 /14610 Follow up Service ...:.. 28/02 . TRT-Arcon,Inc. 02-012 TAS 103 .• •. :`927M/02 • 0000 • .. ..•.e PRI Asphalt Technologies, Inc. NEI-006-02-01 TAS 103 •• •• 04LI/02 ••:••• PRI Asphalt Technologies,Inc. NEI-008-02-01 TAS 114 (H) 0. 00 •0 89/30/02 so**:* PRI Construction Materials NEI-045-02-01 ASTM D 4798&ASTM G =:': 08/08/07 Technologies,LLC. NEI-053-02-01 ASTM D 4798&ASTM G 1055 :.415b1/08 000000 NEI-076-02-01 TAS 103/A STM D4798:..••; 921t4/1 I •••• APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated,new constniction Deck Description: 15/32"or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of ASTM D 266 Type II or ASTM D 2626 with a minvnurn 4"side lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the laps and two staggered rows 12"o.c. the field of the roll. Membrane: One or more plies of Weatherlock`g'Specialty Tile&Metal Underlayment with a minimum 4" side tap and 6"end lap. Place the first course of membrane parallel to the cave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with Weatherlock®Specialty Tile&Metal Underlayment is acceptable. Surfacing: Approved for Adhered Roof Tile,Mechanically Fastened Roof Tile,Metal Roofing,Wood Shake&Shingles,and Asphaltic Shingle assemblies. NOA No.: 12-0309.03 MIAM�•DAOEc WNTY Expiration Date: 07/31/17 Approval Date: 07/05/12 Page 2 of 3 LINIITATIQNS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Mininnun deck requirements shall be hi compliance with applicable building code. Weatherlock® Specialty Tile & Metal underlayment shall be installed in strict compliance with applicable Building Code. 3. Weatherlock Specialty Tile &Metal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. Weatherlock° Specialty Tile & Metal underlayment shall not be applied over an existing roof membrane as a recover,but may be applied over roofing Base/Anchor sheet underlayment. 5, Weatherlock® Specialty Tile & Metal underlayment shall not be left exposed as a temporary roof for longer than 90 days of application. 6. The standard maximum roof pitch for Weatherlock'Specialty Tile&Metal underlayment shall be 6:12 when tiles are loaded directly to the Weatherlock' Specialty Tile & Metal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 00*0 S. Tiles shall be stored on battens on roof pitches greater than 6:t 2". • • •••••• •••••• 9. Weatherlock® Specialty Tile & Metal underlayment may be used with any approved!'Foof coved ijoVotice of 0. Acceptance listing Weatherlock Specialty Tile& Metal underlayment as a compouuencN t.if an asseulubty in trie • Notice of Acceptance. If Weatherlocko Specialty Tile&Metal underlayment is not listq.(L"requesluia3„be made•••; to the Authority Having Jurisdiction (ABJ) or the Miami-Dade County Product ContrUPAplartme4t foc:lfpproval... provided that appropriate documentation is provided to detail compatibility of the prodsoisi r hid uplikvegistancep:••• and fire testing results. 00000 •••• ••••;• 10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose McQking panelj. SwerA..;. the deck thoroughly to remove any dust and debris prior to application. 0000* . 11. When applying the membrane in the valley,start at the low point and work to the high pouit,rolling tfit vis'nibrane • from the center ouhvard in both directions. For ridge applications, center the membrane and roll from t1ue center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Weatherlock Specialty Tile&Metal underlayment shall be applied over the underlayment. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMMADE CQUN VQMFJ22;U4111 END OF THIS ACCEPTANCE MIAMt•DADECOU�IIY NOA No.: 12-0309.03 � Expiration Date; 07/31/17 NEE= EMEW Approval Date: 07/05112 Page 3 of 3 i MIAMI-DADS COUNTY M1AM1' PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTl11ENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) wimmiamidade.eoy/economy ICP Adhesives and Sealants,Inc. 12505 NW 44'x'Street ! Coral Springs,FL.33065 ! SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (hi Miami Dade County)and/or the AM(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted naeflmer,the manufacturer will incur the expense of such testing and the AHJ may inuuediately revoke,modify-gr suspend-itke use •....0 of such product or material within their jurisdiction. RER reserves the right to revoke this aecepta>Lce,;f:t is • determined by Miami-Dade County Product Control Section that this product or material rails td blM the rec"rements •••••• of the applicable building code. •0 0 0 0 '•• '• .... This product is approved as described herein, and has been designed to comply with tiler Ng4da Build tug.Code ••••• including the High Velocity Hurricane Zone of the Florida Building Code. 000. see* 000000 0000 0000.. ...... DESCRIPTION:ICP Adhesives Polyse&AH-160 • 0000.. . 1 a LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,oiW,, nate and.foll%ving :0000: statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of t1lis NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the i materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done j in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and t shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.:17-0322.03 MIAMI•DADECOUNTY Expiration Date: 05/10/22 12112Approval Date:04127/17 Page 1 of 11 { i i 7 i ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof the adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc,as described in this Notice of Acceptance. For the locations where the design pressure requirements,as determined by applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP Adhesives Polyset'AH-160. I PRODUCTS MANur-ACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyqethppne foantViNosive •••••• Polyset'8AH-160 • ICP Adhesives Foam N/A Dispensing Equipment •••••• •• ...... Dispenser RTF1000 ""•• • ICP Adhesives ProPack® NIA Dispensing Equipment • •••• •• ••••. ••:••: 30& 100 •• •• •••• •••••• PRODUCTS MANUFACTURED BY OTHERS: • Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NO%-,0(Ji list itlech.%pt •••• resistance values with the use of ICP Adhesives Polyset'a'AH-160 roof tile adhesive. •.; i MANUFACTURING LOCATION: L 1. Tomball,TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.61bs./ft? Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft' Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @ 40'F.,2 weeks +6.0%Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.:17-0322.03 j M AMI-DADEcouNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 2 of 1 I EVIDENCE SUBMITTED: Test Ageney Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 I 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 i 25-7492 SSTD 11-93 12/12/95 F Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ranntech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/161954 . . 9000 640669 Trinity Engineering 7050.02.96-1 TAS 114 ••• 03/14091•• I P36700.04.12 ASTM D 1623 •• 04/18f1.2 •••• • P39740.02.12 TAS 101 02/21/12 6 9 6 4 TAS 123 ��•�. .�•. •••�4 I 9999.. . 99:99' Celotex Corp . .Testing Services 528454-2-1 TAS 101 4 •• 10/23/4$ 6•• 528454-9-1 44•,•• • •• 528454-10-1 • . . . . 9999.. 520109-1 TAS 101 6 12/V98•• 6 520109-2 •• ... 449499 520109-3 ••0 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 i LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyseta AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset!'�AH-160 roof the adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. i NOA No.: 17-0322.03 MIAMt•DPROVED couNTY Expiration Date: 05/10/22 Approval Date:04/27/17 Page 3 of 11 i I i i 1 ' INSTALLATION: 1. ICP Adhesives Polysef'$ AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset,AH-160. 2. ICP Adhesives Polysets'AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polysef€'AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive i attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset'AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants,hrc.ICP Adhesives and Sealants,Inc.shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A"component and the"B"component shall be maintained4xitween 1.0-1.15(A): 1.0(B). 0000 0 0 0 0.0 6. ICP Adhesives Polyset'AH-160 shall be applied with ICP Adhesives Foam Dispenser RTfjPPQ or IOPe 0 ••• Adhesives ProPack"30&100 dispensing equipment only. 0 0 0;0 0 • 7. ICP Adhesives Polyset' AH-160 shall not be exposed permanently to sunlight. •••• •• ••0 0 8. Tiles must be adhered in fresh/ applied adhesive.Tile must be set within 1 to 2 minutes 0 0 0• P Adhesives 0 • � Y pp 2��1;It's �... ..... � Polysef' AH-160 has been dispensed. 0000000 0.. 9. ICP Adhesives Polys&AH-160 placement and minimum patty weight shall be in accor4zPft'%rith the • Tlacement Details'herein. Each generic tile profile requires the specific placement noted liereitl. ;••�;0 •••••• i P f k NOA No.:17-0322.03 MU MMADECOUNTY Expiration Date: 05/10/22 � Approval Date:04/27/17 Page 4 of 11 I i I i I Table 1:Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Mhflhnum Paddy Gram Area Weight Eave Course-Flat,Lore,High All Eave Course 17-23 sq.inches 45-65 Profiles Flat,Low,High Profiles #1 17-23 sq.inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 I Flat,Low,High Profiles #3 Two Paddys:8-9 sq.inches at 12 grams per paddy head of tile 9-11 sq.inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq.inches each bead • • 0000 0000.. 9 Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches "51 ams untier pAn09 000- •••• • 0000 .. •0000. 0000 . 90 0000. LABELING: 00000. 0000 00000' All approved products listed herein shall be labeled and shall bear the imprint or identifiable mnidgof the ••• •••••• manufacturer's name or logo and following statement: "Miami-Dade County Product Control+NdVe?"or the Miami- •• Dade County Product Control Seal as shown below. :000% 000000. 90000. MMMIDMECOUNW •• • 000 0 0 0 • 0 •9 BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. f i E i NOA No.: 17-0322.03 MIAM6DADECouNTV Expiration Date: 05/10/22 mix SIM Approval Date:04/27/17 Page 5 of 11 i i 1 I ADHESIVE PLACEMENT DETAIL# 1 FhlltluoL®h plasticceraent Pamytimaeath1w) Flat/Low Profile Tile {tiS'KSitoQuitetllh a.• -''••,, :=- r'' hi U?Avrt yM4nt ,,54 "'�- `` �� 1. Starting at the eave course,apply a minimum 2" I (50.8 min)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the Overlock ,q,. �-,''` ;•. of the tile being set. Ilatternupttonal eaveeoone -' 2. Continue in same manner.Insure approximately 17 Ilkt; (109.7 cm2)—23(148.4 cm2)square inch adhesive contact with the underside of the tile. Fascia ..�4.••,, X_ fir: +{• .,,yt,� fry•,s••_ f�s ---------------- Medium Profile/ Double Pais Tile "....' • Heil throughpl.akcetnent •• • • Itvhenrctiuhe� __ P+ddy 1(;►neathrilrl 1• Starting at the eave coursel Q19 lepa minim]ll k •e•.i• All ,.�= i I (50.8 nun)x 10"(254 mntj x F&125.4 mm)foam • paddy onto the underlaynVfi?P84tione¢ej shgwn • under the pan portion of the tite'closest to the •••+• ovcrlock of tile tile being gct:": ;"• ••••• . t01A.i••.., (}� '11� 'sus '-/��* • � d 2. Continue in samc mannerMserraapproximately 17 ®attetu optional i� �`..'', `` ,�'.• ��.y,m • • • •••••• (109.7 cm2)—23(148.4 cjl2)s$uare incl:edgesive `�- o ' e nP •-'' contact with the underside th tile. •••••• Closure Uwe CourseFascia 's Nall lhroughplwsllctq�poivY.-.y _paddyl8vnsaehTlldl High Profile/Single Pan Tile (when requhed) f Starting at the eave course,apply a minimum 2" j 1'=,;v f••.,.,��.,, (50.8 nun)x 10"(254 nun)x 1"(25.4 mann foam ,•. ,,. , __• .., -�• r '•...,� paddy onto the underlayment positioned as shown r wh>r' `�:;,t••- a ' under the pan portion of the tile closest to the -..,� ._ :;,;,� ��`�••.,, Overlock of the file being set. 2. Continue in same manner.Insure approximately 17 Battens optionalr ' '`:' o ; , �` (109.7 cm2)—23(148.4 cm2)square inch adhesive Fr >= contact with the underside of the tile. s`� Eave roursc E_.•�:>��•-.•-• '`�,'� ��_/"'pascta ►.f• i _ Weephole Eati+e closure Iain'"-.-..'� •A�]in.=,-`~'�ss'-`=� ''��Urlpedpa NOA No.:17-0322.03 MIAMI•nauecouNT1 Expiration Date: 05/10122 ► Approval Date:04/27/17 Page 6 of 11 i ADHESIVE PLACEMENT DETAIL#2 Istetilhreuyhpia{titwMil"t Fda�Ylaen••u,ra.t Flat/Low Profile Tile twh attcvraIndiy Starting at the eave course,apply a minimum 2"(50.8 ured moss �•� : '-•, mm)x 10"(254 rani)x 1"(25.4 pini)foam paddy onto the widerlayment positioned as shown wider the strengthening rib of the tile closest to the overlock of �:In, •:���,, ,�,�.- .., the file being set.Insure approximately 17(109.7 cm-) 23(148.4 cin)square inch adhesive contact with the underside of the tile. Fawcoutwe 2. At the second course,apply a minimum 2"(50.8nnn) > .. 101" -.`` "` -: ',7<Fasda x 7"(177.8 mn1)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the file two odofnio__ `'� `err.' s' being set. 3. Continue in same Manner.Inure approxidi;W0y t0" ••••• (64.5 cm2)-12(77.4 cin')square i&li adhesivre• contact Avith the underside of the tile. •••• ....:. tVailthro�ghpiatticcement Medium Profile/Double Pan Tine•• • •• •• ••• 00:00:• • •••• ••••• (whenrequiredl • Paddy Ieoneath lite) 1. Starting at the cave course,aj)311 rd minimiiM 2"(50.8 �•••�• na..ldymr.,,�.r✓ v .s =``" nun)x 10"(254 nun)x 1nu;)foam palddy •. ". "`-" M to the underla ent positioned as slio,.; iirtl 6-the ••••'• pan portion of the tile closest Yg di,roverlock,of the •••• the being set.Insure approximately 17(109.7Cnj2)— in. c �`s,•.r•2tn_ f.�:�� >,, -;'�:,� 23(148.4 cm2)square inch adhesive contact with the underside of the tile. —Ile 2.8 2. At the second course,apply a minimum 2"(50.8nnn) x 7" 177.8 mni x 1" 25.4 imn foam paddy onto the "�.." �,,,�,.,�• F,,,•cl•,..o underlayMent positioned as shown under the pan Rog Ctaws portion of the tile closest to the overlock of the tile { being set. I 3. Continue in sante manner.Insure approximately 12" (77.4 cm2)- 14(90.3 cm)square hich adhesive contact with the underside of(lie tile. (Instructions continued on neat page) NOA No.: 17-0322.03 MIAMWADEcouNTY Expiration Date: 05/10/22 ' Approval Date:04/27/17 Page 7 of 11 i i 1 ADHESIVE PLACEMENT DETAIL#2(CONTINUED) NaIItArOuyhprasdccg �' Faddprpvn«i11]Tito) High Profile/Single Pau Tile twteniequlrod) 1. Starting at the cave course,apply a minimum 2 (50.8 mm)x 10"(254 nun)x 1"(25.4 mm)foam paddy onto the undcrlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set.Insure approximately 17(109.7 cm)— �-1 7`" i„ �:'-. . f ,, 23(148.4 cm2)square inch adhesive contact with the ,,, 11atensaptlenal h`'y] Q,o< underside of the tile. j 01 2. At the second course,apply a minimum 2"(50.8nun) � Env e Covet—"` ,r feseia x 7 (177.8 nun)x 1 (25.4 nun)foam Daddy onto the underlayment positioned as shown under the pan �, �,�' - `.'''� o�rEea er4s�. portion of the tile closest to the overlock of the tile lu"' � . P 9 being set. 0000 E 0000 .sees. 3. Continue in same manner.Impteagproximgte1%j7" •• (109.7 cm2)- 19(122.6 cmZ rgle.inch 4W%i* .•..;. contact with the underside of tJwZ1W. 0000.. 0000 .. 0000 .. 0000. i 0000.. sage.. 0000.. 0 . e Osseo. i i ! I I i NOA No.: 17-0322.03 MAbIMADECOUNW Expiration Date: 05/10/22 1 Approval Date:04127/17 Page 8 of 11 i i i ADHESIVE PLACEMENT DETAIL#3 Nall through plastic cement PaddyMetweenti)es) (whenrequtradl 1. On the cave course only,apply a minimum 2"(50.8 sattensoptional ° min)X 10"(254 nun)x 1"(25.4 nun)foam paddy I . Piddylunderdle) onto the underlayment positioned as shown,under y single paddy the strengthening rib for flat tile or under the pan V oatopottde portion of the the for low or high profile tile closest to the overlock of the tile being set.Leave I 4x41n.S approximately 4"(101.6 imn)up from the eave in to �dy °A ., edge free of foam to prevent the expanded adhesive on mt dayrn 2:ain. from blocking the weep holes. Insure t ' approximately 17-23 inZ(109.7-148.4 civ2)of toyadhesive contact with the underside of the tile :- ,�`�. Fascia - --EaYeClosute 2. Apply a 4"(101.6 nlln)x 4e(101.6 mtnn)x 1 (25.4 )ntn)foam paddy onto the underlayment just below i Flat/Low ProflleTlle the second course line positioned foairio tly. under the strengthening 61)for%at tile,&ANder the" Nail throughplasticcement Single paddyundertUe pan portion of the tile,closest to the utt[leerlIN for '(when required) . PaddytbetweenWas) the second course file to bt:�netalled. Insu�e • approximately 8-9 in'(5 cm2 cma)gJadtesive :e99% Battens PA lundertilei contact with the undersidep[4>etile. • .. **:see . . I00000. 0000 0000. s�o •• •• 0000 00.00. • onfo�t�til�e �'`-- (Insb•uctions conlbu(ed on Tref"Pa.9 ►) P - • • • • 0000•• 2x4 un eriayment •• • 000 • • 0 0 •o fern •' lin. •Eau Closure Eave Course Fascia Medium ProflleTile P 1 i s NOA No.:17-0322.03 P11AMMADECOUNT1f Expiration Date: 05/10/22 Approval Date:04/27/17 Page 9 of 11 I I 4 • ADHESIVE PLACEMENT DETAIL#3(CONTINUED) Nalithrougplasticce SRI epaddyundert(le (when requGedl 3. Also apply a 2"(50.8 nun)x 4"(101.6 nun)x 3/4" Paddy(betweentlles) (19 nun)paddy on top of the cave course tile Battens _ surface as shown,on top of the strengthening rib optional _ Paddy(undert(lel for flat file or on top of the pan portion of the tile, closest to the underlock of the first course of tile. i single <i onu Install second course of tile.hisure approximately ymen 4: 9(58.1 cm)- 11(71 cm2)square inch adhesive f 741n. •��ti4 ti+ contact with the underside of the tile at the overlap s6�te p��ty 274 '=�" and 7(45.2 cm2)-9(58.1 cm2)square inch topoieolne .��'�. — adhesive contact with the underside of the the at -', the head of the tile.Continue in same manner. Eave Course— �``� } Fasda _ Weephole tOln. tin. EaYedosure Odp edge 0040 • • •000 .0000• 00 High ProflleTlle •.•• 0 • ••••• •• . I00.. .. . 0000•• 0000•• • • • 0000•• • • 0 • • 00.0 06.46 1 • • 0000•• .:'000 0000• •• •• 0000 •000.0 • ••000• • • • • • •0000• •00.0• • • • • • • • • •000•• i i NOA No.: 17-0322.03 MIAMe nAOE couNTv Expiration Date: 05/10/22 r Approval Date:04/27/17 Page 10 of 11 i 1 i t I i i A . s ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan)Tile I. Starting at the eave course,apply a minimum 2" JJ t)Place aenough hthepa Mile. hlova65to70sq.in. Steappiquiredllcatlons 50,8 ntin x 10" 254 min x 1"(25.4 mm)foam j In contact with the pan tile. when required) ( ) ( ) ( ) , 2)Tum covers upside down.Place adhesive In paddy onto the underlayment positioned as I to t In.from outside edge ofcovertile. shown under two adjacent pan tiles.Support eave Then Install the tile.Ensure 20 to 25sq.bucontactarea. .° tiles from rocking until adhesive has a chance to Underlayment cure. 2. Continue in same manner bringing two pan .:'• , courses up toward the ridge.Insure • - �% ='" ` , approximately 65(419.4 C1)12)—70(451.6 cm) square inch adhesive contact with the underside -' Sheathing of the pan tile. •••• Eaveclosus t-' • • t (motarshown) 3. Turn covers upside down exl!Qsing the fidderside '00000 Weephole Fascia Board of the tile.Apply a minimum r'(25.41141)Sc 10" '• •,••• • • • •+•••• (254 mm)bead of adhe�ov"Wirectly on Elie inner • Remove top pardon oi the eave course cover dle.Abuttosecond course of edge of each side of the Sgve�tile.Leave •••••• pantiles.Ensure eave end ofpan and cover tiles are flush ateave line. „ ' ., •• • • • approximately 3/4 (19�•te 1 (2f.4 Vp) ••s•• ! Two Piece Barrel-High Profile Tile from the outside edge gfJbe.14c,imvar4.4%e of ••:••• foam to allow for cxpansidrj. *0:0 •••••• 4. Turn cover file over after foalri is ap t.lied and *so*:* ••... j place onto pan tile course.l myre a n9immum of •••• 20(129 cm2)-25(161.3•em2)gsquarehick : • • contact area on each side of the cover the to the pan file.Continue in same manner.Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. S. When additional nailing is required,T'(50.8 nun)x 4"(101.6 mm)nailers or the tie wire system using galvanized,stainless steel,or copper wire and compatible nails may be used. i t i END OF THIS ACCEPTANCE i NOA No.: 17-0322.03 t MUIMI•DADEcouN7Y Expiration Date: 05/10/22 Approval Date:04/27/17 Page 11 of 11 t r o -: edera Phone 954-784-2941 800-848-1919 &TESTING INC. Fax 954-784-7875 250 SW 13th Ave Pompano Beach,FL 33069 fed-eng.Com Dated: Monday,August 28, 2017 Order Number 17-PBR-295 Paul Bange Roofing 7000 SW 21 st Place tt Davie, Florida 33317 RE: TAS-106 Tile Uplift Test Proposed Roof: Benson Residence j r7 Permit#: RF-5-17-1398 361 NE 102nd Street Miami Shores, FL 33138 In accordance with your authorization, Federal Engineering & Testing, Inc. has performed Tile Uplift Testing in compliance with Testing Application Standards TAS-106 and the Florida Building Code High Velocity Hurricane Zone on August 26, 2017 at the above referenced project. The purpose of our inspection was to determine the uplift capacity of the roof tiles for the residence at the above referenced project. The subject roof consisted of S-Shaped Concrete Tile Foam Set. The pitch of the subject roof is 4/12. Our field engineer visited the site and conducted 47 uplift tests on the roof tiles.All tests were performed according to the Florida Building Code High Velocity Hurricane Zone and protocol TAS-106 using an Intercomp Scale Model CS200. The following is a summary of results: Field Test Results Test Number Test Location Field Uplift Pull Test Test Results 1 - 9 Corner See Attached Diagram 35±5 Pounds Passed 10 - 29 Perimeter See Attached Diagram 35±5 Pounds Passed 30 - 39 Field See Attached Diagram 35±5 Pounds Passed 40 - 47 Hip/Ride See Attached Diagram 35±5 Pounds Passed All test results were found to be in compliance with TAS-106 and the Florida Building Code The test results are limited to the tested areas. If other roof areas exhibit different conditions, it should be brought to our attention for remedial work. This uplift test is not a roof top inspection. A final roof inspection must be conducted by the building official for approval. The test results presented reflect the condition of the roof system at the time of the test. These results are time and sample dependent since roof conditions are continuously changing due to exposure to the elements. Federal Engineering&Testing, Inc. is an independent third party providing un-biased testing information and results and is not affiliated with our client nor do we have any financial interest in the project or determination of the test results. As mutual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for publication of statements, conclusions or extracts from or regarding our reports is reserved pending our written approval. We appreciate the opportunity to be of service to you at this phase of your project. If you have any questions or comments, please give us a call. It has been a pleasure working with you and look forward to doing so again in the near future. SiAIcerely, Keith LeBlanc, P.E. Federal Engineering&Testing, Inc. Florida Reg:No.59384 Certificate of Authorization#5471 Miami-Dade County Certification#16-0203.07 G • � MIAW Construction Material American Concrete Miami Dade Florida Department Engineering Council Institute County of Transportation V N " -4 J7 mai t . -- _ J.-__ ya _ rQ ° y a=0.1 (w)= 0.1( 42 ') = 4.2 ' a=0.4(h)= 0.4( 15 ') = 6.0 ' Perimeter Dimensions = 4.0 ' Figure R301.2(7)Componet&Cladding Pressure Zones Corner Area: 144 S.F. = 9 tests Perimeter Area: 568 S.F. = 20 tests Field Area: 1288 S.F. = 10 tests Ridge Caps: 155 = 8 tests *All dimensions are approximate' Total Tests Performed: = 47 Test Location Sketch Federal Engineering & Testing Inc. 250 SW 13th AVE Pompano Beach, FL 33069 (954) 784-2941 Client: Paul Bange Roofing Project: Proposed Roof: Benson Residence Test: TAS-106 Tile Uplift Test Project Address: 361 NE 102nd Street (Test location sketch is not to scale) Miami Shores, FL 33138