RC-14-944 (2) INSPECTION RECORD POST ON SITE
Permit C-5-14-944
Miami Shores Village Pew Type:R6S _ ntiai Comtiluction
10050 N.E.2nd Avenue 3` f '
au da
Miami Shores,FL 33138-0000 f` ,' Doff{C=OssifiCatiUn.Afteritjo t
Phone: (305)785-2204 Fax (305)756-8972 Issue Date-9/30/2014
Expires: 03/29/2015
INSPECTION REQUESTS: (305)762-4949 or Log on.at https://bidg.miamishoresvillage.com/cap
REQUESTS ARE ACCEPTED DURING 8:30AM-3:30PM FOR THE FOLLOWING BUSINESS DAY.
Requests must be received by 3 pm for following day inspections.
Residential Construction Parcel#A 132060460660
Owner's Name:GERARDO OLARTE Owner's Phone:
Job Address: 8701-9043 NE 4 Avenue Road Total Square Feet: 320
Miami Shores, FL 33138-
Bond Number: Total Job Valuation: $ 63,000.00
WORK IS ALLOWED MONDAY THROUGH SATURDAY,
7:30AM-6:00PM.NO WORK IS.ALLOWED ON SUNDAY
Contractor(s) Phone Primary Contractor OR HOLIDAYS.
ESR FLORIDA CONSTRUCTION INC (305)812-2716 Yes
BUILDING INSPECTIONS ARE DONE MONDAY
THROUGH THURSDAY. ROOFING INSPECTIONS ARE
DONE MONDAY THROUGH FRIDAY. NO BUILDING
INSPECTIONS DONE ON FRIDAY.
f'Biz'77 -J"13
Vj
vim--. I'� �/� Gal•••a GO1
Y I�
NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED. PLANS ARE READLY AVAILABLE. IT IS
THE PERMIT APPLICANTS RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER
THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO
YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND
POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO
OBTAIN :FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
J
INSPECTION RECORD
4- STRUOTURA
MNTS
INSPECTIONDATE INP INSPECTION DINSPECTION DtiTI= INSP
Foundation � Zonin FinalStemwall ZONING O-IMRough b-
Slab Water Service
Columns 0st Lift2nd Rou h
Columns 2nd Lift TOP Out
Tie Beam Fire Sprinklers
Truss/Rafters Septic Tank
Roof Sheathing Sewer Hook-up
Bucks Roof Drains
Windows/Doors Gas
Interior Framing INSPECTION DATE INSP LP Tank
Insulation Temporary Pale Well "
Ceiling Grid 30 Day Temporary Lawn Sprinklers
Drywall Pool Bonding Main Drain
Firewall Pool Deck Bondm* Pool Piping
Wire Lath Pool Wet Niche Backflow Preventor
Pool Steel Underground Interceptor
Pool Deck Footer Ground Catch Basins
Final Pool Slab Condensate Drains
Final Fence Wall Rough HRS Final r°
Screen Enclosure Ceiling Rough
Driveway Rough PLUMBING COMB-
Driveway Base Telephone Rough
Tin Cap Telephone Final
Roof in Progress TV Rough
M2p in Progress TV Final
Final Roof Cable Rou h
Shutters AttachmenF Cable Final
Final Shutters Intercom Rough
FA
Rails and Guardrails Intercom Final MtQHANIC L.
ADA compliance Alarm Rou h INSPECTION DATE INSP
Alarm Final Underground Pipe
DOCUP/IE Fire Alarm Rough
Soil Beadna Cert I Fire Alarm Final Rough,
Sol;Treatmem.0&4, Service Work With
•c 1oor Elevation Survey Ventilation Rough
Reinf Unit Ma-:s Cert ELECTRICAL COMMENTS Hood Rough
Insulation Certificate Pressure Test
S t Survey Final Hood
Final Survey Final Ventilation
`Truss Certification Final Pool Heater
STRUCTURAL COMMENTS Final Vacuum
r G
FIR
MECHANICAL COMMENTS
INSPECTIONDATE —INS-P-1
Fdnal S inkler
Final Alarm
1 •a' x.iia �¢` t � �+` -'e' '++ 1 tt "'� *'1`+`, a J(r 5 'y^ rt•' �l ��`q� , iY, �+�.�` �{' d, 1��Y *•r^g"„ ,ti ,
fpo 1 H., i rq"�itRf,+ p � _$!. . v• ,.t i �s; �¢ r t � :F `Z-j. v 'f7?F'4-'-`:°S .�^
,` •!, i 1'��.`�P .1 d x @ f� J� 4ap k 4 v,Jd: 4 .C> R ••4�d a,�.} 'N'.. I�'6, r�''�•' I' � �'. �I .,�53•r
� -3y` �cJ'�-. t+�. «?«. �},. '� a ,�ihv '.;•'d�� _ .9_'.�'1blF, "'4`'• .. ,�py,'!`•� "-, '� d" "'- �� ��
''�i•�.�'.. >o --s - � ,c�` • - ;i�.'E1a3•. _ �'rrr '�'-'_`� � - � - I r4, s., q,:d�.�¢ �E`,',:ak"�,.r. ar`ti.?f' a,�, ,-�yi' .;e
_ �,✓ i`, r^`dd' ,.¢�rT•'.x �,�C' '+,.� .w, -r�'i"� �.'r4"+.? v+. i.'i�> �`"'f� -.,•,�• Yq` ,"t 't��•-� }i_.�e3 y�1.�- �.•.
i'x' xr, ;�I _ �" _ �� � �"`:se i•,r, ,rc:'N+ ��-'t, �1, .r ,.a;�. �)�y, 1r .,.,nom- `! .y,.,p. �k.,M...•t. .;:.r'•�.',it:
r-d '9��. 1 �.J �` `' ��- _4. '•-'�' S.:.3ti �'•.t-l` 'a`�'L.F- - -"••. -CS 4•:• `�»n:�-_ 'V[�;�'¢ T���:y4"i.ri Z�. � .'AFL `rq's , ® 'a4-
_ {,,�� `Y•:r�i•i,. _ - '��-:,'ftp �.: �,v _ � -- -'ra•'" "Nf�. '"�` .��"'f: _-.ar _ �,!r,} _ s.'. - ..4 r1.•-,�•. "�rrx _'r.5`.: _ 1 �
i .aiL `,..;�'�"qr_,[st°._ -:. +'•'���- ?-'�- ..,fa�"�, -'�3 ,,5 ,b - ':�','�k'.�. rU� --.r r: �:'�7t.•s. C:` - '�t,.t+i•,;"�'�i,,#;d.=r. -,:;.sfs,y..:,,, a� -.,,- rs'��c
y--;}N' � y'e..�' ;.3+.':i,9h'':' 1: ;;,,�.,..:�- � l - -�R+ �:.-�`+,�•.�w+ �.�-``- -o r*+�•,,_..a _ ,�h- '_+L'-,r�.. 4. "�---�,:. Y-,r�.� y _ r� „
.::',. k•„�-.,u� Lx;- �� ,��,, ".�iF- �+,*� -re. x:tir�—':��'�..�, '�•� »:`e�fl*y�" �'''x„ a� a'k'�-�-"�'�`` ^`-�,.;.�C - �'%-9 �R¢k�ct``'� '� S,
"� "` �� ���, ie� *�� a'i t�d� •Yw 'k-.r..-�F—r kr- ,«'i�si'"t , �'!•� � �S ��44�.._
�➢ }}`;l �1.� � _,d _. - < ..-_. ... ._ . __-`.I :4.t_. - .._�" - _. .. ..., 1- S_ .. . ,. +�� .I ,, _ f,x�-d� Y �ilt - ,.. _. .. _ .�_..-.ti ._ Y;,r'.��}'. �
r
Certificate of Completion
� g
Miami Shores Village
M
10050 NE 2 Ave, Miami Shores FL, 33138 ,�-•;• �
Tel: 305-795-2204 Fax: 305-756-8972
Building Inspection Department 4 �=�•ppy
This certificate issued pursuant to the requirements of the Florida Building Code 106.1.2 certifying that at the time of issuance this structure was in ,
um s ji compliance with the various ordinances of the jurisdiction regulating building construction or use. For the following:
WE,
+.; Permit Type RESIDENTIAL CONSTRUCTION Bldg. Permit No. RC-6-14-944fi �4 '
ter ,' Owner SHORES VILLAS CONDOMINIUM Contractor ESR FLORIDA CONSTRUCTION INCA
Subdivision/Project NONE Date Issued 07/12/2017
= _ v.
Occupancy
jai Construction Type V_g Load N/Ax
� - Occupancy "
'' Square Footage 320 Type R-3 `
Description of �` i
p SOAK PIT REPLACEMENT Applicable
2014 FLORIDA BUILDING
R .c• Work Code ..
y 3
Location Flood Zone X F.F.E N/A
8701 —9043 NE 4 Ave Road 4
x� Miami Shores FL 33138
113
,;� k ■■ ® nru� Building Officials Approval Ismael Naranjo, 06 a
Not Transferable
2
� * YI��pR'1DA POST IN A CONSPICUOUS PLACEi>f, '
� .
rr6,?f"-}. �__ .. d '. ,_:•1 :... ip'�k '^r -� t•'- �} b -i_l a - x:r--' r ..r=-r.. '- 4 .;1r- i ;'�T,
,Q�. •�,''� .h':4�v? � �'`;N ..�I�c �? saw¢:." -.�,•r.� -�"- -• =r Frei+ Yt �-_ .yy.r, �-As. `.. ,+t,io,:�s =�, �'a•. r -i�' ',. n i ,s a
• F Y"ii'- sn. '�s•�v,-dti�a r �a'• ,.�'�' 'r. l- .�"•r:'GP�: )) �,'���x'«i d �y�;.:.:'£- ;i ->``�'� y. �6., s'D-S.. a�.. �r
—'�. r.i i -5.. qq,, .�__ , � S. S. '1. T A 0 s 6 ��t �. 3 '� __ F '.• P', 7'r'�' S!3,".r' 4•. .ai� �.�A 1 0. %�
.g,, J"_`3�:.. '�1' •Yr r?;• ,� t - -ti~ r: _ , .a t ,:L.-. 3 _ - ;a +�k• r. yr -�"�+'i,a '+e '"'
���� d�l. ._, .. .//��,„l }-. ks'�•� s"a r '+.r,h rte:,, ;. •r?•!; ,�,+t rd•..r,. . ii-. 'i,.r "S _t4 $*.� '.�.s?'v = _ �p'�>. -..x,: e,f;' 'a' a 'E .w.--. r.::,,,, � .Si._
.e4 r �:-�, s'.�., •?^••'.�,,.,�,'L e.q rtF'^. :._ �.y f b. 4. sry cwt.;.- fill
3 3. ''k.% " `�' S,Sy a- :7_•r_ ?:w y-r.,l ins i r
.a _ kt _ .
-
S '�- .m:f p' Y M:'r'¢`✓<.' 6 . xW.4 ��' �� ;'v.' 6'A1 i^: ¢:'i�j ." 'k'V�. r'�V'•.�'•� .� ''F:.b:CL. .
..•,� `:'�i9:� `;'"`C..ar_aEw.. x a .:+�, .�•F.a+ �':,•,+ '^�iSi'� -e•«i•-.,�a+a .e...`.3 • �-ad•'n :�a n - '7j..Qti`•.1 `'�.:'' ?�.: +t,. y, s :�.is�1..� s:4� y-_•. ..x:r.
t .:' = - �s _ r rt" =21H -». -,a.,i!'.., -t. S-l.� 5 •,,.q,99. Y�"to - pp,,����,r" i. 's� of: r : i-. h.-,• +,t. �t .''0 /b:k s_� f"�+ {�.=;- to "+' i";-,#sly.
.♦ R ��
'�t• ft�' F P J � s ;I@♦ 9� r tak;'��-r�}, a , �. -H �.4"p ,.r..� Sx •L_. r r •¢y-Y'a1 h h;'',>� xx.•• 9 w T,;.; n'G' x
::2.°T-tib ;; '17.. _,`,..;f�7. n - �. nl k 1 LtdfY'" �d `�+y3�•.{�xlr{tY ei.•aa5!• 4_�'i6p� 'L Ya"��_{ 'r,�. 6h'k=' J �ti7 1:' 4�-, ut :�.•'rN "�"':4'r k�nc.� •,'
6k �..: ..t pb n ?4 . k._. �! . .?. t4;,a ud +�„ •"�. �'4R ,,4� < r • .dW.q?�F� �T''c �L�.'�..Haea ''�7s+,F ,,r
�! - , ..�. �-- P a I.-, .p� ..d x•.a •ff_ .,a•ro "'a.dv,.. .m .IL7 t, p'�:. � � i'"P„� 3 J .,� ,r�....�"b-:r�'I- .ir. r•7� oxa� - Y+ ax.,4
,.�'.•r•-s� w '��� '-4 x. .t i W:' L,'� v a a .->3• x Yi .o. .x' 1. .+qdh �,. "� �� g
..,�.b SIQta':4 x..-c. w'.ft VfE'b'..v,t'xbr--�qt *s* t ar � c7•�"��b'1,44'Nt'��x vx lit.�a6 i:���a:4rIM1'a. .,}a. 7�4 .,t.�j.4Flr, -.�fe� ,god .x�J�,�i�.�� rA`t1 it L',�y.tom.«�" - "ryi?if'. ,t"E t� '��i'L' ..FyY`.«.yi �-X54.,.- '.1��.'F?.
i �"^��1` •ri-. 1�,N �. I�.- �r d 1 a, .:�y�-r o � :7.a � n, '� �., ,� A n .�" ��1 F 1 'I.,�W.^wt I� Fri ,ya ,I,e Y ..�i!' ..- b .�14 •r a.
r'4,,�r,.:d YDS , +S.,s�+l*�. .�,, k� e ,t. ; t •x�{�,y-;yy!� :x; ,, �.,,j`n�xq"f :.• +�•G •+t�a '..5 ' v ai`t'•.t � i� r Yh-�d+;'y� �i v+��,�FT►' r�t{y""„ '.�'i �,pp �.�7ti;..
1 V ��, d' •••- �T G x+:.�i r .� ."�iT Rei'x �i# � �. r <i�l a ►� t,,3 1�Awe"#t a � �i4'��,..� 'tubi v `�" + 5�'::h,_�
;,� •#��P�'�X''-"'°_'r�"+ ��. -. .- °� ''.�:t�-;��✓'�,�"^�={ ,,. ��'"*`xas� •.. _ '§�j;,5i h,s� n'-5.}°__°X�'�• -J' �^ ��R�,_ .+ i
Miami Shores Village
Building Department
10050 NE 2 Ave, Miami Shores, FI 33138
Tel: (305)795-2204 9 Fax; (305)756-8972
10/21/2016
To: Current Owner
8701-9043 NE 4 Avenue (toad
Miami Shores, FL 33138-
Permit: RC-5-14-944
Address: 8701-9043 NE 4 Avenue Road Miami Shores FI-33138-
Dear Sir or Madam,
Our records indicate that the above referenced permit has expired without obtaining the
proper final inspection. In order to serve you better, we need to keep our files up to date.
As per section 105.4.1 of the Florida Building Code, "Every permit issued shall become invalid
(expired) unless the work authorized by such permit is commenced within six months after its
issuance, or if the work authorized by such permit is suspended or abandoned for a period of
six months after the work is commenced, or completed without obtaining the final inspection
of the work performed.."
Please be advised that open permits will hinder your ability to obtain new permits, refinance or
sell this property.
Please contact the Building Department, within 15 days of receipt of this letter in order to take
care of this matter.
Sincerely,
Ismael Naranjo (CBO)
Building Director
Miami Shores village ct
rVVBuilding Department artment (SAY 0 9 2014, �
90050 N.E.2nd Avenue,Miami Shores,Florida 33138 BY:
Tel:(305)795.2204 Fax:(305)756.8972
43INSPECTION'S PHONE NUMBER:(305)762A949
14 "YA44Luu-- FBC 20
BUILDING Permit No.
PERMIT APPLICATION Master Permit No.&
Permit Type: BUILDING ROOFING
,Y-7-0/ — q6 y3.
JOB ADDRESS:- �Qo / A f4_ 1/0 ON �p
City: Miami Shores County: Miami Dade lap; 6
Folio/Parce]#: 9 l � 2-0C-- - 4 -' 041 D
Is the Building Historically Designated:Yes NO Flood Zone:
OWNER:Name(Fee Simple Titleholder): C JS 6/1,,06-4 e#:_ d 5 7�� fi 4 o
Address• A. q'1'' A4 46
City:_ -,A&( WAJ State: Zip: l �"
Tenant/Lessee Name: Phone#:
Email:
CONTRAC Comp Name: hs'i � RA-I�AA 1- IJVLPhone#:_ � 6� �L/10
Address •b L 1
City: r- tate• L Zip:�• .aCj`�'
Qualifier Name: APhone#: WA 2�7 7 q 7 Z,�o
State Certification or Registration#: 4:::-6G GD<40 `-7- Certificate of Competency#: E`/tj e j
Contact Phone#: &S 02 2 �jj Email Addr s:
DESIGNER:Architect/Engineer: ����i'-� af.{L/�/ ! Phone#:�O�f• a��' 6�
Value of Work for this Permit:$ /n Square/Linear Footage of Work:
Type of Work: DAddition ]]Alteration ONew pair/Replace ODemolition
Description of Work• f r-
s
a
Color thm
Submittal Fee$ y LLZPermit Fee$ CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Bond$
Notary$ Training/Educadon Fee$ Technology Fee$
Double Fee$ Structural Review$
TOTAL FEE NOW DUE$_�?Sa •50
Bonding Company's Name(if applicable)
Bonding Company's Address
City State zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved d a reinspection fee will be ced.
rg
Signature Signature
Owner or Agent //ontractor
The foregoing i was o edged form a thi�s�— The foregoing instrumen as acknowledged before
me thisL.?—/
day of_ r ' ,2 by �L—. day o 20 ,by�s�'P'C�R�1QT9,> ��iV 1P$
who is personally known to me or who has produced—�ph�iss peerso al] o me ho s produced ''J 7)
As identification and who did take an oath. Ob / as ide ho did take an oath.
NOTARY PUBLIC: NOTARY P L
Si Sign:
Print: J Print: •° '�1 ° Y'�
a�P' A� CASANDgq NARRI m
M Commission Expires SON My Commission o
Y P �' h Notary Public,State of FloridaZZ
:• �rEOFF��P\oi�h o�
Commission#EE198163 .tJ% •gy24,Z�•''��' ��
MY�mm,expir®s May 14,2016 ��iss c0i19/�°/e'e'n�`° rC��'
dkkkkkkkkk+xkkk+k�k+k+xhkkkR�+kkkka:+sk k*k&&*k. kk**kkak*+s�NB+k+k+k*+k#k6�k+k*+k&*+(qtr �k�#�Rt�k �dt&kd+R*&*aea
111iIII Illy
APPROVED BY 2/3 i Plans Examiner Zoning
I ° Structural Review Clerk
(Revised 3/122012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
SHORES VILLAS CONDOMINIUM ASSOC., INC.
8901 NE 4th Avenue Road
Miami Shores, FI. 33138 CETVD
EE
MAY 0 9 2014
May 8, 2014
BY-
May
WHOM IT MAY CONCERN
I, John Dillon, Vice President of the Shores Villas Condominium Association, Inc, do hereby
acknowledge that ESR Florida Construction, Inc. along with sub-contractors, will be completing
work approved by DERM located at 8901 NE 4th Avenue Rd., Miami Shores, FI. 33138
This includes drain field and soak pit.
Joh 'lion, Vice President
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-284370 Permit Number: RC-5-14-944
Scheduled Inspection Date: June 16, 2017 Permit Type: Residential Construction
Inspector: Porta Jr,Jose
Inspection Type: Final
Owner: OLARTE, GERARDO Work Classification: Alteration
Job Address:8701-9043 NE 4 Avenue Road
Miami Shores, FL 33138- Phone Number
Parcel Number 1132060460660
Project: <NONE>
Contractor: ESR FLORIDA CONSTRUCTION INC Phone: (305)812-2716
Building Department Comments
REMOVE AND REPLACE EXISTING SOAK PIT Infractio Passed comments
ACCORDING TO PLANS APPROVED BY DERM INSPECTOR COMMENTS False
Inspector Comments
Passed ��1� CREATED AS REINSPECTION FOR INSP-284210. CREATED AS
REINSPECTION FOR INSP-282116. CREATED AS REINSPECTION FOR
INSP-282008. CREATED AS REINSPECTION FOR INSP-281968.
❑ 05/0
Failed
CANCELLED BY ED
05/09/2017
Correction ❑ CANCELLED BY ED
Needed 06/14/2017
CANCELLED BY ED
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
June 15,2017 For Inspections please call: (305)762-4949 Page 15 of 27
JEFF ATWATER
CHIEF FINANCIAL OFFICER STATE OF FLORIDA
DEPARTMENT OF FINANCIAL SERVICES
DIVISION OF WORKERS'COMPENSATION
**CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS'COMPENSATION LAW
CONSTRUCTION INDUSTRY EXEMPTION
This certifies that the individual listed below has elected to be exempt from Florida Workers'Compensation law.
EFFECTIVE DATE: 2/29/2016 EXPIRATION DATE: 2/28/2018
PERSON: RICZO EDWARD S
FEIN: 203142035
BUSINESS NAME AND ADDRESS:
ESR FLORIDA CONSTRUCTION INC
PO BOX 150472
CAPE CORAL FL 33915
SCOPES OF BUSINESS OR TRADE:
LICENSED GENERAL
CONTRACTOR
Pursuant to Chapter 440.05(14),F.S.,an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section
may not recover benefits or compensation under this chapter.Pursuant to Chapter 440.05(12),F.S.,Certificates of election to be exempt...apply only
within the scope of the business or trade listed on the notice of election to be exempt.Pursuant to Chapter 440.05(13),F.S.,Notices of election to be
exempt and certificates of election to be exempt shall be subject to revocation If,at any time after the filing of the notice or the issuance of the certificate,
the person named on the notice or certificate no longer meets the requirements of this section for Issuance of a certificate.The department shall revoke a
DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 08-13 QUESTIONS?(850)413-1609
r SHORES VILLAS CONDOMINIUM ASSOCIATION
8901 NE FOURTH AVENUE ROAD — MIAMI SHORES, FLORIDA 33138
Ismael Naranjo December 22, 2015
MSV Building Director
10050 NE 2"6 Avenue
Miami Shores, FL 33138
DEL 212015
Dear Mr. Naranjo:
I am Bill Serda, a member of the Shores Villas Condominium Association Board of
Directors, and the informal project manager of the condominium's "on going" and long
delayed construction project, involving the replacement of the on site sewage plant
"Soakage Pit".
Upon our request, in late November, 2015, you graciously allowed an extension of our
working Permit, to January 4, 2016 (approximately 30 days).
Unfortunately, we encountered unexpected problems scheduling our work and
achieving adequate progress - somewhat due to the interruptions of the Xmas and
New Year Holidays — but more significantly, due to the ongoing painfully slow "Decision
Making Progress" of our Condominium Board of Directors.
We (the Condo Board) are all fully employed in demanding full time jobs, and serve as
the Managing Board in what is left for"spare time". Further difficulty is caused by many
Board members being very inexperienced.
Consequently, we were unable to quickly reach decisions on issues related to this
project, and lost approximately two weeks, or more, of the valuable 30 day extension,
which you allowed us earlier.
The Contractor(ESR) has begun work, but, due to the late start, will not be ready for a
key and critical code inspection of the Soakage Pit Wall Forms, for another two or three
weeks—for all of the above reasons.
My embarrassed and respectful request is for an additional extension of thirty days
(February 05, 2016), so that we can, without interruption, continue to press forward and
finish this project as soon as possible.
PAGE ONE OF TWO
...... . .. ......
.... . .. .....
...... . . .....
.. .. •• •• ..0 0
. . . . ......
00 0
d
SERDA LETTER—SECOND PERMIT EXTENSION — 12/22/2015
PAGE TWO OF TWO
We have two permits which are currently valid, but, expiring, in early January, 2015, at
the conclusion of your earlier extension
The two permits are:
RC-5-14-944 for the Soakage Pit .
RC-5-14-945 for the Continuous Drain Field.
Thus, we are respectively requesting an additional thirty (30) day extension (to February
05, 2016), for our next inspection, so that our permit will stay active, to complete the
project.
If there is a fee required, we can arrange for immediate payment, upon your decision.
Thanks for your time and consideration of this most difficult and embarrassing situation
and request.
Bill Serda Telephone 305-785-7760
Shores Villas Condominium
Board of Directors
•9.9.0
000 0000:9
.. . .. . 9
• •
0000.. ,. 0000..
009.4• 9
•0900•
0000 ..
• •
0000 .. 90000
0000.. . . 0000.
• 4 • • 9
•• •• •• 09 ••9.00
9
•99.0• • •
• • • • 004.00
•••99•
• • 4 • •
NOV 2 0
SHORES VILLAS CONDOMINIUM ASSOCIATION
8901 NE FOURTH AVENUE ROAD— MIAMI SHORES, FLORIDA 33138
Ismael Naranjo November 20, 2015
MSV Building Director
10050 NE 2"d Avenue
Miami Shores, FL 33138
Dear Mr. Naranjo:
I am Bill Serda, a member of the Shores Villas Condominium Association Board of
Directors, and the informal project manager of the condominium's"on going" and long
delayed construction project, involving the replacement of the on site sewage plant
soakage pit.
We encountered a major delay and interruption of the construction project, over the last
three or four months, due, primarily to:
1. The complexity of the project, unexpected costs, our Board's inexperience
with construction issues, disputes over costs and our Board's difficulty with
reaching needed quick decisions.
2. The above difficulties were exacerbated, even further, by the simultaneous
severe illness within the family of a critical Board Member.
We are now poised and ready to move forward, beginning in December, 2015.
We have two permits which are currently valid, but, expiring, also, in early December,
2015.
The two permits are:
RC-5-14-944 for the Soakage Pit .
ft 5-14-945 for the Continuous Drain Field.
We are respectively requesting a thirty (30) day extension for our next inspection, so
that our permit will stay active, to complete the project.
PAGE ONE OF TWO
r
r
SERDA LETTER— PERMIT EXTENSION — 11/20/2015
PAGE TWO OF TWO
I have enclosed my personal check (#5084), payable to MSV, in the amount of$75.00,
as the prescribed fee for this request and re-evaluation.
As a further complication, the timing of this request, the Friday before Thanksgiving
Week, makes it significantly advantageous if we could have your early decision - and
significantly disadvantageous, if such decision is delayed.
Thanks for your time and consideration of this most difficult and embarrassing situation
and request.
2 Le-ja faLv�
Bill Serda Telephone 305-785-7760
t �
RATIONAL ANALYSIS AND ENGINEERING DESIGN CALCULATIONS
FLORIDA BUILDING CODE
Y
NEW SOAK PIT FOR SHORE VILLA CONDO
UNIT AT 9017 NORTHEAST 4TH AVENUE ROAD
MIAMI SHORES, FLORIDA 33138
DATE:08-06-2013
TABLES OF CONTENTS:
1. RETAINING WALL AND FOOTING DESIGN PAGES: 1-5
2. 8"X8"CONCRETE BEAM DESIGN PAGES 6-7
3. 8"CONCRETE SLAB DWSIGN PAGES 8-10
4. 8"CONCRETE WALL DESIGN PAGES 11-12
CHARLES C.MITCHELL-CONSULTING ENGINEER ASSUMES RESPONSIBILITY FOR BOTH MANUAL
AND COMPUTER GENERATED CALCULATIONS.
CHARLES C.MITCHELL-CONSULTING ENGINEER.
P.E.#11127
924 NORTH FEDERAL HIGHWAY
HOLLYWOOD,FLORIDA 33023
TOTAL PAGES :12
.�`% BO'S
��`� P� G�-N s -:CSS► '%
* No. 1.1127
STATE OF C
c�'-• <O R gyp..��
i'i���SS'O N Al
� a
CHARLES C. MITCHELL , P.E. SOAK PIT FOR SHORE VILLA CONDO UNIT
P.E. 0011127
Cing Engineer AT 9017 NE 4TH AVE. RD
305.945.0205.0202 / 305.828.0140
1515 n.w. 167 th Street Suite 110-T MIAMI SHORES, FL 33138
MIAMI, FLORIDA 33169
�. .�r._..2.33. .f;.. .. . . .:. . . . . . .
�7A
.............. ..............
... i� ... .. .. .. ' ..
:...
...� .� x.3.3-.. , �.2 . ... ._ ..
.. .. .. ..
.: .....: .. . .. ..
...;.e . . . .. � ....... .
= T
... .. ..
..:. ..:....:... :.. .
.........�.. .. ........
................... .....
�✓. . �` .....=... . ... :3�Z�c f:�:.9 . t x:33 3 .33
�.....:... J ..
F/
.... ..... ... rj 14
... ................. ..........................
1�b.tt a
...... ... ... .
,,
... �' WrATE
.. .. ... ....
OR
..................
L ej •: J:�
Rev:510300 Restrained Retaining Wall Design Page 1
Description
Criteria Soil Data Footing Strengths&Dimensions
Retained Height = 5.00 ft Allow Soil Bearing = 2,000.0 psf Pc = 3,000 psf Fy = 60,000 psi
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method Min.As% = 0.0014
Total Wall Height = 5.00 It Heel Active Pressure = 0.0 Toe Width = 0.83 It
Toe Active Pressure = 0.0 Heel Width = 1.50
=
Top Support Height = 5.00 ft Passive Pressure 0.0Water height over heel = 0.0 ft Total Footing Width
SlopeBehind Wal = 0.00: 1 = Footing Thickness = 12.00 in
Footing��Soil Frictior 0.300
Height of Soil over Toe = 60.00 in Soil height to ignore Key Width = 0.00 in
Soil Density = 110.00 pcf for passive pressure = 0.00 in Key Depth = 0.00 in
Key Distance from Toe = 0.00 It
Wind on Stem = 110.0 psf Cover @ Top = 3.00 in @ Btm.= 3.00 in
Surcharge Loads Uniform Lateral Load Applied to Stem Adjacent Footing Load
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#!ft Adjacent Footing Load = 0.0 lbs
-NOT Used To Resist Sliding&Overturn ,.•Height to Top = 6.00 ft Footing Width = 0.00 ft
Surcharge Over Toe = 0.0 psf ...Height to Bolton• = 0.00 ft Eccentricity = 3.00 in
NOT Used for Sliding&Overturning Wall to Fig CL Dist = 0.92 It
Axial Load Applied to Stem Footing Type Line Load
Axial Dead Load = 366.0 lbs Base Above/Below Soil = 0.0 ft
Axial Live Load = 1,833.0 lbs at Back of Wall
Axial Load Eccentricity = 0.0 in
Design Summary item Construction
Total Bearing Load = 3,935 lbs Thickness = 8.00 in Fy = 60,000 psi
...resultant ecc. = 0.00 in Wall Weight = 96.7 pcf 1'c = 3.000 psi
Soil Pressure @ Toe = 1,689 psf OK Stem is FIXED to top of footing
Soil Pressure @ Heel = 1,689 psf OK
Allowable = 2,000 psf Mmax Between
Soil Pressure Less Than Allowable @ Top Support Top&Base @ Base of Wall
ACI Factored @ Toe = 2,600 psf Stem OK Stem OK Stem OK
ACI Factored @ Heel = 2,600 psf Design height = 5.00 ft 0.00 ft 0.00 ft
Footing Shear @ Toe = 13.2 psi OK Rebar Size = # 5 # 5 # 5
Footing Shear @ Heel = 8.0 psi OK Rebar Spacing = 12.00 in 12.00 in 12.00 in
Allowable = 93.1 psi Rebar Placed at = Center Center Center
Reaction at Top = lbs Rebar Depth 'd' = 4.00 in 4.00 in 4.00 in
Reaction at Bottom = 0.0 lbs Design Data
fb/FB+fa/Fa = 0.000 0.000 O.Q00
Sliding Calcs Slab Resists All Sliding! Mu...Actual = 0.0 ft-# 0.0 ft-# 0.0 ft-#
Lateral Sliding Force = 8.0 lbs Mn'Phi.....Allowable = 5.154.8 ft-# 5,154.8 ft-# 5,154.8 ft-#
Shear Force @ this height = 0.0 lbs 0.0 lbs
Shear.....Actual = 0.00 psi 0.00 psi
Shear....Allowable 93.11 psi 93.11 psi
Footing Design Results Rebar Lap Required = 21.36 in 21.36 in
TOOeeI Rebar embedment into footing = 6.00 in
Factored Pressure = 27M 2,600 psf Other Acceptable Sizes&Spacings:
Mu':Upward = 899 0 ft-# Toe:#5 @ 18.00 in -or- Not req'd,Mu<S"Fr
Mu':Downward = 339 339 ft-# Heel:#5 @ 18.00 in -or- Not req'd,Mu<S"Fr
Mu: Design = 560 339 ft-# Key: No key defined -or- No key defined
Actual 1-Way Shear = 13.21 7.99 psi
Allow 1-Way Shear = 93.11 93.11 psi
Y A
Rev.810300 Restrained Retaining Wall Design Page 2
Description
Summa of Forces on Footin : Slab RESISTS slidin ,stem is FIXED at footin
Forces acting on footing for soil pressure >>>Sliding Forces are restrained by the adjacent slab
Load&Moment Summary For Footing:For Soil Pressure Caics
Moment @ Top of Footing Applied from Stem = ft-#
Surcharge Over Heel = lbs ft ft-#
Axial Dead Load on Stem = 2,199.Olbs 1.17 ft 2,561.8 ft-#
Soil Over Toe = 457.4 lbs 0.42 ft 190.2 ft-#
Surcharge Over Toe = lbs ft ft-f
Stem Weight = 483.3 lbs 1.17 ft 563.1 ft-#
Soil Over Heel = 457.4 lbs 1.91 ft 875.6 ft-#
Footing Weight = 337.9 lbs 1.17 ft 393.6 ft-#
Total Vertical Force = 3,935.0 lbs Base Moment = 4,584.3 ft-#
Soil Pressure Resulting Moment= -O.Qt-#
r �{
8.0
Lateral Restraint
0.#
8.00005"ConcrelN4161 115 @ 12." 5'-0" 5'-0" 5'-0"
8.00005"Concrete w/ 5 @ 12."
Sliding Restraint
3..
#5@18.in
@Toe
@ Heel
2'-4„
DL=366.,LL= 1833.49999990.0005#, Ecc=0.0005in
Lateral Restraint
0.#
Sliding Restraint
Pp=0.#
0.#
1688.8psf
1688.8psf
r
z ,
RATIONAL ANALYSIS AND ENGINEERING DESIGN CALCULATIONS
FR. i'-d CODE
E 2 .1
fl
NEW SOAK PIT FOR SHORE VILLA CONDO
UNIT AT 9017 NORTHEAST 4TH AVENUE ROAD
MIAMI SHORES, FLORIDA 33138
DATE:08-06-2013
TABLES OF CONTENTS:
1. RETAINING WALL AND FOOTING DESIGN PAGES: 1-5
2. 8"X8"CONCRETE BEAM DESIGN PAGES 6-7
3. 8" CONCRETE SLAB DESIGN PAGES 8-10
4. 8" CONCRETE WALL DESIGN PAGES 11-12
CHARLES C. MITCHELL-CONSULTING ENGINEER ASSUMES RESPONSIBILITY FOR BOTH MANUAL
AND COMPUTER GENERATED CALCULATIONS.
CHARLES C. MITCHELL-CONSULTING ENGINEER.
P.E.# 11127
924 NORTH FEDERAL HIGHWAY
HOLLYWOOD,FLORIDA 33023
TOTAL PAGES : 12
`,`,"��es f!lAt/
* f No,. 1.1127
STATE OF
r
t .�• t C
-. o,, ..C0R Vit).'
s/f1PlAV
,�ftttf!ltlttt`t,
r
................M...,.,.......,...,.,._.._.._......._.._.- .____._............ ....... .._-.-.-_.-----------------------
....................................
......_.._....._------
.._....... _..
p-........._..............,
Restrained Retaining Wall DesignMMOOMM
age '
Description
:..........................................................-...............................__................ ;........__. ;F . .......................................
_....._..... _........m.._._
Criteria Soil Data i Footing Strengths&Dimensions
l.. ;
Retained Height 5.00 ft Allow Soil Searing = 2,000.0 psf fr, = 3,000 psi Fy = 60,000 psi
Wall height above soil = O;OOft Equivalent Fluid Pressure Method Min.As% = 0.0014
Total Wall Height - 6.00 ft Heel Active Pressure - 0.0 Toe Width - 0.83�t
Toe Active Pressure = 0.0 Heel Width _ 1.50
Passive Pressure = 0.0
Top Support Height = 5.00 It Water height over heel = 0.0 ft Total Footing Widtt m --2:33..
Footing Thickness - 12.00 in
Slope Behind Wal - 0.00: 1 FootingliSoil Friction - 0.300
Height of SoiE over Tae = 60.00 in Key Width - 0.00 in
Soil height to ignore
Soil Density - 110.00 pcf for passive pressure - 0.00 in Key Deth 0.00 in
Key Distance from Toe = 0.00 It
Wind on Stem - 110.0 psf Cover @ Top = 3.00 in @ Stm.= 3.00 in
Surcharge Leads Uniform lateral toad Applied to Stem I Adjacent Footing Load
w.
Surcharge Over Neel w 0.0 psf
9 taterai Load - OA#tft Adjacent Footing Load - 0.0 lbs
»>NOT Used To Resist Sliding&Overturn ,..Height to Top - 6.00 It Footing Width - 0.00 it
Surcharge Over Toe w 0.0 psf ...Height to Bottorr = 0.00 ft Eccentricity - 3.00 in
NOT Used for Sliding&Overturning
ng.................. Wail to Ftg CL Dist = 0.02 ft
i Axial Lead Applied to Stem Footing Type Line Load
"
Axial Dead Load .- 366.0 lbs Base Abovel8elow Soiiat Back of Wall - 0.0 ft
Axial Live Load = 1,833.0 lbs
Axial Load Eccentricity = OA in
__._....-...... .....................................
si n Stln'tmt % z� Concrete SteiYl Gc�nstruction
: � �•�� � �.• ._ �,.�^ ..�s� .... . ..
Total Bearing Load - 3,935 lbs Thickness = 4.00 in Fy = 60,00opsi
...resultant ecc. - 0.00 in Wall Weight = 95.7 pcf fc = 3,000 psi
Soil Pressure @a Toe - 1,689 psf OK Stem is FIXED to top of footing
Soil Pressure L Heel 1.689 psf OK
Allowable 2,000 psf Mmax Between
Soil Pressure Less Than Allowable @ Top Support Top&Base @ Base of Wail
ACI Factored @ Toe w 2,600 psf _.........................._........_..................__....___.._. _.....___....
ACI Factored @ Heel 2:600 psf - Stem OK Stem OK Stem OK
Design height - 5.00 it 0.00 It 0.00 ft
Footing Shear o@ Toe - 13.2 psi OK Rebar Size - # 5 # 5 # 5
Footing Shear§Hee; = 8.0 psi OK Rebar Spacing = 12.00 in 1.2.00 in 12.00 in
Allowable - 93.1 psi Rebar Placed at - Center Center Center
Reaction at Top = lbs Rebar Depth V4,00 in 4.00 in 4.00 in
Reaction at Bottom = 0.0 lbs Design Data -
fblFB+fa/Fa - 0.000 0.000 0.000
Sliding Cale. Slab Resists All Slidingg? Mu....Actual - 0.0 ft-## 0.0 ft-f# 0.0 ft-#
Lateral Sliding Force 0.0 lbs Mn'Phi.....Allowable - 5,154.8 ft-# 5,154.4 ft-# 5,154.8 ft-#
Shear Force @ this height = 0.0 lbs 0.0 lbs
Shear.....Actual - 0.00 psi 0.00 psi
Shear-..Allowable = 93.11 psi 93.11 psi
l oci in Desi n Results Rebar Lap Required = 21.36 in 21.36 in
�0 e®l Rebar embedment into footing = 6.00 in
Factored Pressure % 2,600 psf Other Acceptable Sizes S Spacings:
Mu':Upward - 899 0 ft-# Toe:#5 @ 18.00 in -or- Not req`d,Mu<S°Fr
Mu', Downward - 339 339 ft-# Heel:#5 @ 14.00 in -or- Not req'd.Mu<S k Fr
Mu: Design = 560 339 ft-# Key: No key defined -or- No key defined
Actual I-Way Shear = 13.21 7.99 psi
Allow 1-Way Shear = 93.11 93.11 psi
:_......_..:..:.:_............_.............__.._.._....._.._............._..._. _..._..__..........................._._............................. _. __. _.._._.._..............................._............._._....._._...w.._.
Restrained Retaining Wall Design Page 2
Description
�................... .....
......_...
.............__...,...................
..........
....5`.._._._.._.... __.................................................................._......_......,.......... .>>
Starrttna oforc�a on Footing: �laia RE aiTlid'on atc� its( ®at foati
zk /�aocs.. au .�:u�„asuar.�iwv
Farces acting on footing far soli pres$ure »>Sliding Fomes ere restrained by the�►stjacent stab
Load a Moment Summery For Footing:For Soi!Pressure Calcs
......................_.------------------------......................._ � .�......_......._...................._................
Moment @ Top of Footing Applied from Stern - ft-#
Surcharge Over Heel w lbs ft ft-#
Axial Dead Load on Stem = 2,199.0lbs 1.17 ft 2.561.8 ft-#
Soil Over Toe 457.4 lbs 0.42 ft 190.2 ft-#
Surcharge Over Toe - lbs ft ft-#
Stem Weight - 483.3 lbs 1.17 ft 563.1 ft-#
Soil Over Heel - 457.4 lbs 1.91 ft 875.6 ft-#
Footing Weight - 337.9 lbs 1.17 ft 393.6 ft-#
Total Vertical Force 3,935.0Ibs Base Moment = 4,584.3 fta#
Soil Pressure Resulting Moment= 4Eft-#
3.f 0005" 5.x.12"
Lateral Restraint
Q. XF
# is ;
>w
Ik
..R.. f3
1,00005"Concreg-91#5 i�� 12." 5,-0, ' ��;q � 5,yOu
S.00005"Concrete wl#5 12." 3"
..._................--....._.........._ ..................._..._..._........_......._I._... ........................
........_.....
.
Raiding Restraint
3 3„
Occ—P 1€3.in
i
r@ oe
I
5�1
1f1" 1,-6" i
E.in _..............M;
@ Heel
Z-4-
DL=366.>LL=1833.49999990.0005#, Ecc=0.0005iri.
Lateral Restraint t
0.#
i
x�
X
,t
F4•
...............................................................................................................».....
Sliding Restraint l
pp=0.#
0.#
1688.8psf
1688.6psf
22"CAST IRON FRAME&COVER Wi GASKET
STANDARD ACCESS MANHOLES
V ASPHALTIC CONC.W/6"THICK CRUSHED LIMEROCK
COMPACTED TO 95%DENSITY
r THICK TRAFFIC LID W45 REBARS MAT
e ae.
SOUTH,,
_.._ I .!.... loov '`.. 8°X r CROSS BEAM @ 72"O.C. SEE BE APA PLAN
?_...... — _ _....___..................... W1 2-#5 REBARS EMBEDDED 6 INTO 8 CONC WALL
ON EACH SIDE
444 -V :
op
ISI
;.......:? ? — .... 8"CONIC.WALL045 REBARS m 42°O.C.VERTICAL
... ......_... .._ __.._....... .._..................
HORIZONTAL
..?a.`•.,---??j:�'.mI i i�:::::I i ._...I 3 �— .. 7 IT
.. F r::::.�E jw.,
GRADE
--
:
I;_
..?F
.:f ?i
12" ':6"CONC.FOUNDATION W!2-AS REBARS CONTINUOUS
:.
I I€ I I I (TYP•)
1 BALLAST ROCK.BASE
: .... ? -.... , ._.. ........ ?3.......1.:: •• —;r_...._... i .t
___
}•/t .._. } .. `I
fl
�•�(''jE!( .. J' ___ � •: _..:: _:a-t ??..__.:1 ....._�: Ii � it � �.::• :.. •
liA-..e.E �:7 .FI .;•- : .- . I: ,. .. . ._..{: ...... ..I• —_ ?:• ?t.k.T •E ::..
_.. �?? ...«...F{p: .. !:f:. :. , _ .....- ?+:. I: t �, •i ;.;;is .._
-........:. F#'•T. ......:7iTl.:.......:.737......? ...... .:.:.._..... a-_ :+73.,.•...'(^'p........ .:. _..... :.: ........ .:....... .. � ..._ S7I37......�t7f;...:.. .. ...... ,
ROV'"I'll Concrete Rectangular & Tee Beam Design Page 1 '
Description CONCRETE BEAM
Reinforcing
Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam...
Count Size 'd'from Top Count Size 'd'from Top Count Size 'd'from Top
#1 2 5 9.88 in #1 in #1 in
Uniform Loads
Dead Load Live Load Short Term Start End
#1 0.342 k k k 0.000 ft 4.670 ft
Concentrated Loads
Dead Load Live Load Short Term Location
#1 k 4.000 k k 0.000 ft
SummaryBeam Design OK
Span=4.67ft,Width=8.00in Depth=8.00ln
Maximum Moment:Mu 1.55 k-ft Maximum Deflection -0.0041 in
Allowable Moment:Mn*phi 25.01 k-ft
Maximum Shear:Vu 7.66 k Max Reaction @ Left 4.95 k
Allowable Shear:Vn*phi 33.66 k Max Reaction @ Right 0.95 k
Shear Stirrups...
Stirrup Area @ Section 0.220 in2
Region 0.000 0.778 1.557 2.335 3.113 3.892 4.670 It
Max.Spacing 4.000 Not Req'd Not Req'd Not Req'd Not Req'd Not Req'd Not Req'd in
Max Vu 7.661 0.893 0.446 0.436 0.436 0.882 0.850 k
Bending &Shear Force Summary
Bending... y Mn*Phi Mu,Eq.9-1 Mu,Eq.9-2 Mu,Eq.9-3
@ Center 25.01 k-ft 1.55 k-ft 1.16 k-ft 1.00 k-ft
@ Left End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
@ Right End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
Shear... Vn*Phi Vu,Eq.9-1 Vu,Eq.9-2 Vu,Eq.9-3
@ Left End 33.66 k 7.66 k 5.75 k 0.55 k
@ Right End 5.96 k 0.85-k 0.64 k 0.55 k
Deflection
Deflections... .* Upward Downward
DL+[Bm Wt] 0.0000 in at 4.6700 ft -0.0041 in at 2.3350ft
DL+LL+[Bm Wt] 0.0000 in at 4.6700 it -0.0041 in at 2.3350ft
DL+LL+ST+[Bm Wt] 0.0000 in at 4.6700 it -0.0041 in at 2.3350ft
Reactions... @ Left 0 Right
DL+[Bm Wt]] 0.949 k 0.949 k
DL+LL+[Bm Wt] 4.949 k 0.949 k
DL+LL+ST+[Bm Wt] 4.949 k 0.949 k
Section Analysis
Evaluate Moment Capacity... Center Left End Riaht End
X:Neutral Axis 2.145 in 0.000 in 0.000 in
a=beta*Xneutral 1.823 in 0.000 in 0.000 in
Compression in Concrete 37.194 k 0.000 k 0.000 k
Sum[Steel comp.forces] 0.000 k 0.000 k 0.000 k
Tension in Reinforcing -37.200 k 0.000 k 0.000 k
Find Max As for Ductile Failure...
X-Balanced 5.844 in 0.000 in 0.0000 in
Xmax=Xbal*0.75 4.383 in 0.000 in 0.000 in
a-max=beta*Xbal 4.968 in 0.000 in 0.000 in
Compression in Concrete 76.006 k 0.000 k 0.000 k
Sum[Steel Comp Forces] 0.000 k 0.000 k 0.000 k
Total Compressive Force 76.006 k 0.000 k 0.000 k
AS Max=Tot Force/Fy 1.267 in2 0.000 in2 0.000 in2
Actual Tension As 0.620 OK 0.000 OK 0.000 OK
t
' O.�a4RMtd of}{{�8<i lrf 11 i}qif�di tiildai#iti9i#idt 0.3421Utt
a
it
Mu Max=1.55k-i1
Dmax=0.0041 in
-__Rmax_=4.948k ___ Rmax=0.949k
Rev:51990Maz=7.861k Concrete Rectangular & Tee Beam Design Page 2
Description CONCRETE BEAM
Additional Deflection Calcs
Neutral Axis 3.120 in Mcr 2.92 k-ft
Igross 341.33 in4 Ms:Max DL+LL 1.11 k-ft
]cracked 343.78 in4 R1 =(Ms:DL+LL)/Mcr 2.636
Elastic Modulus 3,122.0 ksi Ms:Max DL+LL+ST 1.11 k-ft
Fr=7.5'f'cA.5 410.792 psi R2=(Ms:DL+LL+ST)/Mcr 2.636
Z:Cracking 9.655 ksi keff...Ms(DL+LL) 341.333 in4
keff...Ms(DL+LL+ST) 341.333 in4
Elf.Flange Width 8.00 in
ACI Factors (per ACI,applied internally to entered loads)
ACI 9-1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4"Factor 1.400
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9"Factor 0.900
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300
....seismic=ST': 1.100
Sketch& Diagram
0.47 0.93 140 .1.87 34 0.80 3.27 p.74 4.20 14.87N47 �.40 +I.87 -p.34 Q.80 9.27 S.74---4.20 4.67
�. E E
00 j
boll'.
10.53 - A.40
{0.79 - - 10.59
;:1.05 :0.79 E
Shear Load(k) Location Along Member(ft) Shear Load(k) Location Along Member(it).
3.55 0.47 0.93 740 : - -80 9.27 X3.74 4 20 -4.67 3.16 0.47 0 93 9 40 ' 80 3.27 0.74 4.20 ii.87
1 i i ` I _
3.40 i 1.05 '3
3.24 9,93
j.09 081
0.93 1 i y b 70 1
.: 0.78....j.. " ° '^ •i. 058 1 -i_
0
! j
i
BeRcft Moment(k-ft) Location Along Member(ft) BaPd%Moment(k-ft) Location Along Member(fry
Beam Sketch Stresses for ACI 9-1 Combination Stresses for ACI 9-2 Combination
p 47 ?.93 Y 40 1 87 234 ¢60 y3 27 B 74 ri 20 X1.87 7 0.93 ).40 1.87 R.34 �.80. b.27 3 74 k 20 A.6701147 0 93 E1.40 1 87 x.34 �2 80 9.27 3 74 4.20 >4.67
).4000 ! -
.00 ? %0.58_ jo56
;.0.75
((kg g0 mbar(ft) Shear Load/k) Io Alonp,Mambe (ft)
,0.34 Sh�arOLoad 47) b.93. 7 40 n 27 9.74 P4 20_--4.67 y 11 0.47 0 93 '�.40.- � 3.27 53.7 4 4.20 4.67
:0.51.. i :�._ ' etl n 089
O.68 0.78 _F { : -._ 078 ` I.
Shear Loatl(k) Location Along Member(ft) 0 55 i i , i i 0 @5 I i
I.00 0.47 P.93 .4.40 80 p.27 9.74 A.20 4.67 0.44 i qq i
EE i
0.80
0.70 i4 i'Z i ,i E E Be Be !'
0. #.87 F'4.67
0.60 3 : woo.. : 3 i0.00
E pP -.0.00
0 •I ' I E E r W,00 .0 00 3..
0.30 i : X0.00- -0 W 'r
u ,000 I' '
p.2 i t io.00 i m 00
b I E
I o00 •' i -_ € -;000
kL
Be CRR9 Moment(k-ft) Location Along Member(ft) Local"y"Deflection(in) Location Along Member(tt) Local"y"Deflection (in) Location Along Member(it)
Stresses for ACI 9-3 Combination Stresses for Service Dead+Live Loads Stresses for Dead+Live+Short Term Loads
CHARLES C. MITCHELL P.E. SOAK PIT FOR STORE VILLA CONDO UNIT
P.£, 0011927
C5.020ing 305. 28 AT 9017 NE 4TH AVE. Rte
308.995.0202 / 308,028.0'190
9515 n.wr. 167 th street Suite 110—T MIAMI SHORES, FL 33133
MIAMI, FLORIDA 33169
• I�,
. .
--------------------------------
.:....:... ,. {5 .. ... j..
.131 � ' ' ">! 6"�' 'H£ ! ♦1! y£A '
.. >.,..
.. .. .. .... i`. .. .. .. .. .. .. .. .. ..
o� . .:p.
.. ...
-.
... ; ....
... ....`:%' ...; ,..... ....:....... .... r 7 yid
... ... «.
77
STATE OF,
NN
$ :{l pll il9t
Rev'510300 Concrete Rectangular & Tee Beam Design Page 1-'.
Description 8" CONCRETE SLAB
Reinforcing
Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam...
Count Size 'd'from Top Count Size 'd'from Top Count Size 'd'from Top o
#1 1 5 9.88 in #1 in #1 in
#3 in #3 in #3 2 7 2.31 in
Uniform Loads
Dead Load Live Load Short Term Start End
#1 0.362 k k k 0.000 ft 6.000 ft
Concentrated Loads
Dead Load Live Load Short Term Location
#1 k 4.000 k k 3.000 ft
Summary Beam Design OK
Span=6.00ft,Width= 12.00in Depth=8.00in
Maximum Moment:Mu 13.11 k-ft Maximum Deflection -0.0552 in
Allowable Moment:Mn*phi 13.35 k-ft
Maximum Shear:Vu 9.00 k Max Reaction @ Left 3.39 k
Allowable Shear:Vn*phi 36.64 k Max Reaction @ Right 3.39 k
Shear Stirrups...
Stirrup Area @ Section 0.220 in2
Region 0.000 1.000 2.000 3.000 4.000 5.000 6.000 ft
Max.Spacing 4.000 4.000 Not Req'd Not Req'd Not Req'd 4.000 4.000 in
Max Vu 4.813 4.704 4.052 4.036 4.036 4.688 9.001 k
Bending &Shear Force Summary
Bending... Mn*Phi Mu,Eq.9-1 Mu,Eq.9-2 Mu,Eq.9-3
@ Center 13.35 k-ft 13.11 k-ft 9.83 k-ft 1.87 k-ft
@ Left End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
@ Right End 5.23 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
Shear... Vn*Phi Vu,Eq.9-1 Vu,Eq.9-2 Vu,Eq.9-3
@ Left End 36.64 k 4.81 k 3.61 k 0.91 k
@ Right End 36.64 k 6.80 k 9.00 k 1.16 k
Defiection
Deflections... Upward Downward
DL+[Bm Wt] 0.0000 in at 6.0000 It -0.0084 in at 3.00OOft
DL+LL+[Bm Wt] 0.0000 in at 6.0000 It -0.0552 in at 3.00OOft
DL+LL+ST+[Bm Wt] 0.0000 in at 6.0000 ft -0.0552 in at 3.00OOft
Reactions... @ Left 0 Riaht
DL+[Bm Wt]] 1.386 k 1.386 k
DL+LL+[Bm Wt] 3.386 k 3.386 k
DL+LL+ST+[Bm Wt] 3.386 k 3.386 k
Rev:510300 Concrete Rectangular & Tee Beam Design Page 2 .:
Description 8" CONCRETE SLAB
Section Analysis
Evaluate Moment Capacity... Center Left End Rlaht End
X:Neutral Axis 0.715 in 0.000 in 1.645 in
a=beta`Xneutral 0.608 in 0.000 in 1.398 in
Compression in Concrete 18.597 k 0.000 k 42.786 k
Sum[Steel comp.forces] 0.000 k 0.000 k 0.000 k
Tension in Reinforcing -18.600 k 0.000 k -42.363 k
Find Max As for Ductile Failure...
X-Balanced 5.844 in 0.000 in 1.3686 in
Xmax=Xbal'0.75 4.383 in 0.000 in 1.026 in
a-max=beta`Xbal 4.968 in 0.000 in 1.163 in
Compression in Concrete 114.009 k 0.000 k 26.698 k
Sum[Steel Comp Forces] 0.000 k 0.000 k 0.000 k
Total Compressive Force 114.009 k 0.000 k 26.698 k
AS Max=Tot Force/Fy 1.900 in2 0.000 in2 0.445 in2
Actual Tension As 0.310 OK 0.000 OK 0.000 OK
Additional Deflection Calcs
Neutral Axis 1.955 in Mcr 4.38 k-ft
Igross 512.00 in4 Ms:Max DL+LL 8.08 k-ft
]cracked 210.51 in4 R1 =(Ms:DL+LL)/Mcr 0.542
Elastic Modulus 3,122.0 ksi Ms:Max DL+LL+ST 8.08 k-ft
Fr=7.5`f'c^.5 410.792 psi R2=(Ms:DL+LL+ST)/Mcr 0.542
Z:Cracking 173.190 ksi I:eff... Ms(DL+LL) 258.612 in4
Z:cracking>145 :Interior Only I Leff...Ms(DL+LL+ST) 258.612 in4
Eff. Flange Width 12.00 in
ACI Factors (per ACI,applied internally to entered loads)
ACI 9-1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7 1.4"Factor 1.400
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9" Factor 0.900
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300
....seismic=ST' : 1.100
Rev:510300 Concrete Rectangular & 'Tee Beam Design Page 3 '
Description 8" CONCRETE SLAB
Sketch & Diagram IN
1.20 :I.80 2.40 .00 8.80 4.20 4.80 6.40 8.00 1.20 !1.80 2.40 8.00 3.80 13.20 13.60 5.40 8.00
Tk
T
o.Ss;k+iddrddddT s#d:Td add Td if-10i d:d 0.362k/tt o.00 E
ao 's
:2.13 r
......:.....:,-._. :1.80
53.19 i2 40Rft i
E
14.28 ! i ? : 13.19
Mu:Max=13.11 k4t Shear Load(k) Location Along Member(ft) Shear Load(k) Location Along Member(it)
Dmax=0.0552in 33.11 0.60 11.20 7.80 2.40 0 6.60 4.20 11.80 5.40 ¢.00 .83 P.60 9.20 h.80 2.40 -0.60 4.20 11.80 15 40 8.00
Rmax-3.3861, Rmax=3.38A1.80 ( 8.85
Vu-Max=4.813k Vu Max=9.09})549 7,87
4.87 3 Pi.90 S
0.58 °� E b92 y,1� :s�i•!
E N $83 un i
E.62 °. E i E �• E° 6 197 i ' i ' �•€1
BOURg Moment(k-try Location Along Member(ft) BeAft Moment(k-ft) Location Along Member(ft)
Beam Sketch Stresses for ACI 9-1 Combination Stresses for ACI 9-2 Combination
D 60 1.20 1.80 P 40 0.00 �60 )4.20 A.80 6.40 00 .20 -1.80 ,2.40 P.00 1.60 4.20 4.80 540 B.00 ' 20 h 80 0.40 8.00 960 A.20 0.80 6.40 8.00
0.00
0.35
02 2 02
3 +2.70 : t:2.70
i - - Shear Loatl (kJ cation Along Member/1t) Sh ar Load(k). •ocafin Ala Member(it).
0.48 I $.0t3_ D 80 y.zo_ 7.Bo 2. p.60 A.20 13.80 �.40 8.00 27 0.60 1 20 _1.80 2 4 .80 •4.20 '..60
..20 (40 8.00
-0.74 .. 7.27 27 i
10.99 i i -- -- -
_ $.48 _ 6 46
4.85
Shear Load(k) Loca_tiop Along Member(it)• A 04- I r r f 4.04
1.87 060 1,20 1.80 80 Ft 20 il 80 540_ 00 8.23 23 r
9.68 P.42
1.511 0
1.31 Be0. •i B.00e 7 ! Pit=
A.4
r0
401
002
0 03
-0 03
004
5 r :
i1.
:0.04 { -0 04 E
? 10.05 E._ k _ ?' e i .0 05
BeArRR9 Moment (k-ft) Location Along Member(ft) Local"y"Deflection(in) Location Along Member(ft) Local"y"Deflection(In), Location Along Member(it)
Stresses for ACI 9-3 Combination Stresses for Service Dead+Live Loads Stresses for Dead+Live+Short Term Loads
Rev'510300 Tilt-Up Wall Panel Design Page 1
Description 8" concrete wall
Loads
Lateral Loads Vertical Loads
Wind Load psf Uniform DL 670.00#!ft
Point Load 4,000.00 lbs Uniform LL 4,000.00#/ft
...height ft eccentricity in
...load type Wind Concentric DL lbs
Lateral Load 110.00#/ft Concentric LL lbs
...distance to top 6.000 ft
...distance to bot ft Seismic"I"Magnifier 1.000
...load type Seismic Wind"I"Magnifier 1.000
Wall Analysis
For Factored Load Stresses For Service Load Deflections
Seismic Wind Seismic Wind
Basic DO w/o P-Delta 0.001 0.000 in 0.001 0.000 in
Basic M w/o P-Delta 5,785.3 0.0 in-# 4,125.0 0.0 in-4
Moment Excess of Mer 0.0 0.0 in-# 0.0 0.0 in-#
Max. P-Delta Deflection 0.001 0.000 in 0.001 0.000 in
Max P-Delta Moment 5,793.5 0.0 in-# 4,129.8 0.0 in-#
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Req'd:SEISMIC 18.000 in
Maximum Allow Horizontal Bar Spacing 18.000 in Parapet Bar Spacing Req'd:WIND 18.000 in
Summary Wall Design OK
5.00ft clear height, O.00ft parapet, 8.00in thick with#5 bars at 12.00in on center,d=4.001n, f'c= 3,000.Opsi, F
Using: UBC Sec. 1914.0 method...Deflections are Iterated
Factored Load Bending :Seismic Load Governs Service Load Deflection :Seismic Load Governs
Maximum Iterated Moment:Mu 5,793.55 in-# Maximum Iterated Deflection 0.001 in
Moment Capacity 79,850.36 in-# Deflection Limit 0.400 in
Seismic Wind
Mn*Phi :Moment Capacity 79,850.36 in-# 79,850.36 in-#
Applied: Mu @ Mid-Span 5,793.55 in-# 0.00 in-#
Applied: Mu @ Top of Wall 0.00 in-# 0.00 in-#
Max Iterated Service Load Deflection 0.00 in 0.00 in
Actual Deflection Ratio 61,970 : 1 ###### :1
Actual Reinforcing Percentage 0.0065 0.0065
Allowable Max. Reinf. Percent=0.6*Rho Bal 0.0128 0.0128
Actual Axial Stress :(Pw+Po)!Ag 51.25 psi 51.25 psi
Allowable Axial Stress=0.04*f'c 120.00 psi 120.00 psi
Analysis Data
E 3,122,018.6 psi Sgross 128.000 in3
n=Es/Ec 9.29 Mcr=S*Fr 35,054.2 in-#
Fr Multiplier for sqrt(f'c) 5.000 Fr= 273.86 psi
Ht/Thk Ratio 7.50 Rho:Bar Reinf Pct 0.0214
Values for Mn Calculation... Seismic Wind
As:eff=[Pu:tot+AsFy]/Fy 0.411 in 0.411 in
a:(AsFy+Pu)/(.85 f'c b) 0.806 in 0.806 in
c=a/.85 0.948 in 0.948 in
Igross 512.000 in4 512.00 in4
Icracked 38.97 in4 38.97 in4
I-eff(ACI methods only) 0.00 in4 0.00 in4
Phi:Capacity Reduction 0.900 0.900
Mn=As:eff Fy(d-a/2) 88,722.63 in-# 88,722.63 in-#
Rev'510300 Tilt-Up Nall Panel Design Page 2 '
Description 8" concrete Wall
Additional Values
Loads used for analysis Factored Loads Seismic Wind
Wall Weight 100.000 psf Applied Axial Load 5,803.50 5,803.50 #/ft
Wall Wt*Wall Seismic Factor 0.000 psf Lateral Wall Weight 262.50 262.50 #/ft
Wall Wt*Parapet Seismic Factor 0.000 psf Total Lateral Loads 6,066.00 6,066.00#/ft
Service Applied Axial Load 4,670.00 #/ft
Service Wt @ Max Mom 250.00 #/ft
Total Service Axial Loads 4,920.00 #/ft
ACI Factors (per ACI,applied internally to entered loads)
ACI 9-1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4"Factor 1.400
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9"Factor 0.900
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300
....seismic=ST* 1.100 Roof DL 670.0 LL 4.000 Olbs. Ecc=0.00m
Sketch & Diagram
511
Eff.Width=12.0m
Seismic Factor=0.000
Seismic Zone=0
Fy=60.000psi
f'c=3.000ps1
Using:#5 @ 12.00in
Thick=8.00in
Design Method:1994 UBC 1914.0 w,Iterated Deflections
55
� s
Rev:510M Tilt-Up Wall Panel Design Page 1
Description 8"concrete wall
Loads
Lateral Loads Vertical toads
Wind Load psi Uniform DL 670.00#/ft
Point Load 4,000.00 lbs Uniform LL 4,000.00 Wit
...height it ...eccentricity in
...load type Wind Concentric DL lbs
Lateral Load 110.00#/ft Concentric LL lbs
...distance to top 6.000 ft
...distance to bot ft Seismic"I"Meni ier 1.000
...load type Seismic Wind"I"Magnifier 1.000
Wall Analysis
n or Factored Load Stresses
F For Service Load Deflections
Seismic Wind Seismic Wind
Basic Deft w/o P-Delta 0.001 0.000 in 0.001 0.000 in
Basic M w/o P-Delta 5,785.3 0.0 in4 4,125.0 0.0 in4
Moment Excess of Mcr 0.0 0.0 in4 0.0 0.0 in-#
Max.P-Delta Deflection 0.001 0.000 in 0.001 0.000 in
Max P-Delta Moment 5,793.5 0.0 in4 4,129.8 0.0 in4
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Req'd:SEISMIC 18.000 in
Maximum Allow Horizontal Bar Spacing 18.000 in Parapet Bar Spacing Req'd:WIND 18.000 in
Summary Wall Design OK
5.00ft clear height, O.00ft parapet,8.00in thick with#5 bars at 12.00in on center,d=4.001n,f'c=3,000.Opsi, F
Using: UBC Sec. 1914.0 method...Deflections are Iterated
Factored Load Bending :Seismic Load Governs Service Load Deflection :Seismic Load Governs
Maximum Iterated Moment:Mu 5,793.55 in4 Maximum Iterated Deflection 0.001 in
Moment Capacity 79,850.36 in4 Deflection Limit 0.400 in
Seismic Wind
Mn'Phi:Moment Capacity 79,850.36 in4 79,850.36 in-#
Applied: Mu @ Mid-Span 5,793.55 in4 0.00 in-#
Applied: Mu c@ Top of Wall 0.00 in4 0.00 in4
Max Iterated Service Load Deflection 0.00 in 0.00 in
Actual Deflection Ratio 61,970 :1 ###### :1
Actual Reinforcing Percentage 0.0065 0.0065
Allowable Max.Reinf.Percent=0.6'Rho Be] 0.0128 0.0128
Actual Axial Stress:(Pw+Po)/Ag 51.25 psi 51.25 psi
Allowable Axial Stress=0.04fc 120.00 psi 120.00 psi
Analysis Data
E 3,122,018.6 psi Sgross 128.000 in3
n=Es/Ec 9.29 Mcr=S'Fr 35,054.2 in4
Fr Multiplier for sqrt(f'c) 5.000 Fr= 273.86 psi
Ht/Thk Ratio 7.50 Rho:Bar Reinf Pct 0.0214
Values for Mn Calculation... Seismic Wind
As:eff=[Pu*tot+AsFy]/Fy 0.411 in 0.411 in
a:(AsFy+Pu)/(.85 f'c b) 0.806 in 0.806 in
c=a/.85 0.948 in 0.948 in
Igross 512.000 in4 512.00 in4
Icracked 38.97 1n4 38.97 in4
I-eff(ACI methods only) 0.00 in4 0.00 in4
Phi:Capacity Reduction 0.900 0.900
Mn=As:eff Fy(d-a/2) 88,722.63 in-# 88,722.63 in4
Rev:510300 Tilt-Up Wall Panel Design Page 2
i
Description 8"concrete wall
Additional Values
Loads,used for analysis Factored Loads Seismic Wind
Wall Weight 100.000 pst Applied Axial Load 5,803.50 5,803.50#/ft
Wall Wt'Wall Seismic Factor 0.000 psi Lateral Wall Weight 262.50 262.50#/ft
Wall Wt'Parapet Seismic Factor 0.000 psi Total Lateral Loads 6,066.00 6,066.00#/it
Service Applied Axial Load 4,670.00 #/ft
Service Wt @ Max Mom 250.00 #/ft
Total Service Axial Loads 4,920.00 #/ft
ACI Factors (per ACI,applied intemally to entered loads)
ACI 9 1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4"Factor 1.400
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9"Factor 0.900
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300
....seism is=ST': 1.100 Root DI.=870.0,LL=4,000.OIb%ECO=0.001rn
Sketch&Diagram
Sit
Eff.Width a 12.01n
Seismic Factor-0.000
S016mlo Zone-0
FY o30,000pe1
rc=3,000psi
Using:#5®12.00in
Thick=8.00in
Design Method:1094 UBC 1914.0 w/Iterated Deflections
k
\ti�
Rev:510300 Concrete Rectangular & Tee Beam Design Page '
Description CONCRETE BEAM
Reinforcing
Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam...
Count Size 'd'from Top Count Size 'd'from Top Count Size 'd'from Top
#1 2 5 9.88in #1 in #1 in
Uniform Loads
...
Dead Load Live Load Short Term Start End
#1 0.342 k k k 0.000 ft 4.670 ft
Concentrated Loads
Dead Load Live Load ShortTerm Location
#1 k 4.000 k k 0.000 ft
Summary Ij Beam Design OK
Span=4.67ft,Width=8.00in Depth=8.00ln
Maximum Moment:Mu 1.55 k-ft Maximum Deflection -0.0041 in
Allowable Moment:Mn*phi 25.01 k-ft
Maximum Shear:Vu 7.66 k Max Reaction @ Left 4.95 k
Allowable Shear:Vn*phi 33.66 k Max Reaction @ Right 0.95 k
Shear Stirrups...
Stirrup Area @ Section 0.220 in2
Region 0.000 0.778 1.557 2.335 3.113 3.892 4.670 ft
Max.Spacing 4.000 Not Req'd Not Req'd Not Req'd Not Req'd Not Req'd Not Req'd in
Max Vu 7.661 0.893 0.446 0.436 0.436 0.882 0.850 k
Bending &Shear Force Summary
Bending... Mn Ph1 Mu,Eq.9-1 Mu,Eq.9.2 Mu,Eq.9-3
@ Center 25.01 k-ft 1.55 k-ft 1.16 k-ft 1.00 k-ft
@ Left End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
@ Right End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
Shear... Vn*Phl Vu,Eq.9-1 Vu,Eq.9-2 Vu,Eq.9-3
@ Left End 33.66 k 7.66 k 5.75 k 0.55 k
@ Right End 5.96 k 0.85 k 0.64 k 0.55 k
Deflection
Deflections... Lloward Downward
DL+[Bm Wt] 0.0000 in at 4.6700 ft -0.0041 in at 2.3350ft
DL+LL+[Bm Wt] 0.0000 in at 4.6700 ft -0.0041 in at 2.3350ft
DL+LL+ST+[Bm Wt] 0.0000 in at 4.6700 ft -0.0041 in at 2.3350 ft
Reactions... Ccs Left Ccs Right
DL+[Bm Wt]] 0.949 k 0.949 k
DL+LL+[em Wt] 4.949 k 0.949 k
DL+LL+ST+[Bm Wt] 4.949 k 0.949 k
Section Analysis
Evaluate Moment Capacity... Center Left End Right End
X:Neutral Axis 2.145 in 0.000 in 0.000 in
a=beta*Xneutral 1.823 in 0.000 in 0.000 in
Compression in Concrete 37.194 k 0.000 k 0.000 k
Sum[Steel comp.forces] 0.000 k 0.000 k 0.000 k
Tension in Reinforcing -37.200 k 0.000 k 0.000 k
Find Max As for Ductile Failure...
X-Balanced 5.844 in 0.000 in 0.0000 in
Xmax=Xbal'0.75 4.383 in 0.000 in 0.000 in
a-max=beta'Xbal 4.968 in 0.000 in 0.000 in
Compression in Concrete 76.006 k 0.000 k 0.000 k
Sum[Steel Comp Forces] 0.000 k 0.000 k 0.000 k
Total Compressive Force 76.006 k 0.000 k 0.000 k
AS Max=Tot Force/Fy 1.267 in2 0.000 in2 0.000 in2
Actual Tension As 0.620 OK 0.000 OK 0.000 OK
SII!}Ar
...... ...... ..`_s.^.�•a _,...��x._a�s,�a_�:u.vis,.a...:�:._. .._._.._� .—_�. � : _�•_.___�.� -m�srs;.yy�,•�.�
1
• •• 1 1
1 • 1
•
• •o :•• o• • o - c• •'•
1— X11 • e • 1 1 • •11
�Amm
1 1 /o:• •.• • 1 .1 1 1 • 1 .1 1
11 • - • 11
11
I I\����IIIII�III�IIIII�IIIII� Il�illll \��������
MRSOMMIUMMEN
amEMIMMEMN�� mmmmmmm��IN'I
QMMMMM E MaNMEMMEEMIN r
� 61IIIpii3llu mail ` p �a7 ".II1161rnTllll�iilldlilipillilllii�Tlilllx�
���I�IIIIIIIIIIIIIIII@➢IIIIINIIIIIIIIIN1i�� � ���,mIIIIIIIIIRIIIIIIIIIIIIIIIIIIIIIIIdN1111111111,1111P'IIIIIIIIIIINIIIiI�t���
IINIIIINIII@I@III�IIIIIIIII@IIIIIIIIIINIIIIIIIIIII�I@I11��001 &�� IIIIIIII@iIIIIUNIIINIIIIIIIIIIIIIII�IiIIIII11199111gIN@NIIIIIIIIIIIIIIICI'.Illpkllf ��
�7��fIIIIIIIINJIIIIINIIIIN11111111111R11111111NIIIIIIIIIIIIIIINI�ININI�N�� �l�'IIgNINNINIId11Nll'IIIIIIIIIIIIIIII�IIIIIINIIIIIIIIIII'VIIIIIIIIIINNNIiIIIIJIIJIIIN11�1A•�
al�iIIIIIIIIIIIIIIIIN1111111111NIININIIIIWl�91�@IIII9INII��ININIINININIIIq'Nlul�� ��'ll'IIIIIdIINIIIIIIIIIIIIIiNIVl�ldl'NI�dI�IItlIIINIIIIIIIIVIIIIVIIIIIllll9!II!IIN6INIIIIVIINIII&I@II'llNll��
��INl11II!IRIII'II'IIIIIIIIIIIIINIINII�INIIIIIIIIII�IIIIIIIIIIII�IiINIIIININNI plNll�� ��filllll@IINNNIIIIdII:III@G1111NI@PIdVINIIIINI!Ipl'NIIIIIINIIIVIIIII6111'llllll!IIIINI'11111@III�IIIdIININIIINllll6�
�111VIIINGIII''plllYll'IIIIIIIIINNIILNNNIIIIIIIWIII@IN�MIIIINII�fIIIII�NIgI��NIIINIIi� '� IIIIIIIIIIIIIIIIIIVIIIINIIIII'IpdIININIIIIIIIIiNIIIIIiNIIIIIIIIIUIIIIINIIIIIIIIVIIVIIIIVIIIIdII''III'I'IINIIIIIIIIIIINPII@IIBIINIIIII'tl
�IINIIIIIIII'III'IICUINIII111''IIIMNINIIININI�IINIIIIIIIII��NII9 NIINIUIININIIN�NI�NNIIII� �IIINIIIIIIIIIIIIdNllllllllllNNII!III@INIIINIIIIIIINIINIIIIiI@111iIINIIINIIIIIIIIIIIIIIIINPIIPlllll@IIIIIIIIIIINIIIIIIINII
IIIIfIINIIIIIIIIIiIIIIIIIIIILIl11111NIINi111N1!IIINIIII@IIIIINI9111���INNIIII�I�IN�N�INIpNINllllll � VIII@II@IIIIPIIIIIIIIIIINIINIII'IgINdllGllll@INIINIIIIIIIIIIIIIIII'NIII!IIIIIIIItIIIIIIIIIIIIIIIV'IIIIIN!IIIIIIIiIINII@11111@'III�IIINIIIINIIIMI�
� �I{�IIIIIIIIIIIIIIIIIIIIINII�L111111':ILII@IR1111111NINIIIIIIIIIIIIIIN�BINNNIImIININNNINIIINNIIIIINIIIII� ���''IINIIIINIIIIIIIIIIIIIIINNII�@1111NJJINNI1111111111111111111PdIIGIINUII�IIIIIIIIIIIIIIIIIIVIIUIIIII'III�IIIINIIJI@IIINII@I@INII'NNIIIIIIIINII�III�I
,1V1�L�lil'lI`I
11•....... I __ II I
I�I I � SII ' III I��II�IILlllllllil I.�--
p:I`I 'i I�I�I1NI-M��� ��__�_�_�II`��T��°�''I �����II11r:NT Qqi 1 III Ell
NOME
r r:r ����III�I�I�III!�I Illl�lllf IIIII1I I�I I IIIA - ��� �'ll� 1�1��`�II`'li�i`IN'I���
- - Illll� llr„ IIIIII' !�`taYl��b Tlrilllllll'.lAv :�� l[I�'?E7� b 7rii l dllllll'4 willm � lrW
� - _
,'--_N__ 7�'!1•__!'TnlulululuilllunimuuillluimillullAillluS __ '1[;7__!fl;gill%INlllulllllu%Nuumm�iEllulVllllllNNl%IIIIIIG7 __
1['�_!R%IIQIIIIIIIIIIInIIIIII11111111NIIW911111111111111111Iil�lllllallhl.�__ 3'")•_�fIIIIIIIIIICIIIIId11116111111111111611111111IIIIIIIIIIIIIIIIIIIIIIV116Nillllillll%�__
"a��������1` ��_!RlulluuuoulorllNlnilmlluflun%m+xllllluuuulul%uinI1�IN1uuI1T__ ]Fi7_Tf191uu1xmVIiIIVI%ouNllulu�Ylu�oVugNlumlilrlNluullnllNUIIIIIIIILIInIumllClluulNl:�_
7L•T�lNllllllllwllllllllllllllllllfllllll!Iilllllllllllllllllll%III%I%IIIIIRIIIIIIIfMl111911111f__ 7I•T_'��IIII'11111%11111NIIm!IIIIBIII9'IIIIIPIIIIIIlAIm14IIIIIIIIIIIIIIIIIIIIIIIIIII;IIIIIIIIIIIIIIIIIIIIiIIfIINNII!IIIIIIIIIII•#_
7•'fifIIIIIIIIIIIIdIIIIIIIIIIIIIIIIIifIIIIIIIIIIIIIIIIIIIIIIIIIII111WII1111111111GIII110a11111urIIIIRII 7 ��fiIIIIpVCIPllllll%IIIIGII%NI4111'lllAllllal11111111911111111111111111116111illlllilillllllllllllllllll'II%IINIIIIIiIIiPIIIVIIflII _
'r�`''�" 9C5�I�IIIIIIIIIIIIIII111111111111111111!IIIIIIIINIIIwI!IIII%Illillllllll%IIAIIIIIIIIIRIIIIN111MIlulll1111111111_ 967lfilllllllllllllVlllnIRNIINIIIVAIYIIIIIIIIIIIIII,ICIIIIII!IIIIVIIIIIIIIIIIIIiIIIIIIVIIIIIIIII'IIIIIINIII%Illllllllm'1171111i11%wllllll%_
��aa•`, ".IiI�Wi�dlll�mmaoVu�uo-n�irn7��1�i7 ` �uuuuuullllufuVlllluluulduVllullluululllVlllllllumlllugnlm%BIIIOIIIMI�llllllllll�uullElulfl� �71!fllxiullollull111ullflll,mrflllllT,w�l111uuuuiuVluuu%V:ullmllllluuuuulNUllluuP,IIrIICIIImuIIIUPImP%INIIIPukCI11NY191911G_
&allllllllllllllllllllfilll@INNII@I@INII9NNIINIIIIIIINIINIIIIIIIIIIIIIII�11�111111111111111111 �-ollllluluullollllllllNilNlulllmnlullluullllrlfnNnuumW%%uunuWnNllmll®I�In111m11Rl�ulllllluuln� x%anun6muunnu1111mo111iuu�mN4unmloV%NNuuVVllmrcuNVNuuNUNVUINnIUNuuplunNIIROIINnIuumNm%61m%rc%mI11uI11SwIN91!
37�111111NIIIIINNIIIINIIIIIINI@IIN@IN@INNNINNNINIIIIINNINNNNIN■IIIIII�IIIIII� �"hllllllllllVIVIIIIIIIIIhIIII'IYIIIIIIIIIIIIII%IIIIIII111111111NINlnNlulumouuuunlJlluuVl®IIfl11�lNlllululllllnol111 7�ilallNutlmlluuull111mIINmlruld%omullxllVl%ullllNllllN'lIRl6'CVllllu%IlluullullulluflulluuclllxuN%mlYm%munluullllllxllll%1111Mn
IIIIIIIIIIIdINl9111@II@N@IN@@I@INI@NNI@INNNgIINIIIIIIIilllll�lllllll@NllIIIIA•� k' _ ." k
' � ��_llllllllrl hlllllkl.lC .11IIIISIH...11nllia.lallnu.k.».11R1._I_11a i.�14�frAtlll:11�:9111x a(:11111WI!ll Iru01N..4...INdlml.%t,11111111111.-BmIIIIIL77,IIIIII%..IL.,.LIIIIiI,.xl%,VVImIL-1GC311MIu.}.�•�I191I
i I�IIIIIIII:I'IIIIIIIIIIIIIIIG111111!IEIIIIIIIfi111111111iIIIIIIIJ1111111111%IINIIIIIIIIIIIIMIIIIfl111Y1%lull®®u1111�II11Nx11111�
���IIIII1N@INNlIl@liI@@III@II1@11I1I1I1N1@INIfI1I1INNIINNVIiIII@NIII@III@@I1I1N1I1I8IIIIIIIIIIIIIIIIIINIIIIINIIIIIIII@NIIINIIIIIIIIII�IIIIIIIIIIIIIIIIIINNdNII@NN'I1@11111111@@NINI!N�h�I��
!7[]YVII!V'llllllllllllllll'IIIIIIIIIIIIIIII6II411111111VIIVIGIIfllllllilldllllllllllll11111111%�®IMIIIIIIIIIW�1111_ r�7CI{'rIYnuu9IIlIiIn1�1%11I1I1I1U1I11I11Niullulllmllmxouul6lGilllouuulxL ulluIu�lullVUNr�[u,l.ulull'ulullroumr� Iul%I%IIOIIIIIIINMJIIUllmmAIW11111_19N1•
1
��►IIIIIII1t4V4VlllNlollulllu,uuuulllll%IIiII1n111111iIINumlllVlllllll%nlll®IIWIn11n11W11AIM1U_ :rEr:7Y1JIInVutlNmlouollkhlolluu%In41fklVllmuul,IltlIloVIUIIWull6111111lnluill%%lmlullll.ullllu9%IVluunm%IIIIV_
tllllllllllllglllNlgINIIIIIINI@IIEI�II@IIN@INIpIIIIIIIIIIIIIiNNNlllllllllll11111111NIIINIL1111911NIIJI
11
7C7WfIIIIV ®Nlrt_ rlxG1081V%IIVIINIIIIIIIIII%IIINII%IIIIIIIVIIIfIIIIIVIIINIIillllllllllllllllIiIIiIIIIIIIIIIIIINIIIIIIIIIIIIIIIIIIIII'IIIIIIIINIIIIIRIIIIIIII�_
!fi1�'ll!WIIIIIIICIIIIIillfxl:III%fIIIIIIIIIIIIIIIWIINl1Wll%nI111NII11111111W11Elllll111111__ AF�_illlmuolllul%IIINIlo11lINIIIIu1141fII;coININUI'INllu%uuIIIIIIIINulllluimmllll'uialllkl%[urIVli__
IgINNININIIIININ�111N@NIiIIIIINIINIINIINIIIINNIINIIIIIIIINNNIIIIIIIIIIIIIII@IIIIIIII@IIIIIgINllIN9@11111NI _ruNo-lollulnlllVllooNn%I lltmnluuullnnlllnluuuuelnunusl__ rT7R_11uu%rm%Ifl1,Nlul111lla%r:NUIININIimluNl%INNII'IUWIUINIIIImIIWI!Nu�1__
SIN@fI1NIIIIIINININI@11p@IIIIIIIIIIIIIIIIIIN6INIINII@I911i111NIIIIIINIIIIIIIIIINg1111111gNINNIIINIIINNIIplldllfpllNlN� = — IrIIIIIIIIIIIIIIIIIIIuIIIII+II,+xIIIUIIlII1111i11+llllall+llu.-- :rXI INO n'ullwllmll'IIIIIIUIIIufII!IfIIIIIIIIIIII!IIfIIIIIIII'IIIIIIII+IInl+llllIumm�
�b�IIIINI111111111NII111N1@IINIIIN@VIII@IN'NNIIII�I@INIIUNNIIIIIINIIIIIIIIII�@IIIIIIIII@IIIIIIIINNIgNI@I11�pollllll!CtllliNf -,'r�'�_'���'�Iu°IIII°°Il°I%°'l°all%°°°°°°Ilmuu��__ �__rxuu�ullllulrullNNllNliuNlullulluunll;lu'ullwu___
�YlWIIWaIII%nlNlllllllJC____ ��__ I�IIgIIIINIIIIIIIIIIIIIIIIIIIIIIlL1Wir___
/ to
1 ;
CITY
RATIONAL ANALYSIS AND ENGINEERING DESA ONS
FL GRIDA .8 UILDING CODE 2 010
NEW SOAK PIT FOR SHORE VILLA CONDO
UNIT AT 9017 NORTHEAST 4TH AVENUE ROAD ......
MIAMI SHORES, FLORIDA 331A. ..•...
DATE:08-06-2013 666:00 0000 •
......
TABLES OF CONTENTS: .000••• •••• •••••
1. RETAINING WALL AND FOOTING DESIGN PIGES;19'•• 00.0.
2. 8"X8"CONCRETE BEAM DESIGN PAGES 6'7 •••• ••••••
3. 8"CONCRETE SLAB DESIGN PAGES 8-10•;•; ••
4. 8"CONCRETE WALL DESIGN PAGES 11-12 0.••0• ••••••
• • • •0000•
CHARLES C.MITCHELL-CONSULTING ENGINEER ASSUMES RESPONSIBILITY POR BOTH M4XU'AL •
AND COMPUTER GENERATED CALCULATIONS.
CHARLES C.MITCHELL-CONSULTING ENGINEER.
P.E.#11127
924 NORTH FEDERAL HIGHWAY
HOLLYWOOD,FLORIDA 33023
TOTAL PAGES :12
% s Mir'-., ✓�
l
CJ <*
* No. 1.1127 =
STATE OF
i -0 k
i
O •.... ,Q: �.
' ..OR•.... co
S,O N A,,`�``��
• a
CHARLES C. MITCHELL P.E.
P.E. 0011127 SOAK PIT FOR SHORE VILLA CONDO UNIT
C5.020 ng Engineer5.628 AT 9017 NE 4TH AVE. RD
305.945.0202 / 305.828.0140
1515 n.w. 167 th Street Suite 110-r MIAMI SHORES, FL 33138
MIAMI, FLORIDA 33169
....:....:....:..
'000:0••
• •• 0000• •• •
•• '••o• •000'•0
....:....:.....: ...:.........:....:....:..
• •i :••is :000'0••
: . . :
:. .. ..
�.�•.
.. ..
.... .;....:.. .��... .... ... :....if............. ....... .... .... ...;. ..;.... .. . .... .... .... ....;.... ....;...
:....:....:....:........................
:....•.
: ...:..............
fel .
. .. %. rte.. . '� .,sGt.
....:....:....:.... .... ....:....j....:....:....;....;....:....:....:....:....:....:....:....:....:....
-
. .
sf ... .. , - ...: � G IJT.......:....:.... ....:...
...
..........
:. fes..:......... . ...-....a 3 _
✓...- Z....:'..c •�l..;X '3�iZ,0Ctk' .fr /33.3 .?i ' ..... ````� sMi
..
to
........................
•���a M8'••.
to
.... .... .... ....
"0 arae OF.it
:. .., ... .((. ONA
. ��:'��•: �:� CYT': �6 ''��ii�i 11������
e a
Rev:5103M Restrained Retaining Wall Design Page 1
Description
Criteria Soil Data Footing Strengths&Dimensions
Retained Height = 5.00 ft Allow Soil Bearing = 2,000.0 psf Pc = 3,000 psi Fy = 60,000 psi
Wall height above soil = 0.00 ft Equivalent Fluid Pressure Method Min.As% = 0.0014
Total Wall Height = 5.00 ft Heel Active Pressure = 0.0 Toe Width = 0.83 It
Toe Active Pressure = 0.0 Heel Width = 1.50
Top Support Height = 5.00 It Passive Pressure = 0.0 Total Footing Width =
Water height over heel = 0.0 ft
Slope Behind Wal = 0.00: 1 Footing Thickness = 12.00 in
Footing��Soil Frictior = 0.300
Height of Soil over Toe = 60.00 in Key Width = 0.00 in
Soil Dens' = 110.00 cf Soil height t0 ignore Key Depth = 0.00 in
� _p for passive pressure - 0.00 in
Key Distance from Toto.s-. 0.00 it
Wind on Stem = 110.0 psf Cover @ Jbg = 3.001r?•@ Btm.*15W. in
00 . . ..0
Surcharge Loads Uniform Lateral Load Applied toStem Adiat$ffI7+tfbting Loba • ••••••
Surcharge Over Heel = 0.0 psf Lateral Load = 0.0#/ft Adjac Fpoting Load..
as>NOT Used To Resist Sliding&Overturn ,,.Height to Top = 6.00 it Footing Width • • 0 001
Surcharge Over Toe = 0.0 psf ,..Height to Bolton• = 0.00 It Eccen nc�+ = ?Min*.
NOT Used for Sliding&Overturning Walllo EPg dl-Dist : .'_'. effif
Axial Load Applied to Stem Footlh§type •••• Line'L•okib:
•
Axial Dead Load = 366.0 lbs Base Alwve/pelow Soil
at back of�VVall . ; .0.0�i •
Axial Live Load = 1,833.0 Itis, 0000..
Axial Load Eccentricity = 0.0 in •• •• 0• •000.•
•
•
.. • 0000 0 0
Desi n Surnmary Concrete Stem Construction 06;6
Total Bearing Load = 3,935 lbs Thickness = 8.00 in Fy = 60,000 psi
...resultant ecc. = 0.00 in Wall Weight = 96.7 pcf Pc = 3,000 psi
Soil Pressure @ Toe = 1,689 psf OK Stem is FIXED to top of footing
Soil Pressure @ Heel = 1,689 psf OK
Allowable = 2,000 psf Mmax Between
Soil Pressure Less Than Allowable @ Top Support Top&Base @ Base of Wall
ACI Factored @ Toe = 2,600 psf Stem OK Stem OK Stem OK
ACI Factored @Heel = 2,600 psf Design height = 5.00 ft 0.00 ft 0.00 ft
Footing Shear @ Toe = 13.2 psi OK Rebar Size # 5 # 5 # 5
Footing Shear @ Heel = 8.0 psi OK Rebar Spacing = 12.00 in 12.00 in 12.00 in
Allowable = 93.1 psi Rebar Placed at = Center Center Center
Reaction at Top = lbs Rebar Depth 'd' = 4.00 in 4.00 in 4.00 in
Reaction at Bottom = 0.0 Itis Design Data
fb/FB+fa/Fa = 0.000 0.000 0.000
Sliding Calcs Slab Resists All Slidingg! Mu....Actual
Later = 0.0 1114 0.0 ft_# 0.0 ft-#
Lateral Sliding Force = 0.0 lbs Mn"Phi.....Allowable = 5,154.8 ft-# 5,154.8 ft-# 5,154.8 ft-#
Shear Force @ this height = 0.0 lbs 0.0 lbs
Shear.....Actual = 0.00 psi 0.00 psi
_ Shear....Allowable = 93.11 psi 93.11 psi
Footing Design Results Rebar Lap Required = 21.36 in 21.36 in
Ice eel Rebar embedment into footing = 6.00 in
Factored Pressure = _2_,6__0b 2,600 psf Other Acceptable Sizes&Spacings:
Mu':Upward = 899 0 ft_# Toe:#5 @ 18.00 in -or- Not req'd,Mu<S•Fr
Mu':Downward = 339 339 ft-# Heel:#5 @ 18.00 in -or- Not req'd,Mu<S•Fr
Mu: Design = 560 339 ft-# Key: No key defined -or- No key defined
Actual 1-Way Shear = 13.21 7.99 psi
Allow 1-Way Shear = 93.11 93.11 psi
w
Rev:510300 Restrained Retaining Wall Design Page 2
Description
Summaa of Forces on Footing : Slab RESISTS slidin ,stem is FIXED at footing
Forces acting on footing for Boll pressure »>Sliding Forces are restrained by the adjacent slab
Load&Moment Summary For Footing:For Soll Pressure Calcs
Moment @ Top of Footing Applied from Stem = ft-#
Surcharge Over Heel lbs It ft-#
Axial Dead Load on Stem 2,199.0 lbs 1.17 ft 2,561.8 ft-#
Soil Over Toe = 457.4 lbs 0.42 It 190.2 ft-#
Surcharge Over Toe = lbs ft ft-#
Stem Weight = 483.3 lbs 1.17 ft 563.1 ft-#
Soil Over Heel = 457.4 lbs 1.91 ft 875.6 ft-# *see
Footing Weight = 337.9 lbs 1.17 ft 393.6 ft-# . • '•...'
Total Vertical Force 3,935.0 lbs Base Moment = 4,584.3 ft-# •• : • ..• •
.....• •• . •.•..•
Soil Pressure Resulting Moment= -o.Cfta# •
•••• •••• • •
•••• •••• •••••
•••••• • •• •••••
•• •• •••• ••••••
•
• • • •
8.0 ••••
• • ••••••
Lateral Restraint • • •Gs• •
0.# • *.so
• •
••• •• • ••••••
•
Goes •oGs :Goes:
ee•0 0000 eG•0•
8.00005"ConcreN4V7 115 @ 12." 5'-0" 5'-0' • a'-0" . • G
G
8.00005"Concrete w/ 5 @ 12." 3" e • :••• • •
*so*
Sliding Restraint
• • 1'-0,.
3"
#5@18.in
@Toe
#5@18.in 10" 1'-6"
@ Heel
2'-4"
DL=366.,LL=1833.49999990.0005#, Ecc=0.0005in
• • 0000 0000••
•• • • ••• •
Lateral Restraint • • • •
0000•• •• • 0000••
•
.0000• • • •
0.# 0000••
0000 0000 • •
00 0
0000 0000 0000•
0000•• • •• .0000
•• .• 0000 0000••
0000•• • •
•
• • • • 00.0.0
0000••
• • • 0000••
•
0000
Sliding Restraint
Pp=0.#
0,#
1688.8psf
1688.8psf
. . ... . . . ...
.. .. . . . .. .. .
. . . . . . . . . .
. . ... . . . . ...
. . . . . . . .. .
. . .. . . . . . . . . .
. . . . . .. . ...
• • • • • • • • • 22'CAST IRON FRAME&COVER WI GASKET
• STANDARD ACCESS MANHOLES
.. . . . .. ... .. V ASPHALTIC CONC.WI 6°THICK CRUSHED LIMEROCK
•. i.i i i i i i. . COMPACTED TO 9504 DENSITY
• 8°THICK TRAFFIC LID WI#5 REBARS MAT
.. . . . . . . ..
&SOUTH)
=111=1 I 1=III = B°X r CROSS BEAM @ 72°O.C.(SEE BEAM PLAN)
1=1 I I=I I 1=I I • • • _ 1-10. ___• __ . ._ III I W12-#5 KEBABS EMBEDDED 6"INTO 8°CONC.WALL
=111=1 I I=1 I I _ _ I — III= ON EACH SIDE
01 — _ _
ELI =1 I I:E ILI=
-- ---------------- — _ — — —
I °O I I�I 1�I- 8°CONC.WALL WI#5 KEBABS @ 12°O.C.VERTICAL&
� I , III— I I—III=
-I I—I 11—I I—III—I I—I I , I. 1 I—I I—I _ III__
HORIZONTAL
Ed I I—I I Ed I El I I—I I I I I I Ell —_-111— I I—�I
-1 I I-1 11=1I I=1 11=I I I—I I I I = I I—I I1=11 II I I—
I-1 I I—I I I—I I I—I I I—I I I I El =I I MI I— I I=�I
-III—I I—III—I I—III—I I=I 11-11 I=I I GRADE
I—II1=1II-1I1=III—III 1II—II—_ —I
I I-1�I—_—I 11 I�I—
—I I I—I I I—I I I—I I I—I I I j I I I—I 11—I 11= I I—�I
I—I I I=I 11—I I I , I 1—I I I—I I VI 11XI-
1=111—III=111-1 I I—I I I I I 11=1 I I—I I I= I
-IIF—III—II1=1II—III=1I •I I• I 1=11 I=IIIEEII Ell IEMI I I-1 I MII—II1-1 I I I I I I MI 11=III— 11=�I
-I I E111—I I El I El 11=I I I ElIElII—III I I E
1-1 I mlIi—III-111=1 I I I I 111=1 I I=I I I— I I—I I
-III—III=1 11-1 11=III-1 I RIffiEl El 11-111=111-1 —1 I I • • 1111=III= 111— 17 X 16'CONC.FOUNDATION WI 2-#5 REBARS CONTINUOUS
-III-11I—II1-11I = )
1=1 11411�=111'4
— _—III- I I—I II
III-11III111-1 I I—III 111= 1"BALLAST RFK BASE
=111 = �_ _ I I F=1 11= I I _
Rev:5103M Tilt-Up Wall Panel Design Page 1
Description 8"concrete wall
Loads
Lateral Loads Vertical Loads
Wind Load psf Uniform DL 670.00#/ft
Point Load 4,000.00 lbs Uniform LL 4,000.00#/ft
...height ft ...eccentricity in
...load type Wind Concentric DL lbs
Lateral Load 110.00#/ft Concentric LL lbs
.-distance to top 6.000 ft
...distance to bot ft Seismic"I"Magnifier 1.000
...load type Seismic Wind"I"Magnifier 1.000
some
Wall Analysis •
For Facto11 red Load Stresses For SsrvicerLoad Deileatisu�s
Seismic Wind Seismic.. '. VjLtncr; 0000;.
Basic Dell w/o P-Delta 0.001 0.000 in QOQ1 0.000 in
Basic M w/o P-Delta 5,785.3 0.0 in-# '$,1�5.Q ' 0.0 in-#:.•••:
Moment Excess of Mcr 0.0 0.0 in-# ••••0'Q ••••g.0 in-#• •
Max.P-Delta Deflection 0.001 0.000 in •oAoi ••4000 in .••.•
Max P-Delta Moment 5,793.5 0.0 in4 .4JIM 0 000.0 in-#..;.0•
Maximum Allow Vertical Bar Spacing 18.000 in Parapet Bar Spacing Regki-SOSMIC ••:••18.000 ins•••••
Maximum Allow Horizontal Bar Spacing 18.000 in Parapet Bar Spacing Req;o,; J(INp 0 18.000 in .'
Summary
. WiPDbSfgn O!� .
. 0000
5.00ft clear height, O.00ft parapet,8.00in thick with#5 bars at 12.00in on center,d=4b0in,f'c=3,V00!Opsi, f •
Using: UBC Sec. 1914.0 method...Deflections are Iterated 0000
Factored Load Bending :Seismic Load Governs Service Load Deflection :Seismic Load Governs
Maximum Iterated Moment:Mu 5,793.55 in-# Maximum Iterated Deflection 0.001 in
Moment Capacity 79,850.36 in4 Deflection Limit 0.400 in
Seismic Wind
Mn`Phi:Moment Capacity 79,850.36 in4 79,850.36 in4
Applied: Mu @ Mid-Span 5,793.55 in4 0.00 in4
Applied: Mu @ Top of Wall 0.00 in4 0.00 in4
Max Iterated Service Load Deflection 0.00 in 0.00 in
Actual Deflection Ratio 61,970 :1 ###### :1
Actual Reinforcing Percentage 0.0065 0.0065
Allowable Max.Reinf.Percent=0.6'Rho Bal 0.0128 0.0128
Actual Axial Stress:(Pw+Po)/Ag 51.25 psi 51.25 psi
Allowable Axial Stress=0.04'f c 120.00 psi 120.00 psi
Analysis Data
E 3,122,018.6 psi Sgross 128.000 in3
n=Es/Ec 9.29 Mcr=S'Fr 35,054.2 in4
Fr Multiplier for sqrt(fc) 5.000 Fr= 273.86 psi
Ht/Thk Ratio 7.50 Rho:Bar Reinf Pct 0.0214
Values for Mn Calculation... Seismic Wind
As:eff=[Pu-tot+AsFy]/Fy 0.411 in 0.411 in
a:(AsFy+Pu)/(.85 f'c b) 0.806 in 0.806 in
c=a/.85 0.948 in 0.948 in
Igross 512.000 in4 512.00 in4
Icracked 38.97 in4 38.97 in4
I-eff(ACI methods only) 0.00 in4 0.00 in4
Phi:Capacity Reduction 0.900 0.900
Mn=As:eff Fy(d-a/2) 88,722.63 in-# 88,722.63 in-#
Rev:510300 Tilt-Up Wall Panel Design Page 2
Description 8"concrete wall
Additional Values
Loads used for analysis Factored Loads
Walt Weight 100.000 psf Seismic —Wind
Walt Wt'Wall Seismic Factor 0.000 psf Applied Axial Load 5,803.50 5,803 50#/ft
Wall Wt`Parapet Seismic Factor 0.000 psi Lateral Wall Weight 262.50 262.50 Wit
Service Applied Axial Load 4,670.00 #/ft Total Lateral Loads 6,066.00 6,066.00#/ft
Service Wt @ Max Mom 250.00 #/ft
Total Service Axial Loads 4,920.00 #/ft
ACI Factors (per ACI,applied internally to entered toads)
ACI 9-1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 19?1.2.7;1.4"Fac?gr...• 1.4q0 ....
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921 "Q.9"Fact qr ... 0.900 •
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300 • • • •
....seismic=ST': 1.100
Roof Dt.a(Nd1b. A4,000.Obs,E&I 0.001AD 000060
Sketch&Diagram ••••
.... .... . .
...... . .. ....
.. •• •••• •••• •
• • •••• •
•
••••
5ft
E8.Width o 12.01n
Seismic Factor o 0.000
Seismic Zone=0
Fy=80,000psi
Pc=3,000pal
Using:#5®12.00In
Thick-8.00In
Design Method:1994 UBC 1914.0 w/Iterated Deflections
Rev:510M Concrete Rectangular & Tee Beam Design Page 1
Description 8"CONCRETE SLAB
Reinforcing
Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam...
Count Size 'd'from Top Count Size 'd'from Top Count Size 'd'from Top
#1 1 5 9.88in #1 in #1 in
#3 in #3 in #3 2 7 2.31 in
Uniform Loads
Dead Load Live Load Short Term Start End
#1 0.362 k k k 0.000 ft 6.000 ft
Concentrated Loads •
. . .... .... .
Dead Load Live Load Short Term •• •Loc_at • ••• •
#1 k 4.000 k k •••i•• 3.00O�t• • ����•�
Summary •••• Beaq?5b%gn OK •
Span=6.00ft,Width=12.00in Depth=8.00in • • :• •
•••••• • •• • •••
Maximum Moment:Mu 13.11 k-ft
Allowable Moment:Mn"phi 13.35 k-ft Maximum Deflection ••••A552 in •:•• • ••..
•
Maximum Shear:Vu 9.00 k Max Reaction @ Left :0•:•:3.39 k •
Allowable Shear:Vn•phi 36.64 k Max Reaction @ Right • 0 3.39 k:•••:•
Shear Stirrups... • • • :8000:
Stirrup Area @ Section 0.220 in2 " ' :000
Region 0.000 1.000 2.000 3.000 4.000 5.000 04"0 ft
Max.Spacing 4.000 4.000 Not Req'd Not Req'd Not Req'd 4.000 4.000 in
Max Vu 4.813 4.704 4.052 4.036 4.036 4.688 9.001 k
Bending &Shear Force Summary
Bending... Mn•Phi Mu,Eq.9-1 Mu,Eq.9-2 Mu,Eq.9-3
@ Center 13.35 k-ft 13.11 k-ft 9.83 k-ft 1.87 k-ft
@ Left End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
@ Right End 5.23 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
Shear... Vn"Phi Vu,Eq.9-1 Vu,Eq.9-2 Vu,Eq.94
@ Left End 36.64 k 4.81 k 3.61 k 0.91 k
@ Right End 36.64 k 6.80 k 9.00 k 1.16 k
Deflection
Deflections... Lloward Downward
DL+[Bm Wt] 0.0000 in at 6.0000 ft -0.0084 in at 3.00OOft
DL+LL+[Bm Wt] 0.0000 in at 6.0000 ft -0.0552 in at 3.00OOft
DL+LL+ST+[Bm Wt] 0.0000 in at 6.0000 ft -0.0552 in at 3.0000 ft
Reactions... Ccs Left Ca Right
DL+[Bm Wt]] 1.386 k 1.386 k
DL+LL+[Bm Wt] 3.386 k 3.386 k
DL+LL+ST+[Bm Wt] 3.386 k 3.386 k
G J
Rev:510300 Concrete Rectangular & Tee Beam Design Page 2
Description 8"CONCRETE SLAB
Section Analysis
Evaluate Moment Capacity... Center Left End Right End
X:Neutral Axis 0.715 in 0.000 in 1.645 in
a=beta*Xneutral 0.608 in 0.000 in 1.398 in
Compression in Concrete 18.597 k 0.000 k 42.786 k
Sum[Steel comp.forces] 0.000 k 0.000 k 0.000 k
Tension in Reinforcing -18.600 k 0.000 k -42.363 k
Find Max As for Ductile Failure...
X-Balanced 5.844 in 0.000 in 1.3686 in
Xmax=Xbal*0.75 4.383 in 0.000 in 1.026 in,•,•
a-max=beta*Xbal 4.968 in 0.000 in 1.163 T •
Compression in Concrete 114.009 k 0.000 k r • 26.698 k•••• •••
Sum
Total[Steel Compressive Forces]
•114.009 k 0.000 k •••••26.698 k••• : 960096
Comp esFoe
AS Max=Tot Force/Fy 1.900 in2 0.000 in2 •••:••0.445 in2 • . •
Actual Tension As 0.310 OK 0.000 OK •*•• 0.000 OW•9 ;"";
Additional Deflection Calcs 0000' •••• 96*
Neutral Axis 1.955 in Mcr • 4.38 k-ft* • •
Igross 512.00 in4 Ms:Max DL+LL " "8.08 k-ft "" '•�';
Icracked 210.51 in4 R1 =(Ms:DL+LL)/Mcr 6-0.642 • •
Elastic Modulus 3,122.0 ksi Ms:Max DL+LL+ST ' C08 k-ft. • ••••:•
Fr=7.5*f'c^.5 410.792 psi R2=(Ms:DL+LL+ST)/Mcr Q 542 000000
Z:Cracking 173.190 ksi keff...Ms(DL+LL) • 2fo8.612 in4 ••••••
Z:cracking>145:Interior Only I Leff...Ms(DL+LL+ST) •258.612 in4 :••• • •
Eff.Flange Width 12.00 in 0000
ACI Factors (per ACI,applied internally to entered loads)
ACI 9-1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 1921.2.7"1.4"Factor 1.400
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7"0.9"Factor 0.900
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300
....seismic=ST*: 1.100
l -
IIIuIIIIpIIII I'
mom
�' ���;'Iflll'I@IIIIIIIIII!IIIIIIIVIiIITs}11��� ��ii�.�IN11111111111111116111111I1i,1t,rW�iriii
'�`��� IlnihJIIIIIIIIIIPIIIIIIIIIIIIIIIIIIIIUIIVIIIIINhn� �� ���iIII�IPIIIIIIiIIIIIIIIIIIIIIIIIIIN��llllllll'117��
���I�IiIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINIIIIIIIJIIIfdlllllll191111111��� ��u�i�u�II��INIIVII�lllal!NIII�IIIIII���YIIIIIJUNh�lll'Illfm'���
��R IIIIIIIIIIIVIIIIIIillllllllllll''IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIUIIIIIIfIIINNIIkIII��� WIWI�f�IIIIIIIININIIIIIIIIiulirl�lllllllllllllllullll111!�
��IR11111111111�IIIIIVIIIIIIIIIII''hlVl!IIIIIIIIIIIIIIVIIIIIIIIIIIIII'IIII'I!IIIIIIIIIIIIIGIIINIIIIIIIIIIIIINIIli1�� �iPWlw�s�R°I�I�IIIIIVIWIIIVIIIIIIIIIJ'IIIIIIPIIIIhn`Illlllllillll'llllll�fllill
■IIIIIIdIIIIIIIIIIIIIIII�IRIIIIIIIIVII'IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII;IIIIIIIIIIIIIIIIIIIIIBIP,INIIIIJIIII!I� &a�IIIwII W�p�I1111111111111nIIIIIIfIIINi9VI�dI1�IlPiulllllllllllillil'llllllll@'ll��
�IINIIIIIIIIIIIIIIIIIIIIIIIIIII16111111111111111GIIIIIIIIIIIIIIIIdIIIIIIIIIIIIPIIIIIIIII!11111111111�1911IIINIIINIIIIIIII!IIIIIII'I'llldll9illl�l�il� ��IIIIIIIJIIhI�li�l�ll'�IIIIIIIIIIOIIIII��IV�ILII�f1MI�INf�I!'WIIIIIIIIIII'llllllllllllllllriif�
3:�If111111111111111111111111111111111111�11119111111111111IfappIIIIIIIIIIIIIIIIIIIIIIIIII�IIIIIIIIIIIIII III IIIIIIIIIIN1111116Vllllllll1111111'i11911111111'll■ �fiIBIIIIII1111N �]�IIII�IIIIIIIIIIIIIIIUN,XIu�'II�III�IIIIIIIVIIIIIIIII�I IIIIIIIIIIIIII�III
IIIIIIINIIIIIIIIIIIIIIIII��IIIIIIIIIIIIIII�IIPIIIIIIIII1'IfllI.IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINI'IIIIIIL II:IIIIIIIIIIIPJIIIIIIIIIillllIIECU
NONNI
IIIIIIIIII 7IIIIIIIIIIIIIIIIN�!�Jl� ryp'!�IIINIIII9191�'�IINIIIIIIIIP"�IIIIIIIIIIIIkINGI IIIIIINIII'dl'Nll!'Ipmq
Nliil��N�II ��� »����■�.I �I
x ;a�■�� rr mG7 & W, a� *r
xTM����u!onoMiL!oiimm ���� x,����►ilnuxluli il�Ii�u�II�R
MOM=ll tilln11111M111M ����fnllunnllll lulu@IVI�INIIIiIIPI II1N11 ��
�p�������,,� err:���muuiiliiiniinir�ii�iiwniiouuuei®muu�iwi���� ���nloluuuu;!Inllluuouuiuui�!II!nI!!s!!I!!!�!!r!�im�
���mui!iiumumouaiaiiieuouauiilL!amf!mLmuowL��� a���rmuuLuuuuuuluniouumullmuul'�!Iuuuum!!u!omonumLmumim�
'S'��6�allll4l'Ilnlllll�l�l�lllllllll�lllllll[IIIIIIInIIIIIIIIIII�III�IIIII�INIIIEIOI�iW��� ��RtlIIIIIIIIIIIVIIIIIIIIIIIIIIIIIPICIIII!IIIIIIIIIIIIIIIIkIIIiIP�IIIIIRfll�lllnllllll�lll6�llllln91�i1��
' I i` ' ' � IIIIEIIIIIIillllll!1119111111111111111NIIIIIInIIfIIIII11m1111111111111111111111111�1AINIYI..IlNilalw� :7���lfillyIl�lllilll'Iilllllllllllllllllllllllll;lllllllllllllllllllllllllllilllmllVJl[11114'III!IIPII�IIIIRIIfdIMll1'111Ism
i ��IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIHIIIIIIIIIIIIIIIIIIIIIIIIIIIVIIflln911lli1IIYIIIIIIIIIIIINII911111WIlIIIOIIIAIIm�� ��fllllllllllllll'IIIIIIIIIVIIIIVIIIIIIIIIIII'ILII'111111!IlllllllllllllllllllnllIIIIIIII,1,ll.Iltllmnlllmmllml91111111mllllkio.
� IVIIIIINIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIilllllll'1'f���
�7f:P#I'�IIIIIIIIIIIIIIIIIIIIl011111111111111111nIIIIIIIIIIIIIIIIIIIIIIIVIIIIIIVIIIYIIII111111111111NII111111VI1111111111A1ElMllllllplo�l� 7Ff7flli�liIIIIIIIIIIIIIIIIIIIII,IIIIIIIIIIIIIVIIIIIIIlhll81411�1'IIIIIIIIIIIIIIIIVIIIIIIIIIIIP�IIH911'IIIIIIIIIIIIIRIIkII'�19�IIINIIa111111
IIIIIIIIIIIIIIIIIIINII'IIIIIIIillllllll'llllllllllllll IIIIIIINII II� ��!!!u!!luumoomLomnmuolm!!IOImu!000!9u9u!u!!IOImuolaloolu!Lm!!m!Lmn!mnneLnoneLeLOLonm!!n!>! �m!!mlmo!o!Iluuumim9l,o�oilul;Ilouuum�uolllu!III�I�u�luiuliouuuiu!il!m!uuiul!I�milmlLOLm!L�muml!��I�mimnLm�.
���f�IIIIINIIIIIIIIIIIIIIIIIIIIIIIIINIIIiII'11111'III'IIIIIIIIIIIIIIIIIIIIIIIINIIIIIIIIIIIIIIdllll'7 � �
V1A1u t
k.uillfF.!4.;7111111iAULlilllllli.I�I&;11111111.S,..IIII .a6.P:.�111,.',&�!fI11CP..]IIIIL71,.711 ��� �&!.IIIIIIILYI IlllllliP...:I'IIIIdIIiilN�llllhll Y,illllllllslC Illllllh al.<llllllll%^h 91WIILkinl�l6Y+DGCdII <��
ISI! '� �Iilllunilllmio!u!ilio!ooiouuu!u�liiloLi!ouuullmlmuuu!mmllil!iII��LILmeL�uLm�nieL�L9LnmL�oLOL�Lm ��oLi!mu!!u!!u!!umu!!!Ioiu�uu�l'loounumuo!uu!ImloLULu!m!uuiouuou!ouiuulul!!soImLouo�om�o.Imo.umomlmmim!m�
�IIIIIIIIIIIIIIIIIIIIIIIIIIIIINIII IIIIIIIIIIIIIIICIIIIIIINIIIIIIillllllllllllllllllllllllll[LIVWIIIII Il#�
�nil�I�!immLo!mummuuuumuouou9uuoolloomlmomiooa!u!!smLtioL+iieim!�nuw�rnimm�iAiii� ,amu!u!!oi!oma!u!I!n�uii�uim�lllu!!Iuuuu!uu!uu!uul.ul:ui!IululuuuuumuluuluulIiluululliil�muiiruluniillul�Ini�I�!u!ur�
fiIIIIIIII1111111111111111111111VIIBlll111111'IINIINIIIIf111141111111111111111111111111111111911NII�IINIII'Itlll �
!IIi1C11111NIIIII1111111111111111111111111111NIIIIIIIIII1NIlEllll'IIIIIINIIIIIIIIIIII�1111111111N IVIILIIk;I;IIW'V"IIIIV'II�
:�?����IOWIu!!!lno!uuI!nIuI!Iu!ImIuIIuuIIunIIuuIIunII9lI6ILIImnI!o!I!IonII!!Iu!ILIuII!IlnImInIIlnImInIImI!nIILlIiIonIoIlImLInIIolILIulIuIoI!ImmmaIILii!IonIILLIo!ImIuIIu!I!InNV!!I��dMuLI!ILAInIunIIe1mLLI1me!!1eMEOu!Inmol���i!Imun �rummomuH!iinmiI!�uPmluiuluuumlmum�nunlu!nlu�i!uI!IMIIlILulnu�I�onmlluLl!llunllullllullnlluilunll9ull!nllul!lo!lIl9IlIlIlunlllul,lLIlI'!uIoIPIdu!!ILLL!!l!!luIlIlmIlIll!iulilllllll!mlolliLlinilillluulllm[nInIInIiL!!LR"
!II�oII�L
linmiNFimoli 9PIImiIIIIVNMI 1111 rEmoVIW!ILIhuOluTo�aonW���
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIINI�IIIINIIIIIIINIIIh11W'INI!I'IINIIII u
:b7�iWllllllllLl mIIIIIIIIIIIIIIIIIIIIIIIIIIIIICIIIIIIIIIIIImlmlllllll�191A1'NIIII�i� .��E�.'���IYYmtlllllln91111111111mlllllllllllilllfll'LIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIi6116111IILIIIIIIIIIIIIIWiW��
q �',I, '',�IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIINIINIIIIIIIIIIIIIIIIIIIIIIIIIIIIINIIIIIIllllllldl(IIIINIIIIIIgGI�I�iNIIVII�I;IIIIIIIIIIIII!� TJsI11IIii IIII°I
1l ' im! Wii ]I'1• L1111m'1II61Nl'11�11111111111111161dIClllllIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIILIIIIJLY���
Ifi�dVIIIIIJllllllllllllllllllllllllllllllllllllllllIIIIIIIIIIIIIIIIIIIIIIIIIIIVIIIIIIIIIIIIIIIIIIVIIIIillllllllClllldl� ��W09u!IIiiioiiioiiiiiiuiuiii�L!!!om �� �� nnLmIlolli°illiilii%HIi11°oi11�Vilhl°uL!III ���
Rev:510300 Concrete Rectangular &Tee Beam Design Page 1 '
Description CONCRETE BEAM
Reinforcing
Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam...
Count Size 'd'from Top Count Size 'd'from Top Count Size 'd'from Top
#1 2 5 9.88 in #1 in #1 in
Uniform Loads
Dead Load Live Load Short Term Start End
#1 0.342 k k k 0.000 ft 4.670 ft
Concentrated Loads ....
Dead Load Live Load Short Term • ` `��` ' " •
6 . oration
#1 k 4.000 k k 0.008; • • •
...... . . ......
summary •.•••• e •
Beam Design O!l ....
0600 *see 6 .
Span=4.67ft,Width=8.00in Depth=8.00in • • • •
•666 •666 • •0•
Maximum Moment:Mu 1.55 k-ft • •
Maximum Deflection ••••-00041 irP •• • •••
Allowable Moment:Mn*phi 25.01 k-ft • •06• ••
• . •660
Maximum Shear:Vu 7.66 k Max Reaction @ Left •••:.:••:64.95 k , 6`
Allowable Shear:Vn*phi 33.66 k Max Reaction @ Right • -0.95 k• • • .• •
Shear Stirrups... •6.6•s
Stirrup Area @ Section 0.220 in2 i ••• 6 i •••:
Region 0.000 0.778 1.557 2.335 3.113 `3.89f 4$761t •
Max.Spacing 4.000 Not Req'd Not Req'd Not Req'd Not Req'd Not Req'd Not ftq'd in
Max Vu 7.661 0.893 0.446 0.436 0.436 0.882 0.850 k
Bending&Shear Force Summary
Bending... Mn*Phi Mu,Eq.9-1 Mu,Eq.9-2 Mu,Eq.9-3
@ Center 25.01 k-ft 1.55 k-ft 1.16 k-ft 1.00 k-ft
@ Left End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
@ Right End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft
Shear... Vn*Phl Vu,Eq.9-1 Vu,Eq.9-2 Vu,Eq.9-3
@ Left End 33.66 k 7.66 k 5.75 k 0.55 k
@ Right End 5.96 k 0.85 k 0.64 k 0.55 k
Deflection
Deflections... Upward Downward
DL+[Bm Wt] 0.0000 in at 4.6700 ft -0.0041 in at 2.3350ft
DL+LL+[em Wt] 0.0000 in at 4.6700 ft -0.0041 in at 2.3350ft
DL+LL+ST+[Bm Wt] 0.0000 in at 4.6700 it -0.0041 in at 2.3350ft
Reactions... (a Left (7a Riaht
DL+[Bm Wt]] 0.949 k 0.949 k
DL+LL+[Bm Wt] 4.949 k 0.949 k
DL+LL+ST+[Bm Wt] 4.949 k 0.949 k
Section Analysis
Evaluate Moment Capacity... Center Left End Rlaht End
X:Neutral Axis 2.145 in 0.000 in 0.000 in
a=beta*Xneutral 1.823 in 0.000 in 0.000 in
Compression in Concrete 37.194 k 0.000 k 0.000 k
Sum[Steel comp.forces] 0.000 k 0.000 k 0.000 k
Tension in Reinforcing -37.200 k 0.000 k 0.000 k
Find Max As for Ductile Failure...
X-Balanced 5.844 in 0.000 in 0.0000 in
Xmax=Xbal*0.75 4.383 in 0.000 in 0.000 in
a-max=beta*Xbal 4.968 in 0.000 in 0.000 in
Compression in Concrete 76.006 k 0.000 k 0.000 k
Sum[Steel Comp Forces] 0.000 k 0.000 k 0.000 k
Total Compressive Force 76.006 k 0.000 k 0.000 k
AS Max=Tot Force/Fy 1.267 in2 0.000 in2 0.000 in2
Actual Tension As 0.620 OK 0.000 OK 0.000 OK
r
� � r
0. 0.342ktft
Mo,Max-1.55k-ft
Dmax-0.00411n
Rev:51 d(1i861kVu Max=0.850k
Concrete Rectangular & Tee Beam Design Page 2
Description CONCRETE BEAM
Additional Deflection Calcs
Neutral Axis 3.120 in Mcr 2.92 k-ft
(gross 341.33 in4 Ms:Max DL+LL 1.11 k-ft
(cracked 343.78 in4 R1 =(Ms:DL+LL)/Mcr 2.636
Elastic Modulus 3,122.0 ksi Ms:Max DL+LL+ST 1.11 k-ft
Fr=7.5"f'c^.5 410.792 psi R2=(Ms:DL+LL+ST)/Mcr 2.636
Z:Cracking 9.655 ksi keff...Ms(DL+LL) 341.333 in4
keff...Ms(DL+LL+ST) 341.333 in4
Eff.Flange Width 8.00 in
ACI Factors (per ACI,applied internally to entered loads) •••
ACI 9-1 &9-2 DL 1.400 ACI 9-2 Group Factor 0.750 UBC 191.2.=%4"Facto?••• 1.4006••••
ACI 9-1 &9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 192h2,71k9"Factor •e• 0.900 e•
ACI 9-1 &9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300 e••e•• e••e ; ,e•e:•
....seismic=ST•: 1.100 •
06
Sketch & Diagram 0008 eeee • i
.47 P.93 .40 1.87 34 80 P.27 74 .20 .67 .47 .j 40 .87 34 80 .27 .74 .2211 .670
•
j 7 • ••e• •• :e
ili II {NII •
116111 1,14 I
13 .40 •
• p ••
.79 s9 •e
• ••• 1 •
1.05 >s
Shear Load k Location Aloe Member ft Shear Load k Location All Member ft
.5%5 D.47 P.93 .40 .27 1.74 1.20 .67 .18 0.47 .93 .40 27 .74 .20 .87
.40 OS
24 I. .93 ir
09 .81
.93 A 111 11 11 .70
.78 68
.62 .47
.47 .36
Be Moment(k-ft) Location Along Member(ft) BeMoment(k-ft) Location Along Member(ft)
Beam Sketch Stresses for ACI 9-1 Combination Stresses for ACI 9-2 Combination
.47 .93 .40 .87 34 80 273.74 .20 .67 1.87 2.34 80 .27 3.74 20 .67 .47 .93 .40 .87 80 .27 .74 .20 .87
I
MLp
.00 II V VII li .00
i 4
P1IIPI"iI. III
'II ILII j s .93 27 7 zo .87h 1 .93 .27 .7 .20 .67
St .89 1 1 .89
se
sneer Load
Location Alon I Member ft
IN 11111 Hill
.00 D.47 0.93 .40 - .27 .74 4.67
.90
.80 11111111111VI 1111
.70 N
All;will]11
.60 111111,11111
.87
.50
.40 'o it
.30
1i
00 .00
li 1'i I
Be MomeM(k-ft) Location Along Member(ft) Looe Y Deflecdon On)� Location AlongMember t) Local Deflection in Location Al... Member ft
( Y ( ) Along ()
Stresses for ACI 9-3 Combination Stresses for Service Dead+Live Loads Stresses for Dead+Llve+Short Term Loads
04/10/2015 10:17AM FAX r1o001i0001
FrankCrum-
A Family of i~niioybr Solutions. N t.1
April 9,2015
VIA FACSIMILE{(305)541.-2023)&U.S.MAIL
PREMIER LABOR SOLUTIONS CORP
Attention: MARIA NOSS
106 SW 27TH AVENUE SUITE A
MIAMI,FL 33135
Re: Acceptance of Applicants As Leased Employees
Dear Valued Client:
We are writing this letter to inform you that we.have received the applications for the following applicants and
reviewed the forms. We have accepted these applicants as our leased employees with the effective date listed below:
Name Employee No, Effective Date
ALEJANDRO ARGUELLES 000000915 04/07/2015
DANIEL LOYOLA 000000916 04/06/2015
SEQUOIA PARKER PEREZ 000000917 04/07/2015
KEVIN ROMER 0000009/8 04/07/2015
Thank you for your attention to this matter. If you have any questions,please feel free to contact us at the telephone
number below.
FrankCrum includes the following companies: FrankCnim 1,Inc.:FrankCrum 2,Inc.;FrankCntm 3,Inc.;FranKfurn 4,Inc.;FrankCntm 5,Inc.;
FrankCmni 6,Inc.;FrankCntm 7,Inc.;FrankCn,m 8,Inc.;FrankCrum 9,Inc.;FrankCn,m 11,Inc.: FrankCn,m 12,Inc.;and FranKn,m of
California,Inc.
FL Lie.GL 100 • Toll Free 800.393.0815 - 100 South Missouri Avenue,Clearwater,FL 33756 - www.frankcrum.com • FL Lie.GL 45
2da/2cr1� : r ReWrtVevver
�r
JEFF ATWAWR
CHIEF FINMCIAL OFFICER STATE OF FLORIDA
DEPARTMENT OF FINANCIAL SERVICES
DIVISION OFWORKERS'COMPENSATION
**CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS'COMPENSATION LAW
CONSTRUCTION INDUSTRY EXEMPTION
This Certifies that the individual listed below has elected to be exempt from Florida Workers'Compensation law.
EFFECTIVE DATE: 2/25/2014 EXPIRATION DATE: 2/2512016
PERSON: RICZO EDWARD S
FEIN: 203142035
BUSINESS NAME AND ADDRESS:
ESR FLORIDA CONSTRUCTION INC
P.O.BOX150472
CAPE CORAL FL 33915
SCOPES OF BUSINESS OR TRADE:
LICENSED GENERAL
CONTRACTOR
P matmnt to Chaµa 440.05(14).F.S..an oierr d corporation caho elm is c wrvton Iran tlas cha{u x by RI. a certikolo ofog6dm anter dors aecgm may
aco+er
not rb&Idts of L WOUtsaJar under tks et�WIW-P r uW to Chapter 440.05(12),F.S.Cabf(Ms d eCbQn to be eampt...applyadY%'th-'Ute scoae
davebsit rtraxustedMd.n0deemGlwaontohe wPAVt wrsuerut°Chap«440sat.Fs_Nobcraorelmd,)ntobe exempt arOcaraswte.,ar
decdm f°beaevo stillw
be sur4mt to reeadal if.at anyofm a ha the filing of ft role aisetwca of the cerlificale,thapos noted on tlm nonce nr
caaebma no Impar meets ih req dra ver tr of das S%gm for issoence d a=tfloate.Tho dgwveta shA revele a certificate m srrj rm to Gtilera o/are
Isantonod m thecerbfiaile to rmat the reguircmm4s of IN secgon.
DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 07-12 OUESTIONSI(a50)413,1609
I
:_.. _,_ _ _.t .._. na s —t,,: ;., an�n� ucrcaa� plKnn7nr�r� tihXlfYfRikrakaF�nP\1v1u4NPt�PN42XeirDRG;IVVtrI>�I... 112
03/11/2015 15:06 (FAX) P.001/001
CERTIFICATELIABILITY INSURANCE F DATEIneMMOMW)
0311112016
T S CERTIFICATE 18 ISSUI3D As A MATTER OF INFORMATION ONLY AND CONFERS RIr3HT8 UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR N1dGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW, THIS CERTIFICATE OF INSURANCE DOLS NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND TWE CERTIFICATE HOLDER.
IMPORTANT: If tho ean)noete holder Is en ADDITIONAL INSURED,the policy oa must be eridGireed.I! UBRO TION IS WA)VtaD,sult)sct to
the terms and oondlflons of the policy,Certain policies may regUlre an endorsement, A statement on this certificate does not confer rights to the
oerutlaste notder in lieu of euah endorsement(s).
PROEstrDUCER
Insurance MARIA L GONZALEZ
1274Ila scaynBlvd � Na (3061w.9707 305)893.3067
Northlam!, 1.Blot{ managerl30 estreliainsurance.aom
NOrth Mtmml,FL 33181
7INSURED
91.6767 g INSURBR RDI GCOVERAGE NaJCa
Pax 305 693-3067 INSURE NATIONAL IN6URAN0E.CpMPANY
CONSTRUCTIONS,INC 3uRERs:
ERC•
IN psiD 33915 E e
COVERAGES IN
CERTIFICATE N_ BER: REVISION NUMBERI
Tlif513 TO CERTIFY THAT THE POLICIES OF INSURANCE L BLOW HAV@ BEEN lBSU D TO TWE INSURED NAMED A9OVE FpR THE pdUCY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CI~RnF10SIONe ATE MAYBE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
E)IOLUAND CONDITIONS OF SUCH POLICIES,LIMITS SHOWN MAY HAVE SEEN U80UCEO BY PAID CLAIMS.
i TYPE OF INSURANCE AO UB
LI NUMBER EFF PMUC
GENERAL LIABILITY LlMrra
❑ COMMERCIAL GENERAL LIABILITY EA "O RRENCE 9,afl. 0.00 .00
RENTE® x_11000,000.00❑ CtA�1s--tdwDE Q occuR ��---�.-1_..
A ❑ Y AMTOo6662 19!27,2014 111x712015 MED `A!4 °n� ®Pt4n a 500,000.00
❑ PERBCHAL6ADVINJURY 3 1000,000,00
4BN'L AGGREGATE LIMrrAPPi-LIzS pgft: GENERAL AGO ELATE 3 2,000,000.00
❑POLICY ® pR O.T i.,J LOC PRODUCT -COMP10p AGO $ 1,000,000.00
AUTOMOBILE LWHILIFY I 3
ANYAUTO
OMa81N D SINOLE LIMIT
•
❑ 'L8`EO r°"q HEgUt80 BODILY INJURY(Perpargon) a -
❑ WIRED AUTOS ❑ AUTG3 NEO BODILY INJURY(Par aeale4nr i
❑ gP R a
UPABRELLA MAS8
❑OCCUR
EXCESS LIAS OtAIM3.MADg &A -OCCURREN E _
❑ RETe"ONI AGOREOATE S
WORKERS COMPENSATION
AND EMPLOYEW LVOLnY YIN 1 ❑ OTH. e
ANY
IDERR CLUDF EC NIA LtLE._
(6tandateryIn NH) ILL.EACH ACCIDeNT
uUOESCdawba er
RIP ON FtlOPERATIONB b*II E.L.0161AS .EA EMP OYtE $
EL.DISEASE-POLICY LIMrr g
1788CRiPT10N OF OPERATION8!LOCATIONttI VEHICLES(AtIAM ACORD 101,Ad".Isa1 Remelt,a Sohedula,If marc apace is required)
GENERAL CONTRACTOR
I
i
i
CERTIFICATE!HOLDER CANCELLATION
SHOI
MIAMI SHORE VILLAGE BUILDINGS DEPT � THE UP.XP ANY
0 TEE THEREOOVE F NOT C11 WILL BE E DELIVERfeD INED BEFORE
10060 NE 2AVE I ACCORDANCE WITH THE POLICY PROVISIONS.
MIAMI SHORE,FL 33138 ; °
AMORzav REPRESENTATIVE
MARIA L GONZALEZ
ACORD 26(2014101)RF { 7 - 14 OR CORPORATION. All rights reserved,
The D name and logo arm registered marks of ACORD
'
03/11/2015 3:36PM FAX
ZOQQ1/OOQ1
CERTIFICATE OF LIABILITY INSURANCE DATE(MMrODrrxvr)
0311112015
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER,
IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy pes)must be endorsed..U SUBROGATION IS WAIVED,subject to the terms and conditions
of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder In lieu of such
endorsement(s).
PRODUCER
CONTACT NAME
PHONE ATC.No,&Q.. 1.800-277.1620 x400 IFAX WC N,): 727)797.0704
FrankCrum Insurance Agency,Inc. E-MAIL ADDRESS:
100 South Missouri Avenue INSURE S)AFFORDING COVERAGE NAICD
Clearwater FL 33756 INSURER A Frank Winston Crum Insurance Co. 11600
INSURED NSURER E
INSURER C
FrankCrum L/C/F Premier Labor Solutions Corp. INSURERO
100 South Missouri Avenue INSURER E'
Clearwater,FL 33756 INSURERF:
COVERAGES CERTIFICATE NU&WER: 312534 REVISION NUMBER: 1
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAME ABOVE FOR THE POLICY PERIOD INDICATED.
NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAYBE ISSUED OR MAY
PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECTTO ALL THE TERMS,EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN
MAY HAVE BEEN REDUCED BY PAID CLAIMS.
1NSR TYPE OF INSURANCE ADOL SUER POLICYEFF POLICY EXP
LTR 1NSRD WND POUCYHUMBER
GENERAL LIABILITY (MIVUODIYYYY) (MmioD/YYYY) LIMITS
EACH OCC URREriCE $
COMMERCIAL GENERAL UABILIT i OAMAGE 70 RENTED
PREMISES Ea oraerente' $
CLANM,SMADEOCCUR MEfl E>:P(Any orre Person) $ ��
PERSONAL r,ADVINJURY $
GENERAL AGGREGATE
GENL AGGREGATE LIMIT APPLIES PER. PRODUCTS COMPJ0P AGS $
POLICY M PROJECT J LOC
tvlTDM08l4E LIABILITY Ca a¢,He D SINGLE LIMIT $
ANY AUTO
ALL OWNED SCHEDULED BODILl INJURY Per ereoe $
AUTOS AUTOS BOG'LYINJUP, (Peraccidem) $
141REO AUTOS OSOYtdVEDAUT PROPERTYDAMAGE $
nI
$
LLMBRELLALtM OCCUR
EXCESSLIAB CLAMS-MADE E 'HO RRENC'
g� :.
S
OST RETENTION$
3
WORKEPSMJPENSATION AND W0201 600000 01/01/2015 O1l0112016TORi OTH-
A EMPLOYERS'UABILITr Y/N S ER
ANY PPOPRIETORIPARTNEP,E:fECUJTI'rE Q
OFFICEP,'MEMBER E<rLUDE07 N/A
(Mandatory In NH) OENT
!r yes.dobe ender
DESCRIPTION OF OPERATIONS below AEMPLOYEE gl DUDOD
OUCYLMT SIODOM
DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES(AttachACOR D 101,Additional Remarks;Schedule,if more space Is requtred)
Effective 03/15/2010,coverage is for 100%of the employees of FrankCrum leased to.Premier Labor Solutions Corp.(Client)for whom the client is reporting
hours to FrankCrum while on assignment with ESR Florida Construction,Inc..Coverage Is not extended to statutory employees.
CERTIFICATE HOLDER CANC LATiON
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE
E`PJRATION DATE THEREOF,NOTICEVAL-L BE DELIVERED IN ACCORDANCE WITH THE
POLICY PROVISIONS
Miami Shares Village
Building Department AUTHORIZEDREf SENTATIVE
10050 NE 2nd Avenue „.
Miami Shores,FL 33138
O 1988-2010 ACORD CORPORATION,All rights reserved.
ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD
FrankCrum 3/11/2015 15:32 Pag92/2
r
DATE IMMIMUYVYY)
. & CERTIFICATE OF LIABILITY INSURANCE 03/1112015
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER,THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED
REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER.
fNPOR the certificate holder ks an ADD1111ONAL INSURED.the pact'(les)must be endorsed.tt SUBRO6ATION IS VdANED,subject to the terms end conditions
at the policy,certain policies may mqulre an endorsement A statement on this oerthicate does not confer rlphts to the cardflcate holder in Be"of such
andorsement(s)
PRODUCER GONTACTNAME:
PHONE AEC No E1d: 149130.277.1620 x4000 FAX AIC,Na 72 797.0704
FrankCrum Insurance Agency,Inc. E-MAIL ADDRESS:
100 South Missouri Avenue IN5UIRIERI[fil AFFORDING COVERAGE NAEC#
Clearwater FL 33756 INSURER A: Frank Wnstgn Crum Inswance Co. 11600
INSURED INSURERS-
INSURER
NSURERB:INSURER C:
FrankCrum UC1F Premier Labor Solutions Corp. INSURER D:
100 South Missouri Avenue INSURER E:
Clearwater,FL 33756INSURER F:
COVERAGES
CERTIFICATE NUMBE 31.2534 REVISION NUMBER: 1
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAME ABOVE FOR THE POLICY PERIOD INDICATED.
NOIWTHSTANDINO ANY REQUIREMENT,TERM OR CONDMON OF ANY CONTRACT OR OTHER DOCUMENT HATH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY
PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,EXCLUSIONS AN D CONDITIONS OF SUCH POLICIES.LOWS SHOWN
MAY HAVE BEEN REDUCE=D BY PAID CLAIM& _..
fNSR ADDL. 6URR POLICY E" POLIGYM
LTR TYRE OF INSURANCEINIM WV13 POLICY NUMBER YlDD { LUAU
GENERAL LIABILITY EACH OCCURRENCE $
MMERGIAL GENERAL LIABILITY > e•:+ . S
tx.AlMs-MAGE OCCUR MED EXP(Any Pm Parson! S
PERSONAL d AOV IN.AJRY S
GENERAL AGGREGATE S
GENLAGGREGATE UMIT APPUESPER PROGUCTS.GOIAPIOP AGG S
r*ouc r771 PROJECT=toc S
AUTOMOBILE LTA6ILITY cokL61 SDWNGLBUWrT S
aM -
ANY AUTO
SOOILYNAJRY
ALL OWNED SCHEMLE13
AUTO$ AUTOS BODILYINJURY Pwswdcnll S
HKED AUTOS NON-OWNED PROPERTY DAMAGE $
AUTOS pm nddm
$
UNBRELLAUA9 O0WR EACH OCURFENCE 8
t14R CLAIMS-NAM AOBREGATE S
OED I I RETaMON S S
WORUFRS COMPEN5A11ON AND WC20I GCOODO 01/0112015 01/0112016x YfG STATUTORY 3TH-
A EUPLOYERS LIABILITY YIN uMlrs ER
ANY PROPRIETORWARTNERIEXECUTWE
OMCERlh1EN8EREXCLUVEa7 NEA Et EACH ACMDENT 1090
(NmWatay in NMI
n yft,0-4.Wider E.L.DISEASE-EA EMPLOYEE f aw ow
OEsmipnoN OF OPERATIONS below
E.L DISEASE-POLICY LIMIT 51900090
DESCRIPTION OF OPERATIONS I LOCATIONS i VEHICLES ah ACORD 101,Additional Reame",Schedule,If more specs is required)
Effective 0311512010,coverage Is for 100° of the emldoyees of FrankCrum leased to Premier Labor Solutlons Corp.(Clent)for whom the rllent Is report)ng
hours to FrankCtum while on assignment with ESR Florida Construction,Inc..Coverage IS not extended to statutory employees.
CERTIFICATE HOLDER CANCELLATION
SHOULD ANY OF THE ABOVE-DESCRIBED POLICIES BE CANCELLED BEFORE THE
EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ACCORDANCE wETH THE
POLICY PROVISIONS.
Miami Shores Village
Building Department AUTHORixn REPILESENTAINE
10050 NE 2nd Avenue d �s�
Miami Shores,FL 33138
O 1988-201a ACORD CORPORATION,AN rights re9Crvcd.
ACORD 25(2010105) The ACORD name and logo are registered marks of ACORD
rS Ir
a�