Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL +
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-281980 Permit Number: RC-12-15-3127
Inspection Date: May 11, 2017 Permit Type: Residential Construction
Inspector: Dacquisto, David Inspection Type: Survey Final
Owner: KURLANDSKI, GUY&SELIN Work Classification: Addition/Alteration
Job Address:9301 N BAYSHORE Drive
Miami Shores, FL Phone Number
Parcel Number 1132050270560
Project: <NONE>
Contractor: CONSTRUSERVE CORP Phone: (786)380-0619
Building Department Comments
GARAGE CONVERSION TO FAMILY ROOM, INTERIOR Infractio Passed Comments
REMODELING, CONVERSION DEN INTO BEDROOM, INSPECTOR COMMENTS False
AND 2ND STORY ADDITION.
Inspector Comments
Passed /( CREATED AS REINSPECTION FOR INSP-281966. SHOW DISTANCE ON
SURVEY FROM POOL DECK TO SIDE PLOT LINE AND TO INSIDE OF
SEAWALL
Failed �1 ( (� �-� AND
S� SHOW DISTANCE ON SURVEY FROM INSIDE OF POOL (WATER'S
EDGE)TO SIDE PLOT LINE AND TO INSIDE OF SEAWALL
Correction ❑
Needed REQUIRED SETBACKS CD /-7
FOR SWIMMING POOLS:
SIDE YARD SETBACK: FROM THE INSIDE FACE OF POOL WALL TO
THE SIDE PLOT LINE THERE SHALL BE A 121/2-FT. MINIMUM SETBACK;
FROM THE POOL DECK OR SCREEN ENCLOSURE TO THE SIDE LOT
Re-Inspection ❑ LINE THERE SHALL BE A 10-FT. MINIMUM SETBACK.
Fee REAR YARD SETBACK: FOR SWIMMING POOLS: FROM THE INSIDE
FACE OF POOL WALL TO THE LOT LINE THERE SHALL BE A 71/2-FT.
MINIMUM SETBACK; FROM THE POOL DECK OR SCREEN
No Additional Inspections can be scheduled until ENCLOSURE TO THE LOT LINE THERE SHALL BE A 5-FT. MINIMUM
re-inspection fee is paid. SETBACK.
POOL EQUIPMENT
SIDE YARD SETBACK: 10-FT. MINIMUM SETBACK
REAR YARD SETBACK: 5-FT. MINIMUM SETBACK
For Inspections please call: (305)762-4949
May 11, 2017 Page 1 of 1
i
PERMIT #:
Miami Shcres Villa e LOT - 2 I
BLOCK - 4 e 0 IG °20
APPROVED BY DATE _j I FOUND Y" _ FOUND I
O FLIRON PIPE NAIL 8 DISC SCALE: I" = 20'
ZONING DEPT 3
3 N89�22'52"W 169.
1.00'
BLDG DEPT x Pool
_ PUMP (� x ..
T s.9 bti ` 6 �n ° RECEIVED
SUBJECT i0CCh1PLU"NCEWITHALLFEDERAL W O � i/,C;. 4S' o
STATE ANL)CCI�N I f r1L,L,=S ARID R/EGULATIONS ' 73.3' ( � Ij fI !� II II f1 �1 I 48.16' O
"i. , u :; " 1 Ir I tIt ,, o MAY 112017
Q .• CONCRETE�r ! I� { ITRELIis: I� (n
If FOUND
/
1,0)
. " SLAG. y GARAGE1 i { 1I ; �� (� 1 �' ' RILL FH { N 6.5' I � WATER'S EDGEW DRIVEWAY F.F. ELEV.= 5.96' I � (24 87sees_ 1.5' 19.3' •• • e ese •
' N s • • sees••
OD
~ a co .x ONE AND TWO STORY c v 16.20 %i _ Q••••• e s
�j r mssss s s ssssss
Q '� a - - 1 RESIDENCE ss•s
W O •ecce
N.E. 93RD REST m ° 21.9' ;. BUILDING N0. 9301 W •
rn s CONCRETE �7.. //'yj/ zsees. esssss ss:sse
- O SLA6 F.F. ELEV.= 7.72' ^ CE _ ;y ^ )roe**
50' TOTAL R/W t,. ^. <: o. ' ' s•s s s•
> x o J s POOL y 12.00' o �e s s s so
Y b ,\ /' / / • •ecce• ••eee•
o3
i D
Z LOT - 3 Y m s
- O L9 ►Q / ss sees
,o O BLOCK -4 17.60' ••
Z
45.7' X
17.8' Y --� O
s, 11.40' O
k
\ G 08, xMCD
6/ 1.40'
P U c6 (V %
co
\ ------- f
FOUND NB '15.23•W 64�. � o
.85' P. FOUND Y2" ('
FOUND 10
AIL N8 '22'46'W ON PIPE "p �p = o " o Z co n z
\ 5.00' P. o N89 22 46 W 167.67 DRILL HOLE
- o I w
I LL_
LOT LOT - 4 >
BLOCK -4 I ? CD a
LEGAL DESCRIPTION: NOT BE BEING USED BY ADJOINERS. ADJOINING PARCELS HAVE NOT BEEN INVESTIGATED.
� o O
LOT 3, BLOCK 4, BAY LURE ACCORDING TO THE MAP THEREOF, AS RECORDED IN PLAT BOOK 44, PAGE 63 OF 9. THIS SURVEY MAP IS INTENDED TO BE DISPLAYED AT THE SCALE SHOWN HEREON. DATA IS EXPRESSED IN U.S. SURVEY FOOT. LU
THE
THE PUBLIC RECORDS OF MIAMI-DADE COUNTY, FLORIDA.
10.THIS SURVEY MAP IS BEING PREPARED FOR THE USE OF THE PARTY/PARTIES THAT IT IS CERTIFIED TO AND DOES NOT EXTEND N m
TO ANY UNNAMED INDIVIDUAL, ENTITY OR ASSIGNEE. I HEREBY CERTIFY T0: N 3
SURVEYOR'S REPORT AND GENERAL NOTES II. FLOOD PLAIN INFORMATION: As SCALED FROM FEDERAL INSURANCE RATE MAP (FIRM) of COMMUNITY No. 120652 GUY KURLANDSKIY T KURLANDSKI Q UJ 3
(NOT VALID WITHOUT THE ATTACHED SURVEY MAP) (VILLAGE OF MIAMI SHORES), PANEL 0451, SUFFIX L, REVISED ON SEPT IITH, 2009, THIS REAL PROPERTY FALLS IN ZONE "AE" J H- is -
WITH BASE FLOOD ELEVATION 10 FEET AND'VE"WITH BASE FLOOD ELEVATION II FEET 5LL
F
I. LEGAL DESCRIPTION HAS BEEN FURNISHED BY THE CLIENT. 12.HORIZONTAL ACCURACY: ACCURACY OBTAINED THRU MEASUREMENTS AND CALCULATIONS MEETS AND EXCEEDS THE MINIMUM O V) O
2. REFERENCES TO "DEED", "RECORD" OR "PLAT"REFER TO DOCUMENTS AND INSTRUMENTS OF RECORD AS PART OF THE HORIZONTAL FEATURE ACCURACY FOR AN URBAN AREA BEING EQUAL TO I FOOT IN 7, 500 FEET. THAT THIS SURVEY CONFORMS TO THE STANDARDS OF PRACTICE AS SET FORTH • • p
PERTINENT INFORMATION USED FOR THIS SURVEY WORK. MEASURED DISTANCES, DIRECTIONS AND ANGLES ALONG BOUNDARY 13.VERTICAL CONTROL AND ACCURACY: THE ELEVATIONS AS SHOWN ARE REFERRED TO THE NATIONAL GEODETIC VERTICAL BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS IN Z
LINES ARE IN CONSISTENCY WITH CORRESPONDING VALUES FROM RECORDS, UNLESS OTHERWISE SHOWN. DATUM OF 1929 (NGVD 1929). THE CLOSURE IN FEET, AS COMPUTED, MEETS THE STANDARD OF PLUS OR MINUS 0.05 FEET APPLICABLE PROVISIONS OF CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE W ::) 10 J
3. THESE LANDS ARE SUBJECT TO ADDITIONAL RESTRICTIONS OF RECORD THAT WERE NOT FURNISHED TO THE UNDERSIGNING TIMES THE SQUARED ROOT OF THE LOOP DISTANCE IN MILES. ELEVATION ARE BASED ON A LEVEL LOOP FROM AND TO THE PURSUANT TO SECTION 472.027 FLORIDA STATUTES. THIS SURVEY IS ACCURATE m W '0 OJ
AND CORRECT TO THE BEST OF MY KNOWLEDGE AND BELIEF. CT
REGISTERED SURVEYOR. A TITLE SEARCH HAS NOT BEEN PERFORMED. FOLLOWING OFFICIAL BENCH MARKS: ^ > UJ
4. NORTH ARROW DIRECTION IS BASED ON AN ASSUMED MERIDIAN. BENCH MARK# is MIAMI-DADE COUNTY PUBLIC WORKS DEPARTMENT BENCH MARK B-62, ELEVATION =8.65 FEET Q M
5. BEARINGS ARE BASED ON AN ASSUMED MERIDIAN ON A WELL-ESTABLISHED LINE,SAID LINE IS BEING NOTED AS BR ON THE LOCATION: NE 96 ST --- 66' NORTH OF C/L, NE 10 AVE --- 23.5' WEST OF C/L, 70.7' NW OF CENTER OF �•-•� M N O
SURVEY MAP. INTERSECTIONO - u0 U_
ODALYS C. BELLO-IZNAGA O Z
6. ONLY ABOVE GROUND IMPROVEMENTS ARE SHOWN HEREIN. FOUNDATIONS, UNDERGROUND FEATURES AND UTILITIES HAVE NOT DESCRIPTION: BRASS BAR IN CONC MON. PROFESSIONAL SURVEYOR AND MAPPER LS6169.STATE OF FLORIDA J (n M
BEEN LOCATED. BENCH MARK# 2: MIAMI-DADE COUNTY PUBLIC WORKS DEPARTMENT BENCH MARK N-800, ELEVATION = 9.33 FEET FIELD WORK DATE: 04/19/2017 COMPLETION DATE: 04/21/2017 J O tL J
7. FENCE OWNERSHIP HAS NOT BEEN DETERMINED. DISTANCES FROM EXISTING FENCES TO BOUNDARY LINES ARE APPROXIMATE. LOCATION: NE 96 ST --- 34' NORTH OF C/L, US HWY #1 (BISC BLVD)--- 134' WEST OF C/L REVISED: 05/09/2017H7 Z Q
FENCE/WALLS WIDTH AND CONDITIONS MUST BE CONSIDERED TO DETERMINE TRUE LOCATION. 1.1.1 N 2 f
8. TRUE BOUNDARY CORNERS MIGHT BE OBSTRUCTED BY EXISTING FENCES AND/OR VEGETATION. OFFSET MONUMENTS ARE BEING DESCRIPTION: PK NAIL AND BRASS WASHER IN CONC CATCH BASIN. FADDN DELETIONS TO THIS SURVEY MAP ARE PROHIBITED. THIS SURVEY MAP AND m _ aT 1
SET AS NOTED,UNLESS THEY CAN'T BE SET ON BOUNDARY LINES. LANDS LOCATED BEYOND PERIMETER FENCES MIGHT OR MIGHT OT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OR WITHOUT
ATED ELECTRONIC SIGNATURE AND SEAL OF THE UNDERSIGNING FLORIDA
EYOR AND MAPPER.
LEGEND 8 ABBREVIATIONS MAP 0 F BOUNDARY SURVEY
< 'ti
t• -CONCRETE(GONG.) =WATER VALVE(WV) O$ =SANITARY MANHOLE ® =CATCH BASIN OR INLET PT =POINT OF TANGENCY CALC =CALCULATED CBS =CONCRETE BLOC)(STRUCTURE
D �
�T• =- PC =POINT OF CURVATURE MEAS =FIELD MEASURED R/W =RIGHT OF WAY
=CONC.BLOCK WALL cQ�=GOWER COLE(PP) O =DRAINAGE MANHOLE ,X* 'EXISTING ELEVATION
_WOE DECK GUY
=POINT OF REVS SE
CURVE p =PER FLAT ELEV =ELEVATION PROPERTY ADDRESS: "
GUV ANCHOR
COVERED AREA =MANHOLE =PERMANENT REFERENCE PRC =POINT OF REVERSE CURVE GSM =PROFESSIONAL SURVEYOR AND SEC =SECTION
0=ASPHALT ® =WATER METER(WM) O MONUMENT(PRM) BI" BENCHMARK MAPPER TWS =TOWNSHIP
CHAIN LINK FENCE(CLF) =FIRE HYDRANT BR -BEARING REFERENCE BENCH A/C =AIR CONDITIONER PAD RG =RANGE !.
=WOOD FENCE(WF) ¢ =GONG.LIGHT POLE(LP) � • =PROPERTY CORNER TBM =TEMPORARY BENCH MARK 9301 N. BAYSHORE DRIVE, MIAMI SHORES, FLORIDA 33138
-fH/- CABLE BOX(CATV) ENCR =ENNISHED FLOOR R =RADIUS
=
=METAL BARS FENCE(IF) WELL . R =PROPERTY UNE FF ELEV=FINISHED FLOOR ELEVATION
=OVERHEAD WIRES T=STREET SIGN TX =FPL TRANSFORMER =PERMANENT CONTROL Q ,CENTER UNE PB =PLAT 8001( PROJECT N0. 17192
-OFIL- � POINT(PCP) r MONUMENT LINE = PAGE I OF
0
A R C H I T E C T U R E
December 12, 2016
City of Miami Shores
Master Permit No. RC-12-15-3127
Re: Driveway Permit Narrative for:
Kurlandski Residence Renovation and Addition for
9301 N. Bayshore Drive, Miami Shores, FL.
To whom it may concern,
The following Construction Document Sheets are being submitted for a driveway permit:
Architectural
SP-1.1 Shows location and configuration of proposed driveway
STRUCTURAL
S-4.1 Shows Driveway Section and Plan Detail
S-4.2 Shows Driveway Section
• V
Should you have any questions, do not hesitate to contact this office. ,.•••• '• ••
Sincerely, ••.t •.....
•
....Y/1
:900 • •
Mike Stroh •'
04 0600
•••••e •
Project Manager •
•.....
•• . .t.. :9008,
•
••
USA CAYMAN ISLANDS
17100 Collins Ave. Ste. 220 6104 Forum Lane
Sunny Isles Beach, FI 33160 Camana Bay,Grand Cayman
1.305.940.0555 1.345.525.0777
Arlenis Silvera
From: Arlenis Silvera
Sent: Monday, May 15, 2017 10:59 AM
To: 'Ana Lucia Sierra';Inspections; Sindia Alvarez
Subject: RE: Recorded Covenant - Declaration of Use - 9301 N Bayshore Dr
Good Morning Ms. Sierra,
The document was not attached to the e-mail.
However, all documents you wish to submit, must be walked-in to our office.
Once you have all the necessary documents you can submit them together for review.
Best Regards,
Arlenis Silvera
Permit Clerk Supervisor
tat It 17
OR ,
ANNI
Miami Shores Village
10050 NE 2 AVE
Miami Shores, FI 33138
305-795-2204
www.miamishoresvillaee.com
From:Ana Lucia Sierra [mailto:analucia@eastofcollins.com]
Sent: Monday, May 08, 2017 4:06 PM
To: Inspections<I@msvfl.gov>; Sindia Alvarez<Alvarers@msvfl.gov>;Arlenis Silvera <SilveraA@msvfl.gov>
Subject: Re: Recorded Covenant- Declaration of Use-9301 N Bayshore Dr
Good afternoon all,
Attached please find the recorded Declaration of Use Covenant for 9301 N Bayshore Dr.
This is one of the 3 documents you mentioned last week we were missing in order to obtain the CO but it seems
like today we received some sort of comment I believe on the survey.
Could you forward that comment please.
i
Thank you and have a great day
Ana Lucia Sierra
Office Manager
East of Collins Expediting
17100 Collins Ave, Suite 215
Sunny Isles, FL 33160
C 786-458-1961
O 305-974-0209
F 305-489-0888
E analucia(c)eastofcollins.com
Please consider your environmental responsibility. Before printing this e-mail message, ask yourself whether
you really need a hard copy.
z
9301 N Bayshore Drive - Miami Shores - Florida - 33138
Ismael Naranjo
Miami Shores Village
Building Department
16th February 2017
Ref: Permit No.:RC-12-15-3127
Address: 9301 N Bayshore dr., Miami Shores FL 33138
Dear Mr Naranjo,
We are requesting that we are granted a Temporary Certificate of Occupancy (TCO) for the
residential single family home located at the address noted above.
The reason for our request is that we can no longer remain at the temporary location and need
to return as a family Myself, Wife - Selin and two young daughters Talia and Siena, 6 & 10.
Of course it is understood and agreed that if we are granted a TCO we agree to all the terms of
the City of Miami Shores in relation to being granted that TCO.
We hereby hold harmless and release Miami Shores Village Building Department and Miami-
Dade Fire Department from any liability that may arise during the use of designated areas in the
aforementioned facility while under the limitation of the Temporary Certificate of Occupancy.
We hereby certify that all means of egress shall be kept clear and accessible and that all life
safety systems will be maintained and operable at all times while the building is being occupied.
Many thanks for your kind consideration
1
G urlandski
Owner
CONSTRUSERVE CORP
Ismael Naranjo
Miami Shores Village
Building Department
2-16-2017
Ref: Permit No.:RC-12-15-3127
Address: 9301 N Bayshore dr., Miami Shores FL 33138
Dear Mr Ismael Naranjo,
I am writing to request that we are granted a Temporary Certificate of Occupancy (TCO) for the
residential single family home located at the address noted above.
The reason for our request is that the owner can no longer remain at the temporary location
they are staying at and need to return as a family to their family home. We are therefore asking
that a TCO be issued for a term of 90 days.
We hereby hold harmless and release Miami Shores Village Building Department and Miami-
Dade Fire Department from any liability that may arise during the use of designated areas in the
aforementioned facility while under the limitation of the Temporary Certificate of Occupancy.
We hereby certify that all means of egress shall be kept clear and accessible and that all life
safety systems will be maintained and operable at all times while the building is being occupied.
Thank you in advance for your co-operation
Sincerely
F eir
Ce (7 6)7 -6
11687 SW 144 Ave, Miami FL 33186
I . #'• �, y ' • - �� t tij. r•� .P � x R �i .�3, .�. - I�� •161` 1I
D H. ,.� >.aa:: •'L'S1a.+ ,t-+.+' :i::n..�:..i - . .. .J..i :�. :. -. 1t�:1"1•.eiw-n..V:. .1w T1'•.1' .. -.( '. . j...'.'.e1r-'ia.,i C. ."l: ... .fx.:7Yt.. •f
Certificate of CompletioX!
n
= Miami Shores Village r 5
� y
10050 NE 2 Ave Miami Shores FL 33138
Tel: 305-795-2204 Fax: 305-756-8972 t <r
Building Inspection Department
r' `t This certificate issued pursuant to the requirements of the Florida Building Code 106.1.2 certifying that at the time of issuance this structure was in
compliance with the various ordinances of the jurisdiction regulating building construction or use. For the following: „
a s Permit Type RESIDENTIAL CONSTRUCTION Bldg. Permit No. RC-12-15-3127
z Owner GUY&SELIN KURLANDSKI Contractor CONSTRUSERVE CORP a lI
Subdivision/Project NONE Date Issued May 19, 2017
Occupancy
Construction Type V-B Load N/A _
,' Occupancy
Square Footage 4600 Type R-3 }•
Description of INTERIOR RENOVATION AND ADDITION Applicable
x• - Work Code 2014 FLORIDA BUILDING t;
Location
9301 N BAYSHORE DRIVEk'
j � Miami Shores FL 33138 f 1,
Goal Pi uut Building Officials Approval Ismael Naranjo,179Ui
17 ..awe Not Transferable
NOIRIDP POST IN A CONSPICUOUS PLACE
:.
�r 4 �; nikrw -. -a+.. .,. titNr ..'..�' }.µ ^, .-•n^Ts 7` MLS. i-r -iflr .- _,],,. r��.. .� _:T..�, r...� .a.+.- r * ... ._r ,, t,, :,r. •-x•..-�, �`-r
j ,"`"'SHS, 'r r1� � -'�� �„ i �` 1f�'�.'a.• ' ''� �" = - -� ryr __[[ � �'r^ , � '�, a�rp' � +i 1
P Ji �� a S r � �r' ' �, � ,• r,. SaL t. 1 0 1.. �,•: �� ,n '.tr
INSPECTION RECORD -- POST ON SITE
a Permit NO RC-12-15-3127
Miami Shores Village
c Permit Type:Residential Cpnstruction
7� 10050 N.E.2nd Avenue
Miami Shores,FL 33138-0000 teratio' n
Phone: (305)795-2204 Fax: (305)756-8972
Fro for Irsue Date: 5/5/2016 11/0'U2016
Expires:
INSPECTION REQUESTS: (305)762-4949 or Log on at haps://bldg.miamishoresvillage.comlcap
REQUESTS ARE ACCEPTED DURING 8:30AM-3:30PM FOR THE FOLLOWING BUSINESS DAY.
Requests must be received by 3 pm for following day inspections.
Residential Construction Parcel #:1132050270560
Owner's Name:GUY & SELIN KURLANDSKI Owner's Phone:
Job Address: 9301 N BAYSHORE Drive Total Square Feet: 4600
Miami Shores, FL
` Bond Number: 3075 Total Job Valuation: $ 202,372.00
WORK IS ALLOWED:
MONDAY THROUGH FRIDAY,8:OOAM-7:OOPM.
Contractor(s) Phone L36 ary Coritrac SATURDAY 8:OOAM-6:OOPM.
CONSTRUSERVE CORP (786)380-0619 Y.ej NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS.
BUILDING AND ROOFING INSPECTIONS ARE DONE
MONDAY THROUGH FRIDAY.
a
VA I&S L44 tA4
car txATW
v
NO INSPECTION WILL BE M)WE UNLESS THE PERMIT CARD IS-DISPLAYED AND HAS BEEN APPROVED. PLANS ARE READLY AVAILABLE. IT IS
THE PERMIT APPLICANT'S RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER
THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL
REQUIRED TO ALLOW INSPECTION.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR. PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO -OBTAIN FINANCING, CONSULT WITH. YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCEMENT.
l �ti7 I r
INSPECTION RECORD
STRUCTURALf PLUMBING
INSPECTION DATE INSP INSPECTION DATE INSP INSPECTION DATE INSP
Foundation Zoning Final
Stemwall ZONING COMMENTS Rough
Slab Water Service
Columns 1st Lift 2nd Rough
Columns 2nd Litt To Out —'L--/
Tie Beam Fire Sprinklers
Truss/Rafters J Septic Tank
Roof Sheathin Sewer Hook-up
Bucks Roof Drains
Windows/Doors Gas
Interior Framing INSPECTION DATE INSP. LP Tank
Insulation Temporary.Pole Well
Ceiling Grid, 30 Day Temporary Lawn Sprinklers
Drywall -LW 110 Pool Bonding Main Drain
Firewall Pool Deck Bonding Pool Piping
Wire Lath T., , Pool Wet Niche Backflow Preventor
Pool Steel Underground Interceptor
Poo: Deck Footer Groun U / Catch Basins
Final Pool Slab Condensate Drains
Final Fence Wall Rough HRS Final
Screen Enclosure Ceiling Rou — '�
KW
Driveway Rough PLUMSIN COMMENT
DrivewaV Base j / Tele hone o h r'
Tin Ca � Tele hone Final
Roo' in Progress 1, TV Rough
Mop in Progress I TV Final oil —
Final Roof Cable Rough
Shutters Attachment Cable Final
M Final Shutters Intercom Rough
MECHANICAL
M Rails and Guardrails Intercom Final
ADA cam liance Alarm Rough INSPECTION IDATE INSP
z4zzll T Alarm Final Underground Pipe
DOCUMENTS Fire Alarm Rough
Soil Bearing Cert Fire Alarm Final Rou h
Soil Treatment Cert IService Work With
Floor Elevation Survey Ventilation Rough
Reinf Unit Mas Cert ELECTRICAL COMMENTS Hood Rough
Insulation Certificate 04, Pressure Test
Spot Survey .7/Vv i/ Final Hood
Final Survey Final Vontilation
Truss Certification I Final Pool Heater
STRUCTURAL COMMENTS Final Vacuum
L�' • MECHANICAL CO MENTS
INDATE INSP
Final S rinkler
Final Alarm
INSPECTION RECORD POST ON SITE
Permit NO. RC-12-15-3127
]Miami Shores Village
ttqq t
��e�,R�sl e� i�l , nstrtctton
10050 N.E.2nd Avenue � f t s.{ n ^v ' '" e
T.S � z a � y k�.y, a� �Y �' �ke�%1'",p'J
-+ - Miami Shores.FL 33138-0000 ; =: (�/ stc � If)OntAitBfB 'on!
�e ti-^;Yd 4.+4•c Pir.Y' fAYMt>r'1F'\J MAO,*-
`�,e a� Phone: (305)795-2204 Fax: (305)756-8972
FtoRi"or Issue Date: 5/5/2016 Expires: 11/01/2016
r
,;.FIN+'.T' r•�'+
INSPECTION REQUESTS: (305)762-4949 or Log on at https:llbidg.miamishoresvillage.cam/cap
REQUESTS ARE ACCEPTED DURING 8:30AM-3:30PM FOR THE FOLLOWING BUSINESS DAY.
Requests must be received by 3 pm for following day inspections.
Residential Construction Parcel #:1132050270560
Owner's Name:GUY & SELIN KURLANDSKI Owner's Phone:
Job Address: 9301 N BAYSHORE Drive Total Square Feet: 4600
Miami Shores FL Total Job Valuation: $ 202,372.00
Bond Number: 3075
WORK IS ALLOWED:
.. MONDAY THROUGH FRIDAY,8:OOAM-7:OOPM.
Contractor(s) _ Phone Pri ary d0kCtracfl SATURDAY 8:OOAM-6:OOPM.
CONSTRUSERVE CORP (786)38G-0619 Yep j NO WORK IS ALLOWED ON SUNDAY OR HOLIDAYS.
'' F BUILDING AND ROOFING INSPECTIONS ARE DONE
MONDAY THROUGH FRIDAY.
SR siRe�r rcT
-JA I LAA
1/57
S C .
NO INSPECTION WILL BE MADE UNLESS THE PERMIT CARD IS DISPLAYED AND HAS BEEN APPROVED. PLANS ARE READLY AVAILABLE. IT IS
THE PERMIT APPLICANTS RESPONSIBILITY TO ENSURE THAT WORK IS ACCESSIBLE AND EXPOSED FOR INSPECTION PURPOSES. NEITHER
THE BUILDING OFFICIAL NOR THE CITY SHALL BE LIABLE FOR EXPENSE ENTAILED IN THE REMOVAL OR REPLACEMENT OF ANY MATERIAL
REQUIRED TO ALLOW INSPECTION.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED
AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU
INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF
COMMENCEMENT.
D7/1
INSPECTION RECORD
STRUCTURAL ZONINGPLUMBING
INSPECTION DATE INSP INSPECTION I DATEI P INSPECTION DATE I INSP
Foundation Zoning Final
Stemwall ZONING COMMENTS Rough
Slab - Water Service
Columns 1 st-Lift 2nd Rough
Columns 2nd LiftTop Out
Tie Beam Fire Sprinklers
Truss/Rafters Septic Tank
Roof Sheathing Sewer Hook-up
Bucks Roof Drains
Windows/Doors � Gas
~
Interior Framing INSPECTION DATE I INSP LP Tank
Insulation TemporaryPole Well
Ceiling Grid 30 Day Temporary Lawn Sprinklers
Drywall t V& Pool Bonding Main Drain
Firewall Pool Deck Bonding Pool Pi in
Wire Lath Pool Wet Niche Backflow Preventor
Pool Steel Underground Interceptor
Pool Deck Footer Groun U / Catch Basins
Final Pool Slab Condensate Drains
Final Fence Wall Rough HRS Final
Screen Enclosure Ceiling Roqgh,,
Driveway Rough PLUMBIN COMMENT
Driveway Base j Telephone Ao6gh O
Tin CaU r ' Telephone Final
Roof in Progress A TV,Rough - CARE
a'
Mop in Progress I TV Final o -
Final Roof Cable Rough
Shutters Attachment Cable Final
i Final Shutters Intercom Rough
Rails and Guardrails Intercom Final MECHANICAL
ADA com liance Alarm Rough INSPECTION DATE INSP
Alarm Final Underground Pipe
DOCUMENTS Fire Alarm Rough
Soil Bearing Cert Fire Alarm Final00"- Rou h
Soil Treatment Cert Service Work With
Floor Elevation Survey Ventilation Rough 40
Reinf Unit Mas Cert ELECTRICAL COMMENTS Hood Rough
Insulation Certificate b�v �� Pressure Test
Spot SurveyNut/ Final Hood
Final SurveyFinal Ventilation
Truss Certification Final Pool Heater
STRUCTURAL COMMENTS Final Vacuum
MECHANICAL O MENTS
INSPECTION DATE INSP
Final S rinkler
Final Alarm