Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-16-868
n �� E71XtTIi` F7,X . Miami Shores Village 10050 N.E.2nd Avenue NE �'ti � Work Clay •"` "' Miami Shores,FL 33138-0000 M* uv e Phone: (305)795-2204 Pe 5; t 20'i6 Expiration: 09/27/2016 Project Address Parcel Number Applicant 1260 NE 99 Street 1132050090160 JAMES&CHRISTA KORRAY Miami Shores, FL 33138-2643 Block: Lot: Owner Information Address Phone Cell JAMES&CHRISTA KORRAY 1260 NE 99 Street MIAMI SHORES FL 33138-2643 Contractor(s) Phone Cell Phone Valuation: $ 30,745.00 MORTON ROOFING INC (954)783-5883 Total Sq Feet: 3468 Type of Work:Re Roof Available Inspections: Additional Info: Inspection Type: Classification:Residential Tin Cap Scanning:4 Final Roof Final Roof Cap Sheet Roof in Progress Renailing Affidavit Review Roof Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-3-16-59232 CCF $18.60 03/31/2016 Check#:3473 $ 1,221.36 $0.00 DBPR Fee $4.88 DCA Fee $4.88 Bond#:3041 Education Surcharge $6.20 Permit Fee-New Roof $325.00 Scanning Fee $12.00 Technology Fee $24.80 Work without Permit Fee $325.00 Total: $1,221.36 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction a zonin Fu ermore,I authorize the above-named contractor to do the work stated. March 31,2016 Auth ' e Si ure: wner / Applicant / Contractor / Agent Date Building Department Copy March 31,2016 1 n Miami Shores village t Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 MAR 3 1 016 ELLTel:(305)795.2204 Fax:(305)756.8972 SPECTION'S PHONE NUMBER:(305)762.4949 FBC 2014 S BUILDING Permit No. �0 PERMIT APPLICATI �'1, Master Permit No. Permit Type: BUILDING ROOFING { a' ' JOB ADDRESS: 1260 NE 99 ST MIAMI SHORES City: Miami Shores County: Miami Dade Zip:33138-2643 Folio/Parcel#: 11-3205-009-0160 Is the Building Historically Designated:Yes NO No Flood Zone: OWNER:Name(Fee Simple Titleholder): JAMES&CHRISTA KORRAY Phone#:_352-208-8182 Address: 1260 NE 99 STREET City: MIAMI SHORES State: FL Zip: 33138-2643 Tenant/Lessee Name: NIA Phone#: Email: CONTRACTOR:Company Name: Morton Roofing, Inc. Phone#: 954-783-5883 Address: 500 NW 12th Avenue City: pompano Beach State: Florida Zip: 33069 Qualifier Name: John B. Morton 111 Phone#: 954-296-1185, State Certification or Registration#: CCC011043 Certificate of Competency#: Contact Phone#: 954-783-5883 (Jill) Email Address:�jil�mortonroofing.com DESIGNER:Architect/Engineer: NIA Phone#: Value of Work for this Permit:$ 30,745.00 Square/Linear Footage of Work: 3,468 Type of Work: ❑Addition DAlteration ONew ZRepair/Replace ODemolition Description of Work: Standing Seam Metal&Flat Deck Re-roof & 4 Color thru .Metal Roof Color:Stone White Submittal Fee$ C& Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ R Bonding Company's Name(if applicable) NIA Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature X l,� Signator IAM Owner or Agent Contractor The foregoing instrument was acknowledged before me this 30ttL The foregoing instrument was acknowledged before me this 30th day of March ,20'x_,by Christa KorW day of March ,2W ,by John B. Morton III who is personally known to me or who has produced FL DL who is personally known to me or who has produced As identification and who did take an oath. NIA as identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: aa .A Sign: Print: Print: Jill S. Tully My Commission Expires:1-1-2019 �y s JutSm d yti�1s My Commission Expires:1-1- „y $' oa pow Comeeuron 0 n lasses Commipl�.=lessee My CMam.bon im 1,1019 My Camra.90M Ja 1.2019 �ksksla:k�k�k:fi3csiaae�k�k%kge�F�k�k�k��k��k�k�k�k�k�k�k�k�F�kak �k�k�k �kafi�k JJnA�k�RnkBank�k�k$agasR�kek�kskB+�kHsgaReka'��k��k�k�ka'�ak�k�fi���k�a�A'�ak�k�a'��fi�k:k�k'k���k� �kak�k�k$ ��k�ksk�k�k�k�k�k�kek 4� APPROVED BY Plans Examiner 3/ ! Zoning Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) if ��.���Elm New Roofs•Reroofs•Repairs QOO�/�� Residential• Commercial �/ License#CCC 011043 A WOR at aBBIRYUBW M2 Oldest Active Roofing License in Broward County— Owner Information Job Information Atte:Christa Korray December 7,2015 Korray Residence Christa Korray Residence 1260 NE 99th Street 1260 NE 99th Street 1260 NE 99th Street FL 33138 Miami Shores FL 33138 (352)208-8182 Page 1 of 3 INSTALLING A HIGHLY UPGRADED METAL ROOF(STUART SERIES)ON THE ENTIRE SLOPE ROOF 30 YEAR WARRANTY CONSUMER PROTECTION: 1. Morton Roofing will furnish the owner with an insurance certificate made directly to the owner. Liability limits are as follows: $1,000,000.00 bodily, property damage $1,000,000.00. Morton Roofing is fully covered by workers compensation to the limits allowed by State of Florida. 2. Local, State and Federal regulations, safety standards and codes shall be followed. The stricter document shall be followed when a conflict exists. 3. Prior to commencement of work, Morton Roofing will furnish all necessary permits for new roof installation. 4. Morton roofing will do everything necessary to protect the customer's property; such as, but not limited to, tarps, trash chutes and plywood coverings. ROOF REMOVAL: 1. Remove the roof, in stages,down to the original wood sheathing. 2. Re-nail all sheathing and replace up to 100 lineallsquare feet of wood sheathing, if rotted,at no extra charge.The existing sheathing must be re-nailed to conform to the Florida Building Code. 3. Chalk lines on rafter centers to insure correct placement of new sheeting nails.Any missed rafters and the sheathing nails will back out of roof causing roof failure. 4. Reset all existing sheeting nails pulled back up by years of structure movement due to the heat and the roof removal process. 5. Decks to be dry,smooth, swept free of all dust,dirt,grime,debris,and kept clean of foreign materials and obstructions. 6. No more roof area will be removed,in one day,than can be kept watertight. 7. A watertight tie-in will be laid at the finish of each day. Continued... 500 NW 121 Avenue Pompano Beach, FL 33069 PH:954-567-3380—Fax:954-567-3379 'gleams list =t u 1-800-548-ROOF •' • r Now Roofs•Reroofs•Repairs Residential• Commercial R88FINO License#CCC 011043 ArtadN#nrrlon51tySf=61W ---Oldest Active Roofing License in Broward County— Owner Information Job Information Attn:Christa Korray December 7,2015 Korray Residence Christa Korray Residence Page 2 of 3 METAL SUB ROOF INSTALLATION: 1. To solid sheathing,tin-tag (nail, no staples)one(1)layer of U.L. rated#30 felt (NOTE: U.L.#30 felt has a stronger supporting mat than regular#30 felt or#43 base sheet.) 2. Install Versa Shield felt to achieve a class "A"fire rating! 3. End of base ply shall be secured and entire sheet shall be pulled taut,and opposite end of sheet shall be secured to hold in place. 4. Fasteners shall be placed in required quantity and pattern to comply with new Dade County protocols and NOA of manufacture. METAL ROOFING SYSTEM: 1. Comply with manufacturers standard instructions and conform to standards set forth in the Architectural Sheet Metal Manual published by SMACNA, in order to achieve a watertight installation. 2. Install panels in such a manner that horizontal lines are true and level and vertical lines are plumbing. 4. Install all trim before installing roof panels;do not walk on the completed roof. 5. Remove protective strippable film prior to installation of roof panels. 5. Attach panels using manufacturer's standard clips and fasteners. 6. Install sealant(s)for performed roofing panels as recommended by the manufacturer. 7. Do not allow panels or trim to come into contact with dissimilar materials. 8. Remove and replace any panels or components,which are damaged beyond successful repair. 9. Exposed edges are permissible due to the galvanic action of the system where the zinc migrates to protect the exposed material. However,efforts should be made to reduce the amount of exposed edges. Metal Panels:To be 24 gauge galvalume, 16"wide. FLAT ROOF SYSTEM: 1. To solid sheathing,tin-tag (nail) 1-layer of COMMERCIAL BASE SHEET. 2. Fasteners shall be placed in required quantity and pattern to comply with the new building code requirements. 3. At the intersection of all roof and vertical surfaces to be flashed, cants shall be installed per membrane manufacturer requirements. 4. With hot steep type IV asphalt, solidly adhere,without voids, 1-layer of GAF COMMERCIAL BASE SHEET. 5. With hot type IV steep asphalt, solidly adhere 1 -layers of GAF RUBEROID 20 MODIFIED MEMBRANE INTERPLY. 6. Install GAF White Surface Mineral Cap Sheet"Class A°to the top of the RUBEROID 20. 7. Loose granules shall be embedded into overrun of hot asphalt at the side and end laps. 8. All felts to be turned up walls and curbs a minimum of 4 inches. Continued.. • 500 NW 121*Avenue Pompano Beach, FL 33069 PFI:954-567-3380—Fax:954-567-3379 �++e i� • 1-800-548-ROOF °� • i e New Roofs•Reroofs-Repairs ���,�� Residential• Commercial License#CCC 011043 a nadrua,doaarrrnsrore 1852 Oldest Active Roofing License in firoward County— Owner ountyOwner Information Job Information Attn:Christa Korray December 7,2015 Korray Residence Chdsta Korray Residence Page 3 of 3 CLEANING: 1.Clean any grease,finger marks or stains from the panels per manufacturer's recommendations. 2. Remove all scrap and construction debris from the site. 3. Leave the premises cleaner than when we started. TECHNICAL NOTES: 1. Due to the inherent qualities as it relates to natural weathering,it is an acceptable industry standard for mill finished galvalume to show variations in its shade of color from panel to panel after installation..None of the above affects the structural integrity of the finished product and is not acceptable reason for rejection.Morton Roofing assumes no responsibility for any unsatisfactory look that can possibly result from this substrate. 2. A certain amount of waviness,called oil canning,is inherent in any product manufactured form coiled sheet metal.The amount of oil canning can vary due to several factors.Minor oil canning of a panel does not affect its structural integrity and is no sufficient cause for rejection. 3. Stiffening ribs will normally decrease the potential for oil canning and are highly recommended. GUARANTEE: 1. Morton Roofing guarantees this highly upgraded METAL,roofing system for a full TEN(10)year(s)against leaks due to labor and/or materials. 2. Owner shall receive a TWENTY(20)year manufacturer's metal guarantee including coverage of materials and labor, subject to manufacturer's normal terms and conditions. 3. Morton Roofing has installed over SIX-million square feet of METAL roofing systems,with no failure. INVESTMENT: • Investment of new roofing system is: $30,745.00 OPTION: Install hurricane mitigation strapping,including engineers report,ADD: $ 3,300.00 TERMS: • Due upon acceptance of proposal: $10,249.00 • Due upon installation of 30#felt: $10,248.00 Balance due upon delivery of all releases and warranties $10,248.00 0pf'ronslC0M=nt6 Plywood is charged @$3.50 per sq.foot 1x Fascia and sheathing boards are charged @$4.50 per lineal foot All 2x Lumber is charged @$6.50 per lineal foot Furring strip 1x2 is charged @$1.50 per lineal foot pany R entahve Date _ Company Acceptance Date: Owner. Date. When this job is accepted please sign and give one copy to the company representative which our&for to proceed with the work and when approved by our Company President constitutes the entire agreement of the parties.This contract maybe with drawn unless signed by the Company President Sqs Slope:31 Sqs Flat 5 Salesman KELLY 500 NW 121*Avenue Pompano Beach,FL 33069 ¢ PA:954567-3380—Fag:954-567-3379 _ 1-800-548-ROOF • �,' Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section A (General Information) Master Permit No. Process No. Contractor's Name Morton Roofing, Inc Job Address 1260 NE 99th Street ROOF CATEGORY /Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile 0000 ❑ Asphaltic Mc Metal Panel/Shingles ❑ Wood Shingles/ - Shingles •• 6fiva.• . 0000.. . 9k Prescriptive BUR-RAS 150 VACS 111I - .... 0000. ROOF TYPE 0000 . BY, . 00000 00 0000.. ❑ New Roof 99 Reroofing ❑ Recovering El Repair 0.Maintenance •• • 000 :0 77, ROOF SYSTEM INFORMATION ` 73 Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 445 3,023 3,468 SECTION B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. MV 20-0- F19 0-0"F19 Roofbi �y er r zo 445 SF o 17 9 o 24'0' - \ U?J _e MDW Roof \ N 3:04 SF m m ----- �. � c hU C2 / 360" �, C f a Florida Building Code Edition 2014 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, identify as"NA") System Manufacturer: GAF Field: 6 "oc @ Lap,#Rows 2 @ 8 "oc NOA No.: 14-1030.02 Perimeter: 6 "oc @ Lap,#Rows 4 @ 6 "oc Design Wind Pressures, Fro RAS 128 r Calculations: Corner: 6 "oc @ Lap,#Rows 4 @ 6 "oc Pmaxl: -42.8 Pmax2: -71.7 Pmax3:-108.0 Number of Fasteners Per Insulation 0000 Max. Design Pressure, From the Specific NOA-62.5 • Board NIA • '0000' 0006.. System: Field: Perimeter " Corner.' 6 •� •••••• •• •• 0000.. Deck: 666:00 6 . . Type: Wood •00000 Illustrate Components NQtgsand •6 • : ' Gauge/Thickness: 6/8"or greater 0 09:00 Details as Applicable: •••••• • • 000000•0••' �1„ Woodblocking, Gutter, Eabe.' TerrrOPfMIl, 666666 Slope: Stripping, Flashing, Contirwoiwe.Cleat, Qant 6 Strip, Base Flashing, Cour?tet- Flashigg, 6666:6 Anchor/Base Sheet&No.of Ply(s):1 ply-GAFGlass 76# Coping, Etc. 6 6 0 6.6•• 6 6 Anchor/Base Sheet Fastener/Bonding Material: Indicate: Mean Roof HeigHR66f'aiapet �g�ht, :••••: 1-1/4"Ring Shank Nails and Tin Caps Height of Base Flashing, Component Mgierial, Material Thickness, Fastener Type, Fastener Insulation Base Layer: NIA Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Base Insulation Size and Thickness: NIA Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: NIA FT N/A Parapet Top Insulation Size and Thickness: NIA Height Top Insulation Fastener/Bonding Material: NIA 12 Base Sheet(s)&No.of Ply(s): N/A Wood Mean Base Sheet Fastener/Bonding Material: Roof NIA Height Ply Sheet(s)&No.of Ply(s): 1 Ply-GAF Ruberold 20 Ply Sheet Fastener/Bonding Material: Hot Asphalt 1.Base sheet set In hot asphalt Top Ply: 1 Ply-GAF Glass Cap Mineral Surfaced Cap 2.GAF Ruberold 20 set in hot asphalt 3.Mineral Surface Cap Sheet in hot asphalt Top Ply Fastener/Bonding Material: a.SBS Modified Base Flashing Hot Asphalt Surfacing: Granuals oof is more than 0' from neighbors Florida Building Code Edition 2007 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: Sunlast Metals Notice of Acceptance Number: 12-0719.02 Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): Pmax1: -39.1 Pmax2: -68.1 Pmax3: -100.7 Maximum Design Pressure a .'. • (From the NOA Specific System): -106.75 •• ••• ••::• eeeee• Method of Tile Attachment: NIA-Metal Panels affixed with 1"#10 Pancake head screws every 11reW NOA • • ••••• 00000 e e . • .. e. . ..... e • e • e Sloped System Description ..... eeeeee . . oeeee .. . eeee eck Type: I wood ' Type Underlayment: 1 30# nsulation: n/a Roof Slope: 4 :12 Fire Barrier: Versa Shield -NOA 11-1110.09 Fastener Type&Spacing: iaas2rs1ks6"on a , o 2oc dhesive Type: I N/A Ridge Ventilation? N/A ype Cap Sheet: I N/A oofing Covering: standing Seam Metal Panels Type&Size Drip dge: 3"x3"Galvalume 26 Gauge Mean Roof Height: 14• Owner's Notification Form 07 MOAMI-DA®E) ` SECTION 1524 HIGH VELOCITY HURRICANE ZONES--REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Floridu Building Code,.wilding govern the minimum requirements and standards of the industry for rooting system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. U© 1. Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workinai ulaip provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zona g.c'ode, sht�,tltt be addreved as part of the agreement between the owner- and the contractor. O- i 2. Renailing wood decks: When replacing roofing, the existing wood root jcck may h vg to bi.... renailed in accordance with the current provisions of Chapter 16 (High Velocity Hu>'tleane Zones}ef the-Florida Building Code. (The roof deck is usually concealed prior to removing the existingye�syster* ?goes *0:0* •..... �® 3. Common roofs: Common roofs are those which have no visible delinCatibr,betweeri peighbon-n*L units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the rpofrtp conVa-c"or and/or owner should notify the occupants of adjacent units of roofing work to be performed' s ' .. . C 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining this appearance. 0® 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. t' 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded frorn a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 15 and 16 herein and the Florida wilding Code, Plumbing. �© 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida-licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's/Agent's Signature: < Date: Contractor's Signature: Permit Number: Property Address: LZ�O r .ct S u . 14t111 MIAMI-DADE COUNTY ® - PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/pera Sunlast Metals Inc. 2120 SW Poma Dr. Palm City,FL.34990 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction maWMs.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Cont?WSa&on to,0 9 9 9 9 be used in Miami Dade County and other areas where allowed by the Authority Having JurisdieAoa(AHJJ. 4 : • 000000 96 49 0649.0 This NOA shall not be valid after the expiration date stated below. The Miami-Dade C®xili*Product Gontrol • 0000.. Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade Couno emirve d'1ps ripA to • have this product or material tested for quality assurance purposes. If this product or material TAils to p&folM in ••;•• the accepted manner, the manufacturer will incur the expense of such testing and the RHS'hay in- edikely revoke, modify, or suspend the use of such product or material within their jurisdiction. PMA reserves the right •• to revoke this acceptance, if it is determined by Miami-Dade County Product Control Secti*Vri9qj this aro4t or 4••„• material fails to meet the requirements of the applicable building code. 0 6 :0000* This product is approved as described herein,and has been designed to comply with the Florlda$uilding Cog”4 :"": including the High Velocity Hurricane Zone of the Florida Building Code. •• • DESCRIPTION: 1"Nail Strip Steel Roofing Panel LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 12-0319.11 and consists of pages I through 5. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0719.02 MIAMMADE COUNTY Expiration Date:02/28/18 Approval Date:02/14/13 Page I of 5 ROOFING SYSTEM APPROVAL: Cateeory Roofing Sub-Category: Metal,Panels(Non-Structural) Material: Steel Deck Type: Wood Maximum Desien Pressure -106.75 psf(See System Limitation#2) TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specifications Description 1"Nailstrip Panel 1=varies TAS 110 Corrosion resistant,galvanized,pre"f9�fl, e..... w= 16" TAS 125 lapped,coated,prefinighet?,it►etal pmels.. .' Min.Thickness 0.0217" ... • ' • ... .. .. ...... (24ga.) • .... .. .. ..... 000 ...... . . ..... MANUFACTURING LOCATION: :""' ...... 1. Palm City,FL. """ '• EVIDENCE SUBMITTED: ' ' ' •••e•• Test Agency Test Identifier Test Name/Renort •• Date Hurricane Test Laboratory,LLC. 0412-0306-06 TAS 125 9/26/07 REV A 0412-1203-07 01/23/08 0412-0621-07 09/26/07 PRI Asphalt Technologies,Inc. SFMS-002-02-01 TAS-100 03/17/06 Akzo Nobel Coatings,Inc. Laboratory Certification ASTM G23 10/17/01 ASTM B117 MIAMI•DADE COU NOA No.: 12-0719.02 � � Expiration Date:02/28/18 Approval Date:02/14/13 Page 2 of 5 APPROVED ASSEMBLIES: System: I"Nail Strip Steel Roofing Panel Deck Type: Wood,Non-insulated Deck Description: New Construction or Re-roof 15/32"or greater plywood or wood plank. Slope Range: 2": 12"or greater Maximum Uplift See Table A below Pressure: Deck Attachment: In accordance with applicable Building Code,but in no case shall it be less than 8d ring shank nails spaced 6"o.c. In reroofing,where the deck is less than 19/32"thick(Minimum 15/32")the above attachment method must be in addition to existing attachmegt•••• . . .... ...... Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed 14ji a miNjmuna 4" .• side-lap and 6"end-laps.Underlayment shall be fastened with cQupsim resisUr1t"J-caps....:. and 12 gauge 1 '/4"annular ring-shank nails,spaced 6"o.c.at all,141p;cod two staggered •••• rows 12"o.c.in the field of the roll. Or,any approved underlaMe*e1gving a.euvet NOA. • Fire Barrier Board: An approved fire barrier having a current NOA. Refer to a c •••• dire to •istin f•(�•••• Y PP g G irk g rY 1 g 449 0 • fire ratings of this roofing system assembly as well as the locatioA8f Elie fire b'tLM withi0..... ® the assembly. See Limitation# 1. • Valleys: Valley construction shall be in compliance with Roofing Application Slandar:6RA%133 •••••• and with the current published installation instructions and detai&i1rAJnlast l%SVL Inc's,:•••• Installation Manual. • • Metal Panels and Install the "I" Nail Strip Panel" and accessories in compliance with Sunlast Metal, Inc's Accessories: current, published installation instructions and details. Flashing, penetrations, valley construction and other details shall be constructed in compliance with the minimum requirements provided in Roofing Application Standards RAS 133. 1. l"Nail Strip Roofing panels shall be attached to the plywood substrate along its male rib with a minimum of#10 x I"pancake head,corrosion resistant fasteners attached 3"from each panel end and at a maximum spacing as listed in Table A below. Fasteners shall be of sufficient length to penetrate through the sheathing a minimum of 3/16 inch. 2. Apply a 1/16"bead of Bostik®Chem Calk®915 Polyurethane adhesive/sealant atop the rear leg of the male joint,adjacent to the fasteners and along the entire length of the panel. 3. Attach adjacent panel by placing the female rib over the adhesive and over the male rib. TABLE A MAXIMUM DESIGN PRESSURES Roof Areas Field Perimeter and Corner Maximum Design Pressures -84.25 psf -106.75 psf Maximum Fastener S acing 12"o.c. 6"o.c. 1. Extrapolation shall not be allowed NOA No.: 12-0719.02 M AMI-CMDeCOUNTY Expiration Date:02/28/18 I Approval Date:02/14/13 Page 3 of 5 LIMITATIONS 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field,perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge.Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami-Dade County Product Control Approved"or with the Miami-Dade County Product Contrgl.4eal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo,and/or m8dgL.' 0000.. MIAMI•DADECOUIVTY •••••• •• •• •••••• 0000.. Mn 0000.. 0000 5. All products listed herein shall have a quality assurance audit in accordance with the '18=ifla*BuildM&CD44e and 6.0 6' Rule 9N-3 of the Florida Administrative Code. 0000.. . . . . 000.00 0000.. . .0600. 66 6 600. 6 6 . 6 NOA No.: 12-0719.02 MIAMI-DADECOUt Expiration Date:02/28/18 Approval Date:02/14/13 Page 4 of 5 PROFILE DRAWINGS 16"Coverage 0100 Striations Optional 1010. • 1010 . . 090.09 .. 1010 1010.... .00009 . .. 10 10 1010.... . 00 . i 1010.. .. .. .0909 1010.... . . 1010... . 1010.... 9. .. . 1010.... 1010.... . . 1010.... 1010.... Z . . 10 ....1010 10 06.10 . Bead of Bostik Chem-Caulk 915 adhesive Fastener Spacing as per Table A herein END OF THIS ACCEPTANCE NOA No.: 12-0719.02 CMMMUD�ADECQUNTY Expiration Date:02/28/18 Approval Date:02/14/13 Page 5 of 5 5/9/13 TGFU.R25723-Roofing Systems U� DNuor: cERTIFIcmioNs pigECTORY TGFU.R25723 Roofing Systems Paoe Bottom Roofing Systems See General Information for Roofing Systems SUNLAST METAL INC R257236*0 0 2120 SW POMA DR ' . . 0000 0000.. PALM CITY, FL 34990-6615 USA " • • 00000• Sao** .0060. 6 OTHERSYSTEMS 0•::•o • : 6 0 . • 0 6006 60 00 66066 Class A ' 0000.. 1. Deck: C-15/32 or spaced sheathing Incline: Unlimited •••••• • • . . :906:0 . 0 Underlayment: — One layer Elk "VersaShield Underlayment", mechanically fa;terfl. • Ply Sheet: — One layer Type 30 base sheet or Elk "VersaShield", mechanicallyfast1ened..1';'. • Panels: — "1" Snap Lock Standing Seam- Nail Strip (Steel) (Stuart Series)," "5-V Crimp (Vteel) (Key West Series)," "1-3/4" Snap Lock Standing Seam (Steel) (Miami Series)," "PBR Panel (Steel) (Ocala Series)," and "1-1/2" Mechanical Standing Seam (Copper Clad Steel) (Palm Beach Series)" 2. Deck: C-15/32 or spaced sheathing Incline: Unlimited Underlayment: — One or more plies Elk "VersaShield Underlayment", mechanically fastened. Panels: — "1" Snap Lock Standing Seam- Nail Strip (Steel) (Stuart Series)," "5-V Crimp (Steel) (Key West Series)," "1-3/4" Snap Lock Standing Seam (Steel) (Miami Series)," "PBR Panel (Steel) (Ocala Series)," and "1-1/2" Mechanical Standing Seam (Copper Clad Steel) (Palm Beach Series)" 3. Deck: C-15/32 Incline: Unlimited Underlayment: — Two layers Elk "VersaShield Underlayment". Panels: — "1-3/4" Snap Lock Standing Seam (Aluminum) (Miami Series)," Last Undated on 2010-03-16 Questions? Print this page Terms of Use Paae Too © 2013 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL pemrots the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. databme.d.com/cg i-bintMttemplate/USEXT/1 FRAM E/showpage.htrtd?name=TGFU.R25723&ccnshorVjte=Robing+Systems&objid=1079308122&cfg id=107... 1/2 3 • 5013 TGFU.R25723-Roofing Systems The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice �in the following format: "© 2013 UL LLC". 0000 . . 9999 999999 0000.. 0000 0000.. 0000.. 0000.. 0000 . . 0000 0000 0000. 0000.. . . 09.00 9999.9 0000 . 0000.. 0000.. 0000.. . . 999999 .. 9 9.99 9 9 9 database.d.com/cgi-bin0M/W0atetUSEXT/1 FRAM E/shaAM e.hVd?name=TGFU.R25723&ccnshortbte=Roofing+Systems&objid=1079308122Wgid=107... 212 IrlIAMI-CDAD 1 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY 11805 SW 26 Street,Room 208 AFFAIRS(PERA) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/pera GAF Material Corporation 1361 Alps Road Wayne,NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the.0.0• . . 0000 0000 Authority Having Jurisdiction(AHJ). 0• This NOA shall not be valid after the expiration date stated below. The Miarrg.Dado Couni}fi'0: .0 0 0:0 Product Control Section (In Miami Dade County) and/or the AHJ (in areas other thttis•kami Dade 0 County) reserve the right to have this product or material tested for qualityassura>;d� ose 1f :6000: this product or material fails to perform in the accepted manner, the manufacturer wtR incur 018 00 00:0.0 expense of such testing and the AHJ may immediately revoke, modify, or suspend tiie0Ilse of s-0h.:0 000946 •0.0:. Product or material within their jurisdiction. PERA reserves the right to revoke thisGGrDce,if it . is determined by Miami-Dade County Product Control Section that this product or:natenal fails to .. 0 0.0 0 0 meet the requirements of the applicable building code. 0.0 0000. 0 0 .00000 This product is approved as described herein,and has been designed to comply with tie Florida Buil 19 ' Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: VersaShielde Fire Resistant Roof Deck Protection and VersaShieldo Solo Fire Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 10-0331.04 and consists of pages 1 through 3. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 11-1110.09 Expiration Date: 02/07/17 MIAMMAD,C01 4 y � Approval Date: 01/26/12 'g -�. , Page 1 of 3 ROOFING COMPONENT APPROVAL Category Roofing Sub-Category: Underlayment Material: Fiberglass SCOPE: This acceptance is for VersaShield Fire Resistant Roof Deck Protection(a.k.a"VersaShield Underlayment")and VersaShield Solo Fire Resistant Slip Sheet(a.k.a"VersaShield Solo"),as described in this Notice of Acceptance,for use with approved prepared roof assemblies.Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: 0000 Test Prpdul • Product Dimensions •••• •••••• Specification DesUpWa • VersaShield®Fire 42"x 100' rolls ASTM D 226 Type II Non-Asphaltic fiberglass-based..•.: 0000:. Resistant Roof underlayment and/br:6 barrier. • .0000. Deck Protection "'. .• ; 0000 00 96 ....9 VersaShield Solo 72"x 166.7' rolls UL790 Non-Asphaltic fib®r�la ss-basad slit. 69:066 Fire Resistant Slip sheet and/or fire bllrcier. 0000:6 .96.9. Sheet • . . . . 6 0000.. 69999 MANUFACTURING LOCATION: • • • 0 9 6 9 9 9 69 . 6060 . 6 1. Conover,NC 6 • EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GAF-270-02-02 ASTM D 226 11/15/10 ELK-063-02-01 TAS 100 09/27/01 Underwriters Laboratories Inc. 99NK45831 UL790 03/21/00 1ONK11990 UL790 05/18/11 R19254 ASTM D 226 09/13/01 08CA37926 UL790 09/23/09 08CA49140 PRI Asphalt Technologies, Inc. ELK-069-02-01 TAS 100 03/04/02 BRY-003-02-01 TAS 117(B) 03/19/02 BRY-003-02-01 TAS 114(H) INSTALLATION: 1. VersaShield Fire Resistant Roof Deck Protection or VersaShield Solo Fire Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield®Fire Resistant Roof Deck Protection or VersaShield®Solo Fire Resistant Slip Sheet shall be installed with a minimum 4-inch head lap in a shingle layer fashion. 3. VersaShield®Fire Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type H underlayment. NOA No.: 11-1110.09 ANAMIROADE COUNTY Date: 02/07/17 r�nar�annoe counmr Approval Date: 01/26/12 Page 2 of 3 i LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield®Fire Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application.VersaShield Solo Fire Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield® Fire Resistant Roof Deck Protection and VersaShield® Solo Fire Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. *000 5. VersaShield® Fire Resistant Roof Deck Protection or VersaShield®Solo Fire aResistant SltpS wet may be used with any approved roof covering Notice of Acceptance listing-WersaShieldo Fite Resistant Roof Deck Protection or VersaShield® Solo Fire Resistant Slip ShMnly be used as*a ••••:. component part of an assembly in the Notice of Acceptance. If VersaShield*We Resistant Roof Deck Protection or VersaShield®Solo Fire Resistant Slip Sheet is not listed,a request may b m $e 99 to the Authority Having Jurisdiction(AHJ) or the Miami-Dade County Product.,Qj"ol Department . for approval provided that appropriate documentation is provided to detail.Q tnpAtibili1v bf Vie products,wind uplift resistance, and fire testing results. ••.... 6. VersaShield® Fire Resistant Roof Deck Protection and VersaShield®Solo Fire'Resistant S4,54get •••••• are a non-asphaltic underlayment that may be used as a fire barrier for prepared roof ossemb�li es. For fire classification of specific roof assemblies using VersaShield® Fire Resistant Rool.deck Protection or VersaShield Solo Fire Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code LABELING: All packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and yellow line to identify the ASTM Standard designation; or logo and the following statement: "Miami- Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI DADE COUNTY ...f BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE NOA No.: 11-1110.09 Expiration Date: 02/07/17 MtAMt°A°�couNrY Approval Date: 01/26/12 Page 3 of 3 MIAMIAADE. MIAMI-DARE COUNTY • PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.Wamidade.gov/economy GAF 1 Campus Drive Parsippany,NJ 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). ."'•0 . . 0000 000600 This NOA shall not be valid after the expiration date stated below.The Miami-Dade to"Product 0• Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami fXtlraGounty}••*•: 6 6 6 6: reserve the right to have this product or material tested for quality assurance purposes.1f RA product er :0000: material fails to perform in the accepted manner,the manufacturer will incur the expans�oflsuch testing, 0 and the AHJ may immediately revoke,modify,or suspend the use of such product ormtmal withm 0*000 6 . their jurisdiction. RER reserves the right to revoke this acceptance,if it is determined^0ami-l:'adC•• 000000 County Product Control Section that this product or material fails to meet the requiremantc of the 'm• applicable building code. :00*:* •••• • This product is approved as described herein,and has been designed to comply with;r.F1Qrida E61(d pg ;•••• Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Ruberoid®Modified Bitumen Roof System for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida,and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 14-0611.01 and consists of pages 1 through 30. The submitted documentation was reviewed by Jorge L.Acebo. NOA No.: 14-1030.02 MAMI•DADECOUNTY Expiration Date: 11/06/18 rMfiflie'rRIJ Approval Date: 11/05/15 Page 1 of 30 ROOFING SYSTEM APPROVAL Category Roofing Sub-Category: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Matrix 102 SBS Membrane 5 gallons ASTM D3019 Fiber reinforced rubberized cold-applied Adhesive adhesive for modif ed bitumen foo f 0. •••••• systems. • GAFGLAS®#75 39.37' ASTM D4601 Type H asphalt imps ed an$ h44d ••.•;• Base Sheet (1 meter)Wide glass mat base sheet•••• GAFGLAS®#80 Ultima'Base 39.37' ASTM D4601 Type II asphalt impfCgtl$,ted anftgat;d, %••••: ... •• •• ..... Sheet (1 meter)Wide fiberglass base shee • GAFGLAS®FlexPlyT.6 39.37" ASTM D2178 Type VI asphalt iji9j neted gfam felt �����• (1 meter)Wide with asphalt coati4g.••• GAFGLAS®Ply 4 39.37" ASTM D2178 Type IV asphalt irLpre'gdated gjass felt •••,;• (I meter)Wide with asphalt coatixg. :••"' GAFGLAS®Mineral Surfaced 39.37" ASTM D3909 Asphalt coated,glaS3 fiber mat.eap sheet :•••': Cap Sheet (1 meter)Wide surfaced with mineral granules.•• • GAFGLAS®EnergyCar 39.37" ASTM D3909 Asphalt coated,glass fiber mat cap sheet BUR Mineral Surface Cap (1 meter)Wide surfaced with mineral granules with Sheet factory applied EnergyCote' GAFGLAS®Stratavent® 39.37" ASTM D4897 Fiberglass base sheet coated on both sides Eliminator'Perforated (1 meter)Wide with asphalt. Surfaced on the bottom side Venting Base Sheet with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS®Stratavent® 39.37" ASTM D4897 A nailable,fiberglass base sheet coated on Eliminator"'Perforated (1 meter)Wide both sides with asphalt. Surfaced on the Nailable Venting Base Sheet bottom side with mineral granules embedded in asphaltic coating. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld'Smooth (1 meter)Wide polymer-modified asphalt and smooth surfaced. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld'Granule (1 meter)Wide polymer-modified asphalt and surfaced with mineral granules. RoofMatch' 107 sq.ft. ASTM D6164 Non-woven polyester mat coated with SBS Modified Granular (9.9 m2) SBS polymer-modified asphalt and surfaced with colored mineral granules. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld' 170 FR (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules. NOA No.: 14-1030.02 0:160 Expiration Date: 11/06/18 JAPPROVEDL__ Approval Date: 11/05/15 Page 2 of 30 Test Product Product Dimensions Specification Description Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld'Plus (1 meter)Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid®SBS 39.37" ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld"Plus FR (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoid®EnergyCap'SBS 39.37' ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld" Plus FR (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid®SBS 39.37' ASTM D6163 Non-woven polyester mat coated with Heat-Weld"25 (1 meter)Wide polymer-modified asphalt and srook surfaced. • .• 0000 •••••• . Ruberoid®Mop Granule 39.37' ASTM D6164 Non-woven polyes4 r-mal coats wid (1 meter)Wide polymer-modified c SD$g4 and surfriced with mineral granules.. 0 0 �•••• Ruberoid®Mop Smooth 39.37' ASTM D6164 Non-woven polyest"xat coated W10 (1 meter)Wide polymer-modifiedasphat and 1oo�h •.:..' surfaced. '• .. •••••• Ruberoid®Mop Plus 39.37' ASTM D6164 Non-woven polyester 94 coated vrith • (1 meter)Wide polymer-modified�sph�ft and 6faead " with mineral gran11W• •••••• Ruberoid®Mop 170FR 39.37' ASTM D6164 Non-woven polyester mat coatWit$fire (1 meter)Wide retardant polymer modified asphalt and surfaced with mineral granules. Ruberoid®Mop FR 39.37' ASTM D6164 Non-woven polyester mat coated with fire (1 meter)Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoid®Torch Smooth 39.37' ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and smooth surfaced. Ruberoid®Torch Granule 39.37' ASTM D6222 Non-woven polyester mat coated with (1 meter)Wide APP modified asphalt and surfaced with mineral granules Ruberoid'EnergyCap"Torch 39.37' ASTM D6222 APP modified cap membrane with a torch Granule FR (1 meter)Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote"''. Ruberoid®EnergyCap"Torch 39.37' ASTM D6222 APP modified cap membrane with a torch Granule Plus FR (1 meter)Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote". RooflVlater 107 sq.ft. ASTM D6222 Non-woven polyester mat coated with APP Modified Granular (9.9 m2) APP polymer-modified asphalt and surfaced with colored mineral granules. Ruberoid®Torch FR 1 meter ASTM D6222 Non-woven polyester mat,coated with fire (39.37')Wide retardant asphalt modified bitumen membrane with granule surface. NOA No.: 141030.02 I•pAwe COUNTY Expiration Date: 11/06/18 �Mweygqll Approval Date: 11/05/15 Page 3 of 30 Test Product Product Dimensions Specification Description Ruberoid®20 1 meter ASTM D6163 SBS modified asphalt base sheet reinforce (39.37")Wide with a glass fiber mat. Ruberoid®30 1 meter ASTM D6163 Non-woven fiberglass mat coated with (39.37")Wide polymer modified asphalt and surfaced with mineral granules. Ruberoid®30 FR 1 meter ASTM D6163 Non-woven fiberglass mat coated with fire (39.37")Wide retardant,polymer-modified asphalt and surfaced with mineral granules. Ruberoid®EnergyCap"30 FR 1 meter ASTM D6163 Non-woven fiberglass mat coated with fire SBS Membrane (39.37")Wide retardant,polymer-modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. .00--. Ruberoid®Dual FR 39.37" 1 meter ASTM D6162 Non-woven polyester a$d fiber �S lnat ••••;• ( ) Po Y • � • Wide coated with file ret•a� t=polymer. . modified asphalt apd�aced wit%•• •••••• mineral granules. •••• • . ;••••• Topcoat®Elastomeric Roofing 1,5 or 55 gallons ASTM D6083 An acrylic,water ba�eIastoxn®aic.: 0 9• Membrane membrane system tie tMd to$ro0tj jt •.... • various types of rdo"firig surfac8s. •••••• Topcoat®MB Plus 5 or 55 gallons Proprietary Water based,low V(WTrimer use$to • • 0000.. block asphalt bleed-through. ;••••• • Topcoat® 5 gallons ASTM D6083 Solvent based sprWe:hermo]pWj;ic ;•••• Surface Seal SB rubber sealant designed to protect Ina restore aged roof surfaces and to increase a roofs reflectivity. FireOut7 Fire Barrier Coating 5,55 gallons Proprietary Low VOC,water-based fire barrier coating. VersaShield® 42"x 100'rolls ASTM D226 Non-Asphaltic,fire resistant fiberglass- Fire-Resistant Roof Deck based underlayment. Protection NOA No.: 14-1030.02 MIAMtiDADE COUNTY Expiration Date: 11/06/18 --IAPPROVEDI Approval Date: 11/05/15 Page 4 of 30 APPROVED INSULATIONS: Table 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuard"Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard""RA Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard'RN Polyiso Insulation Polyisocyanurate foam insulation GAF EnergyGuard"Perlite Recover Board Perlite recover board GAF EnergyGuard"Perlite Roof Insulation Perlite roof board GAF EnergyGuard'RA Composite Polyiso Polyisocyanurate/wood fiberboard GAF Insulation or perlite composite •. ' .••••. Structodek®High Density Fiber Board High density wood fiber Blue lidge 1%erBva rd ,lnc. . 0000.. .. •• •6••6• Securock®Gypsum-Fiber Roof Board Gypsum board UniteASftes Gyp Corp. • 00000 0000.. . . 0000 ••00 0•• 0000• APPROVED FASTENERS: •••.•• • TABLES ..•*go 0000•• 0.00.. Fastener Product Product 6••Manufacturgr •• Number Name Description Dimensions ;With Current NOA) ' .0600• 0000.. 1. Drill-Tec"m#12 Fastener Carbon steel fastener used Various GAP • ..... in steel or wood decks. .. 0000 0 • •• 2. Drill-Tec'#14 Fastener Carbon steel fastener used Various GAF in steel,wood or concrete decks. 3. Drill-Tec'XHD Fastener Carbon steel extra heavy Various GAF duty fastener used in steel decks. 4. Drill-Tec'AccuTrac®Flat AZ-SS aluminized steel 3"x 3" GAF Plate plate for use with Drill- Tec'#12 Fastener,Drill- Tec'#14 Fastener and Drill-Tec'#15 Fastener. 5. Drill-Tec' ASAP 3S Drill-Tec'#12 fastener Various GAF with Drill-Tec'3" Standard Steel Plate. 6. Drill-Tec'AccuTrac® Galvalume Steel plate for 3"x 3" GAF Recessed Plate use with Drill-Tec' fasteners. 7. Drill-Tec'3"Steel Plate Round galvalume steel 3" GAF stress plate for use with Drill-Tec'fasteners. 8. Drill-Tec'3"Standard Round galvalume plated 3" GAF Steel Plate steel stress plate with reinforced ribs for use with Drill-Tec'fasteners. NOA No.: 14-1030.02 Mvi w►oe couNrr Expiration Date: 11/06/18 ••• Approval Date: 11/05/15 Page 5 of 30 EVIDENCE SUBMITTED: Test Agency Test Identiifier Description Date Factory Mutual Research Corp. 3001276 FMRC 4470 01/28/99 1B9A8.AM FMRC 4470 09/04/97 3D4Q2.AM FMRC 4470 04/30/97 OD1A8.AM FMRC 4470 04/01/98 Underwriters Laboratories [ 1306 UL 790 07/22/13 Trinity Engineering 4483.04 97-1 TAS 114 06/06/97 IRT-ARCON Inc. 02-005 TAS 114 03/01/02 02-014 TAS 114 04/0$102, 01-039 TAS 114 • 03/&02.` ...... Trinity ERD G30250.02.10-2 ASTM D6222 ...... 1 ur1 jG,: •• G30250.02.10-3-R2 ASTM D3909 •••:•• 06/03/15 . G31360.03.10 ASTM D6164 ,•••• 03/11,/10 G33470.01.11 ASTM D6164 "" 01/13/41100 ••••• G34140.04.11-2 ASTM D6163 ":": 04/2S/JJ:. "'•• .. .. ...... G34140.04.11-4-R2 ASTM D4601 ••• •• 6AN 15 G34140.04.11-5-R3 ASTM D4897 ' : 6/4/02015, •• • G40620.07.12-2 ASTM D6222 074 ANT O % , G40630.01.14-1 ASTM D6163 ••* O1/96A-4• :"": G40630.01.14-2A ASTM D5147 0 110114• G40630.01.14-2A-1-Rl ASTM D6164 04/10/14 G40630.01.14-2B-Rl ASTM D6164 01/16/15 G40630.01.14-2C ASTM D6164 01/07/14 G40630.03.14 ASTM D5147 03/06/14 G43190.03.14-1 ASTM D5147 03/06/14 G43190.03.14-2 ASTM D5147 03/06/14 G43190.05.14-R1 ASTM D5147 05/20/14 G43190.11.13-1 ASTM D6222 11/15/13 G43610.01.14 ASTM D5147 01/22/14 G46160.02.15-21) ASTM D6163 02/03/15 G46160.03.15 ASTM D6163 03/11/15 G46160.09.14-2A ASTM D5147 09/09/14 G46160.09.14-3A ASTM D6164 09/09/14 G46160.09.14-3B ASTM D6164 09/09/14 G46160.09.14-3C ASTM D5147 09/09/14 G46160.12.14-3E ASTM D6164 12/29/14 G6850.08.08 ASTM D6163 08/01/08 G6850.08.08-R1 ASTM D6164 04/14/11 66850.10.08 ASTM D6222 10/06/08 G6850.11.08 ASTM D6222 02/17/09 SC6870.08.14-R1 ASTM D3909 09/04/14 NOA No.:14-1030.02 MAW E-0-UhMM Expiration Date: 11/06/18 ••• Approval Date: 11/05/15 Page 6 of 30 EVIDENCE SUBMITTED: (CONTINUED) Test Aaencv Test Identifier Descriotion Date PRI Construction Technologies LLC. GAF-084-02-01 ASTM D6083 07/08/05 GAF-122-02-01 TAS 139 05/07/06 GAF-245-02-01 ASTM D6083 06/10/10 GAF-276-02-01Rev ASTM E2178 01/04/11 ASTM D6083 GAF-306-02-01 ASTM E96 07/07411'• GAF-314-02-01 ASTM D2178 ••• 08/23f?1'• ••••;• GAF-315-02-01 ASTM D2178 08/23711 GAF-369-02-01 ASTM C1289 '••:O o 10/227f2 00 """ GAF-46402-01 ASTM C1289 *•::•• 02/06114 0 ;•••• GAF-499-02-01 'o.o.0 03/1?1140: 000•. 99-02-01 ASTM D6083 0000 GAF-500-02-01 ASTM D6083 0••0•• 03/1-2/14. 00000 0 .00.0. .. .. . 9999.. Momentum Technologies,Inc. AX04C9A ASTM D6162 ...... 06/05/0$ 0• . . . . . . . 0000.. 0000.. . . . 0000. 00 0 NOA No.: 14-1030.02 MIAMI D E COUNTY Expiration Date: 11/06/18 •�• Approval Date: 11/05/15 Page 7 of 30 Membrane Type: SB SBS Cold Applied Deck Type 1: Wood,Non-insulated Deck Description: 19/32"or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOut'°'Fire Barrer Coating,VersaShield®Fire-Resistant Roof Deck Protection (optional) or Securock®Gypsum-Fiber Roof Board •••• . 0000 0000.. Base sheet: GAFGLAS®#80 Ultima.'°°Base Sheet,GAFGLAS®StratavJ Pli3ninator: Nailable Venting Base Sheet,Ruberoid®20,Ruberoid®SBS XeatWeld"'wool 9.900 or Ruberoid®SBS Heat-Weld"25 base sheet mechanically Weii&to deck as :9090: described below: 9" 0000 0000 0000. Fastening GAFGLAS®Ply 4,GAFGLAS®FlexPlyTm 6,GAFGLAS®#75��,lheet q� ••0••0 Options: of above base sheets attached to deck with approved annular rh►*g Wank nails and "•9.. tin caps at a fastener spacing of 9"o.c.at the lap staggered and M0 fwe rows 12'I . . . . o.c.in the field. •••••• 000000 .0900. (Maximum Design Pressure—45 psf.See General Limitation 7,i' 0.06 0 0 GAFGLAS®Ply 4,GAFGLAS®F1exPly"'6,GAFGLAS®#75 Base Sheet or any of above base sheets attached to deck with Drill-TecT"#12 Fastener,Drill-Tec' #14 Fastener or Drill-Tec'XHD Fastener and Drill-Tec'3"Steel Plate,Drill- Tec'AccuTrac®Flat Plate or Drill-Tec'AccuTrac"Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 12"o.c.in the field of the sheet. (Maximum Design Pressure-,45 psf.See General Limitation#7) GAFGLAS®FlexPly 6,111GAFGLASI#75 Base Sheet r any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9"o.c.at the 4"lap staggered and in two rows 9"o.c.in the field. (Maximum Design Pressure—52.5 psf.See General Limitation#7) GAFGLAS®#80 Ultima'Base Sheet,Ruberoid®20,Ruberoid®Mop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9"o.c.at the 4"lap staggered and in two rows 9"o.c.in the field. (Maximum Design Pressure—60 psf.See General Limitation#7) GAFGLAS®#75 Base Sheet or any of above base sheets attached to deck with Drill-Tec'°'#12 Fastener,Drill-Tec'#14 Fastener or Drill-Tec'XHD Fastener and Drill-Tec'3"Steel Plate,Drill-Tec'AccuTrac®Flat Plate or Drill-Tec' AccuTrac®Recessed Plate installed 12"o.c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c.in the field of the sheet. (Maximum Design Pressure—60 psf.See General Limitation#7) Any of above base sheets attached to deck approved annular ring shank nails and 3"inverted Drill-Tec''insulation plates at a fastener spacing of 9"o.c.at the 4" lap staggered in two rows 9"in the field. (Maximum Design Pressure—60 psf.See General Limitation#7) NOA No.: 14-1030.02 CMhAMPffiWADEW=UNTY Expiration Date: 11/06/18 Approval Date: 11/05/15 Page 26 of 30 Fastening GAFGLAS'#75 Base Sheet or any of above base sheets attached to deck with Options: Drill-Tec'#12 Fastener,Drill-Tec'#14 Fastener or Drill-Teo'XHD Fastener (Continued) and Drill-Tec'3"Steel Plate,Drill-Tec"M AccuTrac®Flat Plate or Drill-Tec' AccuTrac'Recessed Plate installed 8"o.c.in 4 rows. One row is in the 2"side lap. The other rows are equally spaced approximately 9"o.c.in the field of the sheet. (Maximum Design Pressure—75 psf.See General Limitation#7) Ply Sheet: (Optional)One or more plies GAFGLAS'Ply 4,GAFGLAS'F1exPly 6, GAFGLAS'#80 Ultima Base Sheet,Ruberoid®Mop Smooth or Ruberoid®2Q.. sheet adhered in a full mopping of approved asphalt applied within 4he EV T range 0 0 0 0 and at a rate of 20-40 lbs./sq. •• • 0000.. .. .. 0000.. Membrane: One or more plies of Ruberoid'Mop Smooth,Ruberoid'Mop.17 FR,Ruberoid' Mop Granule RoofMatch'SBS Modified Granular,Ruberoid,16ldk);Plus • Granule,Ruberoid'20, uberoid'30,Ruberoid'EnergyCap"30�*ft SBS •• •• ••••• . . Membrane,Ruberoid 30 FR or Ruberoid'Mop FR in adhered ir;a'f+<ill mooff of approved asphalt applied within the EVT range and at a ratj if;Q 40 lbs./sq 0 0.0 Or • . . . . .0000. One or more plies of Ruberoid'Mop Smooth,Ruberoid'Mop.Granule, RoofMatch'SBS Modified Granular,Ruberoid'Mop 170 FR�4Zubaroid'Me •� 0""0 Plus Granule,Ruberoid'20,Ruberoid'30,Ruberoid'EnergyCap-30 FR SW • Membrane,Ruberoid'30 FR or Ruberoid'Mop FR adhered in MatrixTM 102 SBS Membrane Adhesive at an application rate of 1-2 gal./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq.and 300 lbs./sq.respectively in a flood coat of Approved as halt at 60 lbs./sq. 2. 11_GAFGLAS Mineral Surfaced Cap Sheet,Tri-Ply'Mineral Surfaced Cap Sheet or GAFGLAS'EnergyCap—BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. 3. Topcoat'Membrane,Topcoat'MB Plus(to be used as a primer with Topcoat' Membrane)or Topcoat'Surface Seal SB applied at 1 to 1.5 gal./sq. Maximum Design Pressure: See Fastening Options NOA No.: 14-1030.02 MIAMI•DADE C2UtMM Expiration Date: 11/06/18 �ffnaztlApproval Date: 11/05/15 Page 27 of 30 WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS®Ply 4 and GAFGLAS®F1exPly'6 when used as a mechanically fastened base or anchor sheet. 2. Minimum V4"DensDeck®Roof Board or%s"Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance;refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliancav�nM Product Control Approval guidelines. All other layers shall be adhered in a full of •• PP y �?4PPlig .' approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,oruwb-jnicall�.. ....;* attached using the fastening pattern of the top layer 9 0 0:0 0 . . 9 3. All standard panel sizes are acceptable for mechanical attachment. When applie.&inva$prove�d• :0006: asphalt,panel size shall be 4'x 4'maximum. 0000 •• •• ••••• 4. An overlay and/or recovery board insulation panel is required on all applications owe?hosed oell foam insulations when the base sheet is fully mopped.If no recovery board is u*end t�abase sheet shall be applied using spot mopping with approved asphalt, 12"diameter circled 24"d.c.;orstrip. .. ; mopped 8"ribbons in three rows,one at each side lap and one down the center of the sheet a:foVAfg a continuous area of ventilation. Encircling of the strips is not acceptable. A 6'rbreal;shall be- •0 :*Soo: placed every 12'in each ribbon to allow cross ventilation. Asphalt application of either systemoshall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested,are below 275 lbf.insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,prepared,signed and sealed by a Florida Registered Engineer,Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117.Calculations prepared,signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-1030.02 MIAMaDADE COUNTY Expiration Date: 11/06/18 • • Approval Date: 11/05/15 Page 30 of 30 ONLINE CERTIFICATIONS DIRECTORY TGFUA1306 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems GAF MATERIALS CORP R1306 •••••• • • 0000 0000•• 1361 ALPS RD • • • • WAYNE, N3 07470 USA • • • • 0000•• •• •• 0000•• "Ruberoid@ 20" or"Ruberoid@ 20 HT" or"Ruberoid@ Modified Base Sheet" may be utilized as an altemate'tl!l"tV G2 base stilets in anyp l•• the following Classifications. •••• • • • • 1/2-in. thick(minimum) gypsum board or 1/4-in. thick(min) G-P Gypsum Corp. "DensDeck @ Roofboard," "Derr'sbeck Prime4•Roolboard"or;•'• "DensDeck DuraGuardlm Roofboard" may be used in any existing noncombustible deck Classification. When I ti:1s'Qone,ti rMVng rooPIP4•• system is acceptable for use over combustible(15/32-in. thick minimum) roof decks. However, the butt joinUs iiqthe gypsum board and Gv%o*a Gypsum Corp. "DensDeck @ Roofboard," "DensDeck Prime@ Roofboard" or"DensDeck DuraGuardT1" Roofbpwo".11 a to offset is minimum of�• In. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below tte oserVaymentboar. ••• • 0000•• Multiple plies of"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"Tri-Ply® Ply 6" may be adhered to G-P Gypsuns Cor"DensDeck @ Roof bo wd ••,' o "DensDeck Prime® Roofboard" or"DensDeck DuraGuardl Roofboard" in hot roofing asphalt. •• . 0000 • • "EnergyGuard Ultra" is an acceptable alternate to"EnergyGuard" in any applicable Classification. " ' "GAF Stratavent@ EliminatorTM Venting Base Sheet(Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. "GAFGLAS@ Perlite Insulation" may be utilized as a cover board over"EverGuard" insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or urethane insulation adhesive. Polystyrene referenced in any of the following Classfications include"EnergyGuard EPS Insulation". References to glass fiber insulation include"EnergyGuard Fiberglass Insulation". ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet("GAFGLAS@ #75 Base Sheet" or"Tri-Ply@ #75 Base Sheet", or"GAFGLAS@ #80 ULTIMA") is a suitable alternate for Type G1 asphalt glass fiber ply sheet("GAFGLAS@ Ply 4" or"Tri-Ply®Ply 4", or"GAFGLAS@ Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet"GAF Stratavent@ EliminatorT"Venting Base Sheet(Perforated)" or"GAF Stratavent@ Eliminators"'Venting Base Sheet(Mailable)." Perforated to be loose laid or mopped and nailable to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet("GAFGLAS@#75 Base Sheet" or"Tri-Ply® #75 Base Sheet" or"GAFGLAS@ #80 ULTIMA" or"GAF Stratavent@ Eliminators"' Venting Base Sheet(Nailable)" may be substituted for Type G1 asphalt glass fiber ply sheet("GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ Ply 6") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise Indicated, all insulations may be hot mopped or mechanically fastened. "GAFGLAS@ Flashing" or"Ruberoid@" may be used for Flashing in any of the Class A, B or C systems listed below. When"perlite" is referenced, this includes"GAFTEMP PERMALITE@" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C- 15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely effect the rating. The use of 1/2-in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4-in. thick perlite board and deck with rosin paper(perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuard RA" or"Tapered EnergyGuard RA" or"EnergyGuard Composite RA" may be substituted for any Atlas polyisocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following"Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS@ #80 Premium Base Sheet" may be used in any of the following systems. "GAFGLAS@ Flex Ply 6" and"Tri-Ply@ Ultra-Flexible Ply 6" are suitable alternates to"GAFGLAS@ Ply 6". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the"Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with"Fireshield MB" at 21h to 3- gai/100-ft2. "Ruberoid@ Dual Smooth" may be used as an alternate to"Ruberoid@ Mop Smooth"or"Ruberoid@ 20" or"Ruberoid@ 20 HT" "Ruberoid@ Mop Smooth 1.5" may be used as an alternate to"Ruberoid@ Mop Smooth" Class A,B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. 9999 "Ruberoid@ Heat Weld" SBS roofing membrane may be used in lieu of"Ruberoid@ Mop" SBS products in any applicable Classification. • • 9999 9999•• Class A •• • • • • 900.9• •• •• 9999•• • 1. Deck: C-15/32 Incline: 3 .000.0 • 0 � •9009• Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polylsocyanura%ectr'ftthane qP' • • perlite/polyisocyanurate composite or periite/urethane composite or wood fiber/polyisocyanurate com1§80W or phenolic, awl thickeems• Ply Sheet:—Three or more plies Type G1 or"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS&QI#A, hot rnppped, 00;00' • • •9900• Surfacing:—Gravel. .• •• • ...... • • 2. Deck: C-15/32 Incline: Z • • • • •00.9• Insulation(Optional).—One or more layers per ite or wood fiber or glass fiber or polyisocyanurate or urethane or'••9 • 0 perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate cod w!1te or phenol"pny thlcITW.• Ply Sheet:—Three or more plies Type G1 or"GAFGLAS@ Pty 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ Ply 6". 0 0 • Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet" or"Tri-Ply@ Mineral Surfaced Cap Sheet''or''GAFGLAS@ EnergyCap'"" "" BUR Mineral Surfaced Cap Sheet." 3. Deck: NC Incline: 2 Insulation(Optional):—One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane composite, wood fiber/polylsocyanurate composite, phenolic, 2-in. maximum. Ply Sheet:—Two or more plies Type G1"GAFGLAS@ Ply 4", "Tri-Ply@ Ply 4" or"GAFGLAS@ Ply 6". Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet" or"Tri-Ply@ Mineral Surfaced Cap Sheet" or"GAFGLAS@ EnergyCap'"' BUR Mineral Surfaced Cap Sheet." 4. Deck:C-15/32 Incline: 1 SOp Sheet(Optional):— Red rosin paper, nailed to deck. Insulation(optional):—Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc "OlyBond Fastening System" or any UL Classified insulation adhesive. Base Sheet:—One ply Type G2"GAFGLAS@#75 Base Sheet" or"Tri-Ply@ #75 Base Sheet" (may be nailed). Ply Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4"or"Tri-Ply@ Ply 4" or GAFGLAS@ Ply 6". Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet"or"Tri-Ply@ Mineral Surfaced Cap Sheet" or"GAFGLAS@ EnergyCap" BUR Mineral Surfaced Cap Sheet." Surfacing(optional):—"TOPCOAT@ EnergyCote—" applied at a rate of 2-gal/100-ft2. S. Deck: NC Incline: 3 Base Sheet:—One ply Type G2"GAFGLAS@ #75 Base Sheet" or"Tri-Ply@ #75 Base Sheet". Ply Sheet:—One or more plies Type GI"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ Ply 6". Cap Sheet:—One ply Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet" or"Tri-Ply® Mineral Surfaced Cap Sheet" or"GAFGLAS@ EnergyCapm BUR Mineral Surfaced Cap Sheet." 6. Deck: C-15/32 Incline:2 Insulation:—One or more layers perlite, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane composite, phenolic, 1 in. minimum (offset a minimum of 6-in. from plywood deck joints). Base Sheet:—One or more plies Type G1 or Type G2 or Type G3. Membrane:—One or more plies"Ruberoid@ Torch Smooth" or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop Smooth" or"Ruberoid@ Mop Smooth 1.5" or"Ruberoid@ Mop Smooth Plus"or"Ruberoid@ Mop Granule" or "Ruberoid@ Mop Plus Granule" or"ROOFMatch"" SBS Modified Granular" or"Tri-Ply@ SBS Modified Bitumen Membrane" or "ROOFMatchm APP Modified Granular" or"Tri-Ply@ TP-4G" or"Tri-Ply®TP-4" or"Ruberoid@ Dual Smooth". Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet" or"Tri-Ply@ Mineral Surfaced Cap Sheet"or"GAFGLAS@ EnergyCap'" BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. 7. Deck: C-15/32 Incline: 2 Insulation(Optional):—One or more layers periite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet:—Two or more plies Type G2 or Type G3. Ply Sheet(Optional):—One or more plies Type G1. Membrane:—One or more plies"Ruberoid@ Torch Smooth"or"Ruberoid@ Torch Granule" or"Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop Smooth" or"Ruberoid@ Mop Smooth 1.5" or"Ruberoid@ Mop Smooth Plus" or"Ruberoid@ Mop Granule" or "Ruberoid@ Mop Plus Granule" or"ROOFMatchTM SBS Modified Granular" or"Tri-Pty@ SBS Modified Bitumen Membrane" or "ROOFMatchm APP Modified Granular" or"Tri-PIyO TP-4G" or"Tri-Ply@ TP-4" or"Ruberoid@ Dual Smooth". Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet" or"Tri-Ply@ Mineral Surfaced Cap Sheet" or"GAFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. 8. Deck: NC Incline: 2 Insulation(Optional):—Pedite or glass fiber or polyisocyanurate or wood fiber or mechanically fastened, any thickness. Base Sheet:—One or more plies Type G2, "GAFGLAS@#75 Base Sheet" or"Tri-Ply@ #75 Base Sheet". Ply Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4"or"GAFGLASO Ply 6". Cap Sheet:—Type G3"GAFGLAS@ Mineral Surfaced Cap Sheet" or"Tri-Ply® Mineral Surfaced Cap Sheet" or GAFGLAS@ EnergyCapm BUR Mineral Surfaced Cap Sheet"fully adhered with hot roofing asphalt. Surfacing:— "Fireshield MB" applied at 2112 to 3.0-gal./100-ft2. •••••0 9. Deck:C-15/32 Incline: 1 • ••• i • • •• 0..*.: • Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate *so*** o •••••• perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate coiWslVor phenolic?any thick:%spi�e Ply Sheet:—Three or more plies Type G1"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ rwv • • • • Cap Sheet:—"GASFGL.AS& EnergyCap' BUR Mineral Surfaced Cap Sheet". ••••• ••�00 *0000 •••••• • • ••••• 10. Deck: NC Incline: 1 • • •••••• •• •• • •••••• • Insulation(Optional):—One or more layers perite or wood fiber or glass fiber or polyisocyanura=rld;dr'rthane or • • perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate cornposite•or phenolic,2-in. ••••:• •••••• maximum. • • . � � Ply Sheet:—Two or more plies Type G1"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ Ply r_ • •••••• Cap Sheet:— "GASFGLAS@ EnergyCap•" BUR Mineral Surfaced Cap Sheet". • ••'i•• 11. Deck: NC Incline: 2 Base Sheet:—One ply Type G2"GAFGLAS@ #75 Base Sheet" or"Tri-Ply@ #75 Base Sheet". Ply Sheet:—One or more plies Type G1"GAFGLAS@ Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ Ply 6". Cap Sheet:—"GASFGLASO EnergyCap"" BUR Mineral Surfaced Cap Sheet". 12. Deck:C-15/32 Incline: 1 Insulation:—One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or phenolic, 1-in. minimum (insulation joints offset a minimum of 6-in. from plywood deck joints). Base Sheet:—One or more plies Type G1"GAFGLASO Ply 4" or"Tri-Ply@ Ply 4" or"GAFGLAS@ Ply 6"or Type G2"GAFGLASO #75 Base Sheet" or"Tri-Ply@ #75 Base Sheet"or Type G3"GAFGLASO Mineral Surfaced Cap Sheet" or"Tri-Ply@ Mineral Surfaced Cap Sheet". Membrane:—One or more plies"Ruberoid@ Torch Smooth" or"Ruberoid@ Torch Granule" or"Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop Smooth" or"Ruberoid@ Mop Smooth 1.5" or"Ruberold@ Mop Smooth Plus"or"Ruberoid@ Mop Granule" or "Ruberoid@ Mop Plus Granule" or"ROOFMatch'" SBS Modified Granular" or"Tri-Ply SBS Modified Bitumen Membrane" or "ROOFMatch—APP Modified Granular" or"Tri-Ply@ TP-4G" or"Tri-Ply(g)TP-4" or"Ruberoid&Dual Smooth." Cap Sheet:—"GASFGLAS& EnergyCapm BUR Mineral Surfaced Cap Sheet". 13. Deck: C-15/32 Incline: 1 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet:—Two or more plies Type G2"GAFGLAS@ #75 Base Sheet", "Tri-Ply@ #75 Base Sheet", or Type G3"GAFGLASO Mineral Surfaced Cap Sheet" or"Tri-Ply@ Mineral Surfaced Cap Sheet". Ply Sheet(Optional):—One or more plies Type G1. Membrane:—One or more plies"Ruberoid@ Torch Smooth" or"Ruberoid@ Torch Granule"or"Ruberoid@ Torch Granule Plus" or "Ruberoid@ Mop Smooth" or"Ruberoid@ Mop Smooth 1.5" or"Ruberoid@ Mop Smooth Plus"or"Ruberoid@ Mop Granule" or "Ruberoid@ Mop Plus Granule" or"ROOFMatch'" SBS Modified Granular" or"Tri-Ply®SBS Modified Bitumen Membrane" or "ROOFMatch'"APP Modified Granular"or"Tri-Ply@ TP-4G" or"Tri-Ply@ TP-4" or"Ruberoid@ Dual Smooth". Cap Sheet:— "GASFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet". 14. Deck: C-15/32 Incline:2 Insulation(Optional):—One or more layers perlite or wood fiber or glass fiber or polyisocyanurate periite/polyisocyanurate composite or wood fiber/polyisocyanurate composite any thickness mechanically or adhered with hot roofing asphalt. Base Sheet:—One ply"GAFGLASO Stratavent Eliminator Venting Base Sheet" or Type G2 fully adhered with hot roofing asphalt Ply Sheet:—Two or more plies Type G1 or"Ruberoid@ Mop Smooth" or"Ruberoid@ Mop Smooth 1.5" or"Ruberoid@ Mop Smooth Plus" or"Ruberoid& 20" or"Ruberoid@ 20 HT" fully adhered with hot roofing asphalt Membrane:—"GAFGLAS@ Mineral Surfaced Cap Sheet" or"GAFGLAS@ EnergyCap'" BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt 15. Deck: C-15/32 Incline: 1 •5H �� Miami Shores Village loan Building Department 10050 N.E.2nd Avenue RMiami Shores, Florida 33138 �lorlDp' Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION •.ir..• ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE."' 0000: BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES •••;•• ••••• •••• • ...... • PERSUANT TO SECTION 553.844 F.S. ••••• .... .. .. ..... To: Miami Shores Village Building Department Dat;:Gl15 :'•"• ....�. 10050 NE 2nd Ave :•':': •. . . . . ...... Miami Shores, Fl 33138 •••••• Re: Owner's Name: JAMES&CHRISTA KORRAY •• . • Property Address: 1260 NE 99 ST Miami Shores, FL 33138-2643 Roofing Permit Number: Dear Building Official: I C b f` SIP certify that I am not required to retrofit the roof to wall connections of my building because: a The just valuation for the structure for purpose of ad valorem taxation is less than$300,000.00. Please attach proof of ad valorem taxation. ❑The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions of 19 edition of the South Florida Building Code(1994 SFBC) X Signature Print Name State of Florida County of Dade The undersigned,being the first duly swom,deposes and says that he/ is the owner for the above property mentioned. r Sworn to and subscribed before me this t—d day of 06 a Notary Public State of Florida Frank Milohnich Notary Public, Sate of Florida at Large My Commission FF 089801 Expires 02/04/2018 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a budding application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 512112009 3/29/2016 Property Search Application-Miami-Dade County OFFICE OF THE PROPERTY APPRAISER Summary Report Generated On:3/29/2016 Property Information Folio: 11-3205-009-0160 Property Address: 1260 NE 99 ST ow Miami Shores,FL 33138-2643 Owner JAMES&CHRISTA KORRAY Mailing Address 1260 NE 99 ST NE ' 91H ST� MIAMI SHORES,FL 33138-2643 Primary Zone 1400 SGL FAMILY-3001-3250 SQ w • Primary Land Use 0101 RESIDENTIAL-SINGLE ' • FAMILY: 1 UNIT Beds/Baths I Half 3/2/0 • • Floors 1 Living Units 1 • � ' Actual Area 2,757 Sq.Ft Living Area 2,232 Sq.Ft hY Adjusted Area 2,494 Sq.Ft Lot Size 8,175 Sq.Ft Taxable Value Information Year Built 1951 2015 2014 2013 County Assessment Information Exemption Value $50,000 $50,000 $50,000 Year 2015 2014 2013 Taxable Value $125,990 $124,594 $122,014 Land Value $249,652 $220,401 $148,975 School Board Building Value $138,866 $135,275 $135,275 Exemption Value $25,000 $25,000 $25,000 XF Value $9,286 $9,286 $9,286 Taxable Value $150,990 $149,594 $147,014 Market Value $397,804 $364,962 $293,536 City Assessed Value $175,990 $174,594 $172,014 Exemption Value $50,000 $50,000 $50,000 Taxable Value $125,990 $124,594 $122,014 Benefits Information Regional Benefit Type 2015 2014 2013 Exemption Value 1 $50,000 $50,000 $50,000 Save Our Homes Assessment $221,814 $190,368 $121,522 Taxable Value $125,990 $124,594 $122,014 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Sales Information Second Homestead Exemption $25,000 $25,000 $25,000 OR Note:Not all benefits area applicable to all Taxable Values i.e.County,School Previous pp � Sale Price Book- Qualification Description Board,City,Regional). Page 04/01/1995 $132,000 16767- Sales which are qualified Short Legal Description 2861 EARLETON SHORES PB 43-80 02/01/1995 $0 16681- Sales which are disqualified as a result of W25FT LOT 3&E50FT LOT 4 2769 examination of the deed BLK 2 13593- LOT SIZE 75.000 X 109 02/01/1988 $138,800 521 Sales which are qualified OR 16767-2861 0495 1 07/01/1980 $120,000 10822 Sales which are qualified 1812 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp Version: