RF-17-248 Permit No, RF-1-17-248
Miami Shores VillagePermit Type:Roof
10050 N.E.2nd Avenue NE Pn Work 00 Classr'frcation:Repair Roof
Miami Shores,FL 33138-0000 Permit Status:APPROVED
Phone: (305)795-2204
F�0 11)
Issue Date: 1/31/2017 Expiration: 07/30/2017
Project Address Parcel Number Applicant
136 NE 110 Street 1121360040430
Miami Shores, FL 33161-7046 Block: Lot: VICTOR&MARILOU LAYUG
Owner Information Address Phone Cell
VICTOR&MARILOU LAYUG 136 NE 110 Street
MIAMI SHORES FL 33161-7046
136 NE 110 Street
MIAMI SHORES FL 33161-7046
Contractor(s) Phone Cell Phone Valuation: $ 980.00
L CORTES CONSTRUCTION SERVICE (305)454-3894 Total Sq Feet: 40
Type of Work:Repair Available Inspections:
Additional Info:REPAIR ROOF SECTION OF 4X8 Inspection Type:
Classification:Residential Roof Repair
Scanning:3 Final Roof
Review Roof
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $0.60
DBPR Fee InvOICe# RF-1-17-62778
$2.00 01/31/2017 Check* 1942 $ 114.60 $0.00
DCA Fee $2.00
Education Surcharge $0.20
Permit Fee-Repairs $100.00
Scanning Fee $9.00
Technology Fee $0.80
Total: $114.60
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRIPAL,PLUMBING,MECHA C WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
O RSA I VI . I cert; that I t information is accurate and that all work will be done in compliance with all applicable laws regulating
nstructi a zoning: Fut mord, o' e the a ve-named contractor to do the work stated.
January 31, 2017
Authorized Sig ature:Owner / Applicant / Contractor / Agent Date
Building Department Copy
January 31, 2017 1
Miami Shores Village CF"TVFD
Building Department AN 31 2017
10050 N.E.2nd Avenue Miami Shores Florida 33138 BY:
Tel:(305)795-2204 Fax:(305)756-8972
INSPECTION LINE PHONE NUMBER:(305)762-4949 s�
FBC 20 iu Q'
BUILDING Master Permit No.
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC ® ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: /36 No //O ST
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: I I-9113(o - 00 Lk- O`(3 a Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FIFE:
OWNER:Name(Fee Simple Titleholder): LL G�o 2 L A�I LLQ Phone#:
Address: 13 (P N E- 1 X 0 S�
City: K I Q M % `) " 0 0.eb I State: Zip: 3 3 1 b 1
Tenant/Lessee Name: Phone#:
Email: \
CONTRACTOR:Company Name: Cp(Z�C' $ �vz S V` Lk-%-Ayoy x SE 0.%J Phone#: '-kS4 - 3$Qy
Address: I 6 N W Ct W b."y
City: State: zip: 33 o15
Qualifier Name: p Cy C, O C+ S Phone#: 3 6 5- y 5y - 3 SA Ll
State Certification or Registration#: C C C 1 3 3 0 q-Q 6 Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: nn City: State: Zip:
Value of Work for this Permit:$ "1 b C) O Square/Linear Footage of Work: 14 o 5!j FT
Type of Work: ❑ AA-dddiit�ion ❑ Alteration ❑ New Repair/Replace ❑ Demolition
Description of Work: l'1 G p hs't (Z --V`t0 0 c EAl t o w► 0
Specify color of color thru tile: //��
Submittal Fee$ Permit Fee$ 100 CCF$ . 60 CO/CC$
Scanning Fee$ — Radon Fee$ 2 DBPR$ Notary$
Technology Fee$ Q W _Train ing/Education Fee$ 0 UJ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$ I�
(Revised02/24/2014)
f 1 7
Bonding Company's Name(if applicable)
Bonding Company's Address _
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occu (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved nd a reinsp ction fee will be charged.
Signature Signatur
OWNER or GENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of "--1Arjua," 120 17 by ka day of 20 1 by
�i o r 1a09 ,who is personally known to � -�I �C� who is personally known to
me or who has produced as me or who has produced 1�7 L vl�l `-- as
identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign:<f� �� Sign: —W
Print: A�--rrlbza . ,,,, Print:
4P M1 ION 1 '~ ''� MY CO=SFF241196
Seal:
4P M1
MVCOMMISS 2017 Seal:
EXPIRES:Ba $emus • EXPBMded
rA�EOF F��
APPROVED BY ' ? Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
Miami Shores illage
• J �' Building Department
10050 N.E.2nd Avenue
11D Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date: /-/gla/
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: o L N u
Property Address:-_I 3 0 P F
Roofing Permit Number:
Dear Building Official:
I t �o V certify that I am not required to retrofit the roof to wall connections of my
building because:
The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the S t Florida ilding Code(1994 SFBC)
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this /02 day of'-JAN=I — I V+o-mnoeA
ao ••• o* MY COMMISSION#EE 867709
* EXPIRES.January 23,2017
Notary Public, Sate of Florida at Large 4 .. �sz�-�'Troiike' eonde°Th"B°a+>�N ryS���g
When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation,
Revised on 5/21/2009
1/12/2017 Property Search Application-Miami-Dade County
"RT" APP"RAIN""Eirl'
OFF10"I OF THE PUSEa
Summary Report
Generated On: 1/12/2017
Property Information
Folio: 11-2136-004-0430 f
Property Address: 136 NE 110 ST
Miami Shores,FL 33161-7046
Owner MARILOU A LAYUG&H VICTOR
Mailing Address
136 NE 110 ST
MIAMI,FL 33161-7046
Primary Zone 1000 SGL FAMILY-2101-2300 SQ , -
Primary Land Use 0101 RESIDENTIAL-SINGLE T_'
;
FAMILY: 1 UNIT r
Beds/Baths/Half 4/2/0
Floors 1
�r
Living Units 1 7r'
Actual Area 2,735 Sq.Ft
Living Area 1,673 Sq.Ft 2 h gra
Adjusted Area 2,213 Sq.Ft
Lot Size 9,300 Sq.Ft Taxable Value Information
Year Built 1941 2016 2015 2014
County
Assessment Information
Exemption Value 1 $50,000 $50,000 $50,000
Year 2016 2015 2014 Taxable Value $95,402 $94,392 $93,247
Land Value $199,874 $164,822 $155,872
School Board
Building Value $154,025 $154,025 $150,041 Exemption Value 1 $25,000 $25,000 $25,000
XF Value $18,110 $12,818 $12,836 Taxable Value $120,402 $119,392 $118,247
Market Value $372,009 $331,665 $318,749 City
Assessed Value 1 $145,402 $144,392 $143,247 Exemption Value 1 $50,000 $50,000 $50,000
Benefits Information Taxable Value 1 $95,402 $94,392 $93,247
Regional
Benefit Type 2016 2015 2014 Exemption Value $50,000 $50,000 $50,000
Save Our Homes Assessment
Cap Reduction $226,607 $187,273 $175,502 Taxable Value $95,402 $94,392 $93,247
Homestead Exemption $25,000 $25,000 $25,000 Sales Information
Second Homestead Exemption $25,0001 $25,0001 $25,000 OR
Note:Not all benefits area applicable to all Taxable Values i.e.County,School Previous
pp � � Sale Price Book- Qualification Description
Board,City,Regional). Page
12/01/2000 $0 19416- Sales which are disqualified as a result of
Short Legal Description 4549 examination of the deed
COLLEGE HEIGHTS PB 42-8 16529
LOT 12 BLK 2 09/01/1994 $107,500 Sales which are qualified
4217
LOT SIZE 75.000 X 124 16306- Sales which are disqualified as a result of
OR 19416-4549 12 2000 4 03/01/1994 $0 4715 examination of the deed
06/01/19921$118,0001 15572- Sales which are qualified
0633
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property
Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
SµOR�y.
� M
ORSDA
SECTION 1524
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit,and to explain to the owner the content of the section.The provisions of Section 84402
govern the minimum requirements and standards of the industry for roofing system installations.Additionally, the
following items should be addressed as part of the agreement between the owner ant the contractor.The owner's
initial in the designated space indicates that the item has been explained.
2• Renaiiing wood decks:When replacing roofing,the existing wood roof deck may have to
be r nailed in accordance with the current provisions of Section R4403. (The roof deck is usually
co sealed prior to removing the existing roof system).
4• Exposed Ceiling: Exposed,open beam ceilings are where the underside of the roof decking
c e viewed from below.The owner may wish to maintain the architectural appearance;therefore,
roofing nail penetration of the underside of the decking may not be acceptable.This provides the option of
maintaining the appearance.
6. — Overflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is
n overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
dischar overflow sc ers(wall outlets)are not provided. It may be necessary to install overflow
scupp s in accordance ith the requirements of Sections R4402, R4403 and R4413,
ner/A 's Signature Date Contractor Signature Date
-4Z4 &I C �"�2 ie
Property Address Permit Number
Revised on 7/9/2009 LD;07/01/2015;
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition (2014) r
(�
ih-Velocity Hurricane Zone Uniform Permit Applicatio7BY
N 3 1 2017 1
LJ 1
Section A(Genera!Information) 1
1
Mat r i f Process No. 1
Contractor's Name__L C O(L � ( o N g ►(Luh` n kj tJ i ce- L L C 1
i
Job Address
1
ROOF CATEGORY 1
❑ Low Slope ❑ Mechanically Fastened Tile E Mortar/Adhesive Set Tiles 1
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes 1
❑ Prescriptive BUR-RAS 150 1
ROOF TYPE 1
❑ New roof ■ Repair ❑ Maintenance ❑ Reroofing ❑ Recovering 1
ROOF SYSTEM INFORMATION 1
Low Slope Roof Area(SF) Is L01 Steep Sloped Roof AREA(SSF)— !L)` Total(SF)__.,4e 1
1
Section B(Roof Plan) 1
Sketch Roof Plan. Illustrate all levels and sections, roof drains,scuppers,overflow scuppers and overflow drains. Include dimen-
sions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. 1
1
> i 37 1
- rn D1
3 ° 0
1
z �
N � >
� D
r
z 1
Cl) M
co - 1
Z
rr o =
D 1
t
J m � ! 1
D oEli 1
z
o "" -+
v' V
• • • • • 1
.. .. 1
............ 1
_ 1
• 1
... . . ... . .
... . . . . ... . .
FLORIDA BUILDING CODE—BUILDING,5th EtZITi01V(20t�t!;0; ; 0 15.37
1 , Copyright to,or lie rRed bA 1CCALLIU(MTS RESERV�E%rxessed by Eliezer Palacio on!un 8,201510:32:12 AM pursuant to License
�
Agreement.No furljti jcpry�uctiory aunzed� .
Y
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition(2014)
High-Velocity Hurricane Zone Uniform Permit Application Form 1
1
Section D(Steep Sloped Roof System) 1
Roof System Manufacturer: A N U S
Notice of Acceptance Number._ N — o b o s — 03 1
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): I
P1: P1: P1:
1
I
1
Deck Type: _.....
r
_ Type Underlayment: I
Roo Slope:
lope.
_ 12 -.
I— Insulation:
Fre Barrier:
IVIA
1
Ridge V, .1 ? Fastener Type&Spacing: �• �� � r
i/ T/N AQ r
Adhesive Type: AVIA 1
1
Type Cap Sheet: 1 1
YS1,� Tu. PMS _J 1
Mean Roof Height: /�� Roof Covering: MpTcti'"'S Ex1sTt"'�gt �+a� 1
Type&Size Drip 3X3t 261J 1
Edge: !
�t r
1 I
l xi fr 1.,'tvi, r,
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... ... . ... .
. .
. .. .. . .. . .
... . . ... . .
... . . . . ... . .
FLORIDA BUILDING CODE--BUILDING,5th EaiTl( f(20=4);•; ; ; ; 15.39
r r 1 Copyright to,or liceed b:,10C N IMiTS 1 ESE �VD1 i ecessed by Eliezer Palacio on Jun g,2015 10:32:12 AM pursuant to License
Agreement.No fi�herieprp�uutoys sut}1Pnze j•• • •
i
i
M I.A.M.
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy
Polyglass USA Inc.
1111 W.Newport Center Drive
Deerfield Beach,FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site,at*thL-T(We;t Qf Jhe Bpildiag Official.
•• • • • • •
This NOA renews and revises NOA No.14-07
00
#0 ••d� • s� is of• es•l through 8.
.�. $� �Rn � . i'.aga.
The submitted documentation was reviewed by Gaspar J Rodriguez.
. ... .. . ... .
NOA No.: 15-0410.04
ADE . NTYW ••• ••• Expiration Date: 09/13/21
• Approval Date: 08/11/16
• Page 1 of 8
. .. .. . . . .. ..
... . . . ... . .
ROOFING COMPONENT APPROVAL
Cate2orv: Roofing
Sub-Category: Underlayment
Material: SBS ,APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick IR-Xe 65'x 3'33/8" ASTM D 1970 A fine granular/sand top surface self-adhering,APP
Manufacturing Or 65'x 3' polymer modified,fiberglass reinforced,bituminous
Location#1  60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice&rain shield.
Polystick Dual Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location#2 metal roofing and roof tile underlayment.
Polystick Tile Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Location 42 roofing and roof tile underlayment.
Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhering,polyester reinforced
Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile
Location#1 &42 underlayment.
Polystick TU P 32'10" x 3'3_3/81, TAS 103 and A rubberized asphalt waterproofing membrane, glass-
Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced,with a granular surface
Location#2 designed for use as a tile roof underlayment.
Polystick TU Plus 65'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
(Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing roofing and roof tile underlayment.
Location#1 
Polystick MTS 65'8"x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus 65'8"x 3'33/8" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane, glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G 32'10" x 3'3-%" TAS jpand Polxest er reinforced, SBS modified bitumen membrane
Manufacturing I:STM 11 ft; ;vsitlj a apded back face and a granule top surface. For
Location#2 0• *j j j :ule 3A loot the underlayment systems.
.. •00 •• • • • ••
... ... . ... .
. .. .. . .. . .
... . . ... . .
NOA No.: 15-0410.04
Expiration Date: 09/13/21
Approval Date: 08/11/16
. . . . . . . . . .
Page 2 of 8
. .. .. . . . .. ..
... . . . ... . .
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED
Test Auncy Test Identifier Test Name/Report Date
Trinity ERD P10870.09.08-R1 TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798 &G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798 &G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798 &D1970 10/19/11
P40390.08.12-2 ASTM D 1623 08/07/12
P37590.07.13-1 ASTM D6164 07/02/13
P45270.05.14 TAS 103, TAS 110&ASTM D1623 05/12/14
P46520.10.14 ASTM D1623 10/03/14
P44360.10.14 TAS 103 &TAS 110 10/07/14
P43290.10.14 ASTM D 1970&TAS 110 10/17/14
PLYG-SC 10130.06.16-3 TAS 103 &TAS 110 06/27/16
PLYG-10130.06.16-1 ASTM D1970&TAS 110 06/27/16
PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-089-02-01 TAS 103/ASTM D4798 &G155 07/06/09 It
Momentum Technologies,Inc. JX20117A TAS 103/ASTM D4798&G155 04/01/08
RX14E8A TAS 103/ASTM D4798&G155 11/09/09
DX231)813 TAS 103/ASTM D4798&G155 02/18/10
DX23D8A TAS 103/ASTM D4798 &G155 02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
.. ... . . . . . ..
1.This Notice of Acceptance. •
2.An other documents required b the Buil • ••cia •r a •li•a•le •ttildin code in order to properly evaluate the
Y q Y ding Q� � l0 >?P C b .l2 g P P Y
installation of this materials.
. ... ... . ... .
. .. .. . .. . .
... . . ... . .
NOA No.: 15-0410.04
®HMDE C{7€ TY
IIIA , ••• • • • • ••• • • Expiration Date: 09/13/21
• • • • • • • Approval Date: 08/11/16
• Page 3 of 8
. .. .. . . . .. ..
... . . . ... . .
INSTALLATION PROCEDURES:
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick
TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus, self-adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G,hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32"plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type I1 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self-adhered with minimum 3" horizontal laps and minimum 6"vertical
laps.
Membrane: Polystick TU Plus,self-adhered.
Surfacing: See General Limitations Below.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... ... . ... .
. .. .. . .. . .
... . . ... . .
NOA No.: 15-0410.04
MUMNaME ••• ••• Expiration Date: 09/13/21
IIII��� ' • % Approval Date: 08/11/16
. . . . . . . . . .
• •• •• • • • •• ••
Page 4of 8
... . . . ... . .
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and
sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3-%2" and end laps
shall be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of
the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building
code.
4. When applying the membrane in the valley, start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications,center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention
to lap areas.
7. Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof the systems.
Polystick TU Max may be used in non-structural metal roofing and roof the systems.
Elastotlex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe, Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below:after application. Polxgl a ss reserves the right to revise or alter product
exposure times; not to exceed the preceeding r:a��u�tem*,lirritations.
&p%gellibita ibn a
MTS IR-Xe Elastoflex TU TU P Tile Pro Dual Pro TU Max MTS Plus
S6 G Plus
Winter Haven,FL 180 90 :8%• •C$b . . 180: .0180 180 180 180
Hazelton,PA N/A 90 /A. 0 • Wl/A: : I1/A N/A 180 N/A
... . . ... . .
NOA No.: 15-0410.04
WNKAHHMDEC u
�'l���� � j ��• •�• Expiration Date: 09/13/21
• • Approval Date: 08/11/16
• • • Page 5 of 8
. .. .. . . . .. ..
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflex S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope
shall be as follows: (See Table Below)
Tile Profile Polystick MTS Elastoflex Polystick TU Plus,TU P, Polystick Polystick
S6 G Tile Pro,Dual Pro TU Max MTS Plus
Flat Tile Prohibited 4:12 6:12 6:12 5:12
without battens
Profiled Tile Prohibited 4:12 6:12 6:12 4:12
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required,they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure—two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles—for
all underlayments except Polystick MTS which shall be loaded onto battens.
Rooting Tiles
;6 Max. Per Stack) _ \
y
CL
t Z y%y
E5
_:..a E
�.��
CIO
mot Deck prepared with
POLkSnCKTU Plus
•• ••• 0.0
• • • • • ••
• •• • • • • ••• •
• ••• ••• • ••• •
• •• •• • •• • •
••• • • ••• • •
® NOA No.: 15-0410.04
PgAHWADE CCKJNW Expiration Date: 09/13/21
In ;•; ; ; ; Approval Date: 08/11/16
:••.: ; ; ;•••;
Page 6of 8
•.. . . . •.. . .
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU
Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G may be
used with any approved roof covering Notice of Acceptance listing Polystick IR-Xe,Polystick Dual Pro,
Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick MTS,Polystick MTS
Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe,Polystick Dual Pro, Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick
TU Plus,Polystick MTS,Polystick MTS Plus or Elastoflex S6 G are not listed, a request may be made to the
Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Section for approval provided
that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance, and fire
testing results.
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1 V metal disk as
required in Miami-Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on
the face of membrane,with the above stated nails and/or disks. The head lap membrane is to cover the area being
back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide,uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,
XtraFlex 50 Premium Modified Wet/Dry Cement,Polyglass PG500 MB Flashing Cement,applied in between
the application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments.Refer to the Polyglass Tile
Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens,as required by the tile manufacturers NOA,must be used on all projects for
pitch/slopes of 7712"or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12",precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys,or exposed
roof to wall details.
9. Repair of Polystick membranes is to beeccompliste a 1r:•apil};njVolyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Fielislttip C&pent,XtraFlex 50 Premium Modified
Wet/Dry Cement,Polyglass PG500 MB•FlashfAg(:ttnerft to tht Ata in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 incjes*Veithegdir�e�on. 61�ft Loppir should be installed in such a way so
that water will run parallel to or over tbt to§of all taps•Qf the pitch; ;
. .. .. . .. . .
•.. • .�.
NOA No.: 15-0410.04
WMAHMADE
Expiration Date: 09/13/21
••• • • • • ••. • • Approval Date: 08/11/16
i i•••i i i i i•••i Page 7 of 8
••• • • • ••• • •
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association(NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... ... . ... .
. .. .. . .. . .
... . . ... . .
NOA No.: 15-0410.04
PGAMMOME[ Expiration Date: 09/13/21
"' ' ' "' • Approval Date: 08/11/16
Page 8 of 8
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
htAAK MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economv
ICP Adhesives and Sealants,Inc.
12505 NW 44"'Street
Coral Springs,FL.33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset®AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job situ t4�requ,st of the Building Official.
This NOA revises NOA 14-0805.01 and consisis of Page e-1 I h;ot;@6*11.•
The submitted documentation was reviewed by At"Tigera. • ••
••• ••• NOA No.: 16-0315.01
■
MIAMI•DAD;COUNTY ;.. •• ;•• ;• ••• Expiration Date: 05/10/17
Approval Date:04/07/16
••• ••• Page 1 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc.as described
in this Notice of Acceptance. For the locations where the design pressure requirements,as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP
Adhesives Polyset®AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive
Polyset®AH-160
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPack® N/A Dispensing Equipment
30& 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.6 lbs./ft.3
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07% Volume Change @-40'F.,2 weeks
•• ••; �•�
160%.-Volume Change @1580F., 100%Humidity,2
Closed Cell Content AS'FM.Z 2&S6'.' 8610..'
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and a*fgMect tQ normal nwKmfacturing variation.
•• '. NOA No.: 16-0315.01
MIAMMADE COUNTY ;.. ;• ;• • • • • Expiration Date: 05/10/17
Approval Date: 04/07/16
• Page 2 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset' AH-160 shall solely be used with flat,low, &high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administralive,Codr- ..
.. ... .. . . . ..
. ... ... . ... .
' NOA No.: 16-0315.01
MIAM•DADE COuNTY ;.. ;' ;• ;•, ;• • • Expiration Date: 05/10/17
Approval Date:04/07/16
Page 3of11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
INSTALLATION:
1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset®AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120,and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and
Sealants,Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0(B).
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP
Adhesives ProPack®30& 100 dispensing equipment only.
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details'herein. Each generic tile profile requires the specific placement noted herein.
.. ... . . . . . ..
. .. . . . . ... .
. ... ... . ... .
• � NOA No.: 16-0315.01
MIAMI-DAD;COi�FjAzogm NTY ;.. ;' ;• ;• ;• ••• Expiration Date: 05/10/17
Approval Date:04/07/16
... . . . . ... . .
Page 4 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat,Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
.. ... . . . . . ..
. .. . . . . %: .
. .
.. ..: 0.: . : : ..
. ... ... . ... .
•• • • • : : : NOA No.: 16-0315.01
MIAMI•DADE COUNTY :.. :• :• ;.. ;• • • Expiration Date: 05/10/17
Approval Date:04/07/16
OV
• • �•• • Page 5 of 11
• • • • • • • • • •
••• • • • ••• • •
ADHESIVE PLACEMENT DETAIL# 1
%Athrcrughptastkc myle•n•Mhna) Flat/Low Profile Tile
{wire`r•qufrndyy
1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
_ 10�� _ `°�=� '� of the tile being set.
sow"QpfiGnm
�- '
ewac•drs. , 2. Continue in same manner. Insure approximately 17
a ° y x r (109.7 cm2)—23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
�a
Nail thrrouyhpbstk cemem Medium Profile/ Double Pan Tile
{when re�uirrd�
P,aayy „�+.eilr { 1. Starting at the eave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2fnrid.
Eatferisaptfaaai :. 2. Continue in same manner. Insure approximately 17
w f 1 (109.7 cm2)—23 (148.4 cm2) square inch adhesive
_ r{ contact with the underside of the tile.
f � ��atlosurie
i:ara Course Fascia
w thrawgh p{a+,R{r -. ra•n�ehTll•l High Profile/Single Pan Tile
an raged► •
1. Starting at the eave course,apply a minimum 2"
• i (50.8 mm)x 10"(254 mm)x 1"(25.4 mm) foam
paddy onto the underlayment positioned as shown
taia x x �� under the pan portion of the tile closest to the
a In,wade overlock of the tile being set.
8attaas � �� . 2. Continue in same manner. Insure approximately 17
(109.7 cm2)—23 (148.4 cm2) square inch adhesive
cogtact with the underside of the tile.
,s *,.www ''�.•, '"�;,``'''`��..,,,, • ••�i • • • • •
Weeeale • • • • • •
101s in• Eaw closure
DMPP
• ••• ••• • ••• •
— •• • • •• • i i NOA No.: 16-0315.01
MIAMMDADE COUNTY 000 :• :• :•• :' •.• Expiration Date: 05/10/17
Approval Date:04/07/16
••• • • • • ••• • • Page 6 of 11
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
ADHESIVE PLACEMENT DETAIL#2
ghl �i�t.m.n� ddyj*"*„hrd.i Flat/Low Profile Tile
n4uifad)� rte,,
E
'�•' " `'' W `"ry % 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
1 � strengthening rib of the tile closest to the overlock of
". yln • �,. � "- the tile being set. Insure approximately 17 (109.7 cm2)
23 (148.4 cm) square inch adhesive contact with the
M underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
Fai,a x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
'�` `� underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
.�.cie .-�� ��' being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm)- 12(77.4 cm2)square inch adhesive
contact with the underside of the tile.
Nail throughphsticomera Medium Profile/Double Pan Tile
(when r"Wiredl
\\ _,f"sdcly4bontathTile) 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm )-
' - 23 (148.4 cm2)square inch adhesive contact with the
underside of the tile.
2. At the second course,apply a minimum 2" (50.8mm)
x'^ x x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
r.—Co.,. underlayment positioned as shown under the pan
liwr4tesrrrr ¢ , portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2)- 14(90.3 cm2) square inch adhesive
contact with the underside of the tile.
• ••. gnstruoiions continued on next page)
..
.
or ... . ••• .
• • • NOA No.: 16-0315.01
QMIAMI-DALDEUNTY • • • • • • • •
e r ;• ;.. .• Expiration Date: 05/10/17
Approval Date:04/07/16
Page 7 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
Nanthrough ptssYkte P.edy►iaol hTil�a High Profile/Single Pan Tile
(whtn rayc�i►ad)
1. Starting at the eave course apply a minimum 2"(50.8
mm)x 10" (254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
~ ` pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2)—
' 21 � �r 23 (148.4 cm2)square inch adhesive contact with the
•� � I ,�, '� '�'' underside of the tile.
� „ 2. At the second course,apply a minimum 2"(50.8mm)
Ivvec4I'm ` --Fascia x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
wvoph+a40 underlayment positioned as shown under the pan
loin, 2In, taw closure portion of the tile closest to the overlock of the tile
o@ ` being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2) - 19 (122.6 cm2)square inch adhesive
contact with the underside of the tile.
.. ... . . • . . ..
••
go
• . • .
.. ... .. .• . . ..
. ••• ... . .
. •
• NOA No.: 16-0315.01
MIAMMADE COUNTY •' • • •• • • • •
•• .•• Expiration Date: 05/10/17
Approval Date:04/07/16
••• •.• Page 8 of 11
. . . . . . . . . .
. .. .. . . . .. ..
ADHESIVE PLACEMENT DETAIL#3
tit duou0 ph'Ac cement paddy(between tiles)
iw1*n required) 1. On the eave course only, apply a minimum 2" (50.8
ttattensoptional mm) x 10" (254 mm)x 1" (25.4 mm)foam paddy
{ "ble) onto the underlayment positioned as shown,under
singlepaddy , the strengthening rib for flat tile or under the pan
on top of the ,r ,�
portion of the tile for low or high profile tile closest
to the overlock of the tile being set.Leave
4 x 4 as k 4� '�-. approximately 4" (10 1.6 mm)up from the eave
si►yleWdy �}i` edge free of foam to prevent the expanded adhesive
ay"'e"t 2x4In. from blocking the weep holes. Insure
• .� approximately 17-23 int(109.7-148.4 cm2)of
toiadhesive contact with the underside of the tile
tin. Fascia
sa,PedQsute 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x V (25.4
mm) foam paddy onto the underlayment just below
Flat/Low Profile Tile the second course line positioned foam paddy
under the strengthening rib for flat tile,or under the
Mall through piast(ccesnent Single paddy under tile pan portion of the tile,closest to the underlock for
(rr}ten required)
Paddy(betweentiles) the second course tile to be installed. Insure
approximately 8-9 int(51.6-58.1 cm2)of adhesive
Battens Paddy(undertle) contact with the underside of the tile.
loptional
tdtt (Instructions continued on next page)
aX4(n.
2x4in.
�wddyon
ymefft
01n. a in.
Oil
Eave Closure
Eave Course ascia
Medium ProflieTlte
.00
•. .•. .. • . . ..
M(AM(•DADE 0 LINTY ,' ;. ' :. . :• : NOA No.: 16-0315.01
- .,. ... Expiration Date: 05/10/17
Approval Date:04/07/16
••� ���
Page 9of11
. . . . . . . . . .
. .. .. . . . .. ..
ADHESIVE PLACEMENT DETAIL#3 (CONTINUED)
Nab through plastic Single paddy under tik
(whenrequired) 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x3/4
Paddy(between tiles) (19 mm)paddy on top of the eave course tile
Battens �,t��rnt surface as shown, on top of the strengthening rib
°p`o"al for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
4 ,
4x4in. ; 9 (58.1 cm2)- 11 (71cm2) square inch adhesive
2 xain. contact with the underside of the tile at the overlap
paddy an and 7 (45.2 cm2)-9 (58.1 cm2) square inch
topof e - adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
Eare COrrse fascia
Weephole
10in. 2 in. Ene close
Drip edge
High ProflteTlle
• ; '. : : : NOA No.: 16-0315.01
MIAMI-DADE COUNTY • •• •• • •• • •
r ... • Expiration Date: 05/10/17
Approval Date:04/07/16
Page 10 of 11
. . . . . • . • . •
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel(Cap and Pan)Tile
1. Starting at the eave course,apply a minimum 2"
in contPlacenough adhesive pan tile. achieve 65 to 70 sq.in. (wSteen requtchired)
red)applications 5 0.8 mm x 10" 254 mm x 1" 25.4 mm foam
in contact with the pan tile. !when required) ( ) ( ) ( )
2)Turn covers upside down.Place adhesive in paddy onto the underlayment positioned as
tot In.from outside edge of cover tile. shown under two adjacent pan tiles. Support eave
Then install the tile.Ensure 20 to
25 sq.in.contact area. r tiles from rocking until adhesive has a chance to
Underiayment • cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
t"�' �'��'�✓ approximately 65 (419.4 cm2)—70(451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
rry r sheathing
Save dosure
(motor shown) 3. Turn covers upside down exposing the underside
weephok Fascia Board of the tile.Apply a minimum 1"(25.4 mm)x 10"
(254 mm)bead of adhesive directly on the inner
Remove top portion of the eave course cover tile.Abut tosecond tours*of edge of each side of the cover tile. Leave
pan tiles.Ensure save end of pan and cover tiles are flush at eave line. approximately 3/4" (19 mm)to 1"(25.4 mm)
Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20(129 cm2)-25 (161.3 cm2)square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner.Trim away
any cured exposed foam adhesive.Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required,2" (50.8
mm)x 4"(101.6 mm)nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
.. ••. • . a . . ..
• •• • • • • ••• .a
• ••• ••• • a•• •
• ' ' • : NOA No.: 16-0315.01
MIAMI•DADE COUNTY • a + • •• • • • •
t a •• •a •a • Expiration Date: 05/10/17
••• • . ••. • • Approval Date:04/07/16
Page 11 of 11
•a• • • • ♦ •.+ •
• • • • • • • • • •
MIAMI-DADE COUNTY
MIAMFDADE PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy
Sulacer USA,Inc.
6801 NW 77 Avenue,Suite#302
Miami,FL 33166
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Altusa"S"Clay Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire I QPPskaW W pfovided to-the user by the manufacturer or its distributors and
shall be available for inspection at the jdt site.4 t;CXeQujst;q�the•Building Official.
.. ... .. . . . ..
This renews and revises NOA No. 12-1203.07 consists of pages 1 through 7.
The submitted documentation was reviewed by Juan E. Collao,R.A.
. ... ... . ... .
NOA No.: 14-0605.03
MIAMI•DADE COUNTY Expiration Date: 08/26/19
• Approval Date: 08/28/14
• Page 1 of 7
. .. .. . . . .. ..
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Clay
Deck Type: Wood
1. SCOPE
This approves a roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.V. and
distributed by Sulacer USA, Inc., as described in Section 2 of this Notice of Acceptance. For locations where the
pressure requirements, as determined by applicable Building Code does not exceed the design pressure values
obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment
calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Altusa"S"Clay Roof Tile Length: 18.75" ASTM C 1167 High profile,one-piece, `S' shaped single roll clay
Width: 10.75" tile with a nominal 2-'/i inch headlap. For direct
Thickness: 0.46" deck nail-on,mortar set,or adhesive set
Height: 3.6" applications.
Trim Pieces Length: varies TAS 112 Accessory trim, clay roof pieces for use at hips,
Width: varies rakes, ridges and valley terminations.
varying thickness Manufactured for each tile profile.
2.1. MANUFACTURING LOCATION
1. Pimienta Cortes,Honduras
2.2. EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
American Test Lab of South RT0426.01-11 ASTM C 1167 05/07/11
Florida
American Test Lab of South RT0706.01-11 Static Uplift Testing 07/11/11
Florida TAS 101
American Test Lab of South 2397-116 ASTM C 1167 06/28/07
Florida
American Test Lab of South RT0712.02-13 ASTM C 1167 07/19/13
Florida
.. ... . . . . . ..
American Test Lab of South •,RT•0,?�4!Q -le 0 ASTM C 1167 07/29/14
Florida
American Test Lab of South . RZ0808.Q1-14 0 0 0 Aerodynamic Multiplier 08/13/14
Florida : : : : : lZestoring Moment Calculations
. .
. .. .. . .. . .
... . . ... . .
NOA No.: 14-0605.03
CMAMIMADEOUNTYExpiration Date: 08/26/19
• - •• • ••• Approval Date: 08/28/14
;�••; �•••�
Page 2of7
... . . . ... . .
The Center for Applied 94-083 Static Uplift Testing April 1994
Engineering, Inc. TAS 101 (Adhesive Set)
The Center for Applied 94-084 Static Uplift Testing May 1994
Engineering,Inc. TAS 101 (Mortar Set)
The Center for Applied 25-7200-1 Static Uplift Testing Feb. 1995
Engineering,Inc. TAS 102
(Quick-Drive Screws,Battens)
The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994
Engineering,Inc. Test#MDC-78 TAS 100
Celotex Corporation Testing MTS 520649 TAS 102(A) May 2000
PRI Asphalt Technology, Inc. CLF-003-02-01 TAS 102 October 2001
Redland Technologies 7161-03; Appendix III TAS 102 Dec. 1991
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II TAS 108 (Nail-On)
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108(Nail-On)
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108 (Mortar Set)
Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999
Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995
Walker Engineering,Inc. Evaluation Calculations 25-7094 February 1996
Walker Engineering,Inc. Evaluation Calculations 25-7496 April 1996
Walker Engineering, Inc. Evaluation Calculations 25-7584 December 1996
25-7804b-8
25-7804-4& 5
25-7848-6
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... ... . ... .
. .. .. . .. . .
... . . ... . .
NOA No.: 14-0605.03
MIAMI•DADE COUNTY Expiration Date: 08/26/19
Approval Date: 08/28/14
;.•.; ;�•�;
Page 3of7
... . . . ... . .
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami-Dade Product
Control Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20-3 of the Florida Administrative Code.
3.8 May be installed on slopes 7:12 and greater.
4. INSTALLATION
4.1 Altusa `S' Clay Roof Tile and its components shall be installed in strict compliance with Roofing
Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile Weight-W(lbf) Length-I (ft) Width-w (ft)
Altusa "S" Clay Roof Tile 6.5 1.56 0.9
Table 2: Aerod namic Multipliers - (ft)
Tile A, (ft) ), (ft)
Profile Batten Application Direct Deck Application
Altusa "S" Clay Roof Tile 0.269 0.291
Table 3: Restoring Moments due to Gravity- M9 (ft-lbf)
21': 12" 3": 12" 4": 12" 5": 12" 611: 12" 7": 12" or
greater
Batten Direct Batten Direct Batten Direct Batten Direct Batten Direct Batten Direct
Deck Deck Deck Deck Deck Deck
4.70 4.71 4.63 4.65 A.W. .4.57 . .Q. 4.46 4.30 4.34 4.16 4.21
. .. . . . . ... .
.. ... .. . . . ..
. ... ... . ... .
. .. .. . .. . .
... . . ... . .
NOA No.: 14-0605.03
MwMi•oae couNnr Expiration Date: 08/26/19
Approval Date: 08/28/14
• • Page 4 of 7
. .. .. . . . .. ..
... . . . ... . .
Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Me hanically Attached Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (Min 15/32" plywood) (Min. 19/32" plywood)
Altusa "S" 2-10d Ring Shank Nails 28.6 41.2 19.4
Clay Roof Tile
1-10d Smooth or Screw 5.1 6.8 2.8
Shank Nail
2-10d Smooth or Screw 6.9 9.2 7.3
Shank Nails
1 .#8 Screw 28.7 28.7 18.1
2 18 Screws 58.2 58.2 26.8
1-10d Smooth or Screw 23.1 23.1 19.0
Shank Nail Field Clip)
1-10d Smooth or Screw 29.3 29.3 24.0
Shank Nail Eave Clip)
2-10d Smooth or Screw 27.6 27.6 38.6
Shank Nails Field Clip)
2-10d Smooth or Screw 38.1 38.1 41.8
Shank Nails Eave Cli
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Altusa "S" Clay Roof Adhesive 29.3 3
Tile
2 See manufacturer's component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 10.7 grams.
3M-2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Altusa "S" Clay Roof 3MT" 2-Component Foam Roof Tile Adhesive AH-160 66.5 4
Tile 3W 2-Component Foam Roof Tile Adhesive AH-160 38.7 s
3W 2-CompprjqUt VqpmBoqf Tile Adhesive AH-160 52.05 6
4 Large paddy placement of 63 grams of W 2-C:)rTrp,&ett Co"(Ipf Tile Adhesive AH-160
5 Medium paddy placement of 24 grams af,3M;AC8rrpoAgrtt F.-o+�pbf Tile Adhesive AH-160
6 Large paddy placement of 70 grams of 3MT-2-Component Foam Roof Tile Adhesive AH-160
. .. .. . .. . .
... . . ... . .
NOA No.: 14-0605.03
MIAMI•DADE Co2tmm Expiration Date: 08/26/19
• • Approval Date: 08/28/14
��•�; ; ��•�� Page 5 of
... . . . ... . .
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar Set Systems
Tile Tile Attachment
Profile Application Resistance
Altusa "S" Clay Roof Tile Mortar Set 24.50
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or
following statement: "Miami-Dade County Product Control Approved".
ALTUSA MADE IN HONDURAS
LABEL FOR ALTUSA"S"CLAY ROOF TILE.
(LOCATED ON THE UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to
properly evaluate the installation of this system.
. .. . . . . ... .
.. ... .. . . . ..
. ... ... . ... .
.
. . . . .
. .. .. . .. . .
... . . ... . .
NOA No.: 14-0605.03
MuAMi•UaDE COUNTY Expiration Date: 08/26/19
0:9 • • • 0:0 • • Approval Date: 08/28/14
• • • • • • • • • • Page 6 of 7
• .. .. • • • .. ..
PROFILE DRAWING
18-3/4"
l
10-3/4"
ALTUSA `S' CLAY ROOF TILE
.. ... . . . . . ..
. .. . . . . ... .
. .
.. .... .. . . . ...
END OF THIS ACCEPTANCE
6:0 000
• . . •
... . . ... :0 00*
NOA No.: 14-0605.03
MIAMI•DADE COUNTY Expiration Date: 08/26/19
- .•. • . . • 0:4
•4 • . Approval Date: 08/28/14
• • • • • • • • s • Page 7 of 7
• •• .• 000
• •• .•