BUILDING Permit No. 9T— %-33�1,;,
PERMIT APPLICATION Master Permit No.
FBC 20
Permit Type (circle): Building Roofing
Owner's Name(Fee Simple Titleholder) :16.p SN16CW6 P142_A.eh%k" Phone#
Owner's Address UCS IJP 91 s�
City ,t"V&W%% sl%arti State F� Zip
Tenant/Lessee Name_ Ipt Phone# N
Email I -I- e Ata Lek
Job Address(where the work is being done) 7 23-9 25- 135r W 9 k 5� .
City Miami Shores Villa e County Miami-Dade Zip .3313
FOLIO/PARCEL# 11-2a,6- u,orio� h--�'SzF 91-7n 0% 0190l, NoO.e D1.0 011,0, ylao1 p1go0 01gto(ol00
Is Building Historically Designated YES NO ✓ Flood Zone
Contractor's Company Name gp W)ah t-Into► enc Phone# �Ds6 y 35-_r/
Contractor's Address l2t S t LZ? th C,�
City M 10,M t Stated Zip_
Qualifier Name_ �A r..A MAYI Phone#
State Certificate or Registration No. & IS-4 Z Certificate of Competency No. 1336",
Contact Phone 0s, �i.1135 S I E-mail_ �o Aw�.aA rpo-Nhf�'�t� (0 41
Architect/Engineer's Name(if applicable) QAA Phone#
Value of Work For this Permit$ 41. 7_$1D Square/Linear Footage Of Work: Ubv bg�/
Type of Work: ❑Addition ❑Alteration []New 21*"Repair/Reppplace ❑Demolition
Describe Work: Pse vvX PALtc bui�d� Or,,.Q w ��n4 Otl�c.►v bP PJ(cN
o t rel, 1 fS L_5,L
r Q
Submittal Fee$ L Permit Fee$_ q��� CCF$ w CO/CC
Notary$ Training/EducationFee$ p Technology Fee$ 4
/�
Scanning$ Radon$ / DPBR$ P Zoning$
Bond$ Code Enforcement$ Double Fee$
Structural Review.$ Total Fee Now Due$
See Reverse side
Bonding Company's Name(if applicable)
Bonding Company's Address
City State
Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be a ro I and a reinspection fee will be charged.
Signature Signatur
Owner or Agent 4"Contractoi
The foregoing instrument was acknowledged before me this ;' The foregoing instrument was acknowledged before me this
day of a tx ,2013 ,by li day of A i'1 20 L-?-_,by "Ii-rA 0-d M u
who is personally known to me or who has produced who is personally known to me or who has produced
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign: _
Print:, d h Print: rs
My Commission Exp piri My Commission Expires:
JOHN BOWERS
MY COMMISSION#FF 004030 JOHN BOWERS
•41AY'oU•••
'a€ EXPIRES:April 1,2017 MY COMMISSION#FF 004030
d:' Bonded Thr.Notary Public Underwriters
EXPIRES:April 1,2017
Bonded Thru Notary Public Underwriters
APPLICATION APPROVED �''
BY Plans Examiner Zoning
Engineer Clerk checked
(Revised 07/10/07)
Miami Shores Village
Building Department REC ' �'�'i►
��
10050 N.E.2nd Avenue,Miami Shores,Florida 33138 ��� � 4
t�01 Tel:(305)795.2204 Fax:(305)756.8972
`1G INSPECTION'S PHONE NUMBER:(305)762.4949 BY;
BUILDING Permit No.
PERMIT APPLICATION Master Permit No.
FBC 20
Permit Type: BUILDING ROOFING
OWNER:Name(Fee Simple Titleholder): �jj or e- Pl&sw FA�>+- Lo•+dos• Phone#:3 uS'79 3-6 9S
Address: 7!a NI- a I
City: JAI(inn , rL State: t%l Zip: 33119
Tenant/Lessee Name: Phone#:
Email: ''W dl
JOB ADDRESS: Z S- 3 J
City: Miami Shores County: a /- : 3'J138
Folio/Pazcel#: 11' 10 � Io 6 - 01 01 Di -0 wo
Is the Building Historically Designated:Yes NOy Flood Zone:
CONTRACTOR:Company Name: dm" 2oJing , Inc-- Phone#: 3c)5-2 0-,-�55J
Address: /d/51 5u) 1 Z X Cf 1l 0
City: lam ; ��77 State: L Zip: 33 ) (?6
Qualifier Name: G�►rca KQ�m a r) , Ore„d c,�f ((�u (� phone#: 0 "Z 3 SI
State Certification or Registration#: C (2 0,51 �1 0 Certificate of Competency#:
Contact Phone#:3�5-- 260 y" 355/ Email Address: r0o1m a a roo f2 G,'C�(-/Qh ay•C-0M
DESIGNER:Architect/Engineer: N 114 Phone#:
Value of Work for this Permit:$ 4 i 010 Square/Linear Footage of Work: $O
Type of Work: DAddition OAlteration ONew ORepair/Replace ODemolition
Description of Work:�erv�� w���n� • �a•-c c�o� l►Ip
A.r �eui. �jl evict C-0 - r�>qK Ic I N deSt.zsB
Submittal Fee$ P% CO/CC$ _
Scanning Fee$ Radon Fee$ DBPR$ Bond
Notary$ Training/Education Fee$Technology Fee$
Double Fee$ Structural Review$
TOTAL FEE NOW DUE$
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT:'
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged
Signature Signature
I �(Y,- f qk,0tol 16 er-or Agent // Contractor
The foregoing instrument was acknowledged before me this l0 The foregoing instrument was acknowledgeds
before me thi
day of ,201,by C'QXto� �[a�twt�L day of--,X'-)tc�y�i=20 j tom,by_KftfeA eJL M" ,
who is personally known to me or who has produced who is personally known to me or who has produced
rl ice-•L-+) As identification and who did take an oath. Or mit, as identification and who did take an oath.
NOTARY P LIC: NOTARY PUBLIC:
Sign: bww--- Sign:
Print: a Print:
MY COMMISSION k FF 004030 9� *A
_ MY COMMISSION t FF 004030
My Commission Ex :� EXPIRES:April 1,2017 My Commission EXPIRES:April 1,2017
Bonded Thru Notary Public Underxriters Bonded Thru Notary Public Underwriters
P Plans Examiner Zoning
At RAVE)BY / g
Structural Review Clerk
(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
Permit Ivo. RF-12-16-33176
`5HortEs L�� Miami Shores Village Permit Type:Roof
10050 N.E.2nd Avenue NE Work Classification:Tile
Miami Shores,FL 33138-0000 Per I
Permit Status:APPROVED
Phone: (305)795-2204
�ORtDp'
Issue Date: 116/2017 Expiration: 07/05/2017
Project Address Parcel Number Applicant
723 NE 91 Street Number: BLDG C 113206044001
Miami Shores, FL Block: Lot: SHORES PLAZA EAST CONDON
Owner Information Address Phone Cell
SHORES PLAZA EAST CONDOMINIUM 621 NE 92 Street
- FL
Contractor(s) Phone Cell Phone
Valuation: $ 47,250.00
RODMAN ROOFING INC
(305)264-3551
� Total Sq Feet: 6800
Type of Work:Re Roof Available Inspections:
Additional Info:RE-ROOF ENTRIE BUILDING Inspection Type-.--
Classification:Commercial
Scanning:3 Up Lift Report
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $28.80
DBPR Fee Invoice# RF-12-16-62361
$6.00 01/06/2017 Check#:3210 $447.80 $50.00
DCA Fee $6.00
Education Surcharge $9.60 12/14/2016 Check#:3158 $50.00 $0.00
Permit Fee-New Roof $400.00
Scanning Fee $9.00
Technology Fee $38.40
Total: $497.80
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zonin i bove-named contractor to do the work stated.
January 06, 2017
Auth ri d ure: wner / Applicant / Contractor / Agent Date
Building Department Copy
January 06, 2017 1
AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND
SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING
SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PURSUANT TO SECTION 553.844 F.S.
TO: Miami Shores Village
10050 N.E. 2 Avenue
Miami Shores,FL 33138-0000
Re: The shores Plaza East `
723- 725 - 735 NE 91 Streeter-1,
Miami Shores,FL 33138
Roofing Permit number: RF-12-16-3376
Dear Building Official:
I Karen S. Rodman. President, certify that the roof decking attachment and fasteners have been
strengthened and corrected and a secondary water barrier has been provided as required by the
"Manual of Hurricane Mitigation Retrofits for Existing Site-Built single family Structures"as
adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C.
Sign e of u lftf ing Agent
Karen Rodman
Print Name
CCC051542
License Number
State of Florida County of Miami-Dade
Sworn to and subscribed before me this
day of 2017 .
✓ Personally known
Or produced identification
.tidy pU//
„�• JOHN BOWERS
MY COMMISSION#FF 004030
p
EXPIRES:April l 2017
Bonded Thru Notary Public Underwritem
.4-f awarmE1 raves, M. A-1 CONSULTING ENGINEERS, INC
ROOF STRUCTURES CONSULTING
ON SITE CONCENTRATED UPLIFT LOAD TESTING ROOF TILE
•, IN ACCORDANCE WITH METRO-DADE BUILDING CODE COMPLIANCE
TAS No. 106
UPLIFT TEST EXPERTS �\
SITE SPECIFIC INFORMATION
Owner's Name: Permit#:R-r /2/4,3 VA
Job Address72--3-- 72-5 —7.3-:5- — A tf �L-
Roofing Contractor:
Type of Tile:&41�iiz 7;Z Eio Date installed:
i
Approximate Roof Height: 9 feet Roof Pitch:
Type of Access to Roof: Scaffolds Ladder Other
Approximate Square Footage of Roof: 8,Pft 2
Required Testing Force: 35 lbs. Testing Equipment: F.G.E. 100
Date Tested: 63 Z` —?-0/7
EST LOCATION UPLIFT PULL TEST rEST LOCATION UPLIFT PULL TEST TEST LOCATIOP UPLIFT PULL TEST rEST LOCATIOIN UPLIFT PULL TEST rEST LOCATIO UPLIFT PULL TEST EST LOCATION UPLIFT PULL TEST
1 26 51 76 P, Z 101 126
2 27 52 77 102 127
3 28 1 53 78 103 128
4 29 54 79 104 129
5 30 55 80 105 130
6 31 56 81 106 131
7 32 57 82 107 132
8 33 58 83 108 133
9 34 59 84 109 134
10 1 35 60 85 110 135
11 36 61 86 111
12 37 62 87 112 137
13 38 63 88 113178-
14
8
14 39 64 89 114 139
15 40 65 90 115 140
16 41 66 91 116 141
17 42 67 92 117 142
18 43 68 93 118 143
19 44 69 94 119 144
20 45 70 95 120 145
21 46 71 96 1 121 146
22 47 72 97 122 147
23 48 73 98 123 148
24 49 74 . .'99::.:•.t'• s. 124• 149
25 50 75 100 125 150
IN ACCORDANCE WITH THE CRITERI F PROTOCOL PA 106,THIS RO STATIC UP4T QUALITY CONTROL TEST.
THIS TAS 106TEST HAS BEEN PE R M ED IN FULLACCORDANCE TO OUNTY,WITH NO DEVIATIONS.
THIS REPORTSUBMITTED
Jose A.Martinez Awl C4mVldne (neem
P.E.#031509 ,
A-1 CONSULTI ��RS;INC. ' Tout
Lab. Certific on 12-0228.21 Renews: 11-0607.01
4383 S.W. 701h Ct, Miami, Florida 33155 � Telephone(305)740-9550 • Fax(305)740-9550
ENGLISH: Cell (305)609-6388 • SPANISH: Cell (305)498-9804
. r `
A-1 CONSULTING ENGENTEERS WC.
ROOF STUC'TURES CDS;SULTP+;C UPLIFT TEST EXPERTS
L-AB. CERTIFICATION No.01-1224-5
4383 SW 70. CT, A LA'II FL. 33155
TEL.305-740-955 } F X305-740-9550
Owner's name: Permit#: RF-12153375
Job address: 723-725-735 SIE 91 ST I~a'9IA 'II SHORES L
Roofing contras-tor: _ RODMAN R004T:I IG INC
T�Te of tile: BARREL BARCELONA Date metalled: 03/20/2017
kpprornate roof height 19 feet Roof pitch: 3/12
Tipe of access to roof: Scaffold: Ladder: Other:
-kppro: ate square footage of roof: 68,00ft?
Required testing force: 35.Ihs
Date tested: 03/24/2017 NLumber of tests: 13 �
SKETCH OF ROOF
13c 3
_ s
55 1 ?1
1.. 1ti
5 -
X1.2 123 -
11
1Vy -
1_- 121 1.2''" 1 - 1"-
3E
SZ
11_ 11; 1.1:5 1.35 23
is;5 1'"_ 1"3 !C77 I-DE1
- E,5 t5 Y
115 1.13
1'a
N-33 5 57 SE
11 133 132' 131 1K
Reviced:: ASH
Date: 03 '24/2017
Issue Date: 12/9/2016
s' FLORIDA ROOFING,SHEET METAL&AIR CONDITIONING CONTRACTORS ASSOCIATION,INC.
RSA
1-800-767-3772 •FAX(407)671-2520
CERTIFICATE OF INSURANCE
ISSUED TO: COPY PROVIDED TO:
City Of Miami Shores Rodman Roofing, Inc.
Bldg.And Zoning Dept. 12151 SW 128Th Ct
10050 Ne 2Nd Ave. Suite#108
Miami Shores, FL 33138 Miami, FL 33186
Attention:
Rodman Roofing, Inc.
This is to Certify that: 12151 SW 128Th Ct
Suite#108
Miami, FL 33186
being subject to the provisions of the Florida Workers'Compensation Act, has secured the payment of compensation
by insuring their risk with the FLORIDA ROOFING, SHEET METAL&AIR CONDITIONING CONTRACTORS
ASSOCIATION SELF INSURERS FUND,4099 Metric Drive,Winter Park, FL 32792.
COVERAGE NUMBER: 870-001010 LIMITS
EFFECTIVE DATE: 1/1/2017 Workers'Compensation: Statutory-State of Florida
Employers'Liability: $100,000.00 Each Accident
EXPIRATION DATE: 1/1/2018 $100,000.00 Disease, Each Employee
$500,000.00 Disease, Policy Limit
REMARKS: Non-cancelable,without 30 days prior written notice,except for non-payment of premium which will be
a 10 day written notice.
Lic#"CCC051542, Karen Rodman"
This certificate is issued as a matter of information only, is not a policy and of itself does not afford any insurance.
Nothing contained in this certificate shall be constructed as extending coverage not afforded by the policy(ies)shown
above or as affording insurance to any insured not named above. This provides coverage for Florida policyholders
and Florida domiciled employees only.
By: By:
Brett Stiegel,Administrator Debra Guidry,C. CU, Un erwriting Manager
FRSA-SIF FRSA-SIF
Section AB
MIMIAMI- E Miami-Dade County HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day"
Section A(General Information) FDD
Master Permit No: Process No: -TVFD
Contractor's Name: Rodman Roofing, Inc. 4 016
Job Address:
Roof Category
❑ Low Slope ❑ Mechanically Fastened Tile 19/mortar/Adhesive Set Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Sprayed Polyurethane Foam ❑ Other:
Roof Type
❑ New Roof R(Re-Roofing ❑ Recovering ❑ Repair ElMaintenance
Are there Gas Vent Stacks located on the roof? F1E Yes No If yes,what type? ❑ Natural ❑ LPGX
Roof System Information
//
Low slope roof area(U) _- Steep Sloped area(ft.2) 8Ov(� Total(ft.Z) (o «8
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers,overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapet%;.
Perimeter Width(a'): Corner Size(a' x a'): •• •• •
i
Ito
111 � �•- •
F
f i G
S- �
Miami shores Village
3 APPROVED BY DATE
DEPT
r, 3 G►ti
oft
g tis _
IA°SCE WI't-1 ALL FEDERAL
i I'd j f:,,l Cl;X,D 9F GU'_AT,ntiS
Jile Roof System
MIAMPDA E
Miami-Dade County HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day" Section D Tile Roof System
Roof System Manufacturer:I t/
Notice of Acceptance Number(NOA): 1 a '0.7 2Z,A
Minimum Design Wind Pressures,If Applicable(from RAS 127 or Calculations):
P1: P2: P3: `leO`7
Maximum Design Wind Pressures,(From the NOA Specific system): psf
Fill in the specific roof assembly components.If a component is not required,insert not applicable(n/a)in the text box.
Deck Type: _(_X b_ Sh C,4*10t
Optional Insulation.
Optional Nailable Substrate:
Optional Nailable Substrate Attachment
Roof Slope: '712"
Roof Mean Height: y ft Basesheet Type: •..' .• ••
Method of Tile Attachment: s u
......
. ...........
Fastener Type for BasesheetAttachment: •••••
Alternate Method of Tile Attachment per NOA: tua61 to ••••
•
. •
Tile Underlayment(Cap sheet)Type::...:. ••••"
Drip Edge Size&Gauge: x £ dv r ,2�.' v ,• •
�. Tile Underlayment Attachment Method:
Drip Edge Material Type: _•
• c�
Drip Edge Fastener Type: ( y N Tile Profile:
Hook Strip/Cleat gauge or weight:
Section E
MIMIAMI A E Miami-Dade County HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day"
Section E(Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based file systems,use Method 1. Compare the values for Mr with the values from Mf.If the Mf values are
greater than or equal to the Mr values,for each area of the roof,then the file attachment method is acceptable.
P 1: 3 I_ X X -Mg: .aS =Mr1: _ l _ <_ NOA Mf
P 2: -_�� 1 x X -Mg: =Mr2: J .11' < NOA Mf
P 3: -IOa_�_ X X '_ f} _ �j L SL -Mg: =Mr3: � .`�1, <_ 3$ NOA Mf
Method 3"Uplift Based Tile Calculations Per RAS 127'
For Uplift based file systems use Method 3.Compare the values for F with the values for Fr. If the F'values are greater than or equal to the Fr values,for
each area of the roof,then the tile attachment method is acceptable.
P1: x1: "w: -W: =® xCos 0:F7=Frl:�<_� NOA F'
P2: x1: = "w: = -W: = xCos 0:El=Fr2:�<_� NOA F'
P3: x1: = xw: = -W: =� X Cos 0:F7=Fr3: 5 NOA F'
Where to Obtain Information to complete tile calculations;••••; ,• ••
...... . .. ......
Where to Find ......
Description Symbol ••••• ;•••; •
.... . .....
Design Pressure P1 or P2 or P3 Table 1 RAS 127,or by an engineer analysis prepared,signe8'kd sealed 3)rVprofesgibRM*
engineer based on ASCE 7. " '• •••• ••••••
Mean Roof Height H Job Site . . . •;•
Roof Slope 0 Job Site •••• •• ....
Aerodynamic Multiplier Product Approval(NOA) •• •
Restoring Moment due to Gravity Mg Product Approval(NOA)
Attachment Resistance Mf Product Approval(NOA)
Required Moment Resistance Mr Calculated
Minimum Attachment Resistance F Product Approval(NOA)
Required Uplift Resistance Fr Calculated
Average Tile Weight W Product Approval(NOA)
=
Tile Dimensions I length Product Approval(NOA)
w=width
f
MIAMI.Ca4t1E
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/sera
Boral Roofing,LLC
7575 Irvine Center Drive,Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barcelona 900 Concrete Roof Tile
•600.6
0 000000
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logapeit;, state.and following 6•
statement: "Miami-Dade County Product Control Approved",unless otherwise noted hereitr.:•• • •• 6666..
6666..
6666..
RENEWAL of this NOA shall be considered after a renewal application has been filed grid tliare has. wAvo 6 •
6666.
change in the applicable building code negatively affecting the performance of this prodt�- 6 6 0 6.• ., •••
TERMINATION of this NOA will occur after the expiration date or if there has been arevwQn or change in the 0•
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of anZprodusts••
006.
for sales,advertising or any other purposes shall automatically terminate this NOA.Failite tp%pmply with any 6 6 0•
section of this NOA shall be cause for termination and removal of NOA. 6"' •
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA#07-0220.04 and consists of pages I through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0222.02
MIAMI•DADE COUNTYM Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral
Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where
the pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in the
installation section herein. The attachment calculations shall be done as a moment based system..
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Barcelona 900 1= 17" TAS 112 High profile,interlocking,one-piece,'S'
w= 13" shaped,high-pressure extruded concrete roof
%2" thick tile equipped with three nail holes. For direct
deck or battened nail-on,mechanically
fastened,mortar set or adhesive set
applications.
Trim Pieces Length: varies TAS-112 Accessory trim,boosted Barcelona,concrete
Width:varies roof pieces for use at hips,rakes,ridgesand
varying thickness valley terminations manufactgr�d for ea`tite ••+•••
profile. 6' ' •• • •
0000.. . .. 0.06.0
0000..
2.1 MANUFACTURING LOCATION '•••••
0000
666666
2.1.1. Lake Wales,FL. ' •• +
•6 •• •000 f0.000
2.2 SUBMITTED EVIDENCE: •••••• •
0000.,
Test Agency Test Identifier Test Name/Repor� 13at '•• •
. 0000.•
Redland Technologies 7161-03 Static Uplift Testing" Dec.'r191 •
Appendix III TAS 102&TAS 102(A) 00
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II TAS 108(Nail-On)
Redland Technologies P0402 Withdrawal Resistance Sept. 1993
Testing of screw vs. smooth
shank nails
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108(Nail-On)
MuuHi•�e countrir NOA No.: 12-0222.02
...� Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 2 of 7
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108(Mortar Set)
Professional Service Industries, IC-1320-94 Physical Properties Feb. 1995
Inc. TAS 112
The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996
Engineering,Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996
The Center for Applied 25-7688-5 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(3" Headlap,Nails,Direct
Deck,New Construction)
The Center for Applied 25-7688-4 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(4" Headlap,Nails, Clips)
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services 520191-2-1 TAS 101 March 1999
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999
System
Walker Engineering,Inc. Evaluation 25-7183 March 1995
Calculations
Walker Engineering,Inc. Evaluation 25-7094 February 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7496 April 1996
Calculations •
Walker Engineering,Inc. Evaluation 25-7584 '• •llecemler 1296 ••• •
Calculations 25-7804b-8 ..".;•
25-7804-4&5 •••:..
25-7848-6006000
.... . .....
Walker Engineering,Inc. Evaluation Restoring Moments Due 4Q..February.;QQ7 •
Calculations Gravity *0*00 0
....
Nutting Engineers 122 TAS 112 :**:*:January 7007
. .
NOA No.: 12-0222.02
Miaratinaoe CO Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 3 of 7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with the applicable Building Code.
4. INSTALLATION
4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance
with Roofing Application Standard RAS 118,RAS 119,and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W)and Dimensions (1 x w)
Tile Profile Weight-W (lbf) Length-1 (ft) Width-w(ft)
Barcelona 900 11.5 1.417 1.08
Table 2: Aerodynamic Multipliers -X(ft)
Tile a,(ft) X(ft')
Profile Batten Application Direct Deck Application
Barcelona 900 0.289 0.313
Table 3: Restoring Moments due to Gravity- M9 (ft-lbfr.. : .. ••
Tile 2":12" 3":12" 4":12" 6":12" 6"M2':" •7"'?2" or •• •••
Profile •••• greater
Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens •Duct Battens Direst. ..
900 Deck Deck Deck Deck •• a *-o Deck• ..•
7.28 8.13 7.21 8.05 7.10 7.93 6.96 7.78 1 6.79 '• 7.61 64 7.4@-
so 00:6
.4A•••••••
*00
• •
NOA No.: 12-0222.02
EC UNTY
Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment-Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4
1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8
2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3
1 18 Screw 20.7 20.7 18.1
2 48 Screws 43.2 43.2 29.8
1-10d Smooth or Screw Shank Nail 23.1 23.1 19.0
Field Clip)
1-10d Smooth or Screw Shank Nail 29.3 29.3 24.0
Eave Clip)
2-10d Smooth or Screw Shank Nails 27.6 27.6 38.6
Field Clip)
2-10d Smooth or Screw Shank Nails 38.1 38.1 41.8
Eave Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Adhesive 29.3
1 See manufactures component approval for installation requirements.
2 Dow Chemical TileBond Average weight per patty 10.7 grams.
Pol foam Product, Inc.Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment -Mf(ft-lbf)
for Single Patty Adhesive Set Systems ••••••
9 9 0000..
Tile Tile Application MinimVm Attacl;rqenj •�
Profile *964fstancd ••••••
000900 . •
Barcelona 900 Polyfoam Pol ProTm .9 966.5 ;••••
Polyfoam Pol ProT"" •9.3 . ""
• 0000.
3 Large paddy placement of 63 rams of Pol ProTM 000000 9999 ..;..'
4 Medium paddy placement of 24 rams of Pol ProTM 00,00, 0000 •
0000..
Table 7: Attachment Resistance Expressed as a Moment- Ng(ft-1bl)
0000..
for Mortar Set Systems •• ;• �;
Tile Tile Attachment •
Profile Application Resistance
Barcelona 900 Mortar Set 24.5
5. Tile-Tite Roof Tile Mortar
NOA No.: 12-0222.02
=MIAMRDADECouNrr Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 5 of 7
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
detailed below,or following statement: "Miami-Dade County Product Control Approved".
LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
...... . .. ......
.... . .....
.. .. .... ......
. . . . ......
NOA No.: 12-0222.02
MAMMA coin Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 6 of 7
PROFILE DRAWING
NAIL HOLES
OVERLOCK
3 5/8
17 " '
\ / 13
UNDERLOCK —
BARCELONA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE ;.
...... . .. ......
.... . .....
.. .. .... ......
. . . . ......
NOA No.: 12-0222.02
MIAMI- eCouNTr Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 7 of 7
MtAM1.1aADE MIAMI-DADE COUNTY
+'►T PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
ICP Adhesives and Sealants,Inc.
12505 NW 440i Street
Coral Springs,FL.33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset®RTA-1
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product. •••:•
0000..
TERMINATION of this NOA will occur after the expiration date or if there has been a reviZ*169X change irk the •••• •
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endoysea6iit of any product,fqr •
sales,advertising or any other purposes shall automatically terminate this NOA.Failure to complywith all:�etion of;"'•;
this NOA shall be cause for termination and removal of NOA. "" *sees.
0000.. 0000 00.00
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade CountX1~lorida,�ttd followed••*•
by the expiration date may be displayed in advertising literature. If any portion of thr-WX. is displayed, they•� •
it shall be done in its entirety. . •.....
0 0000..
.. 0000
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distr'Iwtors:and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 15-1201.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0315.03
MIAMI•DADE COUNTY Expiration Date:01/03/21
Approval Date:04/07/16
Page i of 8
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof the adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset®RTA-1 as manufactured by ICP Adhesives and Sealants,Inc.as described
below in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable
building code,do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use
with approved flat, low,and high profile roof tile systems using ICP Adhesives Polyset®RTA-1.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives Polyset® N/A TAS 101 Single component polyurethane foam roof tile
RTA-1 adhesive.
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset®RTA-1 roof tile adhesive.
MANUFACTURING LOCATION:
1. Norton,OH.
PHYSICAL PROPERTIES:
Property Test Results
Density ASTM D 1622 1.95 lbs./ft.3 0 6• :••••• •• ••
Compressive Strength ASTM D 1621 7.8 psi 00 : •• • ••
Tensile Strength ASTM D 1623 15 PSI Parallel to rise *Osseo 0• see*:*
Water Absorption ASTM D 2842 4.6 Lbs./Ft2 •••••• 0 •
Moisture Vapor Transmission ASTM E 96 1.94 Perm/Inch "0004. • • :0 0
Dimensional Stability ASTM D 2126 +0.89%Volume Change @7611 ,2 Wcelts• .. ..
Closed Cell Content ASTM D 2856 54.1% 60:00: :000
00 00
••
Note: The physical properties listed above are presented as typical average values as de'terJul by '
accepted ASTM test methods and are subject to normal manufacturing variatioN 0 %•••:. :0900:
goe• . :0000:
so.*
NOA No.: 16-0315.03
MIAMMADECOUNTY Expiration Date:01/03/21
• ' Approval Date:04/07/16
Page 2 of 8
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Southwest Research Institute 01-1208-025 ASTM E 108 06/16/98
PRI Construction Materials FOP-009-02-10 Physical Properties 12/14/10
Technologies,Inc. FOP-009-02-01 TAS-101 11/8/10
FOP-009-02-02 TAS-101 11/4/10
FOP-009-02-03 TAS-101 11/8/10
FOP-009-02-04 TAS-101 11/8/10
FOP-009-02-05 TAS-101 11/8/10
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. ICP Adhesives Polyset®RTA-I can be used with flat,low,medium and high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset®RTA-1 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
F _ w
2,
F'=
MS
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
946949
•• • % • •
•4944• • •• 6666••
•
6666•• • • •
6666 • • • •
• • 6.666•
6666 • ••i••
6666•• 6666 6666•
•• •• 6666 6946••
99.4.4 �
• • • 9 •4994•
•44.4•
• • • •949••
•• • 6666 • •
NOA No.: 16-0315.03
MIAMMADECOUNTY Expiration Date:01/03/21
Approval Date:04/07/16
Page 3 of 8
INSTALLATION:
1. ICP Adhesives Polyset'RTA-I may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset®RTA-1.
2. ICF Adhesives Polyset®RTA-I shall be applied in compliance with the Component Application section
and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with
the use of ICP Adhesives Polyset®RTA-I shall provide sufficient attachment resistance to meet or exceed
the resistance values determined in compliance with Roofing Application Standards RAS 127. The
adhesive attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset®RTA-I roof tile adhesive and its components shall be installed in accordance with
Roofing Application Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and
Maintenance Booklet
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives
and Sealants,Inc.
5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after ICP Adhesives
Polyset®RTA-I has been dispensed.
6. ICP Adhesives Polyset®RTA-1 placement shall be in accordance with the'Placement Details'herein. Each
generic tile profile requires the specific placement noted herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Typical Placement Weight per paddy(grams)
Profile Detail
Flat,Low&Hi Profile # 1 12
High Profile 2-Piece Barrel #2 12
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
.0080!
MIAMI•DADE COUNTY •„• •• ••
ff-11 • • to
000,
0000!! • •! 004
•
0000!! • • •
BUILDING PERMIT 0000!•
REQUIREMENTS: •••• ,
• 0000..
As required by the Building Official or applicable building code in order to properly evaluate theinstallation of this a•;••,
.
00!000000 00000
systestem. •
m. 0000 0000 000000
0000.0 0
• • • 0 000000
00.000
• • 0 , •
0 0 0 000.00
00 0 0000 0 0
0 0
NOA No.: 16-0315.03
MLAM MAD ECOUNTY Expiration Date: 01/03/21
N111111111100
80•CT
Approval Date: 04/07/16
Page 4 of 8
ADHESIVE PLACEMENT DETAILS
PLACEMENT DETAIL#1
Strengthening d
Pad on top of tib
coryiected to paddy
Uxkwside undue tie
of tie
Undedodc
Eave course
li 4veriodc
Start Mriodc side
paddy at tie course line.
Start underiodc side paddy
EaNe appro)dr-ddy 1" above tiie •
aosure course line. .....
...... .. ......
• Y
•••••• •••• •••••
FLAT PROFILE •• •• •••• ••••••
. . . • ...•..
NOA No.: 16-0315.03
C�Wilmuelm
ECOUN Y Expiration Date: 01/03/21
• Approval Date:04/07/16
Page 5 of 8
PLACEMENT DETAIL#1(CONT...
Pad on flop of tie
connected to paddy
underneath He.
pan of tie
Underiock
Eave Overlock
course line
Start am lock side paddy
at tie course line.
Start undedock side paddy
Eave arppro)amately 1" above tile
Closure course line.
...... . .. ......
.... . .....
LOW PROFILE
...... .... .....
.. .. .... ......
. . . . ......
NOA No.: 16-0315.03
r LALM ADECOUt Expiration Date:01/03/21
Approval Date: 04/07/16
Page 6 of 8
PLACEMENT DETAIL#2
Paddy on flop d tie
oomeeted to the
two paddies
p��
underneath tile.
Pan of ti v
�.y gip
Eave oory se \
Gne
Start paddy Lndemeath pan
portion d file approAmately
1" above file Douse line.
Eave dosue
0060.
0000..
0000..
0000..
0000
0000..
HIGH PROFILE
0000.. 0000 0000.
0000..
. . . . .
.0000:000.
0000..
. ......
.. 0000
NOA No.: 16-0315.03
MUMMADE MOCOUNTY Expiration Date:01/03/21
Approval Date:04/07/16
Page 7 of 8
t 1
PLACEMENT DETAIL#2(CONT...)
• Two 2) -T'oblong
Eave ^�\ paddes side b fi
ouaw 6ne side Led
^ �\ \\ er panes
One(l)-T'paddy
on eadi sde ender
\�>> Two(2) -10'oblong
paddes side by side
under pan tiles
(eave aourseorty).
K brtar em a dcsre
0000.
0 0 0 0 0 0
. . 0
0000%
0000..
:00*0:
2-PIECE BARREL PROFILE 0*000 0 ;...;.
000&
0000.. 0000 0000.
.. 0• 0000 •00000
0000.. .'
END OF THIS ACCEPTANCE ; •
0000..
. . 0000..
00 0 0000
. .
NOA No.: 16-0315.03
MIAMEDAD;COUNTY Expiration Date: 01/03/21
33 Approval Date:04/07/16
Page 8 of 8
t
F
1
IO*
SECTION R4402.13
HIGH VELOCITY!HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope.As�it pertains to the section, it is the respnsibility of roofing contractor to provide the owner
with the required roofing permit,and to explain to the owner the content of the section.The provisions of Section
R4402 govem the minimum requirements and standards of ttie industry for roofing system installations.
Additionally,the following items should be addressed as part of the agreement between the owner ant the
contractor.The owner's initial in the designated space indicates that the item has been explained.
1• Aesthetics-Workmanshlp:the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues
such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of
the agreement between the owner and the contractor.
2• C , "- Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior
to removing the existing roof system).
3. 0C, Common roofs:Common roofs are those which have no visible delineation between neighboring
units(i.e.,townhouses,condominiums,etc.)In buildings with common roofs,the roofing contractor and/or
owner should no' 4he occupants of adjacent units of roofing to be performed.
4 � r
Exposed Ceiling' :Exposed,open beam ceilings are where the underside of the roof decking can
be viewed from below.The owner may wish to maintain the architectural appearance;therefore,roofing nail
penetration of the underside 'of the decking may not be acceptable.This provides the option of maintaining the
appearance.
:•••:•
i . •
5. CC— Ponding water:iThe current roof system and/or deck of the building may adt drain well Acd?my
cause water to pond(accumulate)in low-lying areas of the roof. Pounding can be an inaioa$on of shcUrral
distress and may require the'review of a professional structural engineer.Pounding may sWten tht life,, ;••••
expectancy and performance'of the new roofing system.Pounding conditions may not w1dent uQfll'tfl2' 00000
original roofing system is removed. Pounding conditions should be corrected.
0000.. 0000 0000.•
i 00000.
000 0000 000000
6. Overflow scuppers(wall outlets):It is required that rainwater flows off V ttp the roof is not ••
overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block ttfis discdar� a """
overflow scuppers(wall outlets)are not provided.It may be necessary to install overMw ssulpers in••• • :0 0*0
accordance with the'requirements of Sections R4402 R4403 and R4413. •
7. Ventilation:Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be
reduced.It may be beneficial to consider additional venting which can result in extending the service life of the
roof.
G
Owner/Agent's Signature Date Contractor Signa a Date
t I ;
Revised on 719/2009 LD f
1 # S 1
1 �
Notice of Asbestos Fmm f
. 7
� M IAM 1•DiADE
L Florida Department of lr ,'�11111
Environmental Protection
Division of Air Resource Management "Delivering Excellence Every Day"
fDivision of Environmental Resource Management
r Air Section
701 N.W.First Court 8th Floor
Miami,Florida 33130-1540
a
NOTICE IOF ASBESTOS RENOVATION ORDEMOLITION
4
I ;
i
Type of Notice (check one)
❑ ORIGINAL ❑ REVISED 10 CANCELLATION ,_,❑/COURTESY File#
Type of Project 11 DEMOLITION 1:1 RENOVATION M ROOFING Process#
❑ ROOF OVERLAY(NO F_.YIST1A`G ROOF:tL4TERL4L TO BE DIST-BRED)
IF DEMOLITION,WAS IT AN ORDERED DEMOLITION
DYES & NO
IF RENOVATION:
IS IT AN EMERGENCY tENOVATION OPERATION? ❑YES E( O
IS IT A PLANNED RENOVATION OPERATION? ep
} ❑YES 19 NO
1. Facility Name:
Address
city 'i State Zip �-� County
Site
Surveyed by .
0000..
Building Size (Square feet.) No.of Floors F-7 (Age in Years ••• • ••••:•
Prior Use: ��� � • •• ��••••
❑SchooUCollege/[T 'v. ❑ Residence I ❑ Small Business ...•
0000..
0000
Present Use:
❑SchooUColleg �iv. ❑ Residence ❑ Small Business Oth•• •••••
er •
0000 0000•
{ 1
000000 0000 0000.•
___ _ _ _ _ _ f _._ _._ ___..__0_000 . ___ -_ .- . • • •• • ••
II. FacilityOwner: Phone No. ❑ •
• . 0000..
Address .•. • :0000:
City -- State ''. Zip -� 0000
I
}
III. Contractor's Name: . ` Phone No.
Address "__-
;I a�_ ' O 8
City •CLM • State Zip
Florida License# =0515 q;� Is the contr. e-rempt front licensure ander section 469./102(4)F.S. ❑YES ❑ NO
!
i
IV. Scheduled Dates.
Asbestos Removal mm/d -
( dfyy). Start Date0/ / Finish Date E]/ /
Demo/Renovation(mm/dd/yy): Start Date F-�/ F7/F--j Finish Date ❑/r7/F7
V. Procedures to be used(Check All That Apply):
❑Strip&Removal ❑Glove Bag ❑Bulldozer ❑Wrecking Bali R(Wet Method ❑*Dry Method ❑Explode❑Bum Down
Other * MUST OBTAIN PRIOR DEP AP1'RO F•AL BEFORE, USING A DRF METHOD
4
VI. Procedures for Unexpected RACM:
R. Asbestos Waste Transporter: Name
C Phone No.
City State zip®�
VIII. Waste Disposal Site Name: ; (n LA Class
- _n
Address � � �� � flVtw -. Ci , i _ _
�' State
IX.Amount of RACM or ACM
Square feet of surfacuig material
C� Linear feet of pipe X. Additional Comments
Cubic feet of RACM i{ff facility components
No 196IX340s �edt5
Square feet of cementitious material Q33%M1 ng Abbe6-'G5 0
Square feet of resilient flooring �4�5 1 n 5 o n
Square feet of roofing
I certify that the above informationis correct and that an individual trained in the provisions of this regulation(40CFR Part 61,
Subpart M1)will be on-site during the demolition or renovation and evidence that the required training has been accomplished by
this person will be available for inspection during normal business hour
hairen ecAm 91 leb -4 Olt
Name of Owner/Operator ! PRINT or TYPE
Date EJ/El / Contact Ph.#' _•• � •
Signature of Owner/Operator"
....
----- .... .....
DERM USE ONLY: Postmark/Date Receivedca/o /o ,,,,•, ���� �•;��•
.. .. .... ......
,
s
4/1/2016 Property Search Application-Miami-Dade County
OFF11" E OF THE PROPERT"' APPRAISER
Generated On ;4/1/2016
Folio Sub-Division Owner Address
1 11-3206-044-0110 SHORES PLAZA EAST CONDO CASTULO REVELO JTRS 725 NE 91 ST UNIT: 1-D
VICTORIA REVELO JTRS Miami Shores
2 11-3206-044-0120 SHORES PLAZA EAST CONDO RAFAEL RODRIGUEZ 725 NE 91 ST UNIT:2-D
Miami Shores
3 11,3206-044-0170 SHORES PLAZA EAST CONDO MARIBEL MEDINA 725 NE 91 ST UNIT 3D
RENE MEDINA Miami Shores
4 11-3206-044-0180 SHORES PLAZA EAST CONDO JORGE IRIZARRY 725 NE 91 ST UNIT:4D
Miami Shores
•• ••• • • • • • ••
• •• • • • • ••• •
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
4/1/2016 Property Search Application-Miami-Dade County
E P W-) OPERTY APPRAISER
0FFlb'% E OF TH
Generated On :4/1/2016
Folio Sub-Division Owner Address
1 11-3206-044-0130 SHORES PLAZA EAST CONDO VICTORIA NEWTON DUNN 735 NE 91 ST UNIT: 1-E
SYLVAIN FABER Miami Shores
2 11-3206-044-0140 SHORES PLAZA EAST CONDO JULIETA MASULLO 735 NE 91 ST UNIT:2E
Miami Shores
3 11-3206-044-0190 SHORES PLAZA EAST CONDO CORNELIA VOIGT 735 NE 91 ST UNIT:3E
TERRENCE SHEAHAN Miami Shores
4 11-3206-044-0200 SHORES PLAZA EAST CONDO DAVID LEE NOVAK 735 NE 91 ST UNIT:4E
Miami Shores
. .• • • • . ••• .
•• ••• •• • • • ••
• ••• • ••• ••• •••
•• • • • • • • • •
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
4/1/2016 Propertv Search Application-Miami-Dade County
" Em
E int;•rte' APPRAIbr'
Generated On :4/1/2016
Folio Sub-Division Owner Address
1 11-3206-044-0090 SHORES PLAZA EAST CONDO GIRTON ROAD INVESTMENTS LLC 723 NE 91 ST UNIT: 1C
Miami Shores
2 11-3206-044-0100 SHORES PLAZA EAST CONDO EMILIO ALVAREZ 723 NE 91 ST UNIT:2C
Miami Shores
3 11-3206-044-0150 SHORES PLAZA EAST CONDO LINKING DOTS LLC 723 NE 91 ST UNIT:3C
Miami Shores
4 11-3206-044-0160 SHORES PLAZA EAST CONDO JEANNETTE BREEVELD JTRS 723 NE 91 ST UNIT:4C
PAMELA ABANDANON JTRS Miami Shores
•• ••• • • • • • ••
• • .• • • • •
• •• o • • • ••• •
•• • • • • • • • •
• •• • •• • • ••
••• • • • • ••• • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
1
2015 FLORIDA NOT FOR PROFIT CORPORATION ANNUAL REPORT FILED
DOCUMENT#726432 1 1 Apr 28, 2015
Entity Name: SHORES PLAZA EAST CONDOMINIUM, INC. Secretary of State
Current Principal Place of Business: CC5656113347
745 N.E.91ST ST
MIAMI SHORES, FL 33138
Current Mailing Address:
745 N.E. 91ST ST
MIAMI SHORES, FL 33138
FEI Number:59-0597536 Certificate of Status Desired: Yes
Name and Address of Current Registered Agent:
ZARAGOZA,OSCAR
745 NE 91 ST ST
MIAMI SHORES,FL 33138 US
i -
t
The above named entity submits this statement for the purpose of changing its registered office or registered agent;or bath,in the State of Florida.
SIGNATURE:
Electronic Signature of Registered Agent Date
Off'icer/Director Detail : I I
Title PD I i ; � 1 Title VD
Name GONZALEZ,ROBERT ' Name TALAVERA CARLOS
Address 9120 NE 8TH AVE,APT 4G Address 726 NE 92ND ST,APT 7L
City-State-Zip: MIAMI SHORES FL 33138 City-State-Zip: MIAMI SHORES FL 33138
Title STD Title D
Name ZARAGOZA,OSCAR Name DE ROJAS,JORGE
Address 726 NE 92ND ST,APT 1 L Address 9140 NE 8TH AVE,APT 4H
City-State-Zip: MIAMI SHORES FL 33138 City tate-Zip: MIAMI SHORES FL 33138
Title D !
Name ACOSTA,CECILIO ••••••
Address 736 NE 92ND ST,APT 2K •• • •• + •
City-State-Zip: MIAMI SHORES FL 33138 •
•••••• •••• •••••
•• •• •••• ••••••
• • • • ••••••
•• • Goof • •
• • •
I herebyeet*that the intoormatim hxftated on this report orsupptementai report is Mie and aacurate and that my elechonic sgnature shall have rhe same legal effect as lrmede under
oath,•that lam an ofterordkecforofthe corporatron or the receiver or bustee empowered to execute this report as required byChapter 617,Flodda Statutes and that my name appears
above,Cron an attachment wtth ao otherlike empowered. I
SIGNATURE:OSCAR ZARAGOZA! SCTY/TREASURER 04/28/2015
Electronic Signature of Signing Officer/Director Detail Date
}
4
i
i
f
I
1
EAVf-EW
FINAL
M
OF F"-' IY.Y"z��: 1V 1
R ,SaURCES IMA' AGEMENT
SIG 't1R ,_
LTE: Z u
0000..
0000..
0000..
0000..
0000..
0000
0000. . 0000
0000. 0000 0000..
0000.. 0000 0000
0000..
..0000 0 .. . .
09000:
.
0000 0..0
. . .
`M-Le
FA
�<ORIOP
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit,and to explain to the owner the content of the section.The provisions of Section
R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally,the following items should be addressed as part of the agreement between the owner ant the
contractor.The owner's initial in the designated space indicates that the item has been explained.
Aesthetics-Workmanship:the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance'standards.
Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues
such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of
the agreement between the owner and the contractor.
2• Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system).
"--'1 -
3. L� -� Common roofs:Common roofs are those which have no visible delineation between neighboring
units(i.e.,townhouses,condominiums,etc.)In buildings with common roofs,the roofing contractor and/or
owner should notify the occupants of adjacent units of roofing to be performed.
4. Exposed Ceiling:Exposed,open beam ceilings are where the underside of the roof decking can
be viewed from below.The owner may wish to maintain the architectural appearance;therefore, roofing nail
penetration of the underside of the decking may not be acceptable.This provides the option of maintaining the
appearance.
5• Ponding water:The current roof system and/or deck of the building may not drain well and may
cause water to pond(accumulate)in low-lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system.Pounding conditions may not be evident until the
original roofing system is removed.Pounding conditions should be corrected.
s• Overflow scuppers(wall outlets):It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if
overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
C
7• Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be
reduced.It may be beneficial to consider additional venting which can result in extending the service life of the
roof.
4-
Owner/Agents Signature Date Contractor Signat a Date