RF-16-532 "-R 145 - 10S9
Inspection Worksheet
Miami Shores Village
10050 N.E.2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-260877 Permit Number: RF-2-16-532
Scheduled Inspection Date:June 14,2016 Permit Type: Roof
Inspector: Mesa, Michel Inspection Type: Final
Owner: LONGMAN,JOHN Work Classification: Flat
Job Address:333 NE 92 Street
Miami Shores,FL 33138- Phone Number
Parcel Number 1132060136370
Project: <NONE>
Contractor: FLORIDA E-Z REMODELING INC Phone: (305)796-6753
Building Department Comments
NEW ROOF SYSTEM FOR ADDITION ONLY FLAT ROOF Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed E4
Failed
Correction ❑
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
-7
June 13,2016 For Inspections please call: (305)762-4949 Page 19 of 22
Permit NO. RF-2-16-532
SNRES Village Miami Shores
sPtePermit Type: Roof
10050 N.E.2nd Avenue NE r IN Work Classification:Flat
Miami Shores,FL 33138-0000 Permit Status:APPROVED
Phone: (305)795-2204
�ORLDp
Issue Date:3/1/2016 Expiration: 08/28/2016
Project Address Parcel Number Applicant
333 NE 92 Street 1132060136370
Miami Shores, FL 33138- Block: Lot: JOHNLONGMAN
Owner Information Address Phone Cell
JOHN LONGMAN 333 NE 92 Street ()_
MIAMI SHORES FL 33138-3133
333 NE 92 Street
MIAMI SHORES FL 33138-3133
Contractor(s) Phone Cell Phone Valuation: $ 4,700.00
FLORIDA E-Z REMODELING INC (305)796-6753
_. . __ _..... Total Sq Feet: 594
Type of Work:Re Roof Available Inspections:
Additional Info:NEW ROOF SYSTEM FOR ADDITION ONLY F Inspection Type:
Classification:Residential
Scanning:3 Tin Cap
Final Roof
Roof in Progress
Renailing Affidavit
Review Roof
Fees Due jAnPay Date Pay Type Amt Paid Amt Due
CCF
DBPR Fee Invoice# RF-2-16-58836
03/01/2016 Credit Card $224.50 $50.00
DCA Fee
Education Surcharge 02/26/2016 Credit Card $50.00 $0.00
Permit Fe0j-New Roof Scanning eF a Technology,Fee Total.
C 4
C J
r-.
F-+
�7
4 J
ZL
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
i
OWNERS�44IDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
constructionand zgftng. Futhermore,I authorize the above-named contractor to do the work stated.
IM March 01, 2016
Authori a Signature:Owner / Applicant / Contractor / Agent Date
r,
Building Department Copy
March 01, 2016 1
Miami Shores Village I 1TVW"-
�-�`� Building Departm_ent FEB 2120%
10050 N.E.2nd Avenue,Miami Shores, Florida 33138
Tel:(305)795-2204 Fax:(305)756-8972 BY•.
INSPECTION LINE PHONE NUMBER:(30S)762-4949
FBC 20�`i Sal%
BUILDING Master Permit Noj- L' K) -
PERMIT APPLICATION sub Permit No. P,,(`_'I(o
❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF [:] CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 552-, IA F. 9?-
City:
ZCity: Miami Shores County: Miami Dade Zip: !L- 3$
Folio/Parcel#: It QV3 - 6S-i� Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder): �&hf'\ L cr(1�Mc,�✓1 Phone#:
Address: SS-2, S�c,e.-
City: Q ayyl' State: { Zip: 37�11 S$
Tenant/Lessee Name: Phone#:
Email: n
CONTRACTOR:Company Name: jr�o�'�c�a �2 �e�, 1�nc� Phone#:
Address: I ClJ.5� St-0
City: 1'A" x State: FL. Zip:
Qualifier Name: Af0-'V S Phone#:
State Certification or Registration#: Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: ip:
Value of Work for this Permit:$ �' �'� Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New '(❑ Repair/Replace ❑ Demolition
Description of Work: "Z9J .�
Specify color of color thru tile: C�
Submittal Fee$ �y ' Permit Fee$ `'" �_� CCF$ CO/CC$
Scanning Fee$ t E� Radon Fee$ DBPR$ �' ��� Notary$
Technology Fee$ `t Training/Education Fee$. CK) Double Fee$
Structural Reviews$ Bond$ C
TOTAL FEE NOW DUE$ �`� C ' S0
(Revised02/24/2014)
3 q2 r
� � s1
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES,BOILERS, HEATERS,TANKS,AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved reinspection fee will be charged.
Signature Sig nature
OWNE r AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing insrument was acknowledged before me this
_day of te�CJ� 20 k\. 2�Q day of f-e-V:)ilZANA .20 1 to by
d� who is personally known to r Cay K\C%ac) Ao is personally known to
me or who has produced �NL-4r- wy 'PA-12— as me or who has produced 1— orX R'�P— as
identification and who did to an ath. identification and who did take an o
NOTA BLIC: NOTARY PU C:
Sig Sign:
Print: 2�Q Print:
Seal: REBECA M.PASTRANA
MY COMMISSION#EE872624 Seal: '7w�
REBECA M.PASTRANA
EXPIRES:February 07,2017 MY COhiM1SSI0N#EE872624
P3:^1.'+-1?1.tel' ° EXPiRCS:February 07,2017
APPROVED BY
Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
5t10RES Ll
NINE Miami shores Village
Building Department
7ZEORLDP' 10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
Notice to Owner — Workers' Compensation Insurance Exemption
Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05
allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to
obtaining a building permit. Pursuant to the Florida Division of Workers'Compensation Employer Facts Brochure:
An employer in the construction industry who employs one or more part-time or full-time
employees,including the owner,must obtain workers'compensation coverage. Corporate officers
or members of a limited liability company (LLC) in the construction industry may elect to be
exempt if:
1. The officer owns at least 10 percent of the stock of the corporation, or in the case of
an LLC,a statement attesting to the minimum 10 percent ownership;
2. The officer is listed as an officer of the corporation in the records of the Florida
Department of State,Division of Corporations;and
3. The corporation is registered and listed as active with the Florida Department of
State,Division of Corporations.
No more than three corporate officers per corporation or limited liability company members are
allowed to be exempt. Construction exemptions are valid for a period of two years or until a
voluntary revocation is filed or the exemption is revoked by the Division.
Your contractor is requesting a permit under this workers'compensation exemption and has acknowledge that he or she will not use
day labor,part-time employees or subcontractors for your project.The contractor has provided an affidavit stating that he or she will
be the only person allowed to work on your project. In these circumstances,Miami Shores Village does not require verification of
workers'compensation insurance coverage from the contractor's company for day labor,part-time employees or subcontractors..
Therefore,you may be personally liable for the worker compensation injuries of any person allowed to work under this
permit. Please check with your insurance carrier since most property insurance policies DO NOT cover this type of liability.
BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS
CONTENTS.
wn ntr o 14
Signature: Signature:
State eofrida State of FloridaCoun Miami-Dade County of Mia i-Dade
The foregoing was acknowledge before me this 2- � The foregoing was acknowledge before me this
day of j� ,20 11a . day of 12011,
.
By �,M� L-.nrno By 4�ec,�br C�wf a�w\oma _
who si personally known to me or hasp oduced who is personally known to me or has ce
�-
as ide ' ]cation. as identi catio
Nota Nota A 4A
SEAL:
SEAL: '""" REBECA�P�ASTI�RANA REBECA M.PASTRANA
EXP:R.ES:Felin ary 07,2017x ' EkP:kES:February 07,2017
r
FLORIDA E-Z RE.-NIODELING INC
ROOFING AND GENERAL CONTRACTOR
10051 SW 43th ST MIAMI FL 33165
PHONE (305)796-6753
EMM: HECTORI910YAHOO.COM
Date:
Mate of
County of
Before mi this day personally appeared CG nLc� who,
being duty swom,deposes and say:
That he will be the only person on the project working atF 92 Ft.33i3e
V
SwofTsto(a ed)and subscribed before me this 2_�Q_day ofU 20j__6by
Personalty Know
OR Produced Identification_ }'
Type of Identification Produced
' REBECA M.PASTRANA
MY COMMISSION#EES72624
OF EXPIRES:February 07,2017
Print,type or Stamp Name of No
STATE LICENSE CCC-1328085
STATE LICENSE CGC-058612
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application,Form
MMIIIIIIIII` • • •
• • • •
MW
I
w
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
have GAF peel and stick syslen,
installed(NOA#15-0203.09)(approx.6GO
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■
i
Y
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
Section C (Low Sloped Roof System)
Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet
and Identify Manufacturer Attachment
(If a component is not used, identify as"NA")
System Manufacturer: GAF Field: N/A.oc @ Lap,#Rows N/A @ N/A„oc
15-0203.09
NOA No.: Perimeter: N/A"oc @Lap,#Royvs N/A @ 14/�o oc
! --••-.-. 0000..
Design Wind Pressures, From RAS 128 or Calculations: Corner: N/A l,oc @Lap,# Rows 11/A•@ NJA" 'o 00
t.4 0000..
Pmax1: -49.2 Pmax2: -82.6 Pmax3: -124.3 •
Number of Fasteners Per Jgsulatigq a• ;••••;
Max. Design Pressure, From the Specific NOA Board 000000 . •• 00000
System: -125 psf 0 0.0 0
Field: N/A Perimeter N/�•�•'••'Corne�•RAO 000000
0000..
Deck:TYP . .e. Concrete non-insulated ••••• 0000.• •
. . .
12 inch thick slab Illustrate Components Noted and' .0000.
Gauge/Thickness: Details as Applicable: •
Slope: 1/4:12 Woodblocking, Gutter, Edge Termination,
Stripping, Flashing, Continuous Cleat, Cant
Anchor/Base Sheet&No.of Ply(s): Primer ASTM D41 Strip, Base Flashing, Counter- Flashing,
Coping, Etc.
Anchor/Base Sheet Fastener/Bonding Material: Indicate: Mean Roof Height, Parapet Height,
Primer applied by roller onto new concrete deck Height of Base Flashing, Component Material,
Material Thickness, Fastener Type, Fastener
Insulation Base Layer: N/A Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
Base Insulation Size and Thickness: N/A
Base Insulation Fastener/Bonding Material:
N/A
Top Insulation Layer: N/A FT.
(1)ply SBS modified granular cap sheet Parapet
Top Insulation Size and Thickness: N/A Height
(1)additional ply SBS base sheet
Top Insulation Fastener/Bonding Material: (1)ply SBS base sheet N/A; no
WA
Asphalt primer rolled on concrete deck parapet
Base Sheet(S)&No.of Ply(S): lz>plys SBS base Sneer appuea m pnmed der J_ FT.
Mean
Base Sheet Fastener/Bonding Material: Roof
selfadhedng
Height
2x6 P.T.
Ply Sheet(s)&No.of Ply(s): N/A 12 ft
Furring strip
Ply Sheet Fastener/Bonding Material:
N/A
3x3 26 gauge drip edge
Top Ply: (1) ply SBS modified cap sheet
Top Ply Fastener/Bonding Material:
self-adhering
Surfacing: The cap sheet comes with granular texture finish
r
r
A
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
Se tion D (steep Sloped Roof System)
Roof System Manufacturer:
Product Approval Number:
Minimum Design Wind Pressures If Appll ble From RAS 127or a I ion •
P1: P2: ...... .. ......
Maximum Design Pressure •••• •. .....
Product Approval Specific System: . .
Method of Tile Attachment: ••••••
Steep Sloped S stem Description
Deck Type:
Roof Slope: Type Underlayment:
12
Insulation:
Fire Barrier:
Fastener Ty & Spacing:
Ridge Ventilation?
dhesive Type:
e Cap Sheet: --�
Ro f Covering:
Mean Roof Heigh
Ty & Size Drips
Edge.
r
r
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
Section E (Tile Calculations)
For Moment based tile systems,choose either Method 1 or 2.Compare the values
for Mr with the values from M,. If the Mr values are greater than or equal to the Mr
values, for each area of the roof, then the the attachment method is acceptable.
Meth 1 "Moment Based Tile Calculations Per RAS 127" •
. . .... ......
(P,: x A = -Mg: =Mr, Product Approval • •• ••
(P2: x X _ -M 9: =Mr2 Product Approv F f •
.... . .. ......
(P3: x _ 9: =Mrs Product Appr val �,_ .....
•
000090 . .. .....
Method 2 "Simplifi Tile Calculation Per Tabl Below"
Required Moment of Resistance(Mr) Fro Table Below Product Approval M} •
M Re uired Mo nt Resis nce*
•
Mean Roof Height--lo- •.� •
Roof Slope j 15' 20' 25' 30' 40' •• •
2:12 34.4 36. 38.2 39.7 42.2
3:12 32.2 .4 3 37.4 39.8
4:12 30.4 32.2 33.8 35.1 37.3
5:12 28.4 30.1 31.6 32.8 34.9
6:12 26.4 Zf 28.0 29.4 30.5 32.4
7:12 1 2 .4 25.9 27.1 .2 30.0
*Must be used in conjunction With a list of moment based tile systems endorsed by tike
Broward County Board of Rules and Appeals.
For Uplift based the systems use Method 3. Compare the values for F'with the values for
Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then
the the attachment method is acceptable.
M\3 "Uplift Based Tile Calculations Per RAS 127"(P,: x 1: = W: x cos 0: - =Fr, Prod t Approval F'
(P2: x 1: = -W: xcos0: - =Fn Pruct Approval F'
(P,: x 1: = -W: x cos 0: - = Fr, roduct Approval F'
Wh a to Obtain Informati
Description Symbol '-
/Where to find
Design Pressure P1 or P2 or P3 RAS 127 ble 1 or by engineering analysis prepared by PE based on ASCE 7
Mean Roof Height H Job Site
Roof Slope B Job Site
Aerodynamic Multiplier A Product Appr al
Restoring Moment due to Gravity M9 Product roval
Attachment Resistance M, 2Calated
Approval
Required Moment Resistance M,
Minimum Attachment Resistance F' ct Approval
Required Uplift Resistance F, Calculated
Average Tile Weight W Product Approval
Tile Dimensions I=len Product Approval
w= idth
All calculations must be submitted to)Ke Building Official at the time of permit application.
t
SECTION 1524
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor4o provide the40o+#+ne4/ith
the required roofing permit, and to explain to the owner the content of the section. The provisions of jmjion X4402
govern the minimum requirements and standards of the industry for roofing system instttl". Additn8lly, the •
following items should be addressed as part of the agreement between the owner ant tM&M11actor. Thebwner's '•••••
initial in the designated space indicates that the item has been explained.
0000 ..
0000 . .. 0000.
0000.. 0000 0000.
2. Renailing wood decks:When replacing roofing, the existing wop�.rpp(deck mayrave to
be r nailed in accordance with the current provisions of Section R4403. (The rpof Ce* is uswally
concealed prior to removing the existing roof system). •4000..
. 0000..
.. . 0000 . 40
. 0
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking
be viewed from below. The owner may wish to maintain the architectural appearance;therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6• verflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is
of overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers (wall outlets)are not provided. It may be necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, 03 a 413.
D�
ow�j gents gna Date Contract r Signature Date
Property Address Permit Number
Revised on 7/9/2009 LD;07/01/2015;
A 4
MIAMI•DIADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
GAF
1 Campus Drive ••
Parsippany,NJ 07054 .... ......
SCOPE: •
...... . .. ......
This NOA is being issued under the applicable rules and regulations governing the ttSe"Konstruction
materials. The documentation submitted has been reviewed and accepted by Miamiwtrd'd'e.Counl} M.- •
Product Control Section to be used in Miami Dade County and other areas where allowed by the • ••: •.
...... .. . .....
Authority Having Jurisdiction(AHJ). . •
00
This NOA shall not be valid after the expiration date stated below. The Miami-Dade'auty •.
Product Control Section(In Miami Dade County) and/or the AHJ (in areas other thin Miami D;dc•:• •
County)reserve the right to have this product or material tested for quality assurance}purposes. if... ;••••;
this product or material fails to perform in the accepted manner, the manufacturer will incur the*..*
expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Liberty`" SBS Self-Adhering Modified Bitumen Roofing Systems Over
Concrete Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 14-0403.05 and consists of pages 1 through 38.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
''• • Approval Date: 04/30/15
Page 1 of 38
i
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Concrete
Maximum Design Pressure: -285 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY QPPI ICA ••••
TABLE 1 • • •
•
Test .oj:o Uct •
Product Dimensions Specification Description.• • i• •
Liberty'" SBS Self- 39.375"x 66' ASTM D4601 Self-adhering,*MS mocfifieTbase '•:
. . . ..
Adhering Base/Ply Sheet or ply sheet„VtjZ.glass rt�. ib. .rCed •0'.•..*0•.•
mat. 00.0.0 0 '
Liberty'"' SBS Self- 39.375"x 34' ASTM D6164 A granule surfaced self�ing •�'•"
Adhering Cap Sheet SBS cap sh0QtfeiAforced.Vjth a ;••••;
polyester mat. '•.'
WeatherWatch®XT Mat 36"x 50' Rolls ASTM D1970 Mat surfaced SBS modified,
Surfaced Leak Barrier 36"x 66.7' Rolls fiberglass reinforced,bituminous
sheet material for use as a leak
barrier underlayment or vapor
retarder.
UnderRoof"2 Polyester- 39%"x 67.8' rolls ASTM D1970 Self-adhering reinforced
Surfaced Leak Barrier membrane of SBS modified
asphalt with polyester surfacing
for use as a leak barrier
underlayment or vapor retarder.
GAFGLAS®Ply 4 39.37" ASTM D2178 A smooth surfaced asphaltic ply
(1 meter)Wide sheet reinforced with fiberglass
mat.
Tri-Ply®Ply 4 39.37" ASTM D2178 A smooth surfaced asphaltic ply
(1 meter)Wide sheet reinforced with fiberglass
mat.
GAFGLAS®FlexPly'" 6 39.37" ASTM D2178 A smooth surfaced asphaltic ply
(1 meter)Wide sheet reinforced with fiberglass
mat.
Ruberoid®SBS 39.37" ASTM D6163 A smooth surfaced torch applied
Heat-Weld 25 (1 meter)Wide SBS base or ply sheet reinforced
with a fiberglass mat.
Ruberoid®SBS 39.37" ASTM D6164 A smooth surfaced torch applied
Heat-Weld Smooth (1 meter) Wide SBS base or ply sheet reinforced
with a polyester mat.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�gjjgq'j 3Approval Date: 04/30/15
Page 2 of 38
r
Test Product
Product Dimensions Specification Description
Ruberoid®SBS 39.37' ASTM D6164 A granule surfaced torch applied
Heat-Weld Granule (1 meter)Wide SBS cap sheet reinforced with a
polyester mat.
Ruberoid®SBS 39.37' ASTM D6164 A fire retardant granule surfaced
Heat-Weld 170 FR (1 meter)Wide heat-welded SBS cap sheet
reinforced with a polyes4er M.
. . 0000 0000..
Ruberoid® SBS 39.37' ASTM D6164 A granule sA>��eg torch0pplied ••
Heat-Weld Plus (1 meter)Wide SBS cap sheete"aforcA w6i a 0000:.
polyester mwt•••• 0 •• •
Ruberoid®SBS 39.37' ASTM D6164 A fire retard�t;Panule;•••,• 000000
Heat-Weld Plus FR (I meter)Wide surfaced towi*a lied SBSVap 00000'
•
sheet reinfdteed with a polyester ••••••
mat. •
. . . . 0000..
Ruberoid®EnergyCap'"' 39.37' ASTM D6164 A fire retardant granule surfaced
SBS Heat-Weld Plus FR (1 meter)Wide heat-welded SSS Cap slip";•0 :000.
reinforced with a polyestg?mgt.
Cap sheet is factory coated with
Topcoat®EnergyCote'm
Elastomeric Coating.
Ruberoid®Torch Smooth 39.37" ASTM D6222 A smooth surfaced torch applied
(1 meter)Wide APP base or ply sheet reinforced
with a polyester mat.
Tri-Ply®TP4 39.37" ASTM D6222 A smooth surfaced torch applied
(1 meter)Wide APP cap,base or
ply sheet reinforced with a
polyester mat.
Ruberoid®Torch 39.37" ASTM D6222 A granule surfaced torch applied
Granule (1 meter)Wide APP cap sheet reinforced with a
polyester mat.
Ruberoid®Torch 180 39.37" ASTM D6222 A granule surfaced torch applied
(1 meter)Wide APP cap sheet reinforced with a
polyester mat.
RoofMatch'" 107 sq. ft. ASTM D6222 A granular surfaced torch applied
APP Modified Granular (9.9 m2) APP cap sheet reinforced with a
polyester mat.
Tri-Ply®TP4G 39.37" ASTM D6222 A granule surfaced torch applied
(1 meter)Wide APP cap sheet reinforced with a
polyester mat.
Ruberoid®Torch FR 39.37" ASTM D6222 A fire retardant granule surfaced
(1 meter)Wide torch applied APP cap sheet
reinforced with a polyester mat.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
IIIJINIVIT"01 Approval Date: 04/30/15
Page 3 of 38
r
Test Product
Product Dimensions Specification Description
Ruberoid® EnergyCap'" 39.37" ASTM D6222 A fire retardant granule surfaced
Torch Plus FR (1 meter)Wide torch applied APP cap sheet
reinforced with a polyester mat.
Cap sheet is factory coat(&aAji
Topcoat®E;erAote'" "" '•••••
Elastomeric.�wtt g. •• '.
Ruberoid® EnergyCapT" 39.37" ASTM D6222 A fire retarftff granule •
Torch Granule FR (1 meter)Wide surfaced torch'a lied ATIV 6p •
sheet reinfog�* Aith a polye.ter .
mat. Cap sla4&.Vfactory r4aTd •••••
with TopcoaAE4ergyCote'e
Elastomerikoat;ig. ••••••
GAFGLAS®Mineral 39.37" ASTM D3909 A granule sUrfa'ce:l aspl; itirp.cap ;••••;
Surfaced Cap Sheet (1 meter)Wide sheet reinforced with flfiorglass
mat.
GAFGLAS®EnergyCap'" 39.37" ASTM D3909 A granule surfaced asphaltic cap
BUR Mineral Surfaced (1 meter)Wide sheet reinforced with fiberglass
Cap Sheet mat. Cap sheet is factory coated
with Topcoat®EnergyCoter"
Elastomeric Coating.
Tri-Ply®Mineral Surfaced 39.37" ASTM D3909 A granule surfaced asphaltic cap
Cap Sheet (1 meter)Wide sheet reinforced with a fiberglass
mat.
Topcoat®Membrane 1, 5 or 55 Gallons ASTM D6083 Acrylic,water based elastomeric
membrane system designed to
protect various types of roof
surfaces.
Topcoat®MB Plus 5 or 55 Gallons Proprietary Water based, low VOC primer
designed to block asphalt bleed-
through.
Topcoat®Surface Seal SB 5, 55 Gallons ASTM D6083 Solvent based sprayable
thermoplastic rubber sealant
designed to protect and restore
aged roof surfaces and to increase
roof reflectivity.
Topcoat®F1exSeal 1, 5 Gallons or 1 qt. Proprietary Solvent based flashing compound
tube for gutters and other detailing.
Matrix T"307 Premium 3, 5, 55 Gallons ASTM D41 Asphalt concrete primer used to
Asphalt Primer promote adhesion of all types of
asphalt-based roofing materials.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�FjjztfApproval Date: 04/30/15
Page 4 of 38
r
� S
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(Wi D.Current�tbaj
EnergyGuard'Polyiso Insulation Polyisocyanurate foam insulation ....C4AF •
EnergyGuard'"HD Polyiso Insulation Polyisocyanurate foam insulation ""SAF •
EnergyGuardT"HD Plus Polyiso Polyisocyanurate foam insulation '•••UAF : .....
Insulation •••••• •••• .....
.. .. .. . ......
EnergyGuard'�"RH Polyiso Insulation Polyisocyanurate foam insulation .... iAF 0•
EnergyGuard'"RN Polyiso Insulation Polyisocyanurate foam insulation GAF ••••••
DensDeck®Roof Board Gypsum board Georgia4cikc Gypsuip LLC
DensDeck®Prime®Roof Board Gypsum board Georgia Pacific Gypsum LC
DensDeck®DuraGuard®Roof Board Gypsum board Georgia Pacific Gypsum LLC
Structodek®High Density Fiber Board High density fiberboard Blue Ridge Fiber Board, Inc.
Securock®Gypsum-Fiber Roof Board Gypsum board United States Gypsum
Corporation
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. N/A N/A N/A N/A
NOA No.: 15-0203.09
MIAMI•DADECOUNTY Expiration Date: 08/08/18
''s Approval Date: 04/30/15
Page 5 of 38
r
EVIDENCE SUBMITTED:
Test Agency/Identifier Report Name Date
Factory Mutual Research Corp. 3024805 4470 11/20/06
3029832 4470 05/11/07
3042905 4470 01/10/12
3036980 4470 ; 0844/01,9-' ••••..
3044688 4470 011031 20. •��06•
3041535 4470 06/68/1*1
3046328 4470 09/1�/I%
3041769 4470 05/261%L' ... •
3044862 4470 ••;••; 05/1014• ..:..'
UL LLC R10689 UL 790 03/W13 • ••••••
R1306 UL 790 05/2243
Exterior Research&Design, LLC 18035.12.02-2 TAS 114 12/1404• •
18034.03.03-2 ASTM D5147'..' 04/23103 :••••;
01501.04.03 TAS 114 041N463:
01881.09.03-2 TAS 114-D 09/09/03
Trinity I ERD 01881.11.03-2-RI TAS 114-D 08/21/07
G4280LAB.10.06 TAS 114-D 10/20/06
G4280LAB.10.06-RI TAS 114 12/06/06
G6850.08.08-R1 ASTM D6164 04/14/11
G6850.11.08 ASTM D6222 11/05/08
G6850.10.08 ASTM D6222 10/06/08
G6850.08.07-1 ASTM D3909 08/13/07
G30250.02.10-3-R1 ASTM D3909 11/26/12
G40620.07.12-2 ASTM D6222 07/17/12
G 12210.06.09 ASTM D6163 08/03/09
G30250.02.10-2 ASTM D6222 05/11/10
G34140.04.11-5 ASTM D4897 04/25/11
G121110.12.08 ASTM D4601 12/02/08
G34140.04.11-4 ASTM D4601 04/25/11
G34140.04.11-2 ASTM D6163 04/25/11
C8500SC.11.07 ASTM D6862 11/30/07
G33470.01.11 ASTM D6164 01/13/11
G31360.03.10 ASTM D6164 03/31/10
G43610.01.14 ASTM D4798 01/22/14
G43180.01.14-1 ASTM D4601 01/10/14
G43180.03.14 ASTM D6164 03/03/14
G40630.03.14 ASTM D4798 03/06/14
G43190.03.14-1 ASTM D4798 03/06/14
643190.03.14-2 ASTM D4798 03/06/14
G30250.02.10-3-R1 ASTM D3909 11/26/12
G6850.08.07-1 ASTM D3909 08/13/07
G40630.04.14-1 ASTM D6163 01/06/14
G40630.01.14-2A ASTM D6164 01/07/14
G40630.01.14-213 ASTM D6164 01/07/14
G40630.01.14-2C ASTM D6164 01/07/14
G6850.08.08-R1 ASTM D6164 04/14/11
G40620.07.12-2 ASTM D6222 07/17/12
_ NOA No.: 15-0203.09
M1AM1-DADECO2UnM Expiration Date: 08/08/18
FgjmlApproval Date: 04/30/15
Page 6 of 38
EVIDENCE SUBMITTED: (CONTINUED)
Test Auency/Identifier Report Name Date
Trinity I ERD G30250.02.10-3-R1 ASTM D3909 05/15/10
G6850.11.08 ASTM D6222 02/17fP2.
G6850.10.08 ASTM D6222 . 10117WD ,• •
G43190.11.13-1 ASTM D6222 •••� 11/1•S/13.
Atlantic&Caribbean Roof 07-047 TAS 114-D .. •• 09/07/O17- •••• •
Consulting 07-032 TAS 114-D 05/10/07
11-051 TAS 114-D ••�•�• 08/ r*11�•
.. .....
PRI Construction Technologies LLC GAF-314-02-01 ASTM D2178 ...... 08/23/,1,], ,•; •
GAF-315-02-01 ASTM D2178 •• •• 08/2;Z,LP1 : ......
GAF-084-02-01 ASTM D6083 ;••;•; 05/07/06 •
GAF-500-02-01 ASTM D6083 031:241A.
GAF-499-02-01 ASTM D6083 03/11/14 �....
GAF-411-02-01 ASTM D1289 05/02(;3;
GAF-412-02-01 ASTM D1289 05/02/13
GAF-323-02-01 ASTM D1970 12/11/11
GAF-344-02-01 ASTM D1970 06/24/12
GAF-369-02-01 ASTM D1289 10/23/12
GAF-084-02-01 ASTM D6083 05/09/06
GAF-122-02-01 TAS 139 05/09/06
Momentum Technologies,Inc. EX14A3A ASTM D6083 04/21/03
NOA No.: 15-0203.09
MIAMI•DADE COUNTYM Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 7 of 38
r
APPROVED ASSEMBLIES:
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete
0000
System Type A(1): All layers of insulation adhered to deck or vapor retarder with.pproved adhesNe. •
Vapor Retarder: One or two plies of GAFGLAS®Ply 4,Tri-Ply®Ply 4 or GA1r=S®F1e1Plr6 •••• •
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed**'ti ASTM 041
Asphalt Primer or Matrix'"' 307 Premium Asphalt Primer. '.•... ; •••• ••��•
00.00. 000• 0000.
All General and System Limitations apply. •
.. .. .. . 0000..
0000.. •
One or more layers of any of the following insulations. •.
Base Insulation Layer Insulation Fasteners •� Fgstener •�����
(Table 3) DeiWWft' ;••••
EnergyGuard'"Polyiso Insulation, EnergyGuard'"RH Polyiso Insulation 0..*
Minimum 1.5" thick N/A N/A
Note: Base insulation layer applied in OlyBond®Adhesive at 1 gal./sq. full coverage, OlyBond 500®
or OlyBond 500®Green applied in continuous 114" to 1" wide ribbons spaced 12" o.c.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
DensDeck®Prime®Roof Board, Securock®Gypsum-Fiber Roof Board
Minimum 0.25" thick N/A N/A
Note: Top insulation layer applied in OlyBond®Adhesive at 1 gal./sq. full coverage, OlyBond 500®
or OlyBond 500®Green applied in continuous'/4" to 1" wide ribbons spaced 12" o.c.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4"lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation in accordance with manufacturer's application instructions when used
with a torch adhered cap sheet.
Membrane: One ply of Liberty'" SBS Self-Adhering Cap Sheet self-adhered. Applied to the
base sheet in accordance with manufacturer's application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR,Ruberoid®EnergyCap''Torch Granule FR or
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADECOUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 8 of 38
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Ca Sheet Tri-PI ®Mineral Surfaced Ca �Sh2et or •• •
Cap Y .. .
GAFGLAS®EnergyCap'"BUR Mineral Surfaced Cap Sheet adhered in a fiil "opping of..'
approved asphalt applied within the EVT range and at a rate of 2040 lbs. sv.•••
.... .. ......
3. Topcoat®Membrane, Topcoat'MB Plus (to be used as a primer with Topo'MA'`Mem;ra**or ....
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. ••;••; 000:0,0
••:..
.. .. .. . ......
4. A fibered aluminum roof coating applied in accordance with manufacturVi FrFlication .
instructions. % •••...
Maximum Design .'. ���••
Pressure: - 152.5 psf. (See General Limitation#9) •
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�Fjguafymj Approval Date: 04/30/15
Page 9 of 38
Membrane Type: SBS, Self-Adhered
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(2): All layers of insulation are adhered to the deck or vapor retarder with approved
adhesive. Membrane is subsequently fully adhered.
0000
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFC3��A F1exP7*6� ••••;•
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed i, j1b,4STM;6410•
Asphalt Primer or Matrix'`" 307 Premium Asphalt Primer. •0 0.0 0 ••• ••
0000 •• 0000..
All General and System Limitations shall apply. '
• •• 0000.
0000.. ...
Insulation Layer Insulation Fasten e0rs• •• Fasleaen •
(Table 3) 000000 Density/02 ••
DensDeck'Prime®Roof Board,DensDeck®DuraGuard®Roof Board, Securock®dypsum-Fiber •••„0
Roof Board, Structodek®High Density Fiber Board
Minimum 0.5” thick N/A •0 0 ONTO'0 0
All insulation shall be adhered to the deck with OlyBond 500®, OlyBond 500®Green or LRF
Adhesive M applied in continuous 1/4"to 1"wide ribbons at a maximum spacing of 6"o.c. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Liberty`" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
Membrane: One ply of Liberty'"' SBS Self-Adhering Cap Sheet self-adhered. Applied to the
base sheet in accordance with manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®
EnergyCap'" BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 2040 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane) or
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -110 psf. (See General Limitation#9)
NOA No.: 15-0203.09
NIANI•DADE COUNTY Expiration Date: 08/08/18
• Approval Date: 04/30/15
Page 10 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(3): All layers of insulation are adhered to the deck or vapor retarder with approved
Soso
adhesive. Membrane is subsequently fully adhered. •
• SSSS SSSS..
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFC4L*W6 FleAA T.` ••
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primad•whhASTM i9l
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. 009000 0 :sees:
OR 0 00 00000
UnderRoof""2 Polyester-Surfaced Leak Barrier self-adhered to we eoncre0**1tk so:***
primed with ASTM D41 Asphalt Primer or Matrix'" 307 PrerY►jil"4sphalts•• `0:9*
Primer. 00•
SSSS.. SSSS..
All General and System Limitations shall apply. •
.. S
. SSSS SSS..
One or more layers of any of the following insulations. •• •
Base Insulation Layer(Optional) Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard"'Polyiso Insulation,EnergyGuard'"RH Polyiso Insulation
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
DensDeck®Roof Board, Securock®Gypsum-Fiber Roof Board
Minimum 0.25"thick N/A N/A
Note: All layers of insulation shall be adhered to the deck with OlyBond 500®or OlyBond 500®
Green applied in continuous'/<" to 1"wide ribbons at a maximum spacing of 12"o.c. Please refer
to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid® SBS Heat-Weld 25 or Ruberoid®SBS Heat-
(Optional) Weld Smooth applied in accordance with manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�F.1199',OITPJ Approval Date: 04/30/15
Page 11 of 38
r
Membrane: One or more plies of Ruberoid®SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap`" SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®TOiOh
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified aanvlar, TriPlg®• ......
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCap'"Torch gI mule FR or. •
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accord�y ith 6 ""••
manufacturer's application instructions. 6 6 6 6 • :*Goo:
"6666
0000' . . 0 • •
Surfacing: Optional on granular surfaced membranes; required for swaal l men>tji;es.
Chosen components must be listed in a current Miami-DadiENOA and..
applied in accordance with manufacturer's application insMICIons. 6 .•
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of aptrc� VA •••• •
asphalt at 60 lbs./sq. •
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or G;V LAS®
EnergyCap"'" BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 2040 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -122.5 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 12 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(4): All layers of insulation adhered to deck or vapor retarder with approved adhesive.
Membrane is subsequently fully adhered.
• 0000
. 0000..
Vapor Retarder: One or two plies of GAFGLAS'Ply 4,Tri-Ply®Ply 4 or GAFGL'AS'*'lexPZj
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet pr GAPQ ASS®
EnergyCap'"BUR Mineral Surfaced Cap Sheet adhered in a full mopping olefpproved aWW ••••:
applied within the EVT range and at a rate of 20401bs./sq. •••;•• ••••;•
YYYYYY •
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcsnb%Membraue) pr ;••••
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. so*** : •..' �.• ••
YYYYYY
4. A fibered aluminum roof coating applied in accordance with manufacturer'S.40cation•••
instructions.
Maximum Design ••• •
Pressure: -270 psf. (See General Limitation#9)
•Y • •YYIYYYY
• YYY e
NOA No.: 15-0203.09
MIAMI•DADECOUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 14 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(5): All layers of insulation adhered to deck or vapor retarder with approved adhesive.
0000
o
Membrane is subsequently fully adhered.
• g ..•. 000000
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFQj AA .Flex>r3} "�. •,
adhered in hot asphalt applied at 20-25 lbs./s to deck rimed W44STM D4j�
(Optional) p pp • q• p � •
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. •••. .. •••...
'0000.
go
• •• 0000.
All General and System Limitations shall apply. •
0000.
0000
One or more layers of any of the following insulations. " ....••
0000..
Base Insulation Layer(Optional) Insulation Fasteners ' F*tengr
0000..
(Table 3) •• Delsi�yhll
EnergyGuard'"'Polyiso Insulation,EnergyGuard'"'RH Polyiso Insulation •••�•� :"";
Minimum 1.5"thick N/A 1Q�A •
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
DensDeck®Roof Board,DensDeck®Prime Roof Board,Securock®Gypsum-Fiber Roof Board
Minimum 0.25" thick N/A N/A
Note: All layers of insulation shall be adhered to the deck with OlyBond 500®or OlyBond 500®
Green applied in continuous 1/411 to 1"wide ribbons at a maximum spacing of 12" o.c.Please refer
to Roofing Application Standard RAS 117 for insulation attachment.Top Insulation Layer shall
be primed with ASTM D41 Asphalt Primer or Matrix'"307 Premium Asphalt Primer and allowed
to dry prior to application of base sheet.
Base Sheet: One ply of Liberty'' SBS Self-Adhering Base/Ply Sheet with a minimum 4"lap
applied to the insulation in accordance with manufacturer's application
instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid® SBS Heat-Weld 25 or Ruberoid®SBS Heat-
(Optional) Weld Smooth applied in accordance with manufacturer's application
instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�ggjatlynpj Approval Date: 04/30/15
Page 15 of 38
Membrane: One or more plies of Ruberoid®SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule,Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®
EnergyCapTM SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4Z R uheroid®T ��• ••••••
Granule, Ruberoid®Torch 180, RoofMatchT"APP Modified Granular, Tri.laly® ••
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCapTM Torch aftgf1?e FR er ••• ••..:•
Ruberoid®EnergyCapTM Torch Plus FR torch applied in accoraance with •
manufacturers application instructions.
Surfacing: Optional on granular surfaced membranes; required for arnooib membIgges. ••;•••
Chosen components must be listed in a current Miami-Dade NSA anZ6.' ..••••
applied in accordance with manufacturer's application in*ff4t*ons. .'
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq• respectively in a flo4d co t of a provd
•
asphalt at 60 lbs./sq. ••....
2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Sheet or GAM'LAS®
EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 2040 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -167.5 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADECOUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 16 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(6): All layers of insulation adhered to deck or vapor retarder wit .aPPr.oved adh.e.s.1%. .
..
Membrane is subsequently fully adhered. •
....
.. .. •
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFJjLW.' Flex*Ply�""6
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed smith ASTU.D41 ••••
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. 000900 : •„' 00000
All General and System Limitations shall apply. .. .,, •0• 0 000%.0•��•
,,,,,
One or more layers of any of the following insulations. ; , ; 0 0 ',
Base Insulation Layer(Optional) Insulation Fasteners . Flgfetter 0 0 0 •
(Table 3) •• D n-siV/ft2 :"'
EnergyGuardT"'Polyiso Insulation,EnergyGuard'"RH Polyiso Insulation ••
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
Securock®Gypsum-Fiber Roof Board
Minimum 0.25"thick N/A N/A
Note: All layers of insulation shall be adhered to the deck with OlyBond 500®or OlyBond 500®
Green applied in continuous 3/411 to 1"wide ribbons at a maximum spacing of 12" o.c. Please refer
to Roofing Application Standard RAS 117 for insulation attachment.Top Insulation Layer shall
be primed with ASTM D41 Asphalt Primer or MatrixTN 307 Premium Asphalt Primer and allowed
to dry prior to application of base sheet.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid® SBS Heat-Weld 25 or Ruberoid® SBS Heat-
(Optional) Weld Smooth applied in accordance with manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
��FJJNWIYPRJ Approval Date: 04/30/15
Page 17 of 38
Membrane: One or more plies of Ruberoid® SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap'" SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions. *see
OR •
. . 0000 0000..
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch .•
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Grthttar, Tri-;?leyv•0
TP-4G, Ruberoid®Torch FR,Ruberoid®EnergyCap'"Torch 6raAu*fe FR or • •
000. 0000..
Ruberoid®EnergyCap'"Torch Plus FR torch applied in accord4r;�e*with ••• •
0000.
manufacturer's application instructions. 00*000 •
0000 0000.
Surfacing: Optional on granular surfaced membranes; required for smooth memflfands. ••••••
0000..
Chosen components must be listed in a current Miami-Da3le NQA and 0
0 •
.00000
applied in accordance with manufacturer's application inctruQtions. ;•0••• 0 0
1. Gravel or slagapplied at 400 lbs./sq. and 300 lbs./s respectively in a flood t 6a't of a es el :•0 0%
pp q• q• P Y � Ppr � .
asphalt at 60 lbs./sq. •• •
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®
EnergyCapT"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -285 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
• Approval Date: 04/30/15
Page 18 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(7): All layers of insulation adhered to deck or vapor retarder with pproved adne's18e•
Membrane is subsequently fully adhered. •• ••
Vapor Retarder: One ply of Ruberoid®Torch Smooth, Tri-Ply®TP-4 or Ruberoid
6� S Heat- " ••••••
666..
(Optional) Weld Smooth torch adhered to concrete deck primed with ASTUJ51I Asl2talt•
Primer or Matrix'" 307 Premium Asphalt Primer. 06666' ••
6666.
OR 66.90. 6666
6666.
UnderRoof" 2 Polyester-Surfaced Leak Barrier self-adhered t'o tlfe'concrete deck •••0•.
primed with ASTM D41 Asphalt Primer or Matrix'" 307 Prerxiurn0Asphalt Primer. ...
• 6 6666..
All General and System Limitations shall apply. •
. .
6666 666696
..
One or more layers of any of the following insulations. 0 0.0 :
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard'°' Polyiso Insulation,EnergyGuard""RA Polyiso Insulation,
EnergyGuard'"RH Polyiso Insulation,EnergyGuard'"RN Polyiso Insulation
Minimum 1.5" thick N/A N/A
Note: Insulation shall be adhered to the deck or optional vapor retarder with OlyBond 500®or
OlyBond 500®Green applied in continuous 1/4"to 1" ribbons wide ribbons spaced 12"o.c. After
placement walk in insulation. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: One ply of Liberty'"' SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoid®SBS
(Optional) Heat-Weld Smooth applied in accordance with manufacturer's application
instructions.
Membrane: One ply of Liberty'"' SBS Self-Adhering Cap Sheet applied in accordance with
manufacturer's application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular,Tri-Ply®
TP4G, Ruberoid®Torch FR,Ruberoid®EnergyCap'"Torch Granule FR or
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADECOUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 19 of 38
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq. •• •
2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Shut( r GAt�*L%*S® •:'
EnergyCap'"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of aproved 3splt •••,;•
applied within the EVT range and at a rate of 20-40 lbs./sq. 000000
00*000
3. Topcoat®Membrane, Topcoat®MB Plus(to be used as a primer with Topcostt i4embrane)oT .•••
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. •••••• •••• ..:..'
.. .. .. . ......
4. A fibered aluminum roof coating applied in accordance with manufacturer!-W at
pkcation ••
instructions. ••• ....:.
Maximum Design •
Pressure: -120 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�Fjjj,&411411 Approval Date: 04/30/15
Page 20 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(8): All layers of insulation adhered to deck or vapor retarder with pot asphalt. •
Membrane is subsequently fully adhered. •
Vapor Retarder: One or two plies of GAFGLAS®Ply 4 Tri-Ply®Ply 4 or GAF�o 00 Flex)sly'. •
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed wi"ASTNj p41. :6096:
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. ••••.• '0 0 0 •••
OR
0000 0000.
UnderRoof'"'2 Polyester-Surfaced Leak Barrier self-adhered to'the concrete deck **00:0
primed with ASTM D41 Asphalt Primer or Matrix'"' 307 PreiV*ium Xsphalt * ••
• 0000..
Primer. ••••••
00 0000000
All General and System Limitations shall apply. •"' 0 •
00 0
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck®DuraGuardo Roof Board, Securock®Gypsum-Fiber Roof Board
Minimum 0.25" thick N/A N/A
Note: Insulation shall be adhered to deck primed with ASTM D41 Asphalt Primer or Matrix"'307
Premium Asphalt Primer.
Or
Insulation shall be adhered to optional vapor retarder with approved mopping asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation when used with a torch adhered cap sheet applied in accordance with
manufacturer's applications instructions.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoid®SBS
(Optional) Heat-Weld Smooth in applied accordance with manufacturer's application
instructions.
Membrane: One ply of Liberty'" SBS Self-Adhering Cap Sheet applied in accordance with
manufacturer's application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'`APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCap'"Torch Granule FR or
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
WMIAMIDADECOUNDM Expiration Date: 08/08/18
�FjjzwApproval Date: 04/30/15
Page 21 of 38
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq. ,•
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap•$$8et:or „• •
GAFGLAS®EnergyCap'" BUR Mineral Surfaced Cap Sheet adhered in a-fe&I sopping 0%.• ,;
approved asphalt applied within the EVT range and at a rate of 2040 lb0m.•••
0000so0000..
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Top000tf`Membral.)lor ••••
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. ••;••; 006V* 00:00'
.. .. 00 0 0000..
4. A fibered aluminum roof coating applied in accordance with manufactured ppplication . 0•
instructions. • • 0 .:000 00 0 0.0
Maximum Design •
.. 00000000..
Pressure: -127.5 psf. (See General Limitation#9) ' 0
• . .
— NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 22 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(9): All layers of insulation adhered to deck or vapor retarder with approved aW*l*a
Membrane is subsequently fully adhered. : 0099v
. '.
Vapor Retarder: One ply of Ruberoid®Torch Smooth, Tri-Ply®TP-4 or Rubergi�l'.-)US Heat- :0 """
(Optional) Weld'" Smooth torch adhered to the concrete deck primed with ASTM DQ. �. *••••
Asphalt Primer or Matrix'"' 307 Premium Asphalt Primer. ••••` 00 0 00064
UnderRoof'"2 Polyester-Surfaced Leak Barrier self-adhered to'the concrete deck 00000*
primed with ASTM D41 Asphalt Primer or Matrix'"" 307 Prenjiurn asphalt Primer. 0
•....• 0,000.
All General and System Limitations shall apply. •
. . ......
9 0000
One or more layers of any of the following insulations. •• •
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
DensDeck®DuraGuard®Roof Board,Securock®Gypsum-Fiber Roof Board
Minimum 0.25" thick N/A N/A
Note: Insulation shall be adhered to the deck or optional vapor retarder with OlyBond 500®or
OlyBond 500®Green applied in continuous 3/4"to 1" ribbons wide ribbons spaced 12"o.c. Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoid®SBS
(Optional) Heat-Weld Smooth applied in accordance with manufacturer's application
instructions.
Membrane: One ply of Liberty"" SBS Self-Adhering Cap Sheet applied in accordance with
manufacturer's application instructions.
OR
One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCap'"Torch Granule FR or
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 23 of 38
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq. 00060
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap 51&t(:r GAI;GLQS® ...
EnergyCap'm BUR Mineral Surfaced Cap Sheet adhered in a full mopping crf awpoved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq. '•••••
0000 0000..
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcott4%#Aembrane�of 0 0
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. 00:00: 0• '0 '•:••'
06 ••
4. A fibered aluminum roof coating applied in accordance with manufacturer:s-atpkcation 0
instructions. •
0000.. 0000..
• •
Maximum Design :0000:
.6 . .ee*
Pressure: -120 psf. (See General Limitation#9) o..9 •
NOA No.: 15-0203.09
MIAMI•DADCOUNTYM Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 24 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(10): All layers of insulation adhered to primed deck or vapor retarder with hot all�lt. ••••••
Membrane is subsequently fully adhered. •
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFC4W F1exPly;"'6 ••• •
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed V0414 ASTMJ)-4d ;••••;
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. *0000* C .. .....
......
Insulation Layer: See Insulation Maximum Design Pressure Table A belowt 4lesign Pressurc:is ••
dependent upon Insulation Option used in this system. ;••;•; .'
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet with;miaijmum ilap
applied to the insulation in accordance with manufacturer's apptication :•"':
Instructions.
..
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoid®SBS
(Optional) Heat-Weld Smooth applied in accordance with manufacturer's application
instructions.
Membrane: One or more plies of Ruberoid'SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus,Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap'" SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCap''Torch Granule FR or
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
'' l Approval Date: 04/30/15
Page 25 of 38
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 601bs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or 0094
GAFGLAS®EnergyCapT" BUR Mineral Surfaced Cap Sheet adhered in a full mopping Af.•• •0.0*•
approved asphalt applied within the EVT range and at a rate of 20-40 lbs.%sqt• : .• .• 00
0.0.00 0 •
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcodl Membrane) or .• •
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. 000000 :•0 ••
00*0 • •• 0000.
4. A fibered aluminum roof coating applied in accordance with manufacturef:s-ap1licatioa... •
instructions. •• •• •. ••
0000.. •
Insulation Maximum Design Pressure Table A '
0000..
Insulation Layer Options:
1. Min. 1.5" EnergyGuard'"RA Polyiso Insulation mopped in asphalt at the rate Zf 20-25 lba.7**%) •
deck rimed with ASTM D-41 Asphalt Primer or Matrix"" 307 Premium Asphalt Primer.
Maximum Design Pressure—217.5 pst See General Limitation#9
2. Min. 1.5" EnergyGuard`Polyiso Insulation, EnergyGuard"" RN Polyiso Insulation or
EnergyGuardT" RH Polyiso Insulation mopped in asphalt at the rate of 20-25 lbs./sq. to deck
rimed with ASTM D-41 Asphalt Primer or Matrix"" 307 Premium Asphalt Primer.
Maximum Design Pressure—210 psf. (See General Limitation#9
NOA No.: 15-0203.09
MIAMNDADE COUNTY Expiration Date: 08/08/18
• Approval Date: 04/30/15
Page 26 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks,Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(11): All layers of insulation adhered to deck or vapor retarder with hot asphalt.
Membrane is subsequently fully adhered.
Vapor Retarder: One or two plies of GAFGLAS®Ply 4,Tri-Ply®Ply 4 or GAAW.A$r Flex$ly;6 ••
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primedwitk*ASTIl NJ'
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. ••••••
.... ......
Base Insulation Layer Insulation Fastener;••' Fastene'r
(Table 3) Dep%Wjt2 ••:•.'
EnergyGuardTM Polyiso Insulation,EnergyGuard"'RH Polyiso Insulation, " ••••••
•••••• • •
EnergyGuardTM RA Polyiso Insulation,EnergyGuardTM RN Polyiso Insulation ;
Minimum 1.5" thick N/A ;NfA••
Note: Base layer of insulation shall be adhered to the primed deck or optional vapor retard eriv kith '
approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.Please
refer to Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
DensDeck®DuraGuard®Roof Board, Securock®Gypsum-Fiber Roof Board
Minimum 0.25"thick N/A N/A
Note: Top layer of insulation shall be adhered with an approved mopping asphalt applied within
the EVT range and at a rate of 20-40 lbs./sq. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Base Sheet: One ply of Liberty" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application
instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoid®SBS
(Optional) Heat-Weld Smooth applied in accordance with manufacturer's application
instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTYM Expiration Date: 08/08/18
22 Approval Date: 04/30/15
Page 27 of 38
Membrane: One or more plies of Ruberoid®SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap'" SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular, Trig Pty%•
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCap`" Torch Uranble FR of ••••••
Ruberoid®EnergyCapT' Torch Plus FR torch applied in accord"p with 0•• ••
manufacturer's application instructions. ...:.. •
.... ......
Surfacing: Optional on granular surfaced membranes; required for SjAggt'h me>*br'arnes. ••'
Chosen components must be listed in a current Miami-Dads NAA and.... •
applied in accordance with manufacturer's application instreetions. G..• :
1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood cod of approved
asphalt at 60 lbs./sq. ••••.
2. GAFGLAS®Mineral Surfaced Cap Sheet,Tri-Ply®Mineral Surfaced Cap Steet or •••• •
GAFGLAS®EnergyCapT"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -127.5 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 28 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(12): All layers of insulation adhered to deck or vapor retarder with approved adhesive.
Membrane is subsequently fully adhered.
Vapor Retarder: One ply of Ruberoid®Torch Smooth,Tri-Ply®TP-4 or Ruberoid6•9BS �" "••••
(Optional) Heat-Weld Smooth, torch adhered to the concrete deck primed"4b ASTM 1441•
Asphalt Primer or Matrix'"307 Premium Asphalt Primer.
OR 000000
0000..
UnderRoof"2 Polyester-Surfaced Leak Barrier self-adhered to tivconcrete dtJ •••••
primed with ASTM D41 Asphalt Primer or Matrix'" 307 Premium'Asphaltpr:Awr. •....
00 00 00 0 0000..
Base Insulation Layer Insulation Fasteners,;•: Fastei►er .'
(Table 3) DeWitgjt2 •••• •
EnergyGuard"'Polyiso Insulation,EnergyGuard"'RH Polyiso Insulation, •'•
00 0 0000 0
EnergyGuardT"RA Polyiso Insulation,EnergyGuard'"RN Polyiso Insulation •
Minimum 1.5" thick N/A N/A
Note: Base insulation layer shall be adhered to the deck primed with ASTM D41 Asphalt Primer
or Matrix'"307 Premium Asphalt Primer or optional vapor retarder with OlyBond 500®or
OlyBond 500®Green applied in continuous 1/4"to 1" ribbons spaced 12"o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck®DuraGuard®Roof Board,Securock® Gypsum-Fiber Roof Board
Minimum 0.25" thick N/A N/A
Note: Top insulation layer shall be adhered with OlyBond 500®or OlyBond 500®Green insulation
adhesive in 1/4"to 1" beads wide ribbons spaced 12" o.c. Please refer to Roofing Application
Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoid®SBS
(Optional) Heat-Weld Smooth applied in accordance with manufacturer's application
instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 29 of 38
J
Membrane: One or more plies of Ruberoid® SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus, Ruberoid®SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap` SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatchT"APP Modified Granular, Tri;F18 •
TP-4G, Ruberoid®Torch FR,Ruberoid®EnergyCapT"Torch Crax&FR of"' ••••••
Ruberoid®EnergyCap'"'Torch Plus FR torch applied in accordjjj�y ith ••• Gee***
manufacturer's application instructions. •
.... ......
Surfacing: Optional on granular surfaced membranes; required for smarth mem renes. .....
Chosen components must be listed in a current Miami-DAMNIUA and*••• see**
applied in accordance with manufacturer's application instructions. ••••••
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat:of approved ••,;•
asphalt at 60 lbs./sq. ••• ••••
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or Gt�t� •
EnergyCap'"BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -120 psf. (See General Limitation#9)
- NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
UJURGIVII Approval Date: 04/30/15
Page 30 of 38
t
i
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank.
System Type A(13): All layers of insulation are adhered to the deck or vapor retarder with approved
adhesive. Membrane is subsequently fully adhered.
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFGLAS®F1exPly'"'6
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed with ASTM Dole
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. .'. sees ••••••
All General and System Limitations shall apply.
Insulation Layer Insulation Fasteners •• Fastener
000..
(Table 3) ." De0SjtyfW 0 •
0000 0 00 00000
Securock® Gypsum-Fiber Roof Board 00:00: •••• ••0••0
Minimum 0.25" thick N/A 0• 0• •N/� ••••
Note: Insulation shall be adhered to the deck with OlyBond®500 or OlyBond 560°1creen applied •,
in continuous 3/e"to 1" ribbons ata maximum spacing of 12"o.c. Please refer to Roofing :0 0 0:0 000000
•
Application Standard RAS 117 for insulation attachment. 0000
••606:
0
Base Sheet: One ply of Liberty'"' SBS Self-Adhering Base/Ply Sheet applied to the insiiidtioti
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Membrane: One or more plies of Ruberoid® SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid®SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid®SBS Heat-Weld Plus, Ruberoid® SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap'" SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR,Ruberoid®EnergyCap'"Torch Granule FR or
Ruberoid®EnergyCapT"Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or
GAFGLAS®EnergyCap'" BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -270 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COUNTYM Expiration Date: 08/08/18
�FgumlApproval Date: 04/30/15
Page 31 of 38
Membrane Type: APP/SBS Heat-Weld
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(14): All layers of insulation are adhered to the deck or vapor retarder with approved
adhesive. Membrane is subsequently fully adhered.
Vapor Retarder: One or two plies of GAFGLAS'Ply 4,Tri-Ply®Ply 4 or GAF•GLAS'FlemPf 6
00
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primediuith:kSTM.D41 ••
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. ••• ••
All General and System Limitations shall apply. .... .. ••••••
.... . .. .....
Insulation Layer Insulation Fasteners••• Fastener • •
(Table 3) Dehrit' /*2 ..••••
DensDeck'Roof Board, Securock'Gypsum-Fiber Roof Board ;••;• • .'
Minimum 0.25"thick N/A :lw• ••••••
Note: Insulation shall be adhered to the deck with OlyBond'500 or OlyBond S80''Greep•agplVied :•
in continuous 3/4" to 1" ribbons at a maximum spacing of 12" o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment. Insulation shall be primed with ASTM
D41 Asphalt Primer or Matrix'"' 307 Premium Asphalt Primer and allowed to dry prior to
application of base sheet.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4"lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch'XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Membrane: One or more plies of Ruberoid'SBS Heat-Weld 25, Ruberoid' SBS Heat-Weld
Smooth, Ruberoid' SBS Heat-Weld Granule, Ruberoid' SBS Heat-Weld 170 FR,
Ruberoid' SBS Heat-Weld Plus, Ruberoid'SBS Heat-Weld Plus FR or Ruberoid'
EnergyCap" SBS Heat-Weld Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid'Torch Smooth,Tri-Ply'TP4, Ruberoid'Torch
Granule, Ruberoid'Torch 180, RoofMatch'"APP Modified Granular, Tri-Ply'
TP4G, Ruberoid'Torch FR,Ruberoid'EnergyCap'"Torch Granule FR or
Ruberoid'EnergyCap"Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 32 of 38
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 601bs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFGLAS®
EnergyCapT" BUR Mineral Surfaced Cap Sheet adhered in a full mopping cf approved asphalt
applied within the EVT range and at a rate of 2040 lbs./sq. •• .. ,•
3. Topcoat®Membrane,Topcoat®MB Plus (to be used as a primer with Topc,,q 0!.*h0lembrane3 or
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. 0 0 0 0 :0000:
. . . . . 0
4. A fibered aluminum roof coating applied in accordance with manufacturer's A"licatioh 00 0.00
... . 09:00
• 0
instructions. 00 00 0 0.0 0•
Maximum Design ""`�0
Pressure: -167.5 psf. (See General Limitation#9) 0 00
•0000•
. . 0000..
.. 0000
. •
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
''f Approval Date: 04/30/15
Page 33 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type A(15): All layers of insulation are adhered to the deck with approved adhesive.
Membrane is subsequently fully adhered
Vapor Retarder: One or two plies of GAFGLAS®Ply 4, Tri-Ply®Ply 4 or GAFQLA�o Flexp,
...
(Optional) adhered in hot asphalt applied at 20-25 lbs./sq. to deck primed with ASTM,p41•
Asphalt Primer or Matrix'" 307 Premium Asphalt Primer. ••0:00
OR 000000 0
UnderRoof" 2 Polyester-Surfaced Leak Barrier self-adhered to the ooncrev deet •••
0000
primed with Matrix" 307 Premium Asphalt Primer. � " •••••
0000.. 0000
All General and System Limitations shall apply. ••••••
0000..
Insulation Layer Insulation Fasteners F$*prr •••.:.
(Table 3) :..-9: Density/ft2 •
DensDeck®Roof Board,Securock®Gypsum-Fiber Roof Board •
Minimum 0.25"thick N/A N/A
Note: Insulation shall be adhered to the deck with OlyBond®500 or OlyBond 500®Green applied
in continuous 3/4"to 1" ribbons at a maximum spacing of 12"o.c. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Base Sheet: One ply of Liberty'" SBS Self-Adhering Base/Ply Sheet applied to the insulation
with a minimum 4" lap in accordance with manufacturer's application instructions.
OR
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier self-adhered to the
insulation applied in accordance with manufacturer's applications instructions
when used with a torch adhered cap sheet.
Membrane: One or more plies of Ruberoid®SBS Heat-Weld 25, Ruberoid® SBS Heat-Weld
Smooth, Ruberoid® SBS Heat-Weld Granule, Ruberoid® SBS Heat-Weld 170 FR,
Ruberoid® SBS Heat-Weld Plus, Ruberoid® SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap" SBS Heat-Weld`"Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth, Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch`"APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR, Ruberoid®EnergyCap'" Torch Granule FR or
Ruberoid®EnergyCapT" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
Approval Date: 04/30/15
Page 34 of 38
1
f
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or GAFCIAS®
EnergyCap'm BUR Mineral Surfaced Cap Sheet adhered in a full mopping c97 alylrpved aspWr
applied within the EVT range and at a rate of 20-40 lbs./sq. •• ;•• •• .•
0000.. .. •
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with TopcbW,Membrane;or .••••.
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq. ••••'0 :0,
•• ••••:
0000 0 ..
0000.
4. A fibered aluminum roof coating applied in accordance with manufacturer•s'4PPOcatiog••:••
instructions. •• ••0000
0000..
Maximum Design •
Pressure: -122.5 psf. (See General Limitation#9)
0000..
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
"'• Approval Date: 04/30/15
Page 35 of 38
Membrane Type: APP/SBS
Deck Type 3I: Concrete Decks, Insulated
Deck Description: Structural concrete deck(minimum 2500 psi).
System Type A(16): All layers of insulation are adhered to the deck with approved adhesive.
Membrane is subsequently fully adhered
0000
All General and System Limitations apply. *00000 ••••9
.. 9. 00 9
One or more of any of the following insulation. •• • •• 0000:.
Base Layer Insulation Insulation Fasteners 000 0..Fastener •
00 0000..
(Table 3) 090 Density•*ft'** '
0000.
EnergyGuardT"Polyiso Insulation,EnergyGuardT'"RN Polyiso Insulation,Ener¢;yGuArd'"RA.. .• ••
Polyiso Insulation,EnergyGuardT"RH Polyiso Insulation,EnergyGuardTM Ultre Folyiso Insulation
Minimum 1"thick N/A : N/A •
.090.0 0000..
Top Layer Insulation Insulation Fasteners : .•. Fastener
00
(Table 3) 'Densit W. •
EnergyGuardT"HD Polyiso Insulation,EnergyGuardT"HD Plus Polyiso Insulation 0•
Minimum 1/2" thick N/A N/A
All layers of insulation is adhered to the deck with OlyBond®500 or OlyBond®500 Green applied
in 1"wide ribbons spaced 12"o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Base Sheet: LibertyTM SBS Self-Adhering Base/Ply Sheet is self-adhered.
Cap Sheet: One or more plies of Ruberoid®SBS Heat-Weld 170 FR or Ruberoid®EnergyCapTM
SBS Heat-Weld Plus FR heat-weld applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid® SBS Heat-Weld Granule, Ruberoid®Torch Granule,
Ruberoid®Torch 180,RoofMatchT"APP Modified Granular, Tri-Ply®TP-4G,
Ruberoid®Torch FR or Ruberoid®EnergyCapTM Torch Granule FR torch applied in
accordance with manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
(Optional) Chosen components must be listed in a current Miami-Dade NOA and applied in
accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 601bs./sq.
2. GAFGLAS®Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or
GAFGLAS®EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane, Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat®Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -162.5 psf. (General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
�qgjmfynpl Approval Date: 04/30/15
Page 36 of 38
Membrane Type: APP/SBS
Deck Type 3: Concrete Decks,Non-insulated
Deck Description: 2500 psi structural concrete or concrete plank
System Type F: Membrane and/or anchor sheet is adhered to primed deck.
All General and System Limitations shall apply.
Note: Concrete deck shall be primed with ASTM D41 or Matrix'"' 307 Premium Asphalt•Primrr
and allowed to dry prior to application of base sheet. ••••••
.. . .. . .
Base Sheet: One ply of Liberty'"' SBS Self-Adhering Base/Ply Sheet applietl•rgtlte prir;ed..' ..•„•
deck with a minimum 4"lapin accordance with manufacturer's AeArication
instructions. ••OR •••. •
• •• .....
*000
One ply of WeatherWatch®XT Mat Surfaced Leak Barrier se4f~ad0red tC J> e •••"
primed deck applied in accordance with manufacturer's appliptips instructions ••
when used with a torch adhered cap sheet. 0 ••• ....:.
Ply Sheet: One or more plies of Ruberoid®SBS Heat-Weld 25 or Ruberoi4.64SSS •• •• •••.:
(Optional) Heat-Weld Smooth applied in accordance with manufacturer's application*-' •
instructions.
Membrane: One ply of Liberty'" SBS Self-Adhering Cap Sheet applied in accordance with
manufacturer's application instructions.
OR
One or more plies of Ruberoid® SBS Heat-Weld 25, Ruberoid®SBS Heat-Weld
Smooth, Ruberoid®SBS Heat-Weld Granule, Ruberoid®SBS Heat-Weld 170 FR,
Ruberoid®SBS Heat-Weld Plus, Ruberoid® SBS Heat-Weld Plus FR or Ruberoid®
EnergyCap'" SBS Heat-Weld"Plus FR applied in accordance with manufacturer's
application instructions.
OR
One or more plies of Ruberoid®Torch Smooth,Tri-Ply®TP-4, Ruberoid®Torch
Granule, Ruberoid®Torch 180, RoofMatch'"APP Modified Granular, Tri-Ply®
TP-4G, Ruberoid®Torch FR,Ruberoid®EnergyCap'" Torch Granule FR or
Ruberoid®EnergyCap'" Torch Plus FR torch applied in accordance with
manufacturer's application instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be listed in a current Miami-Dade NOA and
applied in accordance with manufacturer's application instructions.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. GAFGLAS'Mineral Surfaced Cap Sheet, Tri-Ply®Mineral Surfaced Cap Sheet or
GAFGLAS®EnergyCap'" BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
3. Topcoat®Membrane,Topcoat®MB Plus (to be used as a primer with Topcoat®Membrane)or
Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
4. A fibered aluminum roof coating applied in accordance with manufacturer's application
instructions.
Maximum Design
Pressure: -125 psf. (See General Limitation#9)
NOA No.: 15-0203.09
MIAMI•DADE COYETYR Expiration Date: 08/08/18
''.I Approval Date: 04/30/15
Page 37 of 38
W
P y
CONCRETE DECK SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a
field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener
patterns and density. All testing and fastening design shall be in compliance with Testing Application
Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed
by a Florida Registered Engineer, Architect,or Registered Roof Consultant.
GENERAL LIMITATIONS: .•"'.
1. Fire classification is not part of this acceptance,refer to a current Approved Roofinggaferials.6ire�tory •••�:•
for fire ratings of this product. •••0,6 • : •.. • •••• •
2. Insulation may be installed in multiple layers. The first layer shall be attached in ddrhP?iance with-,
Product Control Approval guidelines. All other layers shall be adhered in a full moppoing of a* vvU '••••'
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically.4tched usrng the ";•••
.. . .....
fastening pattern of the top layer •
3. All standard panel sizes are acceptable for mechanical attachment. When applied�ls-,Moved asphalt, ••
panel size shall be 4'x 4'maximum. ••• •
4. An overlay and/or recovery board insulation panel is required on all applications e:er closed cell foam ;••••
insulations when the base sheet is fully mopped. If no recovery board is used the base sheet slr��lt bei •
applied using spot mopping with approved asphalt, 12" diameter circles,24" o.c. or strip mopped 8"
ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous
area of ventilation. Encircling of the strips is not acceptable. A 6"break shall be placed every 12'in
each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of
12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275
lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-
tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a
minimum fastener resistance value in conjunction with the maximum design value listed within a specific
system. Should the fastener resistance be less than that required, as determined by the Building Official,
a revised fastener spacing,prepared, signed and sealed by a Florida Registered Engineer,Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with
Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas.
Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with
Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered
Professional Engineer, Registered Architect, or Registered Roof Consultant(When this limitation is
specifically referred within this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall
conform with Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis,nor extrapolation shall be permitted for enhanced
fastening at enhanced pressure zones(i.e. perimeters, extended corners and corners). (When this
limitation is specifically referred within this NOA, General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 15-0203.09
MIAMI•DADE COUNTY Expiration Date: 08/08/18
'''• Approval Date: 04/30/15
Page 38 of 38