Loading...
RF-16-1358 Permit No. RF-5-16-1358 Miami Shores Village Permit Type:Roof e� 10050 N.E.2nd ANE venue r ��� ' Work Classification:Tile Miami Shores,FL 33138-0000 Permit Status:APPROVED Phone: (305)795-2204 Ft R1Op' issue Date:6/1312016 Expiration: 12/10/2016 Project Address Parcel Number Applicant 716 NE 92 Street Number: BLDG M 113206044001 Miami Shores, FL 33138-0000 Block: Lot: SHORES PLAZA EAST CONDO Owner Information Address Phone Cell SHORES PLAZA EAST CONDO MIAMI SHORES FL 33138-0000 Contractor(s) Phone Cell Phone Valuation: $ 16,550.00 RODMAN ROOFING INC (305)264-3551 ,_._.....r�� �µ,. ., _ ... ...........� . ._..,..�� .- Total Sq Feet: 2400 Type of Work:Re Roof Available Inspections: Additional Info:RE ROOF ENTIRE BUILDING COLOR THRU Inspection Type: Classification:Commercial Up Lift Report Scanning:4 Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Review Roof Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-5-16-59831 CCF $10.20 DBPR Fee $4.50 06/13/2016 Check#:2743 $798.20 $50.00 DCA Fee $4.50 05/18/2016 Check#:2730 $50.00 $0.00 Education Surcharge $3.40 Bond#:3107 Permit Fee-New Roof $300.00 Scanning Fee $12.00 Technology Fee $13.60 Total: $848.20 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility fQLZII work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBI CHANICAL,WWBQjVS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFXig. all the foregoin information is a curate and that all work will be done in compliance with all applicable laws regulating construction aned tractor to do the work stated. June 13, 2016 Audarized Signa ure:Owner / ontractor- / Agent Date Building Department Copy June 13,2016 1 Section AB MIAMI- E Miami-Dade County HVHZ Electronic Roof Permit Form ".Delivering Excellence Every Day" V Section A(General Information) Master Permit No:rVF1 -j Process No: del Contractor's Name: Rodman Roofing, Inc. COPY Job Address: /& e Roof Category � ❑ Low Slope ❑ Mechanically Fastened Tile E Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other. ,�� Roof Type El New Roof L� Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes LI No If yes,what type? ❑ Natural ❑ LPGX Roof System InformMMation vv Low slope roof area(ft.2) _ Steep Sloped area(ft.2)1 41?/w 2� Total(ft.2) Z/f' Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains,scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width(a'): Corner Size(a'x a'):Q e cn W UJ N y SAY 1 g 2016 �; D L o ° M � z Z <' ti BY= ni 2`1 c 0�� t s cG- o •; � 2 w 3. .. U) Z' �' m cr, CD mS < CD • • • • • • • • • ij S • • •• • • • • • O ` • •• • • • • ••• • {7 CD C • • • . • . • . . . D • • • • • • • • • p M v 000 Tile Roof System MIAMhDIADE Miami-Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System "Delivering Excellence Every Day" Roof System Manufacturer: Boral Notice of Acceptance Number(NOA): '12-0222.02 Minimum Design Wind Pressures,If Applicable(from RAS 127 or Calculations): P 1: 45.1 P 2: 68.1 P 3: 100.7 Maximum Design Wind Pressures,(From the NOA Specific system): 38.7 psf Fill in the specific roof assembly components. If a component is not required,,insert not applicable(n/a)in the text box. Deck Type: -5/8" Plywood-- . �-•_.- �� ,.-• ""+-� Optional Insulation: N/A Optional Nailable Substrate: .-r N/A Optional Nailable Substrate Attachment: Roof Slope: "/12" N/A F Roof Mean Height: ft. Basesheet Type: Method of Tile Attachment: 1 PLY ASTM 30 --Adhesive, Medium Paddy Polyfoam Polypro-- Fastener Type for Basesheet Attachment: Alternate Method of Tile Attachment per NOA: Tincaps& 1 1/4" Nails ICP Adhesives foam AH-160 Tile Underlayment(Cap Sheet)Type: Boral Tile Seal Drip Edge Size&Gauge: -3"face 26a_-_9_.-- Tile Underlayment Attachment Method: Drip Edge Material Type: Galvinized Metal- Self Adhered Drip Edge • F • ••ast4n�rl • y*•:• 1:1;4'1- iIs�.. Tile Profile: • • • • • • Barcelona 900 Hook Strip/Cleat gauge or weight: -Select Hook Strip- . ... .. ... . . . . . . . . . . . .. . . . . . .. . . . •• . • •• • . • ... . . . . ... . . . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . Section E MIMI®UADE Miami-Dade County HVHZ Electronic Roof Permit Form • "Delivering Excellence Every Day" Section E(Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems,use Method 1. Compare the values for Mr with the values from Mf.If the Mf values are greater than or equal to the Mr values,for each area of the roof,then the the attachment method is acceptable. P 1: 39.1 X X .313 = 12.23 -Mg: =Mr1: 4.18 < 38.7 NOA Mf P 2: X X .313 = 21.31 -Mg: 8.05 =Mr2: 13.26 < 38.7 NOA Mf P 3: _100.7 X X .313 = 31.51 -Mg: 8.05 =Mr3: 23.46 < 38.7 NOA Mf Method 3"Uplift Based Tile Calculations Per RAS 127' For Uplift based the systems use Method 3.Compare the values for F'with the values for Fr.If the F'values are greater than or equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable. P1: X1: Xw: -W: XCos 6: =Fr1:O55 NOA F' P2: X1:�=�Xw:�= -W:�= XCos 6: =Fr2: :5 NOA F* P3: X1:�= Xw: = -W:�=� XCos 0. =Fr3: <_ NOA F' Where to Obtain Information to complete the calculations Where to Find Description Symbol Design Pressure P1 or P2 or P3 Table 1 RAS 127,or by an engineer analysis prepared,signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier X Product Approval(NOA) Restoring Moment due to Gravity Mg Product Approval(NOA) Attachment Resistance Mf Product Approval(NOA) Required Moment Resistance• • . . Mr •• Calculated • • Minimum AttachmelltReSl$tao ; ; ;•f •• Product Approval(NOA) Required Uplift Resistance Fr Calculated Average Tile 1 jd%ht• • ••• • W ••• Product Approval(NOA) •• • • • • I—length• • Tile Dimensions.• :• •.• ;• w JVit)th•.' Product Approval(NOA) ... . . . . ... . . . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . MIAMFf]ADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing LLC. 7575 Irvine Center Drive,Suite 100 Irvine,CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPEC;fMM.'-'A6•c�o6)+of tl:is6tire NOA shall be provided to the user by the manufacturer or its distributors and shall be av jlabtJ fqr pispertipn at the job site at the request of the Building Official. •• ••• •• • • • •• This revises NOA412-1219.01 and consists of pages 1 through 4. The subtnitWAdocumenWi~on was reviewed by Juan E. Collao,R.A. . . . . . . . . . . .. .. .. . . .. . . . NOA No.: 13-1113.05 MuuMi oAne couNrr •.• Expiration Date: 07/31/17 • • • Approval Date: 03/13/14 • • • • • • • • Page 1 of 4 . .. .. . . . .. .. ... . . . ... . . ROOFING COMPONENT APPROVAL Category: Roofing Sub-Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description BORAL TileSeal 36"x 36'rolls TAS 103 SBS self-adhering asphalt sheet material with a 36"x 72' rolls ASTM D 1970 white glass re-enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURING LOCATION: 1. Brentwood,NH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories,Inc. R14610 Follow up Service 03/28/02 IRT-Arcon,Inc. 02-012 TAS 103 02/28/02 PRI Asphalt Technologies,Inc. NEI-006-02-01 TAS 103 04/01/02 PRI Asphalt Technologies,Inc. NEI-008-02-01 TAS 114(H) 07/30/02 PRI Construction Materials NEI-045-02-01 ASTM D 4798&ASTM G 155 08/08/07 Technologies,LLC. NEI-053-02-01 ASTM D 4798&ASTM G 155 05/01/08 NEI-076-02-01 TAS 103 /ASTM D4798 02/14/11 NEI-034-02-02 ASTM D 1970 01/29/13 • ••• • ••• • • NOA No.: 13-1113.05 MIAMI•®LINTY • ••• • • Expiration Date: 07/31/17 • • Approval Date: 03/13/14 ♦ • ♦•♦ Page 2 of 4 . • . . • . • . . . .•. . • ♦ ... • . APPROVED ASSEMBLIES: Deck Type 1: Wood,non-insulated Deck Description: 15/32"or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck,membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4"head lap and a 6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the laps and two staggered rows 12"o.c. the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3"head lap and minimum 6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 6"o.c.at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Approved Adhesive Set Roof Tile Systems,Mechanically Fastened Roof Tile, Metal Roofing,Wood Shake& Shingles,and Asphaltic Shingle assemblies. . .. . . . . ... . .. ... .. . . . .. • • • • • • • • • • •• • • • • • •• • • NOA No.: 13-1113.05 Muahu-DADEurmr • •.. • • Expiration Date: 07/31/17 • • • • • • . Approval Date: 03/13/14 • • • ••• • • • Page 3 of 4 ••• • • • ••• • • ti LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment;loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products,wind uplift resistance,and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6"piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment,and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below MIAMMDADE COUNTY • •• • • • • ••• • E1i&OF•THIS ACCEPTANCE . ... .• ... . . . . . . . . . . . • .. . . . . . .. . . . •• . • •• • . • NOA No.: 13-1113.05 MIAMMDADECOUNTY Expiration Date: 07/31/17 • Approval Date: 03/13/14 • Page 4 of 4 . .. .. . . . .. .. ... . . . ... . . MIAMI. ® MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/Fera Boral Roofing,LLC 7575 Irvine Center Drive,Suite 100 Irvine,CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section • to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. 00 INSPECTION: A copy of this!Airl 3M lh311be provided to the user by the manufacturer or its distributors and shall be available for insig tiijtthc et;i4eat thereluest of the Building Official. . . .. This renews and revises NOA#07-0220.04 and consists of pages 1 through 7. The submitted documefltattf wasAyi&40d by.Ajex Tigera. .. .. ' MIAMFDADE CO NOA No.: 12-0222.02 TY _ Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . ROOFING ASSEMBLY APPROVAL Category Roofing Sub-Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barcelona 900 1= 17" TAS 112 High profile,interlocking, one-piece,'S' w= 13" shaped,high-pressure extruded concrete roof '/2"thick tile equipped with three nail holes. For direct deck or battened nail-on,mechanically fastened,mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim,boosted Barcelona,concrete Width:varies roof pieces for use at hips,rakes,ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales,FL. 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102&TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix I1 TAS 108(Nail-On) Redland Technologies ••• • •P0402 Withdrawal Resistance Sept. 1993 • Testing of screw vs. smooth • •• • ••• shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 • ••• .994 TAS 108(Nail-On) . . . . . . . . . . •• • NOA No.: 12-0222.02 MiahtaowDe co rir •• Expiration Date: 04/26/17 Approval Date: 04/19/12 •:• : •:� Page 2of7 . . . . . . . . . . . .. .. . . . .. .. Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Professional Service Industries, IC-1320-94 Physical Properties Feb. 1995 Inc. TAS 112 The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996 Engineering,Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied 25-7688-5 Static Uplift Testing June 1996 Engineering,Inc. TAS 102 (3"Headlap,Nails,Direct Deck,New Construction) The Center for Applied 25-7688-4 Static Uplift Testing June 1996 Engineering,Inc. TAS 102 (4"Headlap,Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering,Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering,Inc. Evaluation 25-7183 March 1995 Calculations Walker Engineering,Inc. Evaluation 25-7094 February 1996 Calculations Walker Engineering,Inc. Evaluation 25-7496 April 1996 Calculations Walker Engineering,Inc. Evaluation 25-7584 December 1996 Calculations 25-7804b-8 25-7804-4&5 25-7848-6 Walker Engineering,Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 122 TAS 112 January 2007 .. ... . . . . . .. . .. . . . . ... . • • • • • • • • • • •• • • • • • •• • • ...• , •• ••• �• ••� ••• ExpiraOon Date: 04/26/17 22.02 MIANTY MI•DADE COU Approval Date: 04/19/12 •iY i i i •�• i i Page 3of7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight-W(lbf) Length-1 (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -X (ft) Tile A. (ft) X (ft) Profile Batten Application Direct Deck Application Barcelona 900 0.289 0.313 Table 3: Restoring Moments due to Gravity-M9 (ft-lbf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 900 Deck Deck Deck Deck Deck Deck 7.28 8.13 7.21 8.05 7.10 7.93 6.96 7.78 6.79 7.61 6.61 7.40 .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . . . . . . . .. . . •• •• MIAMI•DADE COU NOA No.: 12-0222.02 ...� � � � �•• Expiration Date: 04/26/17 Approval Date: 04/19/12 •'• "' Page 4 of 7 . . . . . . . . . . ... . . . ... . . Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 18 Screw 20.7 20.7 18.1 2 48 Screws 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail 23.1 23.1 19.0 Field Clip) 1-10d Smooth or Screw Shank Nail 29.3 29.3 24.0 Eave Clip) 2-10d Smooth or Screw Shank Nails 27.6 27.6 38.6 Field Clip) 2-10d Smooth or Screw Shank Nails 38.1 38.1 41.8 Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Adhesive 29.3 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc.Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Polyfoam Pol ProTm 66.5 Polyfoam Pol ProTm 38.74 3 Large paddy placement of 63 rams of Pol ProTm. 4 Medium paddy placement of 24 rams of Pol ProTm. Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile .. ... .Application Resistance Barcelona 900 '. .: ••• Mortar Set 24.5 5. Tile-Tite Roof Tile i0Aortar• •• ' ... . ... . . . . . . . . . . . . . . . . . . .. . . •• •• MAMMADE COON NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 ••' "' Page 5 of 7 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". OR LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . :. :. M"MADE COUNTY ••• • NOA No.: 12-0222.02 I' ... Expiration Date: 04/26/17 Approval Date: 04/19/12 • •;• ; Page 6 of 7 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . PROFILE DRAWING NAIL HOLES OVERLOCK 3 5/8 171" 13" UNDERLOCK `---_— BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE . .. . . . . ... . •+ + • •• + NOA No.: 12-0222.02 MIAMMADECOUNTW Y "• ' Expiration Date: 04/26/17 • Approval Date: 04/19/12 •Y• • • • • ••" • • Page 7of7 • • • • • • • • • • • •• •• • • • •• •• ! MIAM MIAMI-DADE COUNTY ® PRODUCT CONTROL SECTION M 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eoy/economy ICP Adhesives and Sealants,Inc. 12505 NW 44`h Street Coral Springs,FL.33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset®AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspectiQp at 14c 104 sitC at 1hq request of the Building Official. This NOA revises NOA l4-08Q5.0%artd tops4tECetpagis 1 through 11. The submitted documentation wag 18vieWed by Rldk Ttgera. • •. •.• • . . . '�. 0.0• NOA No.: 16-0315.01 MIAMI•DADE COUNTY 000 i . • Expiration Date: 0$/10/17 Approval Date:04/07/16 0:0 . . . . 0:0 . . Page 1 of 11 . . . . . ..... . . . . . •• •• . . • •• .. ... . . . ... . . ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc. as described in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP Adhesives Polyset® AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive Polyset®AH-160 ICP Adhesives Foam N/A Dispensing Equipment Dispenser RTF1000 ICP Adhesives ProPack® N/A Dispensing Equipment 30& 100 PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Prope Test Results Density ASTM D 1622 1.6lbs./ft.' Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft' Moisture Vapor Transmission ASTM E 96 31 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks •" •• +6.0%Volume Change @158°F., 100%Humidity,2 .. ... weeks Closed Cell Content •• ••: •: %9T&4 b 2gS6 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM teV*wetabds a^atC Subjeet to agrmal manufacturing variation. •• • • •• • • NOA No.: 16-0315.01 MIAMI•DADE COUNTY • •• • • •• • • • • ••• Expiration Date: 05/10/17 Approval Date:04/07/16 ... . . . . ... . . Page 2 of 11 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset' AH-160 shall solely be used with flat,low,&high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida AkIrainistrative Code.. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . • NOA No.: 16-0315.01 .. . . . . . .. . . MIAMMADE COUNTY •. . •.i ••• Expiration Date: 05/10/17 Approval Date:04/07/16 ••• .•• Page 3of11 0.11 . . . . . . . . . . INSTALLATION: 1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and Sealants,Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the"A" component and the"B" component shall be maintained between 1.0-1.15 (A): 1.0(B). 6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP Adhesives ProPack®30& 100 dispensing equipment only. 7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset®AH-160 has been dispensed. 9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . �' •' NOA No.: 16-0315.01 MIAMI-DAD,COUNTYIE •• • • •. '. Expiration Date: 05/10/17 Approval Date:04/07/16 ••• ... Page 4 of 11 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65 Profiles Flat,Low,High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel(Pan Tile) Two Piece 65-70 sq.inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. QMIAMMI-MADEOUNTY BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . '• •• NOA No.: 16-0315.01 MIAMMADE COUNTY •.• . •.i . Expiration Date: 0$/10/17 Approval Date: 04/07/16 ... ... Page 5 of 11 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . ADHESIVE PLACEMENT DETAIL# 1 nu+rtrMMOPIMtke.,nt ItddMIs I►T.x Flat/Low Profile Tile uer« • 1. Starting at the cave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam i paddy onto the underlayment positioned as shown, V under the strengthening rib closest to the overlock * 101 � �.._. '� of the tile being set. Imo• ` �., 2. Continue in same manner. Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. IftIIit"Webcmem Medium Profile/ Double Pan Tile iwheftn'W lt&A Iaytl�.n••c>irII.I 1. Starting at the cave course,apply a minimum 2" y ,e (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2kLWk% 2. Continue in same manner.Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. t�E�I�k I�tt tl .�Tihri High Profile/Single Pan Tile cr�a..I +s 1. Starting at the cave course,apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown woh. under the pan portion of the tile closest to the overlock of the tile being set. a,n 2. Continue in same manner. Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. / p—,do do 00,.�✓ • • 40� Ie• • twaiws �;n. Caxclasvre • ••• • ••• • • • • • • • • • • • • •• • •• • • NOA No.: 16-0315.01 MIAMI•DADE COUNTY ••• i• °•• :• ••i ••+ Expiration Date: 05/10/17 Approval Date:04/07/16 ... . . . . .•. . . Page 6 of 11 • • • . • . • • 0 .. . . . ... . . ADHESIVE PLACEMENT DETAIL#2 f•iE p* IL'"Maw Flat/Low Profile Tile V'OqUrUO + ► • 1. Starting at the cave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the `=r` strengthening rib of the tile closest to the overlock of the the being set. Insure approximately 17 (109.7 cm2) isterei � • °'•. 23 (148.4 cm2)square inch adhesive contact with the underside of the tile. • 2. At the second course,apply a minimum 2"(50.8mm) x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile .r.am•.. ��' being set. 3. Continue in same manner.Insure approximately 10" (64.5 cm2)- 12 (77.4 cm'-)square inch adhesive contact with the underside of the tile. a.,�t��+•ucM Medium Profile/Double Pan Tile tw�s� ere�I pytr,,,•,�a,tp•t 1. Starting at the cave course,apply a minimum 2"(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set.Insure approximately 17(109.7 cm'-)— 3 2 '' 23 (148.4 cm2)square inch adhesive contact with the 1 underside of the tile. I&I all epdw►•i -; 2. At the second course,apply a minimum 2"(50.8mm) x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the .ca.�.• underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. I 3. Continue in same manner.Insure approximately 12" (77.4 cm2)- 14(90.3 cm2)square inch adhesive contact with the underside of the tile. •• ••• • • • • •• (Instructions continued on next page) • •• • • • • ••• • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • •• •• • NOA No.: 16-0315.01 MIAMMADE COUNTY ••• i ••• i• ••i ••• Expiration Date: 05/10/17 Approval Date:04/07/16 Page 7 of 11 . . . . . • . . . . ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) �,.�,Q,,..�•ay 1+rld�rltlr�aul�til.� High Profile/Single Pan Tile 1. Starting at the eave course,apply a minimum 2"(50.8 { mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy �. onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the the being set.Insure approximately 17(109.7 cm2)— r lift 23 (148.4 cm2)square inch adhesive contact with the underside of the tile. 2. At the second course,apply a minimum 2"(50.8mm) rte, x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the • underlayment positioned as shown under the pan low 2 � + portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19(122.6 cm2)square inch adhesive contact with the underside of the tile. I • . • . . • 00 ••• • ••• • .00 • • • • 000 • • • • • • • • • • NOA No.: 16-0315.01 •• • • • • • •• • • M"kDADE COUNTY 00' •• moo •• ' ' • Expiration Date: 05/10/17 Approval Date:04/07/16 ••• • • • ••• • • Page 8 of 11 •%• •• •• • • • •• •• • • • ••• • • ADHESIVE PLACEMENT DETAIL##3 MMI through plastic cement Paddy tbetwem tdeo t.nenregrked► 1. On the eave course only,apply a minimum 2" (50.8 sanemaptimal mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy ° vaadytudertilei onto the underlayment positioned as shown,under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest 4:4im 16,�`�, to the overlock of the the being set.Leave approximately 4" (10 1.6 mm)up from the eave s pMdy y`` edge free of foam to prevent the expanded adhesive z4&'- from blocking the weep holes. Insure approximately 17-23 int(109.7-148.4 cm2)of 10 .,,t adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x V (25.4 mm)foam paddy onto the underlayment just below RaMowPm ileTile the second course line positioned foam paddy under the strengthening rib for flat tile,or under the Nafl t�pl ie ccament SMgpaddyunderSe pan portion of the tile,closest to the underlock for twhePa (betwem fled the second course tile to be installed. Insure approximately 8-9 int(51.6-58.1 cm2)of adhesive Paadytundertlet contact with the underside of the tile. mat an (Instructions continued on nextpage) 4X41n. s4bf.` � S"Ie.p�nrent- 0 2 in. Eave Closure Eave eourm Fascia Medium ProflieTlle .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . • •• NOA No.: 16-0315.01 QML"MAMMPED��XADM :' '.' ;' ..: '.' Expiration Date: 05/10/17 Approval Date:04/07/16 ... ... Page 9 of 11 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . ADHESIVE PLACEMENT DETAIL#3 (CONTINUED) t �pa"MAN tike todmfegraireel 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x3/4 t4ddl'tbet�cnttles3 (19 mm)paddy on top of the eave course tile eanets RaddytaeMertilRl surface as shown,on top of the strengthening rib for flat tile or on top of the pan portion of the rile, closest to the underlock of the first course of tile. Install second course of tile.Insure approximately �4X41n. 9(58.1 cm2) - 11 (71cm2)square inch adhesive 214 -,, ' � contact with the underside of the tile at the overlap P�W and 7(45.2 cm2)-9(58.1 cm)square inch top oftoo adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. Ease coarse A Difpodp lllgfl prolene •Y ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• • ••• • ••• • • • • • • • • • • • • •• NOA No.: 16-0315.01 . .. . . .. . . . MIAMI•DAD;COUNTY ••• Expiration Date: 05/10/17 Approval Date:04/07/16 ••• ..• Page 10 of 11 . . . . . • . . . . . .. .. . . . .. .. ... . . . .•. . . ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel (Cap and Pan)Tile 1. Starting at the eave course,apply a minimum 2" t)Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch tions in contact with the pantile. (when required)red) (50.8 mm)x 10"\254 mm)x 1"(25.4 mm)foam 2)Tum covers upside down.Place adhesive in paddy onto the underlayment positioned as to t in.from outside edge of cover tile. shown under two adjacent pan tiles. Support cave Then install the tilt.Ensure 20 to 2s sq.in.contact area. tiles from rocking until adhesive has a chance to IUnderlayment � cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2)—70(451.6 cmz) square inch adhesive contact with the underside Sheathing of the pan tile. Eave closure (motarshown) 3. Tum covers upside down exposing the underside Weephole Fascia Board of the tile.Apply a minimum 1"(25.4 nun)x 10" (254 mm)bead of adhesive directly on the inner Remove top portion of the eave course cover tile.Abut to second course of edge of each side of the cover tile.Leave pan tiles.Ensure eave end of pan and cover tiles are flush at save line. approximately 3/4"(19 mm)to 1"(25.4 mm) Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course.Insure a minimum of 20(129 cm2)-25 (161.3 cm2)square inch contact area on each side of the cover tile to the pan tile. Continue in same manner.Trim away any cured exposed foam adhesive.Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required,2"(50.8 mm)x 4"(101.6 mm)nailers or the tie wire system using galvanized, stainless steel,or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE .. ... . . . . . .. NOA No.: 16-0315.01 MIAMMAD'COUNTY a 0' '•• �' 000 •e Expiration Date: 05/10/17 Approval Date:04/07/16 ••• • • J • • • • • Page 11 of 11 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • 0 x. 1L A,ARESOjs ,T Lp .. . . . . . ••• •• 0.0 owe ••• . ••• 60, • • Y • • . • • •• • • •• • 0001137305 •.• •• • • •:• • u • • ••• • • • • • • • • • • • • ••• • • • ••• R