RF-16-1358 Permit No. RF-5-16-1358
Miami Shores Village Permit Type:Roof
e� 10050 N.E.2nd ANE
venue r
��� ' Work Classification:Tile
Miami Shores,FL 33138-0000 Permit Status:APPROVED
Phone: (305)795-2204
Ft R1Op'
issue Date:6/1312016 Expiration: 12/10/2016
Project Address Parcel Number Applicant
716 NE 92 Street Number: BLDG M 113206044001
Miami Shores, FL 33138-0000 Block: Lot: SHORES PLAZA EAST CONDO
Owner Information Address Phone Cell
SHORES PLAZA EAST CONDO
MIAMI SHORES FL 33138-0000
Contractor(s) Phone Cell Phone
Valuation: $ 16,550.00
RODMAN ROOFING INC (305)264-3551
,_._.....r�� �µ,. ., _ ... ...........� . ._..,..�� .- Total Sq Feet: 2400
Type of Work:Re Roof Available Inspections:
Additional Info:RE ROOF ENTIRE BUILDING COLOR THRU Inspection Type:
Classification:Commercial Up Lift Report
Scanning:4
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
Bond Type-Contractors Bond $500.00 Invoice# RF-5-16-59831
CCF $10.20
DBPR Fee $4.50 06/13/2016 Check#:2743 $798.20 $50.00
DCA Fee $4.50 05/18/2016 Check#:2730 $50.00 $0.00
Education Surcharge $3.40 Bond#:3107
Permit Fee-New Roof $300.00
Scanning Fee $12.00
Technology Fee $13.60
Total: $848.20
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility fQLZII work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBI CHANICAL,WWBQjVS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFXig.
all the foregoin information is a curate and that all work will be done in compliance with all applicable laws regulating
construction aned tractor to do the work stated.
June 13, 2016
Audarized Signa ure:Owner / ontractor- / Agent Date
Building Department Copy
June 13,2016 1
Section AB
MIAMI- E Miami-Dade County HVHZ Electronic Roof Permit Form
".Delivering Excellence Every Day"
V
Section A(General Information)
Master Permit No:rVF1 -j Process No: del
Contractor's Name: Rodman Roofing, Inc.
COPY
Job Address: /& e
Roof Category �
❑ Low Slope ❑ Mechanically Fastened Tile E Mortar/Adhesive Set Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Sprayed Polyurethane Foam ❑ Other.
,�� Roof Type
El New Roof L� Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance
Are there Gas Vent Stacks located on the roof? ❑ Yes LI No If yes,what type? ❑ Natural ❑ LPGX
Roof System InformMMation vv
Low slope roof area(ft.2) _ Steep Sloped area(ft.2)1 41?/w 2� Total(ft.2) Z/f'
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains,scuppers, overflow scuppers and overflow drains. Include
dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
Perimeter Width(a'): Corner Size(a'x a'):Q
e
cn W UJ N y
SAY 1 g 2016 �; D L o °
M � z
Z <' ti
BY= ni
2`1 c 0�� t s cG- o
•; � 2 w
3. ..
U)
Z' �' m
cr, CD
mS < CD
• • • • • • • • • ij S
• • •• • • • • • O `
• •• • • • • ••• •
{7 CD
C
• • • . • . • . . . D
• • • • • • • • • p M
v
000
Tile Roof System
MIAMhDIADE
Miami-Dade County HVHZ Electronic Roof Permit Form
Section D Tile Roof System
"Delivering Excellence Every Day"
Roof System Manufacturer: Boral
Notice of Acceptance Number(NOA): '12-0222.02
Minimum Design Wind Pressures,If Applicable(from RAS 127 or Calculations):
P 1: 45.1 P 2: 68.1 P 3: 100.7
Maximum Design Wind Pressures,(From the NOA Specific system): 38.7 psf
Fill in the specific roof assembly components. If a component is not required,,insert not applicable(n/a)in the text box.
Deck Type: -5/8" Plywood--
. �-•_.-
�� ,.-• ""+-� Optional Insulation:
N/A
Optional Nailable Substrate:
.-r N/A
Optional Nailable Substrate Attachment:
Roof Slope: "/12"
N/A
F
Roof Mean Height: ft. Basesheet Type:
Method of Tile Attachment: 1 PLY ASTM 30
--Adhesive, Medium Paddy Polyfoam Polypro--
Fastener Type for Basesheet Attachment:
Alternate Method of Tile Attachment per NOA: Tincaps& 1 1/4" Nails
ICP Adhesives foam AH-160
Tile Underlayment(Cap Sheet)Type:
Boral Tile Seal
Drip Edge Size&Gauge: -3"face 26a_-_9_.--
Tile Underlayment Attachment Method:
Drip Edge Material Type: Galvinized Metal- Self Adhered
Drip Edge
• F
• ••ast4n�rl
• y*•:• 1:1;4'1- iIs�.. Tile Profile:
•
• • • • • Barcelona 900
Hook Strip/Cleat gauge or weight: -Select Hook Strip-
. ...
.. ... . .
. . . . . . . . .
.. . . . . . .. . .
. •• . • •• • . •
... . . . . ... . .
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
Section E
MIMI®UADE Miami-Dade County HVHZ Electronic Roof Permit Form
•
"Delivering Excellence Every Day"
Section E(Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based tile systems,use Method 1. Compare the values for Mr with the values from Mf.If the Mf values are
greater than or equal to the Mr values,for each area of the roof,then the the attachment method is acceptable.
P 1: 39.1 X X .313 = 12.23 -Mg: =Mr1: 4.18 < 38.7 NOA Mf
P 2: X X .313 = 21.31 -Mg: 8.05 =Mr2: 13.26 < 38.7 NOA Mf
P 3: _100.7 X X .313 = 31.51 -Mg: 8.05 =Mr3: 23.46 < 38.7 NOA Mf
Method 3"Uplift Based Tile Calculations Per RAS 127'
For Uplift based the systems use Method 3.Compare the values for F'with the values for Fr.If the F'values are greater than or equal to the Fr values,for
each area of the roof,then the tile attachment method is acceptable.
P1: X1: Xw: -W: XCos 6: =Fr1:O55 NOA F'
P2: X1:�=�Xw:�= -W:�= XCos 6: =Fr2: :5 NOA F*
P3: X1:�= Xw: = -W:�=� XCos 0. =Fr3: <_ NOA F'
Where to Obtain Information to complete the calculations
Where to Find
Description Symbol
Design Pressure P1 or P2 or P3 Table 1 RAS 127,or by an engineer analysis prepared,signed and sealed by a professional
engineer based on ASCE 7.
Mean Roof Height H Job Site
Roof Slope 6 Job Site
Aerodynamic Multiplier X Product Approval(NOA)
Restoring Moment due to Gravity Mg Product Approval(NOA)
Attachment Resistance Mf Product Approval(NOA)
Required Moment Resistance• • . . Mr •• Calculated
• •
Minimum AttachmelltReSl$tao ; ; ;•f •• Product Approval(NOA)
Required Uplift Resistance Fr Calculated
Average Tile 1 jd%ht• • ••• • W ••• Product Approval(NOA)
•• • • • • I—length• •
Tile Dimensions.• :• •.• ;• w JVit)th•.' Product Approval(NOA)
... . . . . ... . .
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
MIAMFf]ADE
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Boral Roofing LLC.
7575 Irvine Center Drive,Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: BORAL TileSeal
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPEC;fMM.'-'A6•c�o6)+of tl:is6tire NOA shall be provided to the user by the manufacturer or its distributors and
shall be av jlabtJ fqr pispertipn at the job site at the request of the Building Official.
•• ••• •• • • • ••
This revises NOA412-1219.01 and consists of pages 1 through 4.
The subtnitWAdocumenWi~on was reviewed by Juan E. Collao,R.A.
. . . . . . . . . .
.. ..
.. . . .. . . .
NOA No.: 13-1113.05
MuuMi oAne couNrr •.• Expiration Date: 07/31/17
• • • Approval Date: 03/13/14
• • • • • • • • Page 1 of 4
. .. .. . . . .. ..
... . . . ... . .
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
BORAL TileSeal 36"x 36'rolls TAS 103 SBS self-adhering asphalt sheet material with a
36"x 72' rolls ASTM D 1970 white glass re-enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
MANUFACTURING LOCATION:
1. Brentwood,NH
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Underwriters Laboratories,Inc. R14610 Follow up Service 03/28/02
IRT-Arcon,Inc. 02-012 TAS 103 02/28/02
PRI Asphalt Technologies,Inc. NEI-006-02-01 TAS 103 04/01/02
PRI Asphalt Technologies,Inc. NEI-008-02-01 TAS 114(H) 07/30/02
PRI Construction Materials NEI-045-02-01 ASTM D 4798&ASTM G 155 08/08/07
Technologies,LLC. NEI-053-02-01 ASTM D 4798&ASTM G 155 05/01/08
NEI-076-02-01 TAS 103 /ASTM D4798 02/14/11
NEI-034-02-02 ASTM D 1970 01/29/13
• ••• • ••• • •
NOA No.: 13-1113.05
MIAMI•®LINTY • ••• • • Expiration Date: 07/31/17
• • Approval Date: 03/13/14
♦ • ♦•♦ Page 2 of 4
. • . . • . • . . .
.•. . • ♦ ... • .
APPROVED ASSEMBLIES:
Deck Type 1: Wood,non-insulated
Deck Description: 15/32"or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck,membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626 with a minimum 4"head lap and a
6"end lap mechanically fastened to deck with approved nails and tin caps 6"o.c. at the laps and
two staggered rows 12"o.c. the field of the roll.
Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3"head lap and minimum
6"end lap.Place the first course of membrane parallel to the eave,rolling the membrane to
obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps
without black selvage area shall be sealed under lap using an SBS modified mastic.
Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 6"o.c.at the side laps.
No nails or tin caps shall be exposed.
Surfacing: Approved for Approved Adhesive Set Roof Tile Systems,Mechanically Fastened Roof Tile,
Metal Roofing,Wood Shake& Shingles,and Asphaltic Shingle assemblies.
. .. . . . . ... .
.. ... .. . . . ..
• • • • • • • • • •
•• • • • • • •• • •
NOA No.: 13-1113.05
Muahu-DADEurmr • •.. • • Expiration Date: 07/31/17
• • • • • • . Approval Date: 03/13/14
• • • ••• • • • Page 3 of 4
••• • • • ••• • •
ti
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
Building Code.
3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
applied over a roofing Base/Anchor sheet underlayment.
5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
application.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
to the BORAL TileSeal underlayment;loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
8. Tiles shall be stored on battens on roof pitches greater than 6:12".
9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing
BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL
TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami-Dade County Product Control Department for approval provided that appropriate documentation is
provided to detail compatibility of the products,wind uplift resistance,and fire testing results.
10. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
11. When applying the membrane in the valley, start at the low point and work to the high point,rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
12. Roll or broom the entire membrane surface so as to have 100%contact with the surface,giving special attention to
overlap areas.
13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
14. All protrusions or drains shall be initially taped with a 6"piece of underlayment. This target piece shall be pressed
in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment,and sealed using an SBS modified mastic.
15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility, and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below
MIAMMDADE COUNTY
• •• • • • • ••• •
E1i&OF•THIS ACCEPTANCE
. ...
.• ... . .
. . . . . . . . .
•
.. . . . . . .. . .
. •• . • •• • . •
NOA No.: 13-1113.05
MIAMMDADECOUNTY Expiration Date: 07/31/17
• Approval Date: 03/13/14
• Page 4 of 4
. .. .. . . . .. ..
... . . . ... . .
MIAMI.
® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/Fera
Boral Roofing,LLC
7575 Irvine Center Drive,Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section
• to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barcelona 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
00
INSPECTION: A copy of this!Airl 3M lh311be provided to the user by the manufacturer or its distributors and
shall be available for insig tiijtthc et;i4eat thereluest of the Building Official.
. . ..
This renews and revises NOA#07-0220.04 and consists of pages 1 through 7.
The submitted documefltattf wasAyi&40d by.Ajex Tigera.
.. ..
'
MIAMFDADE CO NOA No.: 12-0222.02
TY
_ Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 1 of
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral
Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where
the pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in the
installation section herein. The attachment calculations shall be done as a moment based system..
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Barcelona 900 1= 17" TAS 112 High profile,interlocking, one-piece,'S'
w= 13" shaped,high-pressure extruded concrete roof
'/2"thick tile equipped with three nail holes. For direct
deck or battened nail-on,mechanically
fastened,mortar set or adhesive set
applications.
Trim Pieces Length: varies TAS-112 Accessory trim,boosted Barcelona,concrete
Width:varies roof pieces for use at hips,rakes,ridges and
varying thickness valley terminations manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
2.1.1. Lake Wales,FL.
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102&TAS 102(A)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix I1 TAS 108(Nail-On)
Redland Technologies ••• • •P0402 Withdrawal Resistance Sept. 1993
• Testing of screw vs. smooth
• •• • ••• shank nails
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
• ••• .994 TAS 108(Nail-On)
. . . . . . . . . .
•• • NOA No.: 12-0222.02
MiahtaowDe co rir •• Expiration Date: 04/26/17
Approval Date: 04/19/12
•:• : •:�
Page 2of7
. . . . . . . . . .
. .. .. . . . .. ..
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108 (Mortar Set)
Professional Service Industries, IC-1320-94 Physical Properties Feb. 1995
Inc. TAS 112
The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996
Engineering,Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996
The Center for Applied 25-7688-5 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(3"Headlap,Nails,Direct
Deck,New Construction)
The Center for Applied 25-7688-4 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(4"Headlap,Nails, Clips)
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services 520191-2-1 TAS 101 March 1999
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
Walker Engineering,Inc. Calculations Two Patty Adhesive Set April 1999
System
Walker Engineering,Inc. Evaluation 25-7183 March 1995
Calculations
Walker Engineering,Inc. Evaluation 25-7094 February 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7496 April 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7584 December 1996
Calculations 25-7804b-8
25-7804-4&5
25-7848-6
Walker Engineering,Inc. Evaluation Restoring Moments Due to February 2007
Calculations Gravity
Nutting Engineers 122 TAS 112 January 2007
.. ... . . . . . ..
. .. . . . . ... .
• • • • • • • • • •
•• • • • • • •• • •
...• , •• ••• �• ••� ••• ExpiraOon Date: 04/26/17
22.02
MIANTY
MI•DADE COU
Approval Date: 04/19/12
•iY i i i •�• i i
Page 3of7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with the applicable Building Code.
4. INSTALLATION
4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance
with Roofing Application Standard RAS 118,RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile Weight-W(lbf) Length-1 (ft) Width-w (ft)
Barcelona 900 11.5 1.417 1.08
Table 2: Aerodynamic Multipliers -X (ft)
Tile A. (ft) X (ft)
Profile Batten Application Direct Deck Application
Barcelona 900 0.289 0.313
Table 3: Restoring Moments due to Gravity-M9 (ft-lbf)
Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or
Profile greater
Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
900 Deck Deck Deck Deck Deck Deck
7.28 8.13 7.21 8.05 7.10 7.93 6.96 7.78 6.79 7.61 6.61 7.40
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... . .
. . . . . . . . . .
. . . . . . .. . .
•• ••
MIAMI•DADE COU NOA No.: 12-0222.02
...� � � � �•• Expiration Date: 04/26/17
Approval Date: 04/19/12
•'• "' Page 4 of 7
. . . . . . . . . .
... . . . ... . .
Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4
1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8
2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3
1 18 Screw 20.7 20.7 18.1
2 48 Screws 43.2 43.2 29.8
1-10d Smooth or Screw Shank Nail 23.1 23.1 19.0
Field Clip)
1-10d Smooth or Screw Shank Nail 29.3 29.3 24.0
Eave Clip)
2-10d Smooth or Screw Shank Nails 27.6 27.6 38.6
Field Clip)
2-10d Smooth or Screw Shank Nails 38.1 38.1 41.8
Eave Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Adhesive 29.3
1 See manufactures component approval for installation requirements.
2 Dow Chemical TileBond Average weight per patty 10.7 grams.
Polyfoam Product, Inc.Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Polyfoam Pol ProTm 66.5
Polyfoam Pol ProTm 38.74
3 Large paddy placement of 63 rams of Pol ProTm.
4 Medium paddy placement of 24 rams of Pol ProTm.
Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Mortar Set Systems
Tile Tile Attachment
Profile .. ... .Application Resistance
Barcelona 900 '. .: ••• Mortar Set 24.5
5. Tile-Tite Roof Tile i0Aortar• •• '
... . ... . .
. . . . . . . . . .
. . . . . . .. . .
•• ••
MAMMADE COON NOA No.: 12-0222.02
Expiration Date: 04/26/17
Approval Date: 04/19/12
••' "' Page 5 of 7
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
detailed below,or following statement: "Miami-Dade County Product Control Approved".
OR
LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... . .
. . . . . . . . . .
:. :.
M"MADE COUNTY ••• • NOA No.: 12-0222.02
I' ... Expiration Date: 04/26/17
Approval Date: 04/19/12
• •;• ; Page 6 of 7
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
PROFILE DRAWING
NAIL HOLES
OVERLOCK
3 5/8
171"
13"
UNDERLOCK `---_—
BARCELONA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
. .. . . . . ... .
•+ + • •• + NOA No.: 12-0222.02
MIAMMADECOUNTW Y "• ' Expiration Date: 04/26/17
• Approval Date: 04/19/12
•Y• • • • • ••" • •
Page 7of7
• • • • • • • • • •
• •• •• • • • •• ••
!
MIAM MIAMI-DADE COUNTY
® PRODUCT CONTROL SECTION
M
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eoy/economy
ICP Adhesives and Sealants,Inc.
12505 NW 44`h Street
Coral Springs,FL.33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset®AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspectiQp at 14c 104 sitC at 1hq request of the Building Official.
This NOA revises NOA l4-08Q5.0%artd tops4tECetpagis 1 through 11.
The submitted documentation wag 18vieWed by Rldk Ttgera.
• •. •.•
• .
. . '�.
0.0• NOA No.: 16-0315.01
MIAMI•DADE COUNTY 000 i . • Expiration Date: 0$/10/17
Approval Date:04/07/16
0:0 . . . . 0:0 . . Page 1 of 11
.
. . . . .....
. . . .
. •• •• . . • •• ..
... . . . ... . .
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset'AH-160 as manufactured by ICP Adhesives and Sealants,Inc. as described
in this Notice of Acceptance.For the locations where the design pressure requirements,as determined by applicable
building code,do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
ICP Adhesives N/A TAS 101 Two component polyurethane foam adhesive
Polyset®AH-160
ICP Adhesives Foam N/A Dispensing Equipment
Dispenser RTF1000
ICP Adhesives ProPack® N/A Dispensing Equipment
30& 100
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset®AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Prope Test Results
Density ASTM D 1622 1.6lbs./ft.'
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft'
Moisture Vapor Transmission ASTM E 96 31 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F.,2 weeks
•" •• +6.0%Volume Change @158°F., 100%Humidity,2
.. ... weeks
Closed Cell Content •• ••: •: %9T&4 b 2gS6 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM teV*wetabds a^atC Subjeet to agrmal manufacturing variation.
•• • • •• • • NOA No.: 16-0315.01
MIAMI•DADE COUNTY • •• • • •• • • •
• ••• Expiration Date: 05/10/17
Approval Date:04/07/16
... . . . . ... . .
Page 2 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset' AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset® AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida AkIrainistrative Code..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... . .
. . . . . . . . . .
• NOA No.: 16-0315.01
.. . . . . . .. . .
MIAMMADE COUNTY •. . •.i ••• Expiration Date: 05/10/17
Approval Date:04/07/16
••• .••
Page 3of11
0.11
. . . . . . . . . .
INSTALLATION:
1. ICP Adhesives Polyset' AH-160 may be used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset®AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120,and ICP Adhesives and Sealants,Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by ICP Adhesives and
Sealants,Inc. ICP Adhesives and Sealants,Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the"A" component and the"B" component shall be maintained between
1.0-1.15 (A): 1.0(B).
6. ICP Adhesives Polyset®AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP
Adhesives ProPack®30& 100 dispensing equipment only.
7. ICP Adhesives Polyset®AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset®AH-160 has been dispensed.
9. ICP Adhesives Polyset®AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details'herein. Each generic tile profile requires the specific placement noted herein.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... . .
. . . . . . . . . .
�' •' NOA No.: 16-0315.01
MIAMI-DAD,COUNTYIE •• • • •. '. Expiration Date: 05/10/17
Approval Date:04/07/16
••• ... Page 4 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq.inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
QMIAMMI-MADEOUNTY
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... . .
. . . . . . . . . .
'• •• NOA No.: 16-0315.01
MIAMMADE COUNTY •.• . •.i . Expiration Date: 0$/10/17
Approval Date: 04/07/16
... ... Page 5 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ADHESIVE PLACEMENT DETAIL# 1
nu+rtrMMOPIMtke.,nt ItddMIs I►T.x Flat/Low Profile Tile
uer« • 1. Starting at the cave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
i paddy onto the underlayment positioned as shown,
V under the strengthening rib closest to the overlock
* 101 � �.._. '� of the tile being set.
Imo• ` �., 2. Continue in same manner. Insure approximately 17
(109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
IftIIit"Webcmem Medium Profile/ Double Pan Tile
iwheftn'W lt&A
Iaytl�.n••c>irII.I 1. Starting at the cave course,apply a minimum 2"
y ,e (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2kLWk% 2. Continue in same manner.Insure approximately 17
(109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
t�E�I�k I�tt tl .�Tihri
High Profile/Single Pan Tile
cr�a..I +s 1. Starting at the cave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
woh. under the pan portion of the tile closest to the
overlock of the tile being set.
a,n 2. Continue in same manner. Insure approximately 17
(109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
/ p—,do
do
00,.�✓ • • 40� Ie• •
twaiws �;n. Caxclasvre
• ••• • ••• • •
• • • • • • • • • •
•• • •• • • NOA No.: 16-0315.01
MIAMI•DADE COUNTY ••• i• °•• :• ••i ••+ Expiration Date: 05/10/17
Approval Date:04/07/16
... . . . . .•. . .
Page 6 of 11
• • • . • . • •
0
.. . . . ... . .
ADHESIVE PLACEMENT DETAIL#2
f•iE p* IL'"Maw Flat/Low Profile Tile
V'OqUrUO
+ ► • 1. Starting at the cave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
`=r` strengthening rib of the tile closest to the overlock of
the the being set. Insure approximately 17 (109.7 cm2)
isterei � • °'•.
23 (148.4 cm2)square inch adhesive contact with the
underside of the tile.
•
2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
.r.am•.. ��' being set.
3. Continue in same manner.Insure approximately 10"
(64.5 cm2)- 12 (77.4 cm'-)square inch adhesive
contact with the underside of the tile.
a.,�t��+•ucM Medium Profile/Double Pan Tile
tw�s� ere�I
pytr,,,•,�a,tp•t 1. Starting at the cave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
the being set.Insure approximately 17(109.7 cm'-)—
3 2 '' 23 (148.4 cm2)square inch adhesive contact with the
1 underside of the tile.
I&I all epdw►•i
-; 2. At the second course,apply a minimum 2"(50.8mm)
x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
.ca.�.• underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
I
3. Continue in same manner.Insure approximately 12"
(77.4 cm2)- 14(90.3 cm2)square inch adhesive
contact with the underside of the tile.
•• ••• • • • • •• (Instructions continued on next page)
• •• • • • • ••• •
•• ••• •• • • • ••
• ••• • ••• • •
• • • • • • • • • •
•• •• • NOA No.: 16-0315.01
MIAMMADE COUNTY ••• i ••• i• ••i ••• Expiration Date: 05/10/17
Approval Date:04/07/16
Page 7 of 11
. . . . . • . . . .
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
�,.�,Q,,..�•ay 1+rld�rltlr�aul�til.�
High Profile/Single Pan Tile
1. Starting at the eave course,apply a minimum 2"(50.8
{ mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
�. onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
the being set.Insure approximately 17(109.7 cm2)—
r lift 23 (148.4 cm2)square inch adhesive contact with the
underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
rte, x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
• underlayment positioned as shown under the pan
low 2 � + portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2) - 19(122.6 cm2)square inch adhesive
contact with the underside of the tile.
I
• . • . . •
00
••• • ••• •
.00 • • • • 000 • •
• • • • • • • • NOA No.: 16-0315.01
•• • • • • • •• • •
M"kDADE COUNTY 00' •• moo •• ' ' • Expiration Date: 05/10/17
Approval Date:04/07/16
••• • • • ••• • •
Page 8 of 11
•%• •• •• • • • •• ••
• • • ••• • •
ADHESIVE PLACEMENT DETAIL##3
MMI through plastic cement Paddy tbetwem tdeo
t.nenregrked► 1. On the eave course only,apply a minimum 2" (50.8
sanemaptimal mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy
° vaadytudertilei onto the underlayment positioned as shown,under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
4:4im 16,�`�, to the overlock of the the being set.Leave
approximately 4" (10 1.6 mm)up from the eave
s pMdy y`` edge free of foam to prevent the expanded adhesive
z4&'- from blocking the weep holes. Insure
approximately 17-23 int(109.7-148.4 cm2)of
10 .,,t adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x V (25.4
mm)foam paddy onto the underlayment just below
RaMowPm ileTile the second course line positioned foam paddy
under the strengthening rib for flat tile,or under the
Nafl t�pl ie
ccament SMgpaddyunderSe pan portion of the tile,closest to the underlock for
twhePa (betwem fled the second course tile to be installed. Insure
approximately 8-9 int(51.6-58.1 cm2)of adhesive
Paadytundertlet contact with the underside of the tile.
mat
an
(Instructions continued on nextpage)
4X41n. s4bf.` �
S"Ie.p�nrent-
0 2 in.
Eave Closure
Eave eourm Fascia
Medium ProflieTlle
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... . .
. . . . . . . . . .
• •• NOA No.: 16-0315.01
QML"MAMMPED��XADM :' '.' ;' ..: '.' Expiration Date: 05/10/17
Approval Date:04/07/16
... ... Page 9 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ADHESIVE PLACEMENT DETAIL#3 (CONTINUED)
t �pa"MAN tike
todmfegraireel 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x3/4
t4ddl'tbet�cnttles3 (19 mm)paddy on top of the eave course tile
eanets RaddytaeMertilRl surface as shown,on top of the strengthening rib
for flat tile or on top of the pan portion of the rile,
closest to the underlock of the first course of tile.
Install second course of tile.Insure approximately
�4X41n. 9(58.1 cm2) - 11 (71cm2)square inch adhesive
214 -,, ' � contact with the underside of the tile at the overlap
P�W and 7(45.2 cm2)-9(58.1 cm)square inch
top oftoo adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
Ease coarse
A
Difpodp
lllgfl prolene
•Y ••• • • • • • ••
• •• • • • • ••• •
•• ••• •• • • • ••
• ••• • ••• • •
• • • • • • • • • •
•• NOA No.: 16-0315.01
. .. . . .. . . .
MIAMI•DAD;COUNTY ••• Expiration Date: 05/10/17
Approval Date:04/07/16
••• ..• Page 10 of 11
. . . . . • . . . .
. .. .. . . . .. ..
... . . . .•. . .
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel (Cap and Pan)Tile
1. Starting at the eave course,apply a minimum 2"
t)Place enough adhesive to achieve 65 to 70 sq.in. Steep pitch tions
in contact with the pantile. (when required)red) (50.8 mm)x 10"\254 mm)x 1"(25.4 mm)foam
2)Tum covers upside down.Place adhesive in paddy onto the underlayment positioned as
to t in.from outside edge of cover tile. shown under two adjacent pan tiles. Support cave
Then install the tilt.Ensure 20 to
2s sq.in.contact area. tiles from rocking until adhesive has a chance to
IUnderlayment � cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2)—70(451.6 cmz)
square inch adhesive contact with the underside
Sheathing of the pan tile.
Eave closure
(motarshown) 3. Tum covers upside down exposing the underside
Weephole Fascia Board of the tile.Apply a minimum 1"(25.4 nun)x 10"
(254 mm)bead of adhesive directly on the inner
Remove top portion of the eave course cover tile.Abut to second course of edge of each side of the cover tile.Leave
pan tiles.Ensure eave end of pan and cover tiles are flush at save line. approximately 3/4"(19 mm)to 1"(25.4 mm)
Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward,free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course.Insure a minimum of
20(129 cm2)-25 (161.3 cm2)square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner.Trim away
any cured exposed foam adhesive.Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required,2"(50.8
mm)x 4"(101.6 mm)nailers or the tie wire
system using galvanized, stainless steel,or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
.. ... . . . . . ..
NOA No.: 16-0315.01
MIAMMAD'COUNTY a 0' '•• �' 000 •e Expiration Date: 05/10/17
Approval Date:04/07/16
••• • • J • • • • • Page 11 of 11
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • 0
x.
1L A,ARESOjs
,T
Lp
.. . . . . . ••• ••
0.0
owe
••• . •••
60,
• • Y • • . •
• •• • • •• •
0001137305 •.• ••
• • •:• • u • • •••
• • • • • • • • • •
• • ••• • • • •••
R