RC-16-128 Perm, it NO. RF-1-16-128
`y -:.!R Miami Shores Village Permit Type: Roof
10050 N.E.2nd Avenue NW
It Work Classification:Tile
Miami Shores,FL 33138-0000 'Per
Permit Status:APPROVED
Phone: (305)795-2204
F�ORIOp'
Issue Date: 1128/2016 Expiration: 07/26/2016
Project Address Parcel Number Applicant
11004 NW 2 Avenue 1121360020240
Miami Shores, FL 33168- Block: Lot: LSP HOMES LLC
Owner Information Address Phone Cell
LSP HOMES LLC 455 NE 210 Circle Terrace (305)527-3643
MIAMI FL 33179-
455 NE 210 Circle Terrace
MIAMI FL 33179-
Contractor(s) Phone Cell Phone
Valuation: $ 24,500.00
KDF CONSTRUCTION INC
(305)244-8781
_ r...�.»...... .. ..., Total Sq Feet: 2600
Type of Work:Re Roof Available Inspections:
Additional Info:ROOF TILE COLOR THRU TERRACOTTA Inspection Type:
Classification:Residential Up Lift Report
Scanning:4
Tin Cap
Final Roof
Tile In Progress
Renailing Affidavit
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $15.00
Invoice# RF-1-16-58360
DBPR Fee $4.50
DCA Fee $4.50 09/26/2015 Credit Card $50.00 $311.00
Education Surcharge $5.00 01/28/2016 Credit Card $311.00 $0.00
Permit F$e New Roof $300.00
Scanning Fee $12.00
Technology Fee $20.00
Total
-
,y $361.00
M�
na
:X
C,
:x
a
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertain in `thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
acce tin�tllis permit I sume responsibility for all work done b either myself, m agent, servants, or employes. I understand that separate permits are
P 9� p P Y Y Y Y 9P
required fo�'ELECTRI L,PLUMB MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS?i4FF IT: I certi that II the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
constru ion' oning. Fut erm , I authorize the above-named contractor to do the work stated.
January 28, 2016
A thorized Sig a ure:Owner / Applicant / Contractor / Agent Date
Building Department Copy
January 28, 2016 1
40
ACB2 Engineering Inc.
Testing & Engineering Services
Certification of Authorization#8131 Roof Tile Uplift Test Report
Tel: 954-245.8976; Fax: 954.301.7776
5230 NE 18 Avenue
Fort Lauderdale, FL 33334
Attention: Miami Shores Village, Building Division,
10050 NE 2"d Avenue, Miami Shores, FL 33138
Client: KDF Construction P_�c 15_ ZOO
Test Date: 07/21/2016 Permit# RF-16-128
Property Address: 11004 NW 2"d Avenue, Miami Shores, FL
Roof Pitch: Type of Tile: Roof Area:
4 in 12 Boral Roof Tile 26.00 squares
Tile Attachment Method: Two Component Polyurethane Foam Adhesive-Poly Pro H 160
Field Instrument : IMADA Force Gauge 0-100 Serial number:243454
Test Location Total Number of Tests Field Uplift Pull Test Test results
Perimeter Area: 10.00 sq. 10 As per FBC 2014 Passed
Field Area: 16.00 sq. 16 As per FBC 2014 Passed
No.of Corner: 7 7 As per FBC 2014 Passed
Ridge Areas: 190 PCs. 19 As per FBC 2014 Passed
Important.
These laboratory results can change due to future weather impacts and/or unavoidable roof
traffic.Therefore,this report represents the TAS 106 results at the time of the test.
Please see attached a Roof Sketch for this project.
Cordially,
AC132 Engi a ri g Inc. (NOA 09-1005.01)
Anto edo, PE
Fla. Reg. o: 36466
6�- 1 Jz o c�
1
ACB2 Engineering Inc.
Engineering and Laboratory Services
5230 NE I e-Avenue
Fort Lauderdale, Florida 33334
Phone: (954) 245-8976 Fax: (954) 301-7776 ,
-. T
r T I
� r
_ r
Miami Shores Villagec ::j ,� �.
Building Department JAN'15 2016
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
LB4Y: aJW
Tel:(305)795-2204 Fax: (305) 756-8972 r
INSPECTION LINE PHONE NUMBER: (305)762-4949
FBC 20AI-
BUILDING Master Permit No. ee A%2L02
PERMIT APPLICATION Sub Permit NoAE J - /2,4r.
❑BUILDING ❑ ELECTRIC XROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING [--] MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 1100� NW Z pvv
City: Miami Shores County: Miami Dade Zip- R31( Lg?
Folio/Pa//rcel#: ' a 13(Q--oo Z—O Zip Is the Building Historically Designated:Yes NO
Occupa�hcy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name(Fee Simple Titleholder): LSP k9l e-C Phone#:
Address: C(e
City:_k lsli j. State: Zip: 331
r
Tenant/Lessee Name: Phone#:
Email: '�� � 7 1 "LQ)
i
CONTRACTOR:Company Name: �� �w 6'1(`uc,"�c ov` t a C Phone#: 313,V p2 d i
Address: ���� ��r�r:c_�„� i��.rc .t
City: ; �. .//c,y ( State: Ip 1. Zip:
Qualifier Name: �lC'�1k, " phone#:
State Certification or Registration#: � 1 1�Z7F 6'0 Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
�,,—,J--
Value of Work for this Permit:$ `tel �ew
Square/Linear Footage of Work: .2Gt7C-)Type of Work: ❑ Addition ❑ Alteration ❑ Repair/Replace ~r ❑ Demolition
Description of Work: &icmc
Specify color of color thru tile:
Submittal Fee$ Permit Fee$ 300 G�\ CCF$ ' "�1 CO/CC$�y
Scanning Fee$ 1 2 •(50 c
Radon Fee$ -o' 53 DBPR$ ( • rJ� Notary$ 50
Technology Fee$ 2_y • 6�) Training/Education Fee$ •q Double Fee$ (77
Structural Reviews$ Bond$ P
TOTAL FEE NOW DUE$ '9(o 00
(Revised02/24/2014)
% v w
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING, SIGNS,
WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not ea roved and a reinspection fee will be charged. R
Signature Signature
-/e!�
Owner or gent Contractor
The foregoing instrument was acknowledged before me this The foregoing instru1ment wassacknowledged before m�'is
day of k " ,20�,by s day of /� k-5 201 by
who is personally known to me or who has produced 16L- who is personally known to me or who has produced d l-
As identification and who did take an oath. as identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign: A, 2�1 -A
Print: J rPrint:
My Commission Expires: ;) JAMIE JENKINS My Commission Expires: JAMIE JENKINS
MY COMMISSION#FF009945
MY COMMISSION#FF009945 EXPIRES:A 21,2017
EXPIRES:April 21,2017
APPROVED BY ` fv Plans
Examiner Zoning
Structural Review Clerk
(Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
0
IR culVE—f
Florida Building Code 5th Edition (2014)
JAN 15 2016 1
High-Velocity Hurricane Zone Uniform Permit Application
1
Section A(General Information) 1
1
Florida Blend Process No. 1
1HBCS3903 STANDARD
1
1
w
I
1l, ROOF CATEGORY 1
❑ Mechanically Fastened Tile R/Mortar/Adhesive Set Tiles 1
❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes 1
1
❑ Prescriptive BUR-RAS 150 1
V ROOF TYPE 1
❑ Maintenance ❑ Reroofing ❑ Recovering 1
In Stock in Lake Wales and Pompano ROOF SYSTEM INFORMATION 1
Steep Sloped Roof AREA(SSF) Z6 Total
uvo(� 1
Section B (Roof Plan) 1
sections, roof drains, scuppers,overflow scuppers and overflow drains. Include dimen- 1
The printed colors shown in this brochure may vary from fy dimensions of elevated pressure zones and location of parapets.
1
1
1
1
1
Z 1
o F 1
5CY
1
� � 1
�t 1
` ( Q 1
W ' 1
-c U
U) x 1
a
0 w lt—
. . . . .
UJ CLL z W
[L Q m (�� 1
. . . . . . . . . .
. .. .. . . . .. ..
FLORIDA BUILDING CODE—BUILDING,5th EDITION(2014) "' ' • • ••• • •
15.37
Copyright to,or licensed by,ICC(ALL RIGHTS RESERVED);accessed by Eliezer Palacio on]un 8,2015 10:32:12 AM pursuant to License
Agreement.No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition(2014)
High-Velocity Hurricane Zone Uniform Permit Application Form 1
1
Section D(Steep Sloped Roof System)
/ 1
Roof System Manufacturer:
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): a 1
P1: R? P1: P1: Z
1
1
Deck T 1
YPe�
1
Type Underlayment: 1
Roof Slope: �
12 Insulation: 71
1
Fire Barrier:
1
1
Ridge Ventilation? Fastener Type &Spacing: / ry
Adhesive Type: D�Y�S
1
Type Cap Sheet: bS U 1
1
Mean Roof Height: S Roof Covering: Cph bb71
1
Type&Size Drip
&Edge: 1
djV '
1
.. ... . . . . . ..
. .. . . . . ... .
.. ... . .. . . . ..
.. . . .. . . . . .
. .. . .. .. . .
... . . . . ... . .
. . . . . . . . . .
. .. .. . . . .. ..
FLORIDA BUILDING CODE—BUILDING,5th EDITION(2014) ' ' "• • •
15.39
Copyright to,or licensed by,ICC(ALL RIGHTS RESERVED);accessed by Eliezer Palacio on Jun 8,2015 10:32:12 AM pursuant to License
Agreement.No further reproductions authorized.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code 5th Edition(2014)
1
1 High-Velocity Hurricane Zone Uniform Permit Application Form.
1
1
1 Section E(Tile Calculations)
1 For Moment based tile systems,choose either Method 1 or 2. Compare the values for Mr with the values from M,. If the M,values
are greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable.
1
1 Method 1 "Moment Based Tile Calculations Per RAS 127"
1 (P1: x =i2�-Mg: =Mr, Product Approval M, y,3
1 (P2:�xX a�=2Z_ )_Mg =M2 Product Approval Mf ,Z •3
1 (P3: yxX,3C�_ Z -Mg.'7'=Mr,25.66 Product Approval M, 1-
1 Method 2"Simplified Tile Calculations Per Table Below"
1 Required Moment of Resistance(Mr)From Table Below Product Approval M,
1 Mr required Moment Resistance'
1 Mean Roof Height
1 Roof Slope 15' 20' 25' 30' 40'
1 2:12 34.4 36.5 38.2 39.7 42.2
1 3:12 32.2 34.4 36.0 37.4 39.8
1 4:12 30.4 32.2 33.8 35.1 37.3
1 5:12 28.4 30.1 31.6 32.8 34.9
1 6:12 26.4 28.0 29.4 30.5 32.4
1 7:12 24.4 25.9 27.1 28.2 30.0
1 'Must be used in conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and
1 Appeals.
1 For Uplift based tile systems use Method 3. Compared the values for F'with the values for Fr. If the F'values are greater than or
1 equal to the Fr values,for each area of the roof,then the tile attachment method is acceptable.
1
1 Method 3"Uplift Based Tile Calculations Per RAS 127"
(P1: x L -- x w:_ )-W: x cos 8 =Fr, Product Approval F'
1 (P2: x L = x w:= )-W: x cos 0 =F2 Product Approval F'
1 (P3: x L = x w:= )-W: x cos 6 =F,, Product Approval F'
1
1 Where to Obtain Information
1 Description Symbol Where to find
1 Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis pre-
pared by PE based on ASCE 7
1 Mean Roof Height H Job Site
1 Roof Slope 8 Job Site
i Aerodynamic Multiplier Product Approval
1 Restoring Moment due to Gravity Mg Product Approval .. ... ..
1 Attachment Resistance Mf Product Approval.• •; •• ••
1 Required Moment Resistance M9 Calculated .. ... .. ..
1 Minimum Attachment Resistance F' Product Approval
1 Required Uplift Resistance Fr Calculated ... ... ...
1 Average Tile Weight W Product Appro ft: ••• • 0
1 Tile Dimensions L =length W=width Product Approval ... .
1 All calculations must be submitted to the building official at the time of permit application.
1 ... . . . . ...
• • . • • • . • • •
• •• .. . . . .. ..
15.40 FLORIDA BUILDING CODE-- Ko 5th WndN(2014)
IA
I t 1111
1 ' Copyright to,or licensed by,ICC(ALL RIGHTS RESERVED);accessed by Eliezer Palacio on Jun 8,2015 10:32:12 AM pursuant to License
Agreement.No further reproductions authorized.
k
�,StlKpFS`�
�<ORID�
SECTION 1524
HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
1524.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with
the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402
govern the minimum requirements and standards of the industry for roofing system installations.Additionally,the
following items should be addressed as part of the agreement between the owner ant the contractor. The owner's
initial in the designated space indicates that the item has been explained.
2. 4 Renailing wood decks:When replacing roofing,the existing wood roof deck may have to
be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually
concealed prior to removing the existing roof system).
4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance;therefore,
roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of
maintaining the appearance.
6. ` Overflow scupperswall outlets): It is required( ) q d that rainwater flows off so that the roof is
not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this
discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow
scuppers in accordance with the requirements of Sections R4402, R4403 and R4413.
3 /s 3Zv A,
Owner/Agent' Sig at D to Contractor Signature Date
116y!Z Nw Z.u4L—{ n f.rM �kcveJ
Property Address Permit Number
Revised on 7/9/2009 LD;07/01/2015;
•• ••• • • • • • ••
•• ••• •• • • • ••
• ••• • ••• ••• •
•• • • •• • • • • •
000 • • • • 000 • •
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • 0
Miami shores Village
� Building Department
hEeNr 1— 10050 N.E.2nd Avenue
�t0RlpA Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date:
10050 NE 2nd Ave
Miami Shores, A 33138
Re: Owner's Name:
Property Address: /l voLj Nw 2.--d A-v-c
Roofing Permit Number:
Dear Building Official:
IV --s CCC s certify that I am not required to retrofit the roof to wall connections of my
building because:
o The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
Z1994n of the South Florida Building Code (1994 SFBC)
4,L-, s
Signature Print Nam
State of Florida •�
County of Dade •• .
. .. . . . . ... .
The undersigned, being the first duly sworn, deposes and says that he/s a is the owner for the above property mentioned.
Sworn to and subscribed before me this -LY-day of •. •ZQk Q:1;• •; •••
Notary Public, Sate of Florida at L ,= Notary Public-State of Florid
-My CorrmiEziir�s•J�n 6,20il
Commiaslen# F 136sa8
• When the just valuation of a struct purpose of ad valorem taxation is equal to or more than$300, a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.• • •• •
Revised on 5/21/2009
5 °R� Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
��ORIDp Tel: (305) 795.2204
Fax: (305) 756.8972
AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION
RETROFIT FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT
TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date:
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: Z_ 4LO n1�e s L L C
Property Address: 11M Y IV AI ,9- 14V' F,
Roofing Permit Number:
Dear Building Official: JJ /
certify that I have improved the roof to wall connections of the referenced
property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site-Built Single Family Residential
Structures as adopted by the Florida Building Commission by Rule 913-3.047 F.A.C.
rr����Signature Print Print Name
State of Florida
County of Dade
The undersigned,being the first duly swom,deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this 'ZD day of /0 r< <
Notary Public, Sate of Florida at Large4
KJAMIEJENKINS
(SEAL) MMISSION#FFDO9945I .Apn12I,2°" FINAL COMPLIANCE
Revised on 3/21009 �:' : ; ; • ••• • •
MIAMI.
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/aera
Boral Roofing,LLC
7575 Irvine Center Drive,Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance,if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barcelona 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the man4facturer os it Mtriliutpr%and
shall be available for inspection at the job site at the request of the Building Official. g. �: ; : : : � •*. •
• .
• . : *go
This renews and revises NOA#07-0220.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera. 0:9 •. •
MIAM6DADE :NOA Np.: 11-0122.42
COUNTY y'
� �• Expiratiotl�ate�04/26/x'1
Approval Date: 04/19/12
• .%
ROOFING ASSEMBLY APPROVAL
Category Roofing
Sub-Category: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral
Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where
the pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in the
installation section herein. The attachment calculations shall be done as a moment based system..
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Barcelona 900 1= 17" TAS 112 High profile,interlocking,one-piece,'S'
w= 13" shaped,high-pressure extruded concrete roof
Y2"thick tile equipped with three nail holes. For direct
deck or battened nail-on,mechanically
fastened,mortar set or adhesive set
applications.
Trim Pieces Length: varies TAS-112 Accessory trim,boosted Barcelona,concrete
Width:varies roof pieces for use at hips,rakes,ridges and
varying thickness valley terminations manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
2.1.1. Lake Wales,FL.
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102&TAS 102(A)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix II TAS 108(Nail-On)
Redland Technologies P0402 Withdrawal Resistance Sept. 1993
• • • •.. Testing of screw vs. smooth
".
•. shank nails
.••Ite(tasd TdtAo6@ies•• Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108(Nail-On)
• NOA No.: 12-0222.02
. D�► couNsV ••• Expiration Date: 04/26/17
. .
• Approval Date: 04/19/12
• ••• Page 2 of 7
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108(Mortar Set)
Professional Service Industries, IC-1320-94 Physical Properties Feb. 1995
Inc. TAS 112
The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996
Engineering,Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996
The Center for Applied 25-7688-5 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(3"Headlap,Nails,Direct
Deck,New Construction)
The Center for Applied 25-7688-4 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(4"Headlap,Nails,Clips)
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services 520191-2-1 TAS 101 March 1999
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
Walker Engineering,Inc. Calculations Two Patty Adhesive Set April 1999
System
Walker Engineering,Inc. Evaluation 25-7183 March 1995
Calculations
Walker Engineering,Inc. Evaluation 25-7094 February 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7496 April 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7584 December 1996
Calculations 25-7804b-8
25-7804-4&5
25-7848-6
Walker Engineering,Inc. Evaluation Restoring Moments Due to February 2007
Calculations Gravity
Nutting Engineers 122 TAS 112 January 2007
•
•• •-N6A M.: ]:?,,0222.f j
MIAMI-DAD'C,OUNTW0ExpirationVate! 04/26/17 •••
Approval Date: 04/19/12
';• �Psg4&3pf 7 •
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with the applicable Building Code.
4. INSTALLATION
4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance
with Roofing Application Standard RAS 118,RAS 119,and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W) and Dimensions (I x w)
Tile Profile Weight-W(Ibf) Length-I (ft) Width-w (ft)
Barcelona 900 11.5 1.417 1.08
Table 2: Aerodynamic Multipliers -1 (ft)
Tile X(ft ) (ft )
Profile Batten Application Direct Deck Application
Barcelona 900 0.289 0.313
Table 3: Restoring Moments due to Gravity-M9 (ft-lbf)
Tile 2":12" 3"•12" 4"•12" 5":12" 6"•12" 7":12" or
Profile greater
Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
900 Deck Deck Deck Deck Deck Deck
7.28 8.13 7.21 8.05 7.10 7.93 6.96 7.78 6.79 7.61 6.61 7.40
goo
�•�
• •• NOA No.: 12-0222.02
tin =OUN • Expiration Date: 04/26/17
' Approval Date: 04/19/12
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-lbf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4
1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8
2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3
1 .#8 Screw 20.7 20.7 18.1
2 .#8 Screws 43.2 43.2 29.8
1-10d Smooth or Screw Shank Nail 23.1 23.1 19.0
Field Clip)
1-10d Smooth or Screw Shank Nail 29.3 29.3 24.0
Eave Clip)
2-10d Smooth or Screw Shank Nails 27.6 27.6 38.6
Field Clip)
2-10d Smooth or Screw Shank Nails 38.1 38.1 41.8
Eave Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-lbf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Adhesive 29.3
1 See manufactures component approval for installation requirements.
2 Dow Chemical TileBond Average weight per patty 10.7 grams.
Polyfoam Product, Inc.Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Polyfoam Pol Pro rm 66.5
Polyfoam Pol ProTm 38.7
3 Large paddy placement of 63 rams of Pol Pro TM.
4 Medium paddy placement of 24 rams of Pol Pro TM'.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar Set Systems
Tile Tile Attachment
Profile Application .. ...Fje%istpncp.
Barcelona 900 Mortar Set .; 24:5. ;�; ••
5. Tile-Tite Roof Tile Mortar •• ••• •• ..
. ... . ••• ••• •
•: :. to!No.: dk2Z212
MIAMI•DADE COU ' ' Expiration Date:004/26/17
Approval Date: 04/19/12
••• ... Page S of 7
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
detailed below,or following statement: "Miami-Dade County Product Control Approved".
LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
.. . . . . . ... ..
. ... . . . . % .
.. . . . .. ... ..
. ... ... . ... .
• •• NOA No.: 12-0222.02
M im •OVEI) • ••• Expiration Date: 04/26/17
Approval Date: 04/19/12
• ••• ... Page 6 of 7
. . . . . . . . . .
.. .. . . . .. .. .
. . ... . . . ...
PROFILE DRAWING
NAIL HOLES
OVERLOCK
�`�,-. 3/5!8'
17
.�'
~� 13"
UNDERLOCK
BARCELONA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
. .. . . . . ... .
.. ... .. . . . ..
. o v . ... ... .
..' ATOl No.: d4212.212
MIAMI•DAD;COUNTY Expiration Date: 04/29/17
Approval Date: 04/19/12
"• ••• ;age I of 7
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
. t
MIAMKXedX
R711111111111w MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy
Polyglass USA Inc.
150 Lyon Drive
Fernley,NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the rpttAufaqu;er;o;its distrb4Amrs and
shall be available for inspection at the job site at the request of the Building Official.
... ... .. . . . ..
This revises NOA#11-1229.01 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
. ... . ... ... .
.. . . .. . . . . .
. .. . .. .. . .
NOA No.: 12-0713.02
rluu MADECOUNW *EepivatioaDate: 09/13/16
e pprroval Date: 02/14/13
• •• •• • • :-*-Page 1 of 8
... . . . ... . .
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Category: Underlayment
Material: SBS ,APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick MTS Roll: TAS 103 A homogeneous,rubberized asphalt
underlayment 65'8"x 3'33/8" waterproofing membrane,glass fiber reinforced
Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for
#2 use as an underlayment for metal roofing,roof
tile, slate tiles and shingle underlayment.
Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering,
underlayment 65' x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced,
Manufacturing Location Or 65' x 3' bituminous sheet material for use as an
#1  60 mils thick underlayment in sloped roof assemblies.
Designed as an ice&rain shield and as a flat
roof tile underlayment.
Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering,APP
underlayment 32'10"x 3'33/8" ASTM D 1970 polymer modified, fiberglass or polyester
Manufacturing Location 100 mils thick reinforced,bituminous sheet material for use as
#1  an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering,glass-
underlayment 65' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing
(Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof
Manufacturing Location tile underlayment.
#1 
Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane,
underlayment 32'10"x 3'33/8" ASTM D 1970 glass-fiber/polyester reinforced,with a granular
Manufacturing Location 130 mils thick surface designed for use as a tile roof
#2 underlayment.
Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-adhering,glass-
Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and roof
tile underlayment.
.. . . . . ... ..
Polystick Dua�ii Rolf: TAS 103 and A rubberized asphalt self-adhering,glass-
Manufacturing LGocart101t•• ¢I•x!j'� 3/g" ASTM D 1970 fiber/polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and
roof tile underlayment.
. . . . . .. . . ..
. . .. .. . .. .
E COUNTY
NOA No.: 12-0713.02
MIAM4DiAD
.. D Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 2 of 8
. . . . . . . . . .
.. .. . . . .. .. .
. . ... . . . ...
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick TU Max Roll: TAS 103 and A rubberized asphalt self-adhering,polyester
Manufacturing Location 65'8"x3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed
#2 60 mils thick as a a roof tile underlayment.
MANUFACTURING PLANTS:
1.Hazelton,PA
2.Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Exterior Research&Design,LLC 11756.04.01-1 TAS 103 04/27/01
11756.08.01-1 ASTM D 1970 08/14/01
02202.08.05 TAS 103 08/29/05
Trinity I ERD P5110.08.07 TAS 103 08/29/07
P10870.09.08-R1 TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798 &G 15 5 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11
P40390.08.12-1 TAS 103 &TAS 110 08/06/12
P40390.08.12-2 ASTM D 1623 08/07/12
P40390.10.12 ASTM D 1970 10/03/12
PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02
PUSA-005-02-01 ASTM D 4977 01/31/02
PUSA-018-02-01 ASTM D 2523 07/14/03
PUSA-035-02-01 TAS 103 09/29/06
PUSA-033-02-01 ASTM D 1970 01/12/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-083-02-01 TAS 103 06/30/08
PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09
Momentum Technologies,Inc. JX20117A TAS 103/ASTM D4798 &G155 04/01/08
RX14E8A TAS 103/ASTM D4798 &G155 11/09/09
DX23D813 TAS 103/ASTM D4798&G155 02/18/10
DX23138A TAS 103/ASTM D4798&G155 02/18/10
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
.. . . .. . . . . .
. .. . .. .. . .
NOA No.: 12-0713.02
M AMMADE CourrrY ••• •EapiYslion Date 09/13/16
•App rovA Date: 02/14/13
•� •�• •jage3of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood,non-insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4"head lap. (for
base sheet only)
Membrane: Polystick membranes self-adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'h"and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications,center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6"piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
.. . . . . . ... ..
. ... . . . . .. .
.. . . . .. ... ..
. ... ... . ... .
. . . . . .. . . ..
. . .. .. . .. .
E COUNTY NOA No.: 12-0713.02
PR MIAMFQAD
D Expiration Date: 09/13/16
. Approval Date: 02/14/13
. : Page 4 of 8
.. .. . . . .. .. .
. . .% . . . ...
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS,TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles,wood shakes and shingles,
non-structural metal roofing,roof tile systems and quarry slate roof assemblies.Polystick IR-Xe,TU,and TU
P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in
roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth,clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Ex osure Limitations(days)
MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro TU Max
Winter Haven,FL. 180 180 180 180 180 180 180 90
Hazelton,PA. N/A 30 30 180 N/A N/A N/A N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU,TU Plus,Tile Pro and TU Max may be used in both
adhesive set and mechanically fastened roof tile applications. Polystick IR-Xe, and Dual Pro are limited to
mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens
roof tile applications.Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for(direct-to-deck)tile assemblies shall be as
follows: (See Table Below)
Tile Profile Polystick MTS Polystick IR-Xe Polystick TU,TU Polystick TU
Plus,TU P,Tile Max
Pro
Flat Tile Prohibited without 5:12 No limitation No limitation
battens
Profiled Tile Prohibited without Prohibited No limitation No limitation
battens
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
.. . . .. . . . . .
. .. . .. .. . .
NOA No.: 12-0713.02
tau NIODecouNrir .�. *ExpirntionDato: 09/13/16
4pp;oval Date: 02/14/13
•�• �• •� ••• •:• :• •Fage5of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
s
t i
Roofing Tiles
3 (6 Max.Per Stack)
CX rF12
6
fcof Deck prepared vAn
PO LYSECK TU P{a
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products.Polystick MTS,IR-Xe,TU,TU Plus,TU P,TU Max,Dual Pro and
Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS,IR-Xe,
TU, TU Plus,TU P,TU Max,Dual Pro and Tile Pro as a component part of an assembly in the Notice of
Acceptance. If Polystick MTS, IR-Xe,TU,TU Plus,TU P, TU Max,Dual Pro and Tile Pro is not listed,a
request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control
Department for approval provided that appropriate documentation is provided to detail compatibility of the
products,wind uplift resistance,and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control
Approved" or the Miami-Dade County Product Control Seal as shown below.
MIAMI•DADE COUNTY
...• 9
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1.This Notice of Acceptance.
2.Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
. ... . . . . .. .
.. . . . .. ... ..
. 0:0 •.• . ... .
. . . . . .. . . ..
MIAMNOA No.: 12-0713.02
MDADE COUNTY
•••. Expiration Date: 09/13/16
Approval Date: 02/14/13
. Page 6 of 8
.. .. . . . .. .. .
. . ... . . . ...
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls,with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type,applied with a minimum 1"metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions,at a minimum rate of
12"o.c. Polystick TU Plus should be back nailed in designated area marked"nail area,area para clavar"on
the face of membrane,with the above stated nails and/or disks. The head lap membrane is to cover the area
being back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6"wide,uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement,applied in between the application of the lap. The use of mastic
between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens,as required by the tile manufacturers NOA's,must be used on all projects for
pitch/slopes of 7712"or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12",precautions
should be taken,such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
8. Polystick membranes may not be used in any exposed application such as crickets,exposed valleys,or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement,Polyglass Polyplus 50 Premium MB Flashing Cement,Polyglass PG500 MB Flashing
Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set
and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6
inches in either direction. The repair should be installed in such a way so that water will run parallel to or
over the top of all laps of the patch.
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry,clean and properly prepared,before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance(NOA)approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894-4563.
.. ... .. . . . ..
. •.• . •.• •.• .
.. . . .. . . . . .
.. % .. . .
.. . •.• •
NOA No.: 12-0713.02
MIAMKxM E COUNTY ••• • • •FA kation Date: 09/13/16
ffjzuoymj�' •X �ov&1 Date: 02/14/13
Ply; % * gage 7 of 8
•.• • 0 0 •11• 0 0
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 8944563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association(NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
.. . . . . . ... ..
. ... . . . . .. .
.. . . . .. ... ..
. ... ... . ... .
. .
..• •
.. . . . . . .. . .
. . .. .. . .. .
NOA No.: 12-0713.02
MIAMFQADE COUNTY
. I. • • • • ••• Expiration Date: 09/13/16
• • Approval Date: 02/14/13
• • •••• Page 8 of 8
• • . • . • • . •
MIAME MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Qov/economy
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN.55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3MTM 2-Component Foam Roof Tile Adhesive AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Offici%lp• ••: .0. .00
This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. • •• ••• •
.. ... .. • . • .•
The submitted documentation was reviewed by Alex Tigera.
0 eoo�
•: :• • •: L3X N:A 12-4805.01
rw►MFor►ne Coow"
•Yxpiration Date: 15/10/17
Approval Date:09/04/14
•.• • • • , ••• • Pape 1 of 11
• • •
•• • : 00 .:
• . • • • • ••
• ••
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTm 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in this Notice of Acceptance. For the locations where the design pressure requirements,as determined by
applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using 2-Component
Foam Roof Tile Adhesive AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2-Component N/A TAS 101 Two component polyurethane foam adhesive
Foam Roof Tile Adhesive
AH-160
Foam Dispenser N/A Dispensing Equipment
RTF1000
ProPack®30& 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Proper Test Results
Density ASTM D 1622 1.6 lbs./ft.'
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Ft2
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F., 2 weeks
•• • • • • ••• •• +6.0%Volume Change @1580F., 100%Humidity,2
• • • • • • • weeks
Closed Col Cpterj ; ;•; ;• ••• ASTM D 2856 86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
Mw 4 D co NT i•• • •: :•• NOA No.: 14-0805.01
APPRUED
••• • •• Expiration Date: 05/10/17
Approval Date:09/04/14
• • ••• • • • ••• Page 2 of 11
• • • • • • • • • •
•• •• • • • •• •• •
• • ••• • • • •••
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-1 PA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories,Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
P36700.04.12 ASTM D 1623 04/18/12
P39740.02.12 TAS 101 02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat,low,&high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3M"2-Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code. •• ••• ••
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
•: :. :. NdA 1 o. 14-0805.01
MMWDADE COUNTY • • expiration Date: 05/10/17
Approval Date: 09/04/14
••• ••• Page 3 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-
160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County
Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120,and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the"B"component shall be maintained between 1.0-1.15 (A): 1.0
(B).
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF1000 or
ProPack®30& 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive.Tile must be set within 1 to 2 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in
accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted
herein.
.. . . . . . ... ..
. ... . . . . .. .
.. . . . .. ... ..
. ... ... . ... .
' NOA No.: 14-0805.01
MIAMF i i' ' •i i'
JAPPROVED[7 ... .. Expiration Date: 05/10/17
Approval Date:09/04/14
. . ... . . . . ...
Page 4 of 11
. . . . . . . . . .
.. .. . . . .. .. .
. . ... . . . ...
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram
Area Weight
Eave Course-Flat,Low,High All Eave Course 17-23 sq.inches 45-65
Profiles
Flat,Low,High Profiles #1 17-23 sq. inches 45-65
Flat Profile #2 10-12 sq. inches 30
Low Profile #2 12-14 sq. inches 30
High Profile #2 17-19 sq. inches 30
Flat,Low,High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-Piece Barrel(Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead
edge)20-25 sq. inches each
bead
Two Piece Barrel(Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-
Dade County Product Control Seal as shown below.
MIAMI�ADE COUNTY
APPROVED[
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
•: :. •: :. •N!lso.i 14-0805.01
MIAMFDWDE COUNTY •• • ••• expiration Date: 05/10/17
Approval Date: 09/04/14
••• ••• Page 5 of 11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ADHESIVE PLACEMENT DETAIL# 1
Mar thmMit plank cairimt caddy 184namh M) Flat/Low Profile Tile
(wim required) /i
to
und•rt.ym•nt 1. Starting at the eave course,apply a minimum 2"
'`,• 'i (50.8 mm)x 10"(254 mm)x 1"(25.4 mm) foam
';.� paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
�•,y loi�i ti..
of the the being set.
ttrtt•rrf options ,/ " -
Eav:Cours•
2. Continue in same manner. Insure approximately 17
(109.7 cm)—23 (148.4 cm2)square inch adhesive
'` r contact with the underside of the tile.
Fasts
F—Closure
Nail through plastic cement Medium Profile/ Double Pan Tile
iwhen required)
Paddy lBsweathTAw) 1. Starting at the eave course,apply a minimum 2"
Und•rlAyrn•at � v 1 (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the the being set.
loin
•,, 21n.wld• .: �, .,
t, , 2. Continue in same manner. Insure approximately 17
Battens optional : .tib
` r� (109.7 cm2)—23 (148.4 cm2)square inch adhesive
contact with the underside of the tile.
�2in.
Eme Gmute
Earn Course= _ �' jr` *� Fascia
wa through plastic cwmwTd-, High Profile/Single Pan Tile
(afien rcqukedl f•ddy lBeneathTil.l g g
1. Starting at the cave course,apply a minimum 2"
(50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam
paddy onto the underlayment positioned as shown
A� toin.t ` .,,�� ^�� under the pan portion of the tile closest to the
'�. .wide _ '�
- overlock of the the beingset.
Battens `•.` . f 2. Continue in same manner. Insure approximately 17
'l'UDnal ' (109.7 cm2)—23 (148.4 cm2) square inch adhesive
- contact with the underside of the tile.
• eaYet+ruric-• .� �_� • ` • Fascia
••• • • •-. d x• Weephole
10 in •2 • •• ••'i ••:je Eare dosure
'4. ►r in. , Drip edge
• ••• ••• • ••• •
' NOA No.: 14-0805.01
MIAMI- • •• • • ••
APPROVED a *99
99 09 Expiration Date: 05/10/17
Approval Date:09/04/14
. . ... . . . . ...
Page 6 of 11
. . . . . . . . . .
.. .. . . . .. .. .
. . ... . . . ...
ADHESIVE PLACEMENT DETAIL#Z
1b fh,muglnpraaicsem•M , NMV(OmAdhTAP) Flat/Low Profile Tile
lw�Aiew nquieed��s s''�'-+,� 5
°sd"ft'' ,' g ;'= 1. Starting at the eave course,apply a minimum 2"(50.8
Imm)x 10"(254 mm)x 1"(25.4 mm) foam paddy
onto the underlayment positioned as shown under the
'+ f strengthening rib of the tile closest to the overlock of
• fin a t'
the t2he being set. Insure approximately 17(109.7 cm )
—23 (148.4 cm)square inch adhesive contact with the
r„y�,,,,J�J�\/7►/ '� - J � underside of the tile.
2. At the second course,apply a minimum 2"(50.8mm)
Fasda x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
--
`�:�.. underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm2)- 12(77.4 cm)square inch adhesive
contact with the underside of the tile.
twl th""gh pustic amew Medium Profile/Double Pan Tile
lwhem rccMiredf
`� Paddy�s•n•Q�7ilrj 1. Starting at the cave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
the being set. Insure approximately 17(109.7 cm2)—
'sin 23 (148.4 cm )square inch adhesive contact with the
B.tte�as oplwnal '-4,`.
underside of the tile.
2. At the second course, apply a minimum 2"(50.8mm)
'oma tin. - x 7"(177.8 mm)x 1"(25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
F,,,,,c�,,.. �",,_ portion of the tile closest to the overlock of the tile
l Frnru
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2)- 14(90.3 cm2)square inch adhesive
contact with the underside of the tile.
..
(Instructions cb.ntinu. ..L-.l e.n n. eK.t va;.e3
. .. . . . . ... .
.. ... .. . . . ..
. ••• . ••• ... .
.. . . .. . . . . .
• •• •• NOA No.914-0805.01
MIAMMAD;C2UhM •• • ••• Expiration Date: 05/10/17
Approval Date: 09/04/14
••• • •••
Page 7of11
. . . . . . . . . .
. .. .. . . . .. ..
... . . . ... . .
ADHESIVE PLACEMENT DETAIL#2 (CONTINUED)
Nall through pLnik ctprtttr High Profile/Single Pan Tile
iwherr required) ! 1P&dd/(Bene th rile)
4^ 1
U,d#A,y,f,,,t` .�� 1. Starting at the eave course,apply a minimum 2"(50.8
mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17(109.7 cm2)—
'+- Im �. ;, 23 (148.4 cm2) square inch adhesive contact with the
ettttnsopaorul �"' underside of the tile.
2. At the second course, apply a minimum 2"(50.8mm)
Cavecoune Y-Faxia x 7"(177.8 mm)x 1"(25.4 mm)foam paddy onto the
�.. Woophole underlayment positioned as shown under the pan
loin. iN. la"rCID""s portion of the tile closest to the overlock of the tile
Dtlp edge being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2)- 19 (122.6 cm2) square inch adhesive
contact with the underside of the tile.
.. . . . . . ... ..
. ... . . . . .. .
.. . . . .. ... ..
. ... ... . ... .
••' :.' NOA No.: 14-0805.01
MIAW E OL94TY MP• • •• •
®' .•. .. Expiration Date: 05/10/17
Approval Date: 09/04/14
. . ... . . . . ...
Page 8 of 11
. . . . . . . . . .
.. .. . . . .. .• .
. . ... . . . ...
ADHESIVE PLACEMENT DETAIL#3
f"be nqwbem+IhroupFas6cr.�enc Paddyttutweeatdc�
1. On the eave course only,apply a minimum 2" (50.8
mm)x 10" (254 mm)x 1" (25.4 mm)foam paddy
onto the underlayment positioned as shown,under
ti � t the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the Overlock of the tile being set.Leave
approximately 4"(10 1.6 mm)up from the eave
PW* edge free of foam to prevent the expanded adhesive
szase
aeost
_ from blocking the weep holes. Insure
approximately 17-23 int(109.7-148.4 cm2)of
adhesive contact with the underside of the tile
2M
2. Apply a 4"(101.6 mm)x 4" (101.6 mm)x 1" (25.4
mm)foam paddy onto the underlayinent just below
Hat/LowProMeTlle the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
Mdmwoplas& eWdfiraefttk pan portion of the tile, closest to the underlock for
Paaa�IbetecentiFes] the second course tile to be installed. Insure
/ approximately 8-9 int(51.6-58.1 cm2)of adhesive
- l'mdatie) contact with the underside of the tile.
a,mpoftik _ (Instructions continued on next page)
ePae�oe 2:4i �
26i.
Came(Imine
EareCowse Faye
OHedlum ProllleTlte
.. ... . . . . . ..
. .. . . . . ... .
.. ... .. . . . ..
. ... . ... ... .
• • •N&PUP 14-0805.01
LLA Mti X4DE CCIUNTY •• • ••• Expiration Date: 05/10/17
Approval Date:09/04/14
••• • • • • ••• • • Page 9 of 11
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •
ADHESIVE PLACEMENT DETAIL##3 (CONTINUED)
Mail through plastic Single paddy under file
Whenrequired) ce 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x 3/4"
Paddy(betweentilesl (19 mm)paddy on top of the eave course tile
Battens surface as shown, on top of the strengthening rib
wdonwPaddy(under tile)
�r< for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
,,,,,,, y�111Q1 '�`� Install second course of tile. Insure approximately
f
4x41n. — �ti 9(58.1 cm2)- 11 (71cm2)square inch adhesive
` •�''-i, contact with the underside of the tile at the overlap
Single 2 x 4 in
paddy a„ ,', and 7(45.2 cm2)-9(58.1 cm2) square inch
top oftile ' adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
Eave Course Fasda
Weephole
101n. 2 in. Eave dosure
Drip edge
High ProflieTlle
• NOA No.: 14-0805.01
MIAMbOA E � i• • •i i•
r , .,� . .. Expiration Date: 05/10/17
APPROYApproval Date:09/04/14
Page 10 of 11
• • .•. . . • • •..
. . . • . • • • . .
•• •. • • • .. .. .
. . ••. • . • ...
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
Two Piece Barrel(Cap and Pan)Tile
11 place enough adhesive to achieve 65 to 70 sq.in. Steep pitch applications 1. Starting at the eave course,apply a minimum 2"
in contact with the pan tile. (when required) (50.8 mm)x 10„(254 mm)x 1„(25.4 mm)foam
2►Turn coven upside down.Piece adhesive in paddy onto the underlayment positioned as
to I in.from outside edge of cover tile. shown under two adjacent pan tiles. Support eave
Then install the tile.Ensure 20 to
25 sq in contact area. ,-.o tiles from rocking until adhesive has a chance to
undertapment cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2)—70(451.6 cm2)
square inch adhesive contact with the underside
Sheathing
of the pan tile.
Eave clowrc
(motarshown► 3. Turn covers upside down exposing the underside
waephd• Fla Board of the tile. Apply a minimum 1”(25.4 mm)x 10”
asc
(254 mm)bead of adhesive directly on the inner
Remove top portion ofthe eave course cover tile.Abut tosecond course of edge of each side of the cover tile. Leave
pan tiles.Ensure eave end of pan and cover tiles are flush at eave line. approximately 3/4"(19 mm)to 1"(25.4 mm)
Two Piece Barrel-High Profile Tile from the outside edge of the tile,inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20(129 cm2) -25 (161.3 cm2)square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required,2"(50.8
mm)x 4"(101.6 mm)nailers or the tie wire
system using galvanized,stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
.a ••• . . . . . ..
• •• . . . . •••00 .
• . • . . • •
0 00
• ••• . ••• ••• .
•• • • •• • • 1 aA•' j.: 14-0805.01
MtAMt DADE ctxlrn r •• • • Expiration bate: 05/10/17
r Approval Date:09/04/14
••• • • • • ••• • • Page 11 of 11
• • • • • • • • • •
• •• •• • • • •• ••
••• • • • ••• • •