RF-16-2044 CIVIL Reileh Engineering Corp. �.
(Consulting Engineer) /7
2370 Southwest 123'Avenue
Riz Miami,Florida 33175-1174
Tel:305-823-8008/305-397-6414
ENGINEER Fax:305-823-3300/305-884-8834
w
Website:www.reileheng*meermg.com
December 20, 2016
Coda Roofing, Inc.
4678 East 10 Lane
Hialeah, Florida 33013-2112
Project: ROOF TILE UPLIFT TEST REPORT
Residential Home
61 Northeast 108 Street
Miami,Florida
Information proms
Permit Numbe - RF-7-16-204
Date Completion: December 17, 2016
Roofing Contractor: Coda Roofing, Inc.
Project Number: 16-1223
(Testing Laboratory Certificate# 11-0715.04)
Dear Sirs;
In accord..nce with your request and authorization, a representative of Reileh Engineering
Corporation completed the Roof Tile Uplifi'fest at the above referenced project. This testing was
performed in general accordance with Roofing Application Srandard TAS No.106 -- Standard
procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically
attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 10000 squ::ne feet,and the mean height of the
roof is less than 40 feet above ground surface. The type of tile u:;ed for this project was reported to
be Boral Madera 900 Concrete Roof Tile. This tile was reported to have been foamed in place.
At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than
one(1)tile in ten(10)of all components in the field area and one(1)tile in five(5)of all tiles in the
perimeter and comer areas were physically examined. A minimum of one(1)test per every two(2)
squares in the field, one (1) test per square in the perimeter area, ridge caps and (1 1) in the comer
areas were conducted.
Based on our test results; we conclude that the installation of the roo1.f tile at the above referenced
p j q e above-irienfion::d protocol. Attached please find
ria ect meets the,test rc, uirem�a�t outlined in tl�
a copy of our test report for:your review.
Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you
have'any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respectfully submitted;
Reileh Engineering Corporation
Mohamad Sonny Salleh, P.E.49014
Project Manager
TILE UPLIFT TEST
Residential Home
61 Northeast 108 Street
Miami,Florida
Cover Page
Page 2 thru 4 of 4
Drawing 16-1223
Reileh Engineering Corporation--Project Number-16-1223—Page 2 of 4
Report of
TILE UPLIFT TEST
for
Residential Home
61 Northeast 108 Street
Miami,Florida
Project Number: 16-1223
Test Number Test Load lb Test Status
1 35 Pass
2 35 Pass
3 35 Pass
4 35 Pass
5 35 Pass
6 35 Pass
7 35 Pass
8 35 Pass
9 35 Pass
10 35 Pass
11 35 Pass
12 35 Pass
13 35 Pass
14 35 Pass
15 35 Pass
16 35 Pass
17 35 Pass
18 35 Pass
19 35 Pass
20 35 Pass
21 35 Pass
22 35 Pass
23 35 Pass
24 35 Pass
Reileh Engineering Corporation--Project Number-16-1223—Page 3 of 4
Test Number Test Load lb Test Status
25 35 Pass
26 35 Pass
27 35 Pass
28 35 Pass
29 35 Pass
30 35 Pass
31 35 Pass
32 35 Pass
33 35 Pass
34 35 Pass
35 35 Pass
36 35 Pass
37 35 Pass
38 35 Pass
39 35 Pass
40 35 Pass
41 35 Pass
42 35 Pass
43 35 Pass
44 35 Pass
45 35 Pass
46 35 Pass
47 35 Pass
48 35 Pass
49 35 Pass
Test 1-7 Corner, 8-13 Ridge Caps, 14-25 Perimeter, 26-49 Field
Reileh Engineering Corporation--Project Number-16-1223—Page 4 of 4
62'
3
19 20
22
a 5
59
41
18
40 42
44
w 21 25
26
57
29 2b
45
49
19 49
56
52
`6 46
55
24 6
7
2 14 �
I
16 15
NUMM 0r t51' mtJMm - 100 5P O PJn6E CAP 1' sX LOCA11ON
FELP - 24 COnk - 40 5P
COUP � - I KRIWEP P15rANa,a- 5' 6 19NM5 005 111.E
kli9a CAP - 6 ICI-MM AMA- 31!5'
APPROX.POOP 11;5f I OCA110N5,MA5, AN1919IMM10N5