RF-16-1082 (2) C I VI L Reileh Engineering Corp.
(Consulting Engineer)
2370 Southwest 123rd Avenue
Miami,Florida 33175-1174
Tel:305-823-8008/305-397-6414
ENGINEER Fax:305-823-3300/305-884-8834
Website:www.reAehengineering.com
December 1, 2016
Oval Construction
Miami, Florida
Project: ROOF TILE UPLIFT TEST REPORT
Residential Home
124 Northeast 96 Street
Miami Shores,Florida
Information provided by client:
Permit Number: Not Provided
Date Completion: November 28,2016
Roofing Contractor: Oval Construction
Project Number: 16-1165
(Testing Laboratory Certificate# 11-0715.04)
Dear Sirs;
In accordance with your request and authorization, a representative of Reileh Engineering
Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was
performed in general accordance with Roofing Application Standard TAS No.106 -- Standard
procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically
attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was less than 10000 square feet, and the mean height of the
roof is less than 40 feet above ground surface. The type of tile used for this project was reported to
be concrete/clay Roof Tile. This tile was reported to have been foamed in place.
At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than
one(1)tile in ten(10)of all components in the field area and one(1)tile in five(5)of all tiles in the
perimeter and comer areas were physically examined. A minimum of one(1)test per every two(2)
squares in the field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer
areas were conducted.
Based on our test results, we conclude that the installation of.the roof tile:at the above referenced
project meets the test requirement outlined i.n the above-mentioned protocol. Attached please find
a copy of our test report for your review.
Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you
have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
Respectfully submitted;
Reileh Engineering Corporation
ohamad Sonny Salleh, P.E.49014
Project Manager
TILE UPLIFT'TEST
Residential Home
124 Northeast 96 Street
Miami Shores,Florida
Submittals:
Cover Page
Page 2 thru 3 of 3
Drawing 16-1165
Reileh Engineering Corporation--Project Number-16-1165—Page 2 of 3
Report of
TILE UPLIFT TEST
for
Residential Home
124 Northeast 96 Street
Miami Shores,Florida
Project Number: 16-1165
Test Number Test Load lb Test Status
1 35 Pass
2 35 Pass
3 35 Pass
4 35 Pass
5 35 Pass
6 35 Pass
7 35 Pass
8 35 Pass
Test 1-2 Corner, 3 Ridge Caps, 4-5 Perimeter, 6-8 Field
Rcileh Engineering Corporation--Project Number-16-1165—Page 3 of 3
15
I 5
6
7
� A
8
2
Numk OF 1 5f P�t;INl tr - 100 5F O Q96E CAP S5r LOCATION
FEW 3 C01M - 20 5P
C01M - 2 Kt;INI Sk 1915fANa,a - 5' L MNO1�5 005 WU 16-1 16
f t?a CAP < I COM ASA- 5'X 5'
APPPDX.WOr T5T LOCA11ON5,MA5, ANI7 PIWN51ON5