RF-16-1082 (2) C I VI L Reileh Engineering Corp. (Consulting Engineer) 2370 Southwest 123rd Avenue Miami,Florida 33175-1174 Tel:305-823-8008/305-397-6414 ENGINEER Fax:305-823-3300/305-884-8834 Website:www.reAehengineering.com December 1, 2016 Oval Construction Miami, Florida Project: ROOF TILE UPLIFT TEST REPORT Residential Home 124 Northeast 96 Street Miami Shores,Florida Information provided by client: Permit Number: Not Provided Date Completion: November 28,2016 Roofing Contractor: Oval Construction Project Number: 16-1165 (Testing Laboratory Certificate# 11-0715.04) Dear Sirs; In accordance with your request and authorization, a representative of Reileh Engineering Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No.106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 40 feet above ground surface. The type of tile used for this project was reported to be concrete/clay Roof Tile. This tile was reported to have been foamed in place. At the time of our inspection,the entire area of the roof was examined for loose tiles. Not less than one(1)tile in ten(10)of all components in the field area and one(1)tile in five(5)of all tiles in the perimeter and comer areas were physically examined. A minimum of one(1)test per every two(2) squares in the field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer areas were conducted. Based on our test results, we conclude that the installation of.the roof tile:at the above referenced project meets the test requirement outlined i.n the above-mentioned protocol. Attached please find a copy of our test report for your review. Reileh Engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation ohamad Sonny Salleh, P.E.49014 Project Manager TILE UPLIFT'TEST Residential Home 124 Northeast 96 Street Miami Shores,Florida Submittals: Cover Page Page 2 thru 3 of 3 Drawing 16-1165 Reileh Engineering Corporation--Project Number-16-1165—Page 2 of 3 Report of TILE UPLIFT TEST for Residential Home 124 Northeast 96 Street Miami Shores,Florida Project Number: 16-1165 Test Number Test Load lb Test Status 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass Test 1-2 Corner, 3 Ridge Caps, 4-5 Perimeter, 6-8 Field Rcileh Engineering Corporation--Project Number-16-1165—Page 3 of 3 15 I 5 6 7 � A 8 2 Numk OF 1 5f P�t;INl tr - 100 5F O Q96E CAP S5r LOCATION FEW 3 C01M - 20 5P C01M - 2 Kt;INI Sk 1915fANa,a - 5' L MNO1�5 005 WU 16-1 16 f t?a CAP < I COM ASA- 5'X 5' APPPDX.WOr T5T LOCA11ON5,MA5, ANI7 PIWN51ON5